Intrusion Alarm Systems | B430 Plug-in Telephone Communicator
B430 Plug-in Telephone Communicator
www.boschsecurity.com
u Provides a single telephone line with RJ-45
connection for central station reporting and remote
programming
u Easily configured for communications from Remote
Programming Software (RPS) or a keypad,
eliminating the need for separate configuration
The B430 provides communication over the PSTN
(Public Switched Telephone Network) by connecting
the PSTN to the control panel. The module provides a
single telephone jack, and easily installs into the
control panel on-board plug-in module connector.
Functions
Central station reporting
The B430 supports reporting to a central station
receiver through the telephone lines.
Remote programming of Bosch control panels
The B430 supports secure RPS programming of
compatible Bosch control panels.
Certifications and approvals
Region FCC Details
USA FCC Registration Number: ESVAL00BB430
Ringer Eq: 0.0B
Region Certification
Australia RCM ACMA
Europe CE EMC, RoHS
USA UL UL 365 - Police Station Connected Bur-
glar Alarm Units
u Easy two-step plug-in installation, troubleshooting,
and maintenance
Region Certification
UL UL 636 - Holdup Alarm Units and Sys-
tems
UL UL 864 - Standard for Control Units and
Accessories for Fire Alarm Systems
UL UL 985 - Household Fire Warning Sys-
tem Units
UL UL 1023 - Household Burglar Alarm Sys-
tem Units
UL UL 1076 - Proprietary Burglar Alarm
Units and Systems
UL UL 1610 - Central Station Burglar Alarm
Units
CSFM see our website
FCC Part 15 Class B
FCC Part 68
FDNY-
6174
CoA
Canada ULC CAN/ULC S303 - Local Burglar Alarm
Units and Systems
ULC CAN/ULC S304 - Standard for Signal Re-
ceiving Center and Premise Burglar
Alarm
ULC CAN/ULC S545 - Residential Fire Warn-
ing System Control Units
2 | B430 Plug-in Telephone Communicator
Region Certification
ULC CAN/ULC S559 - Fire Signal Receiving
Centres and Systems
ULC ULC-ORD C1023 - Household Burglar
Alarm System Units
ULC ULC-ORD C1076 - Proprietary Burglar
Alarm Units and Systems
IC ICES-003 - Information Technology
Equipment (ITE)
Brazil ANATEL 1709-13-1855 [B430]
Installation/configuration notes
Mounting considerations
Connect the B430 Plug-in Telephone Communicator to
any compatible control panel or interface module,
which can then be mounted in a variety of enclosures
for optimal situations.
Wiring considerations
The B430 connects to the control panel or interface
modules without tools or physical wiring for power. It
has an RJ-45 jack for plugging in the phone line
(PSTN).
Communication speed
The module communicates at 2400 baud maximum.
Compatibility
Power requirements
Current (maximum) Standby: 24 mA
Alarm: 24 mA
Voltage (operating) 12 VDC nominal
Ordering information
B430 Plug-in Telephone Communicator
Plug-in PSTN communication module for control panel
to central station receiver communication.
Order number B430
Control panels B9512G/B9512G-E
B6512
B8512G/B8512G-E
B5512/B5512E
B4512/B4512E
B3512/B3512E
Phone cords D161 Dual Modular Telephone Cord
D162 Modular Telephone Cord
Phone jack D166 Telephone Jack
Parts included
Quantity Component
1 B430 Plug-in Telephone Communicator
1 Literature pack
Technical specifications
Properties
Dimensions 2 in x 3.68 in x 0.60 in
(50 mm x 93.5 mm x 15.25 mm)
Weight 1.3 pounds (0.6 KG)
Environmental considerations
Relative humidity 5% to 93% at +32°C (+90°F)
Temperature (operating) 0°C to +49°C (+32°F to +120°F)