Intrusion Alarm Systems | B201 2-wire Powered Loop Module
B201 2-wire Powered Loop Module
www.boschsecurity.com
u Suitable for use with 2-wire smoke detectors and
burglary devices
u Supports up to 20 compatible smoke detectors
u Resets latching devices from the control panel
The B201 provides a single powered initiating device
circuit. The module supports compatible 12 V 2-wire
smoke detectors. The B201 is suitable for connecting
powered, 2-wire fire or burglary devices. Use with a
D132A Smoke Detector Reversing Relay Module for
smoke detectors with integrated sounders.
Functions
The module connects to the control panel inputs.
Terminals A and COM are a direct connection (passthru) point, and terminals B and PWR are a powered
loop.
The powered loop uses a 1.8 kΩ EOL for supervision.
Certifications and approvals
Region
US UL 365 ᅳ Police Station Connected Burglar Alarm Units and
Systems
u Connects to the control panel terminal block with
easy-to-install integrated pins
Region
UL 1076 ᅳ Proprietary Burglar Alarm Units and Systems
UL 1610 ᅳ Central Station Burglar Alarm Units
CSFM ᅳ California Office of The State Fire Marshal
FCC Part 15 Class B
Canada CAN/ULC S303 ᅳ Local Burglar Alarm Units and Systems
CAN/ULC S304 ᅳ Signal Receiving Centre and Premise
Alarm Control Units
CAN/ULC S545 ᅳ Residential Fire Warning System Control
Units
ULC-ORD C1023 ᅳ Household Burglar Alarm System Units
ULC-ORD C1076 ᅳ Propriety Burglar Alarm Units and
Systems
ICES-003 ᅳ Digital Apparatus
UL 609 ᅳ Local Burglar Alarm Units and Systems
UL 636 ᅳ Holdup Alarm Units and Systems
UL 985 ᅳ Household Fire Warning System Units
UL 1023 ᅳ Household Burglar Alarm System Units
Region Certification
USA CSFM see our website
2 | B201 2-wire Powered Loop Module
Represented by:
Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
201 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
latam.boschsecurity@bosch.com
www.boschsecurity.com
© Bosch Security Systems 2014 | Data subject to change without notice
14860870155 | en, V3, 04. Nov 2014
Installation/configuration notes
Compatible control panels
B5512/B5512E v2.01 and higher
B4512/B4512E v2.01 and higher
B3512/B3512E v2.01 and higher
Compatible detectors
Supports mixing detectors of different model numbers
and manufacturers. For a list of compatible 2-wire
smoke detectors, refer to the 2-wire Powered Loop
Module (B201) Installation Guide.
Compatible modules
D132A Smoke Detector Reversing Relay Module
Parts included
Quant. Component
1 B201 module
1 1.8 kΩ EOL resistors (P/N: F01U009011)
2 Standoffs
1 Installation Guide
Technical specifications
Dimensions 1.42 in x 1.42 in x 1.48 in (36 mm x36
mm x 37.6 mm)
Voltage (operating) 12 V
Current (maximum) 35 mA in alarm, 18 mA in standby
Temperature (operating) 0°C to +49°C (+32°F to +120°F)
Relative humidity 5% to 93% at +32°C (+90°F)
2-wire smoke loop wiring 50 Ω
0.65 mm (22 AWG) – 1500 ft (457 m)
1.02 mm (18 AWG) – 3900 ft (1188 m)
Ordering information
B201 2-wire Powered Loop Module
The module provides a single powered initiating device
circuit. The module supports compatible 12 V 2-wire
smoke detectors. It also supports connecting burglary
devices to the control panel.
Order number B201