Bosch AMC2-4WE, AMC2 Installation Manual

AMC2 Extension
AMC2‑4WE
en
Installation Manual
AMC2 Extension Table of contents | en 3
Bosch Access Systems GmbH Installation Manual 2018-02 | AMC2-4WE |
1
Safety Instructions 4
1.1 Important Safety Notes 4
1.2 Safety Precautions 5
1.3 Unpacking 6
2
Important Information 7
2.1 Explanation of symbols in this document 7
2.2 Internet 7
3
Introduction 8
3.1 Description 8
3.2 Equipment Configuration 9
3.3 Performance Characteristics 10
3.4 System Overview 10
4
Installing 12
4.1 Mounting 12
4.2 Unmounting 13
4.3 Opening the Case 14
4.4 Closing the Case 15
4.5 Cabling 15
4.5.1 Conductor data for power to AMC2 15
4.6 Grounding and Shielding 17
4.6.1 Grounding for Extension Interface 17
4.7 Connecting Power Supply 18
4.7.1 Direct Power Supply 18
4.7.2 Power Supply via RS-485 Interface 18
4.7.3 Overview - Power supply/consumption 19
4.8 RS-485 for extension modules 21
4.9 Wiegand Interface for Card Readers 22
4.10 Connecting Relay Outputs 22
4.11 Connecting Analog Input Devices 26
4.12 Tamper Protection 28
5
Operating 29
5.1 Status Display of the AMC2 29
6
Technical Data 31
7
Appendices 33
7.1 Connecting Diagrams 33
Index 36
4 en | Safety Instructions AMC2 Extension
2018-02 | AMC2-4WE | Installation Manual Bosch Access Systems GmbH
1 Safety Instructions
1.1 Important Safety Notes
1. Read, follow, and retain instructions - All safety and operating instructions must be read and followed properly before putting the unit into operation. Retain instructions for future reference.
2. Do not ignore warnings - Adhere to all warnings on the unit and in the operating instructions.
3. Accessories - Use only accessories recommended by the manufacturer or those sold with the product. Accessories not recommended by the manufacturer must not be used, as they may cause hazards.
4. Installation precautions - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit may fall, causing serious injury to persons and damage to the unit. Mount the unit according to the manufacturer’s instructions.
5. Service - Do not attempt to service this unit by yourself. Opening or removing covers may expose you to dangerous voltages or other hazards. Refer all servicing to qualified service personnel.
6. Damage which requires service - Disconnect the unit from the main AC or DC power source and refer servicing to qualified service personnel under the following conditions: – If the power supply cord or plug is damaged. – If liquid has been spilled or an object has fallen into the unit. – If the unit has been exposed to water and/or inclement weather (rain, snow, etc.). – If the unit does not operate normally when following the operating instructions.
Adjust only those controls specified in the operating instructions. Improper adjustment of other controls may result in damage, and require extensive work by a
qualified technician to restore the unit to normal operation. – If the unit has been dropped or the cabinet damaged. – If the unit exhibits a distinct change in performance.
7. Replacement parts - If replacement parts are required, the service technician must use only replacement parts that are specified by the manufacturer. Unauthorized replacements may result in fire, electrical shock or other hazards.
8. Safety check - Upon completion of service or repair work on the unit, ask the service technician to perform safety checks to ensure that the unit operates properly
9. Power sources - Operate the unit only from the type of power source indicated on the label. If unsure of the type of power supply to use, contact your dealer
10. Lightning - For added protection during electrical storms external lightning conductors can be installed. This prevents power surges from damaging the unit.
11. The units should be installed in locations with restricted access.
AMC2 Extension Safety Instructions | en 5
Bosch Access Systems GmbH Installation Manual 2018-02 | AMC2-4WE |
1.2 Safety Precautions
Read instructions!
Before working with the AMC2 device, read these instructions carefully. Make sure you have understood all information described in this document.
!
Warning! Risk of electric shock
External power supplies must be installed and put into service by qualified personnel. Ensure compliance with the relevant regulations. Ground the controller. Disconnect both AC and battery power supply before working on the controller.
!
Warning! Risk of fire
Installation of the AMC2 device must comply with any local fire, health, and safety regulations. A secured door that may be part of an escape route from an area must be installed with: Install a fail-safe lock (A), so that the door will be released if power fails. Ideally, use a magnetic lock. Install a normally-closed break glass or a manual pull (B) in the lock supply wiring, so that in an emergency the fail-safe lock can be immediately powered down.
!
Warning! Risk of explosion of Lithium battery
The battery can explode if it is replaced incorrectly. Replace only with the same type as recommended by the manufacturer. Dispose used batteries according to the battery manufacturer’s instructions.
Notice! Risk of damage to equipment
Protect the hardware from electrostatic discharge by observing ESD instructions before unpacking of touching connectors of electronics. Always switch off power of the AMC2 device before modifying the installation. Do not connect or disconnect plug connectors, data cables, or screw connectors while power is on.
Rules and Conditions
There are no specific requirements as for selling and delivery. As for storage and safe operation, the environmental temperature should not exceed the range of 0°C to 50°C.
Disposal
Your Bosch product is designed and manufactured with high-quality materials and components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
6 en | Safety Instructions AMC2 Extension
2018-02 | AMC2-4WE | Installation Manual Bosch Access Systems GmbH
In the European Union, there are separate collection systems for used electrical and electronic products. Please dispose of this equipment at your local community waste collection/recycling center.
1.3 Unpacking
Check the packaging for visible damage. If anything has been damaged during transport, please inform the transport agency. Unpack the unit carefully. This is an electronic device that must be handled with care to avoid damage. Do not attempt to put the unit into operation if components are damaged. If any parts are missing, inform your customer service representative or a Bosch Security Systems salesperson. The shipping carton is the safest transport container for the unit. Store it and the other packaging material for future use. If the unit has to be sent back, use the original packaging.
AMC2 Extension Important Information | en 7
Bosch Access Systems GmbH Installation Manual 2018-02 | AMC2-4WE |
2 Important Information
Remarks
This hardware is part of a security system. Access should be limited to authorized persons only. Some states do not allow the exclusion or limitation of implied warranties, or limitation of liability for incidental or consequential damages, hence the above limitation or exclusion might not apply to you. Bosch Security Systems retains all rights not expressly granted. Nothing in this license constitutes a waiver of Bosch’s rights under the U.S. Copyright laws or any other federal or state law. If you have any questions concerning this license, please, write to:
Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany.
2.1 Explanation of symbols in this document
Throughout this document, warning messages, important notes, and helpful tips are presented for the reader. These appear as follows:
Danger!
Cause of Hazard Indicates a hazardous situation, which, if not avoided, will result in death or serious injury.
!
Warning!
Cause of Hazard Indicates a hazardous situation, which, if not avoided, could result in death or serious injury.
!
Caution!
Cause of Hazard Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury.
Notice!
Cause of Hazard Important Notes that must be followed to avoid damage to the equipment or environment, and to ensure successful operation and programming. Tips and shortcuts may also be included in such notes.
2.2 Internet
If you are interested in further information on this product or information on other products, please consult our website at http://www.boschsecurity.com.
8 en | Introduction AMC2 Extension
2018-02 | AMC2-4WE | Installation Manual Bosch Access Systems GmbH
3 Introduction
3.1 Description
The extension module AMC2-4WE is equipped with four Wiegand type reader-interfaces plus eight inputs and eight outputs. Hence with the AMC2-4WE it is possible to double the number of readers on an AMC2-4W from 4 to 8.
Figure3.1: The extension module AMC2-4WE
The AMC2-4WE can not be deployed as an independent controller but only as an extension module for the AMC2-4W. Control and access decisions and bookings are carried out by the AMC2-4W alone.
Notice!
The AMC2-4WE can only be used with AMC2-4W. As it provides Wiegand interfaces it cannot be coupled with an AMC2-4R4.
The AMC2-4W can be extended by a maximum of one AMC2-4WE plus a maximum of three I/O extension modules. The I/O extension modules AMC2-8IOEAMC2-16IOE (in any combination) are, like the AMC2-4WE, connected via the AMC2-4W’s extension interface.
Notice!
The AMC2-4WE has no display. The information about the input and outputs will be shown on special pages of the AMC2 display.
As the extension modules contain neither memory nor display they are controlled and monitored entirely by the AMC2-4W. The AMC2-4W can have an additional interface extension module AMC2-4WE, so that the number of inputs and outputs can grow up to 64.
Notice!
An AMC2-4WE provides signals only to the AMC2 to which it is connected. Signal transfer to another AMC2 is not possible.
The signal settings and parametrization of the readers connected to the extension module, are carried out by the configuration applications in the access control system and by the AMC2-4W to which it belongs.
AMC2 Extension Introduction | en 9
Bosch Access Systems GmbH Installation Manual 2018-02 | AMC2-4WE |
3.2 Equipment Configuration
Figure3.2: Overview - Interfaces
1 RS-485 extension module bus
2 External tamper contact
3 Connector for power supply
4 Wiegand interfaces for up to 8card readers
5 Connectors for eight analog inputs
6 Connectors for eight relay outputs
Figure3.3: Jumpers at the bottom side
7 Jumper for setting either voltage free relay output (“dry” mode) or looped-in voltage
from the AMC2 internal power supply (“wet” mode).
8 Jumper: Equalization of potential between different systems and earth ground
(shield) for the extension interface.
10 en | Introduction AMC2 Extension
2018-02 | AMC2-4WE | Installation Manual Bosch Access Systems GmbH
3.3 Performance Characteristics
Controlled by an AMC2 via RS-485 – Reader interfaces
four two Wiegand interfaces
Eight relay outputs
voltage free, power is supplied externally (dry mode) – powered by internal power supply (wet mode)
Eight analog inputs with internal power supply – Transfer rate to the extension interface: 9,6 kBit/s – Self regulating transmit/receive switching – Power supply:
10V - 30Vdc - max. 5 A – or over the RS-485 host connector
Information about the inputs and outputs on the display of the AMC2 controller – Tamper contact for external covers
Notice!
If an external power supply is used, this should also guarantee an uninterruptable power supply (UPS). Example: Bosch power supply APS-PSU-60 (F.01U.282.970).
3.4 System Overview
The AMC2-4WE is connected between the access controller AMC2-4W and the various peripheral devices.
Figure3.4: System overview
1 = Host
2 = AMC2-4W
3 = Card reader
4 = Communication and power supply
5 = AMC2-4WE
AMC2 Extension Introduction | en 11
Bosch Access Systems GmbH Installation Manual 2018-02 | AMC2-4WE |
System configurations for Access Control applications. – The minimum configuration consists of:
one PC with system software, – one AMC2 controller, – one AMC power supply,
one AMC enclosure. – The maximum configuration depends on the system software, – Each AMC2-4W controller can be extended with an AMC2-4WE extension module. The using of AMC2-4WE modules has no influence on the limit of the maximum of controllers in one system, because it is an extension to an AMC2-4W and not a controller. Using Wiegand reader interfaces, up to four peripheral devices can be connected to each AMC2-4R4. The interfaces are point-to-point connections, meaning that only one reader can be connected to one interface.
12 en | Installing AMC2 Extension
2018-02 | AMC2-4WE | Installation Manual Bosch Access Systems GmbH
4 Installing
Notice!
To build an UL approved system refer the documentation contained in the folder titled "_UL" on the delivered CD.
4.1 Mounting
The AMC2-4R4 can be attached on a standard 35mm (1.377in.) mounting rail using a snap-in mechanism. Attach the AMC2-4R4 into the upper edge of the mounting rail [1], then push down the device and snap it onto the rail by pushing it towards the back [2].
Figure4.1: Mounting the AMC2 device on a mounting rail