Bosch 1903-10, 1906-10, 1914-10, 1912-10 User Manual

Page 1
Plena Mixer Amplifier
Installation and Operating Manual
LB B 19 03/10, LB B 190 6/10 ,
en
LB B 1912/10 , L BB 1914/10
Page 2
Page 3
Plena Mixer Amplifier | Installation and Operating Manual | Important safeguards en | 3

Important safeguards

should be read before the system is operated.
2 Retain instructions - The safety instructions and
instructions for use should be retained for future reference.
3 Heed warnings - All warnings on the unit and in the
operating instructions should be adhered to.
4 Follow instructions - All operating instructions and
instructions for use should be followed.
5 Cleaning - Unplug system units from the mains outlet
before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
6 Attachments - Do not use attachments not
recommended by the product manufacturer as they may cause hazards.
7 Water and Moisture - Do not use this unit near water, for
example near a bathtub, washbowl, kitchen sink, or laundry basket, in a wet basement, near a swimming pool, in an unprotected outdoor installation or any area which is classified as a wet location.
8 Accessories - Do not place this unit on an unstable stand,
tripod, bracket or mount. This unit may fall, causing serious injury to a person and serious damage to the unit. Use only a stand, tripod, bracket or mount recommended by the manufacturer, or sold with the product. Any mounting of the unit should follow the manufacturer's instructions, and should use a mounting accessory recommended by the manufacturer. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn.
9 Ventilation - Openings in the enclosure, if any, are
provided for ventilation and to ensure reliable operation of the unit and to protect it from overheating. These openings must not be blocked or covered. The unit should not be placed in a built-in installation unless proper ventilation is provided or the manufacturer's instructions have been adhered to.
10 Power sources - Units should be operated only from the
type of power source indicated on the marking label. If you are not sure of the type of power supply you plan to use, consult your appliance dealer or local power company. For units intended to operate from battery power, or other sources, refer to the "Installation and User Instructions".
11 Grounding or polarisation - This unit may be equipped
with a polarised alternating current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug still fails to fit, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarised plug. Alternatively, this unit may be equipped with a 3-wire grounding type plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type lug.
12 Power-Cord Protection - Power supply cords should be
routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance.
13 Overloading - Do not overload outlets and extension
cords as this can result in a risk of fire or electrical shock.
14 Object and Liquid Entry - Never push objects of any
kind into this unit through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit.
15 Servicing - Do not attempt to service this unit yourself as
opening or removing covers may expose to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
16 Damage Requiring Service - Unplug the unit from the
outlet and refer servicing to qualified service personnel under the following conditions:
When the power-supply cord or plug is damaged.
If liquid has been spilled, or objects have fallen into the unit.
If the unit has been exposed to rain or water.
If the unit does not operate normally by following the instructions for use. Adjust only those controls that are covered by the instructions for use, as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the units to their normal operation.
If the unit has been dropped or the unit has been damaged.
When the unit exhibits a distinct change in performance; this indicates a need for service.
17 Replacement Parts - When replacement parts are
required be sure the service technician has used replacement parts specified by the manufacturer or parts which have the same characteristics as the original part. Unauthorised substitutions may result in fire, electric shock or other hazards.
18 Safety Check - Upon completion of any service or
repairs to the units, ask the service technician to perform safety checks to determine that the unit is in proper operating condition.
19 Lightning - For added protection of the units during a
lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the cable system. This will prevent damage to the unit due to lightning and power-line surges.
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 4
Plena Mixer Amplifier | Installation and Operating Manual | About this manual en | 4

About this manual

This manual provides all the information required to install and operate the unit.
Conventions
Warning
Follow these instructions to prevent personal injury.
Caution
Follow these instructions to prevent damage to the equipment.
Note
Read these instructions for tips and other useful information.

Safety precautions

Warning
Do not open the unit when it is connected to the mains. The unit contains non-insulated parts, which can cause electric shock.
Caution
There are no user-serviceable parts inside the unit. Service must be done by qualified personnel.
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 5
Plena Mixer Amplifier | Installation and Operating Manual | Table of contents en | 5

Table of contents

Important safeguards..........................................................................................................................................................3
About this manual ..............................................................................................................................................................4
Safety precautions...............................................................................................................................................................4
Table of contents ................................................................................................................................................................5
1 About the mixer amplifier ................................................................................................................................................7
1.1 Controls and connections (front) .............................................................................................................................8
1.2 Controls and connections (rear) ..............................................................................................................................9
2 Internal settings ................................................................................................................................................................10
2.1 Setting the VOX for microphone input 1 ............................................................................................................10
2.2 Setting the speech filters .........................................................................................................................................10
2.3 Setting the chime volume ......................................................................................................................................11
2.4 Setting the output voltage for LBB1903, LBB1906 and LBB1912 ....................................................................11
2.5 Setting the output voltage for LBB1914 ...............................................................................................................11
3 Installation in rack ...........................................................................................................................................................12
4 External settings and connections .................................................................................................................................13
4.1 Connect the DC supply (battery) ..........................................................................................................................13
4.2 Priority microphone ...............................................................................................................................................13
4.3 Chime ON/OFF-switch .........................................................................................................................................14
4.4 Microphone inputs ..................................................................................................................................................15
4.5 Emergency input .....................................................................................................................................................15
4.6 Music source inputs ................................................................................................................................................16
4.7 Connecting the line output ....................................................................................................................................16
4.8 Connecting loudspeakers .......................................................................................................................................17
4.8.1 Constant voltage loudspeakers .........................................................................................................................17
4.8.2 Low impedance loudspeakers ..........................................................................................................................18
4.9 Mains connection ....................................................................................................................................................18
5 Operation of mixer amplifier .........................................................................................................................................19
5.1 Source selection .......................................................................................................................................................19
5.2 Volume and tone control .......................................................................................................................................19
5.3 Zone selection (LBB1914/10 only) .......................................................................................................................19
6 Technical data ..................................................................................................................................................................20
6.1 Electrical ..................................................................................................................................................................20
6.2 Performance ............................................................................................................................................................20
6.3 Inputs ........................................................................................................................................................................20
6.4 Outputs .....................................................................................................................................................................21
6.5 Environmental conditions ......................................................................................................................................21
6.6 General .....................................................................................................................................................................22
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 6
Plena Mixer Amplifier | Installation and Operating Manual | Table of Contents en | 6
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 7
Plena Mixer Amplifier | Installation and Operating Manual | en | 7
About the mixer amplifier

1 About the mixer amplifier

JP406
LINE
LINE/MIC
/
MIC
Phantom Power
JP401
JP402
JP403
JP405
115V,230V
201
100V
INSInIN
S
Out
Click suppression
100V
70V
8Ohm
70V
70V
100V
0
Call Active
0
JP902 100/70
0
Z2 Front
Call Active
JP802
0
0
0
Z1 Front
8Ohm
0
24V
8Ohm
JP901 100V
70V
0
24V
0
0
0
100V
0
70V
0
8Ohm
0
Call Only
0
Mix O nly
0
+
24V
-
Call Only
0
Zone 1 Call/Mix
0
0
Call/Mix
0
Zone 2 Call/Mix
0
Mix O nly
0
0
+
24V
-
Only for LBB1914/10
Figure 1.1
The Plena Mixer Amplifier is a mono amplifier for mixing up to 4 microphone signals and (background) music signals. You can adjust the volume of each input separately in order to obtain the correct mix and control the mixed output via the master volume and tone controls. Microphone input 1 can have priority with an optional chime signal, muting other sources. The power amplifier has a direct output for mixed signals and priority announcements, but additionally a priority controlled output relay routes the output to loudspeaker zones that should receive only priority announcements or no priority announcements at all.
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 8
Plena Mixer Amplifier | Installation and Operating Manual | en | 8
About the mixer amplifier

1.1 Controls and connections (front)

2
Plena Mixer Amplifier
0dB
-6 dB
-20 dB
Power
1
3
1
3
5 6 7 10 11 12 13
4 8 9
2
4
Select
CD AUX
Line
Figure 1.2
1 Power button 2 VU-meter (LED's for -20, -6, 0 dB and Power ON) 3 Input 1 (microphone) volume control 4 Input 2 (microphone) volume control 5 Input 3 (microphone) volume control 6 Input 4 (microphone) volume control 7 Line (music source) volume control
Only for LBB1914/10
Master Zone 1 Zone 2
8 Music source selector (CD, tape, AUX) 9 Master tone control (treble) 10 Master tone control (bass) 11 Master volume control (all inputs except emergency) 12 Zone 1 selection button (LBB1914/10 only) 13 Zone 2 selection button (LBB1914/10 only)
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 9
Plena Mixer Amplifier | Installation and Operating Manual | en | 9
About the mixer amplifier

1.2 Controls and connections (rear)

7
Chime
12
8 9 10 11 12 13 14 19
Tel/Emer.
0
2
45
1
L
R
CD Aux Line Out 1V
++GND
3
31
2
2 3 4
GND
1
231
Mic/Line Mic/Line
0
Out
In
Inc
4 43 5 5 4 5 15
Figure 1.3
1 Chime ON/OFF switch 2 Priority microphone input (5-pole DIN/balanced
with Phantom power)
3 Input 1 microphone input (6.3 mm phono jack/
balanced with Phantom power)
4 Microphone input (XLR/balanced with Phantom
power in microphone mode) 5 Microphone input (6.3 mm phono jack/balanced) 6 Input Mic./Line switch 7 Emergency connection input terminals 8 Emergency volume pre-set 9 CD input (2x phono connectors) 10 Tape input (2x phono connectors) 11 Auxiliary input (2x phono connectors)
230V115V
Call/Mix
100V 0 70V 0 100/70V 0 100/70 V 080
Zone1 Zone 2
Call/Mix
100/70V/8 0 100/70V 0 100/70V 0 100/70V 0 100/70V 0
Only for LB B 1914 /10
CallOnly Mix Only
CallOnly Mix Only
24VDCIn
15
24VDCIn
16 186 6
17
12 Line output (XLR) 13 Tape output (2x phono connectors) 14 Insertion input/output (2x phono connectors) 15 Loudspeaker output terminals and 24 Vdc power
supply terminals 16 Mains connector (3-pole) 17 Earth connection screw 18 Mains fuse
LBB1903 T1A (230 Vac) / T2A (115 Vac)
LBB1906 T1.6A (230 Vac) / T3.15A (115 Vac)
LBB1912 T2.5A (230 Vac) / T5A (115 Vac)
LBB1914 T2.5A (230 Vac) / T5A (115 Vac) 19 Mains voltage 115/230 V switch
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 10
Plena Mixer Amplifier | Installation and Operating Manual | en | 10
Internal settings

2 Internal settings

123 123
Figure 2.1
123 123
70V/100V
LBB1914/10
70V
100 V
JP802
LBB1903/10 LBB1906/10 LB B1912/10
8Ohm
JP902
Mic. 3
Mic. 4
70V
100V
JP802
Mic.3
JP402
Mic.4
JP405
JP902
Mic.4
JP405
JP401
VOX
JP403
Mic.3
JP403
JP406
Mic.2
Mic.1
VR401
Mic. 4
JP402
JP401
VOX
JP406
Mic.2
Mic.1
VR401
JP901
JP403
JP405
123 123
OFF
Mic. 3
JP403
JP405
123 123
OFF
JP402
JP401
VOX
JP406
Mic. 2
Mic. 1
ON
JP402
JP401
VOX
JP406
Mic. 2
Mic. 1
ON
123 123
100 V
70V
JP901
Figure 2.2

2.1 Setting the VOX for microphone input 1

Input 1 has the option of a voice-controlled priority (VOX), which will overrule all other inputs when it recognizes a voice signal. To activate this function, set the VOX-jumper (JP406) to ON.

2.2 Setting the speech filters

The speech intelligibility can be improved by cutting off the lower frequencies of the signal. To activate this filter for each microphone input, set the respective filter jumper (JP401 for input 1, JP402 for input 2, JP403 for input 3 and JP405 for input 4) to ON.
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 11
Plena Mixer Amplifier | Installation and Operating Manual | en | 11
Internal settings

2.3 Setting the chime volume

Adjusting the potentiometer VR401 changes the volume of the chime attention signal, preceding a priority call. Be careful not to adjust VR701; this is a power amplifier factory adjustment.

2.4 Setting the output voltage for LBB1903, LBB1906 and LBB1912

Direct outputs for 70 V, 100 V and low impedance (8 Ohm) loudspeakers are provided. Jumper JP802 sets the Call Only and Mix Only outputs to 70 V or 100 V output. These outputs are controlled by a priority relay. The Call Only output only provides priority announcements, while the Mix Only output just provides the mixed signals and switches off at priority calls.

2.5 Setting the output voltage for LBB1914

Jumper JP901 sets the Call/Mix, Zone 1, Zone 2, Call Only and Mix Only outputs to 70 V or 100 V output. Setting JP902 can also set the direct Call/Mix output to 8 Ohm for low impedance loudspeakers. The Call Only and Mix Only outputs are controlled by a priority relay. The Call Only output only provides priority announcements, while the Mix Only output just provides the mixed signals and switches off at priority calls. The zone selection buttons control the outputs of Zone 1 and 2, but priority announcements are always routed to these zones.
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 12
Plena Mixer Amplifier | Installation and Operating Manual | en | 12
1
15V/ 23 0V
A
p
p
aratu
s
d
e
liv
e
r
e
d
con
ne
cted f
or
230
V
-
Ra
te
dinp
u
t
p
ower : 4
0
0
V
A
Thi
sapp
aratus m
u
s
t
W
arni
n
g
Call/Mi
x
24VD
C
In
C
al
l
Only
Mi
x
O
n
l
y
70
V0
10
0
/70
V
0
100
/70
V
0
80
Installation in rack

3 Installation in rack

T e l /
L
E m e r . 0
Plena
M
i
xe
r
Amp
lif
i
e
r
0
d
B
-6d
1
B
-
2
0d
B
P
o
w
e
r
1
3
-
12 VD C
2
Se
l
e
c
t
CD
A
U
4
+
X
L
i
n
e
F
+
- +
+
12 VD C
Figure 3.1
The mixer amplifier is delivered for tabletop use, but you can mount it in a 19" rack. If you mount the amplifier in a rack, you must:
ensure that the unit does not exceed the overheating temperature (45 °C ambient).
use the mounting brackets which can be ordered by Bosch (LBC 1901/00).
remove the 4 feet from the bottom of the unit. Without the feet the unit is 2U high.
0 2
C h i m
e
Mas
t
e
r
LBB1903 (30W); F=F5A
LBB1906 (60W); F=F8A LBB1912 (120W); F=F15A LBB1914 (120W); F=F15A
R
C
D
O
u t
A
u x
1
L
- i n
- e
3
In
O
u t
4
1
V . 5
In
c M i c /L
i n e
M i c
/
L
i
1
n
e
2
3
1 1 5
V / 2
3 0 V
A
R
p
a
p
t
ar e d
a
t i
u np
s u
d
c
t
p
onn
el
o
i v
w
e
e e
red
ct r :
e 4
d 00
f o
C
r
V
a
2
A
ll
4
3
/
0
M
V
i
-
x 1 0 0
V0
7
C 0 V
a
l
l
O n
0
l
y
8
M
i x O
0
n l
y 1 0
2
0
4 / 7
V 0
D
C
V
I
0
n 1 0 0
/ 7 0 V
0
W
a r n i n g
T h
i s a p p
ar a t u
s m u
s t b e
ea r t h
e d
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 13
Plena Mixer Amplifier | Installation and Operating Manual | en | 13
1
15V /2 30V
A
p
p
aratu
s
d
e
liv
e
red
con
ne
cte
d
f
or
230
V
-
Ra
te
dinp
u
t
p
owe
r:4
0
0
V
A
Thi
s
a
pp
aratus m
u
s
t
W
arni
n
g
Call/Mi
x
24VD
C
In
Cal
l
Only
Mi
x
O
n
l
y
70
V0
10
0
/70
V
0
100
/70
V
0
80
External settings and connections

4 External settings and connections

4.1 Connect the DC supply (battery)

T e l
/
L
Em
e
r .
0
R
0
C
2
D
O
u t
A
u x
L
i n e
In
O
u t
1
V
In
c
M
i c /L
i n
e
M
i c /
L i n
e
2
3
4
1 1
5 V
/ 2
3 0
V
A
R
p
a
p
t
ar
ed
a t
i
u
np
s
ut
d
c
p
onn
el
o
i v
w
e
ec
er
r ed
t
:
e
4
d
00
f o
C
r
V
a
2
A
l
3
l
/
0
M
V
i
-
x 1 00
V
0
7
C
0
V
a
l l O
n
0
l y
8
M
i x O
0
n l y
1
0
2
0
4
/
7
V
0
D
C
V
I
0
n 1 0 0
/ 7 0 V
0
Wa
r n i
n g
T h
i s a p
p ar
a t us
m
u
s t b
e e
a r t h
e d
-
12 V D C
C h
i m
e
1
-
­3
4
.5
1
+
-
F
LBB1903 (30W); F=F5A
+
LBB1906 (60W); F=F8A LBB1912 (120W); F=F15A LBB1914 (120W); F=F15A
12 V D C
Figure 4.1
The mixer amplifier has a 24 Vdc input (terminal screw), which you can use to connect a back up power supply, e.g. batteries. You can earth the unit to increase the electrical stability of the system.
Caution
The connection cable must have an in-line fuse. Use the type of fuse as mentioned in the illustration.

4.2 Priority microphone

T el
/Emer.
L
0
R
0
C
2
D
C
hime
1
-
­3
2
4
. 5
1
2
O
u
t
A
ux
Li
neOut 1V
In
In
c
Mic
/Li
n
e
Mi
c /
Li
n
e
3
4
Ca
ll / M
ix 1 00
V
07
0
V
0
8
115
V/2
30V
A
R
p
ated
par
a
t
i
u
nput
s
c
deli
po
onn
w
v
ec
er
e
r
ed
te
:40
d f
0V
or
A
2
30V
C
a l
0
10
0/70
-
lO
nl y
Mi
xO
nl
y
2
4 V D
V
C
0
I n
100/70V
0
Wa
rn
i n
g
T h
is
app
ar
atus
m
u
s t
b
eea
r
thed
Figure 4.2
Bosch Security Systems | 2003-09 | 3922 988 92883en
GND
GND
180 5 - po le D I N6.3 mm phono jack
180 3-pole X LR
Page 14
Plena Mixer Amplifier | Installation and Operating Manual | en | 14
External settings and connections
Microphone 1 input has a 5-pole DIN (for a 3 or 5-pole DIN microphone) and a 6.3-mm phone jack connector wired in parallel. Only when connecting a microphone with a priority contact on pin 4 and 5 of the 5-pole DIN connector (2), this input has priority over all inputs except the emergency input. This microphone input can be included with a voice controlled circuit (VOX) which will overrule all the other input signals. How to activate the VOX is described in §2.1.
Note
Only use one of the two connection possibilities of each microphone input.

4.3 Chime ON/OFF-switch

Te
l/
L
E
me
r .
0
R
0
C
2
1
D
C
h i
me
1
-
-3
4
. 5
1
2
O u
Au
t
x
L
in
e
I
O
n
u
t
1
V
I n
c
M
ic
/ L
i n
e
M
i c
/
L
i n
e
3
4
C
a
l l/ M
i
x 1 0
0 V
0
70V 0 1
8
1
1
5
V /
2
3
0
V
Ap
Rat
p
ar e d
a t
i
u
n
s
p
c
ut
d
power
onn
e
l i v
e
er
c
e
t
:
ed
d
4
00VA
f o
r23
0
C
a l
l
O n
l y
0
0 0/
70
V
0
V-
M
i x
O
nly
2 4
V
DC
In
1 0
0
/ 7
0 V0
W
a
rn
i
n
g
This
app
arat
u s
m
u
s
tbeea
r
t hed
Figure 4.3
Depending on the position of the chime ON/OFF-switch (1), switching on microphone 1 will activate the chime. The default chime volume is -8 dB (40 V), which will be sufficient in most applications. The volume can be altered using the potentiometer VR401 on the main PCB of the unit (see §2.3).
Note
Only when connecting a 5-pole DIN microphone to the 5-pole DIN connector of microphone input 1 the chime can be activated.
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 15
Plena Mixer Amplifier | Installation and Operating Manual | en | 15
2
1
3
4
Mic/Line
M
ic/Li
ne
C
D
L
R
A
ux
L
ineOut 1V
In
c
O
u
t
In
T
el
/
Eme
r
.
0
0
2
C
h
i
m
e
4
.5
1-
-3
2
1
CD
L
R
A
Tel /
E
mer
.
0
02
Ch
ime
4
.5
1- -3
External settings and connections

4.4 Microphone inputs

6 6
T el /
L
E m er. 0
R
0
C
2
D
Ou
t
C h
i m
A u
e
x
1
L
­i ne
-
3
In
O
u t
4
1
V . 5
In
c
M
i c / L
i
n
e
M
i c / L
i
1
n e
2
3
4
1
Figure 4.4
Dependent on the microphone choose between the XLR with Phantom power and the 6.3 mm phono jack connector. Use an extension cable (1) if necessary. When using input 3 or 4 to connect microphones, set the switches (6) to Mic. When using these inputs as line-inputs, set the switches (6) to Line. To cut-off the lower frequencies of the signal, activate the speechfilters on the PCB (see §2.2).
1
1 5
V /2
3 0
V
A
R
p
a
pa t e
r
d
a t
i
u
n
s
p
c
u
d
p
o
t
e
o
n
l i
w
n
v
e
e
e
c
r
r
e
te
:
d
4
d
0
f
0
o
C
V
r
a
A
2
l
l
3
/ M
0 V
i x
-
1
0 0 V0
7 0
C
V
a l l
On
0
l yMi
8
xOn
0
l
y 1 0
2
0
4
/
VD 7 0
V
C
0
I
n 1 0 0
/ 7 0
V 0
W
ar
n in
g
T
h i s
ap
p a r a
t u s
m u
s t b
e e
a rt h
e d

4.5 Emergency input

8
T
e l /E
L
m e
r .
0
R
0
C
2
D
O
u
C h ime
Figure 4.5
The emergency input is for emergency announcements/signals and obviously has the highest priority (all other inputs are overruled). The emergency volume -which cannot be affected by the master volume control (11) - can be set at 8, using a screwdriver. It can not be set to zero.
Caution
A connection to a telephone network must always be made via a telephone coupler that provides adequate isolation between the telephone network (PBX) and the Plena system. The telephone coupler must also meet all relevant requirements for this type of communication equipment as imposed by law and/or responsible
Bosch Security Systems | 2003-09 | 3922 988 92883en
telecommunication organisations in the country of use. Never try to make a direct connection between the telephone network and the mixer amplifier.
t
A u
x
1
L
-
in
-3
e
I
O
n
u
t
4
1
V . 5
I n
c
M
i c /
L i n
e
M i
c / L
i
1
n e
2
3
4
1
1 5 V/2
3 0
V
Ap R a
p t
a
e
r
d
atu i n
s p
co
u
d
p
t
e
o
n
l i
w
n
v
e
e
e
c
r
r:
e t e
d
4
d
0
f
0
o
C
V
r
a
A
2
l
l
3
/ M
0
V
i x
-
1 0 0 V0
7 0
C
V
a l l
O
01
n l
yM
8
i xOn
0
l y
00
2
4V / 7
DC
0
V 0
I
n 10 0
/ 7 0
V 0
W
a r
n i n g
T
h i s
a p p a
r a tu s
m u
s t b
e
ea rt h
ed
Page 16
Plena Mixer Amplifier | Installation and Operating Manual | en | 16
2
1
3
4
M
ic/L
in
M
i
c/Li
ne
C
D
R
A
u
x
L
i
n
eOut
1
V
I
n
c
Te
l
/
E
m
e
r
.
0
0
2
C
h
im
e
4. 5
1
-
-3
2
1
3
4
M
ic/Li
n
M
i
c/L
i
ne
CD
L
R
L
ine O
ut 1V
Inc
Te
l/
E
m
e
r.
0
0
2
Chime
4
.5
1
-
-3
External settings and connections

4.6 Music source inputs

10
CD
13
T
e l
/Em
L
e r .
0
R
0
C
2
D
O u
C h
i m e
1
-
­3
4
.
5
1
t
A u
x
L
i n
e
I
O
n
u
t 1 V
I
nc
M
i c /
L i n
e
M
i c
/ L i n
e
2
3
4
1 1
5 V /
2 3
0 V
A
R
p
a
p
t
a
e
r
d
a t
i
u
n
s
p
c
u
d
p
o
t
e
owe
n
l i
n
v
e
e
c
r
r
e
te
:
d
4
d
0
f
0
o
Ca
V
r
A
2
l
l
3
/ M
0 V
i x
1
00
-
V0
7
C
0 V0
a
l l O
n l y
8
M
i x
O n
0
l
y 1 0
24 0 /
VD
7 0 V
C
0
I
n 1 0 0 /
7 0
V 0
W a
r n i
n g
T h i sa
p
p a r a
t u
sm
u s t
b e
e a r
t h
e d
RECORD
PLAYBACK
LBB1961
P L
E N
A
B
G
M
s o
u
r c
e
P o w
e r
R e p
e a t
P r o
g r a m
F o
ld e r
CD
/
M
P 3
F M
/ A
M M 1
/ 6
M 2
/ 7
M
3 / 8
M
S
4
c
/ 9
a
n
M 5
/ 1 0
P r o
g
r
a
m
TUNE R
TAP
E
Figure 4.6
When using a CD player, tape recorder or tuner for background music, connect the line-out connectors of the music source to the appropriate line-in connectors of the mixer amplifier (e.g. the tape recorder must be connected to the tape source input (10)). When using a tape recorder to record the output of the amplifier, connect the line-in connectors of the tape recorder to the line-out connector (13) of the mixer amplifier.

4.7 Connecting the line output

12
Tel
/
L
E
mer
.
0
R
0
CD
2
C
hi
me
1
­4
Figure 4.7
The line output (12) is an output for connecting additional PA amplifiers (such as the Plena Booster Amplifiers).
Bosch Security Systems | 2003-09 | 3922 988 92883en
Ou
t
A ux
L
i n
­e
3
I
Out1
n
V . 5
I n
c
Mi
c / Line
M
ic /
L i
1
ne
2
3
4
1 15
V/
2 3
0 V
A
R
p
a
p
t
a
e
r
d
a
tu i n
s
p
c
u
d
p
o
t
e
owe
n
l i
n
v
e
e
ct
re
r:
e
d
4
d
0
f
0
o
C
V
r
a
A
2
l l
3
/
Mi
0
V
x
-
1 0
0 V
0
7
0
Ca
V
l l O
0
n
l y
8
M
i x O
n
0
l
y 1 0
24 0 /
V
7
DC 0 V
0
I
n 1 0 0
/ 7 0 V
0
W a
r n i
n g
Th i
s a p
pa r
a t us
m
us t be
e a
r th
e d
P
le
naBo
o
s
t
e
r
Am
p
l
if
ie
0
d
r
B
­6
d
B
­2 0
d
B
P
o we
r
Page 17
Plena Mixer Amplifier | Installation and Operating Manual | en | 17
External settings and connections

4.8 Connecting loudspeakers

LBB1903/10 LBB1906/10 LB B1912 /10
Call Only MixOnly
Call/Mix
100/70V
100V070V
0
100/70V
08
0
Call/Mix direct out 8 Ohm
LB B1914 /10
Zone1 Zone 2
Call/Mix
100/70V/8 0 100/70V 0 100/70V 0 100/70V0 100/70V0
Call Only Mi xOnly
8 Ohm
4Ohm
4Ohm
8Ohm
8Ohm
24VDCIn
0
8Ohm
8Ohm
24VDCIn
100V
LBB1903/10 LBB1906/10 LBB1912/10
JP901 100V
100V
70V
70V
8Ohm
0
70V
100V
8Ohm
0
Call Active
0
JP902 100/70
70V JP802
Z1 Front
8Ohm
T
e l
/
L
E me
r .
0
R
0
C
2
D
O
u t
C h
i m
A u
e
x
1
L
--
i n
e
3
I
O
n u t
4
1
V . 5
I n
c
M
i c
/ L i n
e
M i
c / L
i
1
n e
100V
0
2
3
4
1 1
5 V
/ 2 3
0 V
Ap
R
a
p
t
a
e
r
d
a t
i
u
n
s
p
c
ut
d
p
o
e
o
n
l i
w
n
v
e
e
e
c
re
r
t
:
e
d
4
d
0
f
0V
o
C
r
a
A
2
ll/
3 0
M
V
i
-
x
10
0 V
0
7
C 0 V
al
l O
0
n l y
8
M ix
O
0
n
l
y 1 0
2 0
4 V
/
70
D
V
C
I
0
n 1 0
0 /7
0
V 0
W a
r n i
ng
T h i
s a p
p a r
a t u
s m
u s t b
e e
a r th
e d
70V
0
8Ohm
100V070V
Call/Mix
0
Call Only MixOnly
100/70V
08
24VDCIn
100/70V
0
0
0
0
0
Call Only
0
Mix O nly
0
24V
+
24V
-
Call/Mix direct out
100V
Call/Mix
direct out
70V
Call Only 100/ 70 V
Mix Only 100/ 70 V
Figure 4.9
0
Call Only
0
0
Te
l /
L
E
me
r .
0
R
Call Only MixOnly
0
C
2
D
O u
t
C h
i m
A u
e
x
1
L
-­i n
e
3
I
O
n
u
t
4
1
V . 5
I n
c
M
i c
/ L
i n e
M
i c / L
i
1
n
e
2
3
4
1 1
5 V
/ 2 3
0
V
A
R
p
a
p
t
a
e
r
di
a
t u
np
s
c
ut
d
p
o
e
o
n
l
iv
w
n
e
e
e
c
re
r
t
C
:
e
d
a
4
d
ll/
0
f
0
o
M
V
r
ix
A
2 3
0 V
-
1 0
0 V
0
C a ll
7
0
O
V
n l y
0
Mi
x
8
O n
l y
2
0
4V
1
D
0
0
C / 7
I
n 0 V
01
0 0 /
7 0 V 0
W
ar ni
ng
Th
i s a
p p a
ra t u
s m
u s
t b e
e a r t
h e d
24VDCIn
Zone 1 Call/Mix
0
0
Zone1 Zone 2
Call/Mix
0
0
Call/Mix
100/70V/8 0 100/70V 0 100/70V 0 100/70V 0 100/70V 0
8 Ohm
4 Ohm
4 Ohm
8 Ohm
8 Ohm
Call/Mix direct out 8 Ohm
8 Ohm
8 Ohm
Figure 4.8
LBB1914/10
0
Z2 Front
Call Active
Zone 2 Call/Mix
0
0
0
24V
Mix O nly
0
0
+
24V
-
Call/Mix direct out 100/ 70 V
Zone 1
100/ 70 V
Zone 2
100/ 70 V
Call Only 100/ 70 V
Mix Only 100/ 70 V
Figure 4.10

4.8.1 Constant voltage loudspeakers

The mixer amplifier can drive 100 V constant voltage loudspeakers at full power (100 V) or half power (70 V). Connect the loudspeakers in parallel and check the loudspeaker polarity for in-phase connection. The summed loudspeaker power should not exceed the rated amplifier power. Ensure that the jumper(s) for loudspeaker voltage selection is / are properly set (see §2.4).
You can use the Call Only output for 3-wire remote volume control override. In this case, ensure that the selected voltage for the Call Only output is the same as for the direct output or the zone outputs.
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 18
Plena Mixer Amplifier | Installation and Operating Manual | en | 18
1
1
5V/230V
Appa
r
atus d
e
live
r
e
d
c
o
n
ne
c
te
d
fo
r2
30
V-
Ra
t
ed inp
u
t
p
o
we
r
:
4
00V
A
Thi
s
a
p
pa
ra
tus
m
us
tb
e
ea
r
thed
Wa
r
nin
g
I
GN
&
QUALIT
Y
S
H
O
L
LAND
2
4
VD
CI
n
Call
O
n
ly M
ix
Only
/
70V
0
1
00
/
70V
0
External settings and connections

4.8.2Low impedance loudspeakers

Connect low impedance loudspeakers to the 8 Ohm/0 terminals. This output can deliver the rated output power into an 8 Ohm load. Connect multiple loudspeakers in a series/parallel-arrangement to make the combined impedance 8 Ohm or higher. Check the loudspeaker polarity for in-phase connection. Ensure that the jumper(s) for loudspeaker voltage selection is / are properly set (see §2.5).

4.9 Mains connection

Tel
/
L
E
m e r
.
0
R
0
C
2
D
O
u
C hi
m
e
1-
­3
4
.5
1
t
A u
x
Line
In
Ou
t 1V
I
nc
M
i c/
L i
n e
M
i c/
L i
n e
2
3
4
11
5 V
/23
0 V
A
R
p
a
p
t
a
e
ra
d
t
in
u s
p
c
u
d
p
o
t
e
o
n
li
w
n
v
e
e
e
c
re
r
t
:
e
d
4
d
0
f
0
o
C
V
r
a
A
2
l
l
3
/M
0
V
i
x 1 0
0V
07
-
0
Ca
V
l l O
0
n l
y
8
Mi
x O
n
0
l
y 1 00
2 4
/
V
70
D
V
C
0
I
n
100
/70
V
0
W
a
rn i
n g
Thi
s a p
p a r
a t u
s mu
s tb
e
e a
r t h
e d
Figure 4.11
Use the supplied mains cord to connect the system to the mains supply.
Note
If necessary set the switch 115/230 V to the required voltage using a sharp object, e.g. a small screwdriver.
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 19
Plena Mixer Amplifier | Installation and Operating Manual | en | 19
Operation of mixer amplifier

5 Operation of mixer amplifier

2
Plena Mixer Amplifier
0dB
-6 dB
-20 dB
Power
3
1
3
4 8 9
2
4
Select
CD AUX
Line
Only for LBB1914/10
Master Zone 1 Zone 2
Figure 4.6
Use the supplied mains cord to connect the system to the mains supply.
1
5 6 7 10 11 12 13
Figure 5.1

5.1 Source selection

Use the music source selector (8) to select one of the connected music sources.
Use the input volume controls (3, 4, 5, 6 and 7) to balance the sound level of the microphone inputs and the background music.

5.2 Volume and tone control

Use the master volume control (11) to control the volume of the music/microphone mix.
The treble and bass tone controls (9 and 10) affect the microphones as well as the music.

5.3 Zone selection (LBB1914/10 only)

Use the zone selection buttons (12 and 13) to route the music/microphone mix from the amplifier output to loudspeaker zone 1 and/or loudspeaker zone 2. Priority announcements, however, are always routed to both zones, irrespective of the position of the zone selection buttons.
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 20
Plena Mixer Amplifier | Installation and Operating Manual | en | 20
Tec hn ic al da ta

6 Technical data

6.1 Electrical

Mains voltage 230/115 Vac, ±10%, 50/60 Hz Max mains power consumption
LBB1903/10 100 VA LBB1906/10 200 VA LBB1912/10, LBB1914/10 400 VA
Max mains inrush current
LBB1903/10 4.5 A/9 A (230/115 Vac) LBB1906/10 5 A/10 A (230/115 Vac)
LBB1912/10, LBB1914/10 8 A/16 A (230/115 Vac) Battery voltage 24 Vdc, +20%/-10% Max battery current
LBB1903/10 1.6 A LBB1906/10 3 A LBB1912/10, LBB1914/10 6 A

6.2 Performance

Frequency response 50 Hz - 20 kHz (+1/-3 dB @ -10 dB ref. rated output) Distortion < 1% @ rated output, 1 kHz Bass control -8/+8 dB @ 100 Hz Treble control -8/+8 dB @ 10 kHz

6.3 Inputs

Input 1 (5-pin DIN, balanced with phantom power, 6.3 mm phone jack) Input 2 (3-pin XLR, balanced with phantom power, 6.3 mm phone jack)
Sensitivity 1 mV Impedance > 1 kOhm S/N (flat at max volume) 63 dB S/N (flat at min volume/muted) > 75 dB CMRR > 40 dB (50 Hz - 20 kHz) Headroom > 25 dB Speech filter -3 dB @ 315 Hz, high-pass, 6 dB/oct Phantom power supply 16 V via 1.2 kOhm VOX (input 1 only) attack time 150 ms
release time 2 s
Input 3 and 4 (3-pin XLR, balanced with phantom power, 6.3 mm phone jack)
Sensitivity 1 mV (microphone), 200 mV (line) Impedance > 1 kOhm (microphone)
> 5 kOhm (line) S/N (flat at max volume) 63 dB (microphone), 70 dB (line) S/N (flat at min volume/muted) 75 dB CMRR > 40 dB (50 Hz - 20 kHz) Headroom > 25 dB Speech filter -3 dB @ 315 Hz, high-pass, 6 dB/oct Phantom power supply 16 V via 1.2 kOhm (microphone)
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 21
Plena Mixer Amplifier | Installation and Operating Manual | en | 21
Music input (Cinch, stereo converted to mono)
Sensitivity 200 mV Impedance 22 kOhm S/N (flat at max volume) > 70 dB S/N (flat at min volume/muted) > 75 dB Headroom > 25 dB
Emergency / telephone (Screw, balanced)
Sensitivity 100 mV - 1 V adjustable Impedance > 10 kOhm VOX threshold 50 mV
attack time 150 ms
release time 2 s S/N (flat at max volume) > 65 dB
Interconnection (Cinch)
Nominal level 1 V Impedance > 10 kOhm
Tec hn ic al da ta

6.4 Outputs

Master output 1 (3-pin XLR, balanced)
Nominal level 1 V Impedance < 100 Ohm
Tape output (Cinch, 2x mono)
Nominal level 350 mV Impedance 1.5 kOhm
Interconnection (Cinch)
Nominal level 1 V Impedance < 100 Ohm
Loudspeaker outputs (Screw, floating)
Max/rated output power 70/100 V
LBB1903/10 45 W/30 W LBB1906/10 90 W/60 W LBB1912/10, LBB1914/10 180 W/120 W
8 Ohm output
LBB1903/10 16 V (30 W) LBB1906/10 22 V (60 W) LBB1912/10, LBB1914/10 31 V (120 W)
Output power @ 24 V battery operation -1 dB ref. rated power

6.5 Environmental conditions

Operating temperature range -10 to +45 °C Storage temperature range -40 to +70 °C Relative humidity < 95%
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 22
Plena Mixer Amplifier | Installation and Operating Manual | en | 22
Tec hn ic al da ta

6.6 General

EMC emission acc. to EN 55103-1 EMC immunity acc. to EN 55103-2 Acoustic noise level of fan < 40 dB SPL @ 1 m (LBB1912/10 and LBB1914/10 only) Dimensions 100 x 430 x 270 mm (19 wide, 2U high) Weight
LBB1903/10 approx. 5 kg LBB1906/10 approx. 8.5 kg LBB1912/10, LBB1914/10 approx. 10.5 kg
19 mounting brackets LBC1901/00 (to be ordered separately)
Bosch Security Systems | 2003-09 | 3922 988 92883en
Page 23
Page 24
For more information visit
www.boschsecuritysystems.com
© Bosch Security Systems B.V.
Data subject to change without notice
2003-09 | 3922 988 92883en
Loading...