ATP10 and ATP35

Attenuators with Bypass for 25V/70V Speaker Line

Installation and Use Manual

ATP10 ATP35

Description

These 10-step plus “OFF” speaker attenuators allow the volume of a network of 25V or 70V speakers to be controlled from a remote location. The ATP10 attenuator can handle speaker loads of up to 10W (max.) and the ATP35 attenuator can handle speaker loads of up to 35W (max.). The ATP10 fits into a single gang electrical box and the ATP35 attenuator fits into a double gang electrical box.

Each unit includes a bypass function for overriding the volume control knob setting when activated by 9V to 30V DC. Applying 9V to 30V DC between pins labeled D+ and D- bypasses the volume control function and provides full volume audio to the speakers.

 

Power Supply

Customer Supplied

Attenuator Wiring

9V - 30V DC

Contact Closure

 

 

 

 

ATP10 (or ATP35)

 

 

_

+

 

Pin Connections

_

Amplifier

 

 

 

 

+

SPEAKER

 

 

OUTPUTS

_

+

 

 

 

Rear

 

Speaker

View

 

_

+

S+ Speaker Load Hot

S- Speaker Load COM

A+ Amp Hot

A- Amp COM

D+ +9V to 30V DC @ 22mA

D- Gnd DC

© 2005 Bogen Communications, Inc. All rights reserved.

Specifications subject to change without notice. 54-2149-01E 1202

Attenuator

Settings

STEP

ATTENUATION

10

0 dB (Full Volume)

 

 

9

-3 dB

 

 

8

-6 dB

 

 

7

-9 dB

 

 

6

-12 dB

 

 

5

-15 dB

 

 

4

-18 dB

 

 

3

-21 dB

 

 

2

-27 dB

 

 

1

-33 dB

 

 

0

Speaker Off

 

 