Blu Bathworks TEP431 User Manual

pure·2 electronica
in-wall thermostatic tubfiller
with handshower & hose
Installation Guide
TEP431
2013-12
®
1 866 907 0122 blubathworks.com
Attention – Before Installation
1. Inspect this product to ensure you have all parts as shown that are required for proper installation.
2. The valve cartridge has been factory tested and adjusted – DO NOT TAKE THE CARTRIDGE APART. Taking the cartridge apart will void the warranty.
3. Ensure that both hot and cold water feeds are properly connected to the marked lav connecting.
4. This product must be installed by a professional contractor.
5. Refer to the specification and assembly drawings attached for installation directions.
6. Flow Pressure –Min. 25 PSI, Max. 80 PSI. Recommended pressure – 50 to 60 PSI.
Installation Requirements
Please read the instructions carefully so as to avoid any damage to the fixture.
1. To ensure this product is installed properly, you must read and follow these guidelines.
2. The owner/user of the faucet must keep this information for future reference.
3. Be sure your installation conforms to local codes.
4. Refer to the specification and assembly drawings attached. Faucet is sold partially assembled but shown fully disassembled for illustrative and service purposes only.
5. Inspect this product to ensure you have all parts required for proper installation.
6. Use only a strap wrench or protected/smooth-jaw wrench on any finished surface.
7. If possible, install the faucet assembly on the sink or mounting surface before setting.
8. Do NOT use putty during this installation.
Cleaners For Fittings And Accessories
To avoid damaging the surface and working components of the fittings, certain precautions must be taken in terms of us­age and subsequent cleaning as many cleaning agents contain acids for general cleaning and removing calcium depos­its. When caring for your fittings and accessories, please note the following:
- Only apply cleaners which are expressly intended for the use
- Never use any cleaner containing hydrochloric acid, formic acid or acetic acid on or near the fitting, as they can
cause considerable damage
- Do not use cleaners containing phosphoric acid
- Do not use cleaners containing chlorine bleach solutions
- Never mix or combine cleaning agents
- Abrasive cleaners and unsuitable scouring agents such as scouring pads
Technical Support Assistance
If further assistance is required, please contact:
Product support at 1.866.907.0122 (09:00 - 17:00hrs PST) or email
technical@blubathworks.com
North America
Blu Bathworks Inc. 188 Smithe Street, Vancouver BC, Canada, V6B 6A9 T+1.604.299.0122 F+1.604.299.0125
2013-12
®
1 866 907 0122 blubathworks.com
Step 1 - Bathtub spout
1) Screw the rod (1) on the pipe (2).
2) Place the foam gasket (3) on the back part of the plate (4).
3) Place the plate (4) on the finished wall.
Step 2 - Bathtub spout
4) Place the O-ring (5) on the spout (6).
5) Place the spout (6) on the rod and fix it with the grub screw (7).
2013-12
®
1 866 907 0122 blubathworks.com
Step 3 - Handshower
1) Screw the rod (1) on the pipe (2).
2) Slide the holder on the rod & fix with grub screw (7).
3) Attach the hose to the handshower.
7
Step 4 - Two outlet shower/tub control
Please refer to steps 1-9 below
®
2013-12
1 866 907 0122 blubathworks.com
Step 1 - Assembly of the Control Fixing Bracket to the In-wall Plate
Finish the wall by tiling or using drywall. Using the trim plate, the control fixing brackets must be positioned using the supplied in-wall rough-in plate with their centres 70mm apart.
40mm diameter holes are required
Conduits should be used in the walls where necessary to protect the cables and allow maintenance.
Attach the control fixing brackets using the four small screws supplied in the plastic bagset for the control fixing brackets.
Step 2 - In-wall Rough In Plate
Finish the wall by tiling or using drywall.
®
Step 3
Draw a line around the bracket collars, flush with the wall.
2013-12
1 866 907 0122 blubathworks.com
Step 4
Cut down the bracket collars as marked.
Step 5
a.
a: Install the supplied seal on the back of the trim plate.
b.
adaptor ring
a
b: Position the adaptor rings inside the plate and fix through the adaptor ring holes into the bracket collar using 15mm screws supplied (manually.)
Note: Do no use an electric drill.
c.
c
c: Position and fix the trim plate in position on the wall before tightening the four screws.
2013-12
®
1 866 907 0122 blubathworks.com
Loading...
+ 13 hidden pages