Blodgett SB-10SC Installation Manual

SB-6SC, SB-10SC and SB-16SC
CONVECTION STEAMER ON A STEAM COIL BOILER BASE
INSTALLATION – OPERATION – MAINTENANCE
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 658-6600 Fax: (802) 864-0183
S00060 Rev B (12/04)
1
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.
CAUTION: Operating, testing, and servicing should only be performed by qualified personnel.
NOTICE: Contact the factory, the factory representative or local service company to perform maintenance and repairs.
Intended for commercial use only. Not for household use.
This manual should be retained for future reference.
It is recommended that this manual be read thoroughly and that all instructions be followed carefully.
2
TABLE OF CONTENTS
DESCRIPTION PAGE
Important Notes ....................................................................................................... 2
Service Connections ............................................................................................... 4
Introduction ............................................................................................................. 5
1.0 Installation Instructions ..................................................................................... 6
2.0 Information to Steam Fitter ............................................................................... 8
3.0 Operating Instructions ...................................................................................... 10
4.0 Periodic Maintenance ....................................................................................... 12
5.0 Cleaning Instructions ........................................................................................ 14
6.0 Troubleshooting................................................................................................ 16
3
SERVICE CONNECTIONS
S
ELECTRICAL CONNECTION: 1/2" conduit connection to controls. 120VAC-60Hz-1PH2 AMPS per compartment or to be as specified on data plate.
DRAIN: 2"IPS piped to open floor drain. No Solid Connection.
COLD WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa).
STEAM SUPPLY: 3/4" female pipe connection for 25-50 PSI(170-345 kPa).
Total dissolved solids
Chlorine
Silica
pH Factor
Total alkalinity
local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
Water which fails to meet these standards should be treated by installation of water conditioner.
7.0-8.5
Less than 1.5 PPM
Less than 13 PPM
WATER QUALITY STATEMENT
Less than 20 PPM
Less than 60 PPM
* Pressure reducing valve is required if incoming pressure exceeds 50 PSI(345 kPa).
REAR FLANGED FOOT DETAIL
7/16" [11mm]
HOLES ON 2.5 [63] B.C.
2 EQUALLY SPACED Ø
2 [51]
2.75 [70]
3.5 [89]
24 [610]
33 [838]
16.75 [425]
1.5 [38]
9.5 [241]
10 [254]
27.63 [702]
25 [635]
S
SB-6SC & SB-10SC TOP VIEW SB-16SC TOP VIEW
5.5 [140]
0 [0]
10 [254]
2.5 [64]
24.75 [629]
33 [838]
29.75 [756]
S
6 [152] SB-16SC
5.75 [146]
8.75 [222]
28 [711]
55.5 [1410] SB-6SC
68.50 [1740] SB-10SC
67 [1702] SB-16SC
DIMENSIONS ARE IN INCHES [MM]
0 [0]
10 [254]
18 [457] SB-6SC & SB-10SC
4
INTRODUCTION
DESCRIPTION
Models SB-6SC and SB-10SC convection steamers mounted on 24” cabinet base and a steam coil boiler. An optional 36” cabinet is available for these models. Model SB-16SC
convection steamers mounted on 36” cabinet base and a steam coil boiler. All bases are designed to ASME Code and approved as a steam boiler restricted to operation at pressure not to exceed 15 psi. SB-6SC steamer has a pan capacity of 6 (2-1/2") pans. SB-10SC has a pan capacity of 10 (2-1/2") pans. SB-16SC has a pan capacity of 16 (2­1/2") pans.
BASIC FUNCTION: The sequence of operation is as follows:
1. Turn on main power switch. Pilot light will indicate main power is on and steam generating will begin. In approximately 20 minutes, sufficient amount of pressurized steam will have been generated in the heat exchanger and ready pilot light will come on. OFF shuts off the steam supply to the boiler and opens the automatic blowdown valve, if so equipped, emptying the boiler and releasing water and steam to the drain. The manual blowdown valve will have to be opened to drain if not equipped with automatic blowdown valve.
2. Boiler pressure gauge should read 9 - 11 psi during operation, 0 psi during shutdown.
3. Compartment cooker is ready for use when READY light is on. Place pans of food to be cooked into compartment(s) and close door(s).
4. Set timer(s) to cook time desired. Cooking will commence and cooking time may be interrupted at any time by opening door(s) and resumed again by closing door(s).
5. Buzzer will sound indicating the end of the cooking cycle and that steam has stopped entering the compartment(s). The COOKING pilot will go off and the READY light will come on. Buzzer must be shut off by turning the timer(s) to its off position.
5
1.0 INSTALLATION INSTRUCTIONS
UNPACKING
Immediately after unpacking, check for possible shipping damage. If the appliance is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery. Before installing, verify the electrical rating agrees with the specification on the rating plate.
LOCATION
Position the appliance in its installation location. Check that there are sufficient clearances to service the controls, door swing, etc. Also adequate clearance must be left for making the required supply and drain connections.
Allow enough space between any other piece of equipment or wall for service access. Service to the controls may be required on the left and/or right side panels of the cabinet.
INSTALLATION CODES AND STANDARDS
The appliance must be installed in accordance with: In Canada: Provincial and local codes, or in the absence of local codes, with the Canadian Electric
Code, CSA C22.1 (latest edition). Copies may be obtained from the Canadian Standard Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada, M9W 1R3.
In the U.S.A.:
State and local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA, 02269.
6