Blizzard Pipeline Twin Users Manual

DMX-512
DISTRIBUTOR
TM
Blizzard Lighting, LLC
www.blizzardlighting.com
Waukesha, WI USA Copyright (c) 2015
1. GETTING STARTED
What’s In The Box?
• 1 x Pipeline™ Twin
• This Lovely User Manual
Getting It Out Of The Box
Thank you for selecting the Pipeline™ Twin! This unit is a DMX distributor, signal amplier,
and isolator which allows you to split a DMX signal into 4 separate electronically isolated outputs. It also will boost your DMX signal for any extensive cable runs between DMX
lighting xtures.
Now that you’ve got your Pipeline™ Twin (or hopefully, Twins), you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition. If anything looks as if it has been damaged in transit, notify the shipper immediately and keep the packing material for inspection. Again, please save the carton and all packing
materials. If a xture must be returned to the factory, it is important that the xture be
returned in the original factory box and packing.
Caution!
There are no user serviceable parts inside this unit. Do not open the housing or attempt any repairs yourself; doing so will void your manufactures 2-year limited warranty. In the unlikely event your unit may require service, please contact Blizzard Lighting at www.blizzardlighting.com/support.
Safety Guidelines
• This unit is intended for indoor use only!
• All units must be connected to circuits with suitable Earth Ground.
To prevent risk of re or shock, do not expose unit to rain or moisture.
• The unit must be installed in a location with adequate ventilation. Be sure no ventilation vents are blocked.
• Make sure power cord is never crimped or damaged
• There are no user serviceable parts inside.
• Never connect unit to a dimmer pack.
Getting A Hold Of Us
If something is wrong, just please visit our website and open a support ticket. We’ll be happy to help, honest.
Blizzard Lighting N24W23750 Watertown Rd. Suite B Waukesha, WI 53188 USA www.blizzardlighting.com
Disclaimer: The information and specications contained in this document are subject to change without
notice. Blizzard Lighting™ assumes no responsibility or liability for any errors or omissions that may appear in this user manual. Blizzard Lighting™ reserves the right to update the existing document or to create a new document to correct any errors or omissions at any time. You can download the latest version of this document from www.blizzardlighting.com.
Author: Date: Last Edited: Date:
J. Thomas 10/14/2015 J. Thomas 11/3/2015
Pipeline Twin™ User Manual - Rev. A (c) 2015 Blizzard Lighting, LLC
2. MEET THE PIPELINE™ TWIN
MAIN FEATURES:
DMX signal amplier and distributor
• 1 input to 4 outputs, plus DMX thru
• Electronic isolation between inputs and outputs
• Terminator button for the last unit
• Signal input and output: 3/5-pin DMX
• Power and signal indicator
OVERVIEW:
Front View:
Power DMX In DMX Thru DMX Out 1-4
Terminator / Pass Thru
Rear View:
SPECIFICATIONS:
• 110-240VAC, 50-60Hz
• 10.9 x 5.7 x 2.76 in. (277 x 145 x 70 mm)
• Weight: 4 lbs. (1.8 kg)
• Fuse: F1A
PowerFuse
1= Ground 2= Data ­3= Data + 4= Not used 5= Not used
Connection Diagram
The physical signals of DMX 512 are transmitted using shielded twisted pair wire.
Do not exceed 32 units per one output channel and use a terminator on the last unit.
Pipeline Twin™ User Manual - Rev. A (c) 2015 Blizzard Lighting, LLC