Beretta IDRA MS 200, IDRA MS 300, IDRA MS 550, IDRA MS 430 Installation And Operation Manual

0 (0)
Installation and Operation Manual
Solar | solar storage cylinder
IDRA MS
Installation and Operation Manual
EN
2
This manual, Code 20058916 - Rev. 5 (12/16) comprises 16 pages.
3
Dear Customer, Thank you for choosing a B solar storage cylinder. You have purchased a modern, quality product that is designed to give dependable and safe service and to provide comfort in the home for many years to come. Arrange for your B solar storage cylinder to be serviced regularly by an authorised
B service centre. Their personnel are specially
trained to keep your solar storage cylinder efficient and cheap to run. B service centres also stock any original spare parts that might be required. This manual contains important instructions and precautions that must be observed to ensure the trouble-free installation and efficient functioning of your
B solar storage cylinder.
Please accept our renewed thanks for your purchase,
Beretta
CONFORMITY
B storage cylinders conform to DIN 4753-3 and UNI EN 12897 standards.
b
This product must only be used for the purpose for which it is designed and made, as specified by B. B declines all responsibility, contractual or other, for damage to property or injury to persons or animals caused by improper installation, adjustment, maintenance or use.
RANGE
MODEL CODE
IDRA MS 200 BERETTA 20015324 IDRA MS 300 BERETTA 20015328 IDRA MS 430 BERETTA 20015333 IDRA MS 550 BERETTA 20015340
ACCESSORIES
For a complete list of accessories and details of their compatibility, refer to the Catalogue.
CONTENTS
The following symbols are used in this manual:
b
CAUTION! =
Identifies actions that require caution
and adequate preparation.
a
STOP! =
Identifies actions that you MUST NOT do.
This manual, Code
- Rev. comprises pages.
GENERAL ..................................4
1 General Safety Information ..................4
2 Precautions .............................. 4
3 Description of the appliance.................5
4 Identification ............................. 5
5 System layout ............................ 5
6 Technical specifications ....................6
7 Water circuit .............................7
8 Location of sensors........................ 8
9 Overall dimensions and water fittings..........9
INSTALLER ................................11
10 Unpacking the product .................... 11
11 Handling ............................... 11
TECHNICAL ASSISTANCE CENTRE ............12
12 Place of installation ....................... 12
13 Installation in older systems and systems
requiring modernisation ................... 12
14 Putting into service ....................... 12
15 Temporary shutdown...................... 13
16 Preparing for extended periods of disuse .....13
17 Maintenance ............................ 13
18 Cleaning and removing internal components...13
20 Troubleshooting.......................... 14
19 Recycling and disposal ................... 14
END USER .................................15
21 Start-up ................................ 15
22 Temporary shutdown...................... 15
23 Preparing for extended periods of disuse .....15
24 External maintenance .....................15
4
GENERAL
1 GENERAL SAFETY INFORMATION
b
Check that the product is complete, undamaged and as ordered as soon as you receive it. Report any discrepancies or damage to the B dealer who sold it.
b
This product must be installed by a legally qualified heating engineer. On completion of the installation, the installer must issue the owner with a declaration of conformity confirming that the installation has been completed to the highest standards in compliance with the instructions provided by
B in this instruction
manual, and that it conforms to all applicable laws and standards.
b
This product must only be used for the purpose for which it is designed and made, as specified by
B. B declines all responsibility, contractual or
other, for damage to property or injury to persons or animals caused by improper installation, adjustment, maintenance or use.
b
The product must be serviced at least once a year. Servicing must be arranged in advance with the
B Technical Assistance Centre.
b
All servicing and repairs must be performed by a qualified heating engineer.
b
If water leaks from the storage cylinder, turn off the water supply and contact B’s Technical Assistance Centre or a qualified heating engineer immediately.
b
If the solar storage cylinder is not going to be used for an extended period of time, contact the manufacturer’s Technical Assistance Centre to have at least the following operations performed:
- Close the shut-off cocks for the domestic hot water circuit
- Shut down the boiler connected to the storage cylinder as instructed in its own manual
- Switch the storage cylinder OFF at the control panel (if fitted) and at the mains power switch
- Drain the central heating circuit and domestic hot water circuit if there is any risk of freezing.
b
Anti-freeze (propylene glycol) is available separately and must be mixed with water in a percentage varying from 30% to 50% as instructed in the installation and maintenance manual for the
B solar collectors.
b
Only fill the solar collector (primary) circuit with water and glycol premixed in the percentages specified in the B installation and maintenance manual.
b
This instruction manual is an integral part of the product. It must be kept safe and must ALWAYS accompany the product, even if it is sold to another owner or transferred to another user or to another installation. If you lose this manual, order a replacement immediately.
2 PRECAUTIONS
The operation of any appliance that uses electrical power demands that a number of fundamental safety precautions be respected. In particular:
a
Never attempt to install the system without using suitable personal protection equipment and without following all applicable occupational safety standards.
a
Do not touch the storage cylinder when barefoot or wet if it has any electrical accessories connected to it.
a
Never clean or service the storage cylinder without first turning the mains power switch OFF to disconnect all electrical accessories (if fitted) from the mains electricity supply.
a
Never pull, disconnect, or twist any electrical cables coming from the appliance even if it is disconnected from the mains electricity supply.
a
Do not expose the storage cylinder to the elements. It is not designed for use outdoors.
a
If the pressure in the solar collector circuit drops, do not top up with water alone, since this increases the risk of damage from freezing.
a
Do not use connections or safety devices or fittings (expansion vessels, pipes, insulation) that are not specifically designed and tested for use in solar water heating systems.
a
Do not allow children or infirm persons to operate the system unsupervised.
a
Do not dispose of packaging material into the environment, or leave it within the reach of children, since it can become a potential hazard. Dispose of packaging material in compliance with applicable legislation.
General
5
GENERAL
3 DESCRIPTION OF THE
APPLIANCE
B
IDRA MS
solar storage cylinders come in capacities of 200, 300, 430 and 550 litres, and are designed for integration in solar domestic hot water production systems heated by Bsolar collectors.
The most important technical features of these solar storage cylinders are:
- The storage cylinder and coil are specially designed and shaped for optimum performance in terms of stratification, heat exchange and replenishment times
- Internal glazing, bacteriologically inert, to ensure the maximum hygiene of treated water, reduce limescale deposits and make cleaning operations easier
- CFC-free polyurethane insulation and an elegant external casing reduce heat loss and improve efficiency
- Temperature sensor and power cables are all internally routed
- A flange is provided for easy cleaning and maintenance of the anti-corrosion magnesium anode.
B
IDRA MS
solar storage cylinders can be equipped with a special solar controller for easy integration in B solar water heating systems.
4 IDENTIFICATION
B
IDRA MS
storage cylinders are identified by:
Data plate
This lists the technical specifications and performance of the product.
Beretta Caldaie Via Risorgimento, 13 23900 Lecco (LC)
Beretta Caldaie Via Risorgimento, 13 23900 Lecco (LC)
INTERACUMULADOR SOLAR
Modelo
N° Fabric.
Código
Año
Pressão máxima de exercício
Alimentaçcao eléctrica
bar
V-Hz
Capacidade do termoacumulador
l
T067659EPE02
Conexión a tierra obligatoria - Ligação á terra obrigatória - Obligatory ground connection
W
Potência eléctrica consumida
Potência consumida max.pela serp.sup. [T° Primário 80°C]
kW
Caudal especifico sup. [T 35°C]
l/1'
TERMOACUMULADOR SOLAR
Ano
Potencia absorbida max.serp.sup. [T° Primário 80°C]
Presión máxima de funcionamiento
Capacidad del interacumulador
Potencia eléctrica absorbida
Alimentación eléctrica
m
2
Superficie serpentín superior Superfície serpentina superior
Superficie serpentín inferior Superfície serpentina inferior
m
2
kW
Pot. cons. max.pela serp.sup.
N° Fabric.
Pot. absor. max.serp.sup.
Modelo
m
2
Sup. serpentín inf. Sup. serpentina inf.
SOLAR STORAGE CYLINDER
Model
Serial number
Code
Year
Power absorbed by top coil (T° primary 80°C)
Domestic Hot Water production - top coil
Maximum working pressure of storage cylinder
Storage cylinder capacity
Electrical consumption
Power supply
Top coil heat exchange surface area
Bottom coil heat exchange surface area
Bottom coil heat exch. surf. area
Serial number
Model
Power absorbed by top coil
Serial number plate
This specifies the serial number and model.
b
If these plates or any other means of clearly identifying the product are defaced, removed or lost, proper installation and servicing may be rendered difficult.
5 SYSTEM LAYOUT
1
2
3
4
5
6
7
11
10
9
8
1
Magnesium anode
2
Storage cylinder
3
Temperature gauge
4
Sleeve for electric heating element (not supplied)
5
Coil
6
Flange cover
7
Cylinder inspection flange
8
Sensor socket
9
Insulation
10
Cover
11
Plug for anode inspection and lifting
Loading...
+ 11 hidden pages