2
GENERAL INFORMATION
RANGE
MODEL CODE
IDRA DS 200 20117881 IDRA DS 300 20117882 IDRA DS 430 20117883 IDRA DS 550 20117884 IDRA DS 750 20117885 IDRA DS 1000 20117886
ACCESSORIES
For a complete list of accessories and details of their compatibil
-
ity, refer to the Catalogue.
Dear heating engineer, We would like to congratulate you on having recommended a
B solar storage cylinder unit: a modern product that's ca-
pable of ensuring a high degree of reliability, efciency, quality
and safety. While your technical skills and knowledge will certainly be more
than sufcient, this booklet contains all the information that we
have deemed necessary for the device's correct and easy in
-
stallation.
Thank you again, and keep up the good work,
Beretta
CONFORMITY
The B solar heaters comply with DIN 4753-3 and UNI EN
12897.
CONTENTS
ENGLISH
1 GENERAL SAFETY INFORMATION
b
Check that the product is complete, undamaged and as ordered as soon as you receive it. Report any discrepan
-
cies or damage to the B dealer who sold it.
b
This product must be installed by a legally qualied heat­ing engineer. On completion of the installation, the install­er must issue the owner with a declaration of conformity
conrming that the installation has been completed to the
highest standards in compliance with the instructions pro­vided by B in this instruction manual, and that it con­forms to all applicable laws and standards.
b
This product must only be used for the purpose for which it is designed and made, as specied by B. B de- clines all responsibility, contractual or other, for damage to property or injury to persons or animals caused by improp­er installation, adjustment, maintenance or use.
b
The product must be serviced at least once a year. Servic­ing must be arranged in advance with the B Technical Assistance Centre.
b
All servicing and repairs must be performed by a qualied
heating engineer.
b
If water leaks from the storage cylinder, turn off the water supply and contact B’s Technical Assistance Centre
or a qualied heating engineer immediately.
b
If the product is not going to be used for an extended period of time, contact the manufacturer’s Technical As­sistance Centre to have at least the following operations performed:
- Close the shut-off cocks for the domestic hot water circuit
- Shut down the boiler connected to the storage cylinder as instructed in its own manual
- Switch the storage cylinder OFF at the control panel (if
tted) and at the mains power switch
- Drain the central heating circuit and domestic hot water circuit if there is any risk of freezing.
b
This instruction manual is an integral part of the product. It must be kept safe and must ALWAYS accompany the product, even if it is sold to another owner or transferred to another user or to another installation. If you lose this man
­ual, order a replacement immediately. Keep the product purchase documents to be presented to the B author­ised Technical Assistance Centre to request a service call under warranty.
b
Size the solar expansion tank so as to ensure complete
absorption of the expansion of the uid contained within
the system, with reference to the prevailing regulations on
the matter. In particular, consider uid characteristics, con­siderable uctuation of service temperature and vapour
that might be generated during solar collector stagnation stage. Proper size of expansion tank ensures setting off
of all volume changes of the heat transfer uid, avoiding
excessive pressure increase. Limited pressure changes avoid reaching safety valve opening pressure and the con-
sequent uid drainage.
The following symbols are used in this manual:
b
CAUTION! =
Identies actions that require caution and
adequate preparation.
a
STOP! =
Identies actions that you MUST NOT do.
This manual, Code
- Rev. comprises pages.
General information
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . 2
1 General Safety Information . . . . . . . . . . . . . . . . . . . . . 2
2 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 Description of the appliance . . . . . . . . . . . . . . . . . . . . 3
4 Identication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5 System layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
6 Technical specications . . . . . . . . . . . . . . . . . . . . . . . 4
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
7 Unpacking the product . . . . . . . . . . . . . . . . . . . . . . . . 6
8 Assembly of the insulation and the lining (models
750 - 1000). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
9 Place of installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
10 Installation in older systems and systems requiring
modernisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
11 Water quality requirements . . . . . . . . . . . . . . . . . . . . . 6
12 Water connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
END USER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
13 Recycling and disposal. . . . . . . . . . . . . . . . . . . . . . . . 8
14 Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
15 Temporary shutdown. . . . . . . . . . . . . . . . . . . . . . . . . . 8
16 Preparing for extended periods of disuse . . . . . . . . . 8
17 External maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 8
GENERAL INFORMATION
3
2 PRECAUTIONS
The operation of any appliance that uses electrical power de­mands that a number of fundamental safety precautions be re­spected. In particular:
a
Never attempt to install the system without using suitable personal protection equipment and without following all applicable occupational safety standards.
a
Do not touch the product when barefoot or wet if it has any electrical accessories installed in it.
a
Never clean or service the storage cylinder without rst
turning the mains power switch OFF to disconnect all
electrical accessories (if tted) from the mains electricity
supply.
a
Never pull, disconnect, or twist any electrical cables com­ing from the appliance even if it is disconnected from the mains electricity supply.
a
Do not expose the storage cylinder to the elements. It is not designed for use outdoors.
a
If solar plant pressure decreases, it is forbidden to top up with only water as there is a danger of freezing and over­heating.
a
Do not use connections or safety devices or ttings (ex­pansion vessels, pipes, insulation) that are not specically
designed and tested for use in solar water heating sys­tems.
a
Do not allow children or inrm persons to operate the sys­tem unsupervised.
a
Do not dispose of packaging material into the environ­ment, or leave it within the reach of children, since it can become a potential hazard. Dispose of packaging materi­al in compliance with applicable legislation.
3 DESCRIPTION OF THE APPLIANCE
B
IDRA DS
double-coil solar heaters, available in six differ­ent models, can be integrated in solar systems for the produc­tion of domestic hot water.
B
IDRA DS
solar heaters can be equipped with a solar reg­ulator and can be easily used in solar systems where B boil­ers or heating groups serve as an integration.
The most important technical features of these solar storage cyl­inders are:
- the accurate study of tank and coil geometry
- internal glazing, bacteriologically inert, to ensure the max­imum hygiene of treated water, reduce limescale deposits and make cleaning operations easier
- insulation made of expanded polyurethane free from CFC
(chlorouorocarbons)
- a ange is provided for easy cleaning and maintenance of the anti-corrosion magnesium anode.
4 IDENTIFICATION
The B
IDRA DS
solar heaters can be identied by:
Data plate
This lists the technical specications and performance of the
product.
BALLON SOLAIRE
Modele Model
Fabrication
Code
Année
bar
W
l
W
kW
l/1'
BOLLITORE SOLARE
Modello
Matricola
Codice
Anno
m
2
m
2
kW
m
2
T067764IFE
SOLARBOILER
Serial number
Code
Year
Dispersioni secondo EN 12897 Déperditions selon EN 12897 Heat loss according to EN 12897
V-Hz
Alimentazione elettrica Alimentat. élect. Power supply
Matricola Fabrication Serial number
Modello Modele Model
Potenza elettrica assorbita Puissance élect. absorbée Electrical consumption
Capacità del bollitore Capacité ballon Storage cylinder capacity
Press. esercizio max. Pression service max. Maximum working pressure of storage cylinder
Superficie serpentino inferiore Surface serpentin inférieur Bottom coil heat exchange surface area
Superficie serp. inf. Surface serp. inférieur Bottom coil heat exch. surf. area
Superficie serpentino superiore Surface serpentin supérieur Top coil heat exchange surface area
Massima potenza assorbita sup. [T° Primario 80°C] Puissance absorbée serpentin sup. [T° Primaire 80°C] Power absorbed by top coil [T° primary 80°C]
Max pot. assorb. sup. Puiss. absor. serp. sup. Power abs. by top coil
Collegamento di terra obbligatorio - Raccordement a la terre obligatoire
Obligatory ground connection
Beretta Caldaie Via Risorgimento, 13 23900 Lecco (LC)
Beretta Caldaie Via Risorgimento, 13 23900 Lecco (LC)
Produzione acqua calda sanitaria - serp. sup. [∆T 35°C] Production eau chaude sanitaire - serp. sup. [∆T 35°C]
Domestic hot water production – top coil [∆T 35°C]
Serial number plate
This species the serial number and model.
b
If these plates or any other means of clearly identifying the product are defaced, removed or lost, proper in-
stallation and servicing may be rendered difcult.
5 SYSTEM LAYOUT
1
P
M
7
6
5
2
4
3
UAC
EAF
SB
1
Storage cylinder
2
Top coil
3
Preset for lifting han­dles (accessory) and/ or device grounding point
4
Bottom coil
5
Flange for heater inspection
6
Insulation
7
Cover
P
Socket
M
Guide
UAC
Domestic hot water
outlet
EAF
Domestic cold water
inlet
SB
Storage cylinder drain
Loading...