Bently Nevada vb6 Portable Data sheet

vb6 Portable Vibration Data Collector
Datasheet
Bently Nevada Machinery Condition Monitoring

Description

The vb6 Portable Vibration Data Collector instrument is a portable four channel, high resolution vibration data collector. It is ergonomically designed and lightweight for all day comfort. You can use this device for on-route as well as off-route data collection.
The vb6 Portable Vibration Data Collector samples all four channels simultaneously to provide recordings with up to 12,800 lines of resolution and up to 40 kHz Fmax. Our patented adaptive settling algorithm and 6Pack recording system offer quick, one-step data recording.
The data collector has plenty of storage and long battery life, and is backed by a five year warranty.
The vb6 Portable Vibration Data Collector is one of Bently Nevada hardware monitoring assets that work with System 1 Evolution software.
111M7155 Rev. E
The vb6 Portable Vibration Data Collector offers the following features:
l Four channel simultaneous recordings l 12,800 lines FFTresolution l Supports triaxial sensors l Supports 40 kHz Fmax l 1 GB memory l ≥ 95 dB dynamic range l Supports voltage-output sensors l Spectrum and waveform recordings l Demodulation for early detection of rotating machinery
problems such as bearing faults
l Unique 6Pack recording system
vb6 Portable Vibration Data Collector Datasheet 111M7155 Rev. E
l User-defined recordings for temperature,
pressure, mass flow, force and power l Cable test mode l Option to add flex features such as
balancing and Remote Comms l Upgradable Proflash system and free
firmware updates for 5 years l Five-year warranty on the instrument
hardware
2/7
vb6 Portable Vibration Data Collector Datasheet 111M7155 Rev. E
Parameter Indication

Specifications

Sensors
Sensor input
Compatible sensor types
AC coupled range
DC coupled ranges
Connectors
Analog to digital conversion
Sensor excitation current
Sensor detection
Tachometer Sensor (Optional)
Sensor type
Laser sensor range
Tachometer Input
Supported sensor types
Power supply to sensor
TTL pulse rating
Keyphasor thresholds
Speed range
Accuracy ± 0.1 %
Four channels Simultaneous sampling
Accelerometer, velocity, displacement, current, 4 to 20 mA, voltage output
16 V peak-peak Allows for ± 8 V sensor output swing (± 80 g)
0 V to 20 V, -10 V to 10 V, -20 V to 0 V and readings from voltage output sensors
1 x BNC (CH1) 1 x LEMO (CH2 / CH3 / CH4)
Safety feature:Break-free inline connector
24-bit ADC
0 mA or 2.2 mA (configurable), 24 V maximum
2.2 mA required power for IEPE/ICP type accelerometer
Warns if short circuit or not connected
Laser sensor with reflective tape Sensor triggers on beam reflection
10 cm to 2 m nominal Range depends on size of reflective tape
Laser Tach, Contact, TTL Pulse, Keyphasor Instrument has optically isolated input
5 V, 50 mA
3.5 V (4 mA) min 28 V (5 mA) max Off-state 0.8 V
7.7 ± 0.5 V 13.2 ± 0.8 V 18.5 ± 1 V
Nominally 8 V, 13 V, 18 V 10 RPM to 300,000 RPM (0.2 Hz to 5
kHz)
Pulse width at least 0.1 ms
> 1000 g (10,000 m/s2) > 1000 in/sec
Maximum levels (peak)
Dynamic signal range
Harmonic distortion
Units
Magnitude & cursors
Base accuracy
High frequency attenuation
AC coupling attenuation
Attenuation due to Integration (normal mode)
Attenuation due to Integration (low frequency mode)
(25,000 mm/s) > 20 in (500 mm) > 10,000 Amps
Effective limit is sensor sensitivity and output voltage
> 95 dB
typical at 400 line resolution Less than -70 dB typical
Other distortions and noise are lower g or m/s2 or adB in/s or mm/s or vdB
mil or mm or µm amps, user-defined
0-peak, peak-peak or RMS Auto-scale by 1000x when required
US and SI options for adB and vdB Overall RMS value Waveform True pk-
pk Dual cursors Harmonics
Digital readouts on chart ± 1% of readings approximately 0.1 dB
For AC signal: % of reading For DC signal: % of full scale
≤ 0.1 dB 100 Hz to 10 kHz ≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
≤ 0.1 dB 10 Hz to <100 Hz ≤ 3 dB 1 Hz to <10 Hz
≤ 0.1 dB 10 Hz to <100 Hz ≤ 1.5 dB 1 Hz to <10 Hz
Values apply to single integration. (Acceleration to velocity)
Double the values for double integration (Acceleration to displacement)
≤ 0.1 dB 1 Hz to <100 Hz ≤ 1.5 dB 0.2 Hz to <1 Hz
Applies when coupling = DC and Fmax ≤ 100 Hz
Waveform Display
Number of samples
Time scale
1024, 2048, 4096, 8192, 16,384, 32,768
10 ms to 512 seconds or orders based
3/7
vb6 Portable Vibration Data Collector Datasheet 111M7155 Rev. E
from 1 to 999 revs
Logging and Analysis
Output formats
Data storage
Data storage structur e
Max folder size
Instrument screen, transfer to Ascent, XML
Dual 1 GB non-volatile flash memories Database mirror copy on second flash memory
Folders/machines/points/locations/route s
No limits are applied 50 character names
10,000 measurement locations
Spectrum Display
25, 50, 100, 125, 150, 200, 300, 400, 500, 600, 800, 1000, 1200, 1600, 2000,
Fmax ranges
Fmin possible range
Resolution
Frequency scale
Amplitude scale
Window shapes
Overlap
Number of averages
Averaging types
Demodulation bandwidths
6Pack
2500, 3000, 4000, 5000, 6000, 8000, 10,000, 15,000, 20,000, 30,000, 40,000 Hz Or equivalent CPM values Or orders-based from 1X to 999X
0 to Fmax Instrument zeroes all spectral lines below Fmin.
400, 800, 1,600, 3,200, 6,400, 12,800 lines 6400 lines max. for dual channel measurements 3200 lines max. for four channel measurements
Hz, CPM, Orders Linear scale with zooming
Acceleration, velocity, displacement, current or user-defined Linear or log scales, auto or manual scaling
Hanning Rectangular
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) % Depends on Fmax and number of lines
1, 2, 4, 8, 16, 32, 64, 128 Increases sampling time proportionally
Linear, exponential, peak hold
23 bandwidth options From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
Up to 40 kHz & 3200 lines (1 channel) Up to 20 kHz & 1600 lines (3 channel) Spectrum and waveform for low­frequency, high-frequency and demodulation
Up to 6 kHz Fmax Orders-based
Order tracking
Order tracking
- Distortion
Tachometer required Mounted on high-speed shaft
Less than -65 dB
Within 50% to 200% speed variation during recording
Display and Communication
Display
Resolution & size 480 x 320 (HVGA), 5.7” Readable in
Supported Languages
Communication with PC
USB host port
Graphic Grayscale LCD LED Backlight
direct sunlight English, Chinese, French, German,
Japanese, Portuguese, Russian and Spanish Firmware released in English, translations will follow
USB or Ethernet
Use PROFLASH to upgrade instrument firmware
USB 2.0, supplying 5V, 250mA Save folders to USB flash drive
Battery and Charger
Battery type Custom Lithium Ion pack, 7.4 V, 5 Ah Operating
time
Charger type
Charge rate
10 hours Backlight on — 60 second timeout
Internal charging, automatic control External power pack 12 V DC, 3 A output
3 A nominal 3 hours for complete charge
Mechanical
Size 9.9" W x 5.8" l x 2.4" H (252 x148 x60 mm) Weight 2.7 lb (1.2 kg) Including battery and strap
Environmental Limits
Operating temperature
Storage temperature and humidity
Ruggedness
14 °F to 122 °F (-10 to 50 °C)
-4 °F to 140 °F (-20 to 60 °C), 95% RH
Up to 95 F (35 C), 85% RH if storage exceeds 1 month
IP65 sealed 4’ (1.2 m) drop onto concrete Procedure: 26 drops following MIL-STD-810F-516.5-IV
4/7
vb6 Portable Vibration Data Collector Datasheet 111M7155 Rev. E
Hazardous Area Approvals

Compliance and Certifications

FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
l This device may not cause harmful
interference.
l This device must accept any
interference received, including interference that may cause undesired operation.
EMC
EN 61326-1: 2012
EN 61326-2-3: 2012
EMC Directive 2014/30/EU
Electrical Safety
For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from
Bently.com.
CSA/NRTL/C (Approval Option 01)
Class I, Division 2, Groups A, B, C, D
EN 62133: 2002
LV Directive 2014/35/EU
RoHS
RoHS Directive 2011/65/EU
5/7
vb6 Portable Vibration Data Collector Datasheet 111M7155 Rev. E
Part Number Description Qty

Ordering Information

For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from
Bently.com.
VB6-AA
NKST0553
108M4044 AC power adapter 1 DCCA0041 DC car adapter 1
108M3536
MVBX0250 Instrument Reference guide 1
vbx neck strap with Sensor Keeper
SCOUT100 Series and vbSeries Quick Start Guide
1
1
A: Agency Approval 01 CSA
Basic Kit
We offer the vb6 Portable Vibration Data Collector instrument in a basic kit with the option to purchase the System 1 Evolution software and license separately.
* Kit items below with multiple part numbers listed have limited regional availability due to certification requirements.
Part Number Description Qty
vb6 Portable Vibration Data
ACCL0547 or 200350 *
ACCL0561 or 200350 *
138M7748 Transducer cable, 4 ft. straight 4 MAGF0104 Accelerometer magnetic base 4 CABB0560 BNC to BNC cable, 1m 1 CABU0213 USB data transfer cable 1 CBTB0278 Triple BNC cable 1
110M8172-012
PLUS0230
PLSA0241
PLAU0228
PLHK0245
PLEU0229 Category C Power plug, Europe 1 CBVB0552 vbx instrument carry bag 1
Collector four channel portable data collector
Straight accelerometers 3
Right-angle accelerometer or straight accelerometer
LEMO-BNC TTL Tach/Keyphasor cable
Category A power plug, USA / Canada
Category D power plug, South Africa / India
Category M power plug, Australia / New Zealand / China
Category G power plug, Hong Kong / UK
1
1
1
1
1
1
1

Additional Accessories

Software
Part Number Description
108M4051 ASCENT Level 1 108M4052 ASCENT Level 2 3071/01 System 1 Evolution
Hardware
Part Number Description
100M5828 The vbSeries hard case DTC70262 The vbSeries dust cover
BATT0575
KTTC0331
108M4069
CBL50216
113M5529-01
Replacement battery pack, Li-Ion 7.4 V 5 Ah
Triaxial sensor kit 100 mV/g +/- 20% Magnet 6 ft coiled cable, with breakaway connector Zone 2 and Class 1, Div 2 rating
Laser Tach powered by vb6 Portable Vibration Data Collector
Five-meter laser Tach cable for 108M4069
Reflective tape One roll, 60 cm (23.7 in)
6/7
vb6 Portable Vibration Data Collector Datasheet 111M7155 Rev. E
Copyright 2020 Baker Hughes Company. All rights reserved.
Bently Nevada, vb Series, System 1, Keyphasor and Orbit Logo are registered trademarks of Bently Nevada, a Baker Hughes Business, in the United States and other countries. The Baker Hughes logo is a trademark of Baker Hughes Company. All other product and company names are trademarks of their respective holders. Use of the trademarks does not imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not make any representation as to the accuracy or completeness of the information and makes no warranties of any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect, consequential or special damages, claims for lost profits, or third party claims arising from the use of the information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of BakerHughes and its affiliates; and is subject to change without prior notice. It is being supplied as a service to our customers and may not be altered or its content repackaged without the express written consent of Baker Hughes. This product or associated products may be covered by one or more patents. See Bently.com/legal.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 1.775.782.3611 or 1.800.227.5514 (US only)
Bently.com
7/7
Loading...