vb6 Portable Vibration Data Collector
Datasheet
Bently Nevada Machinery Condition Monitoring
Description
The vb6 Portable Vibration Data Collector instrument is a
portable four channel, high resolution vibration data
collector. It is ergonomically designed and lightweight for all
day comfort. You can use this device for on-route as well as
off-route data collection.
The vb6 Portable Vibration Data Collector samples all four
channels simultaneously to provide recordings with up to
12,800 lines of resolution and up to 40 kHz Fmax. Our patented
adaptive settling algorithm and 6Pack recording system offer
quick, one-step data recording.
The data collector has plenty of storage and long battery life,
and is backed by a five year warranty.
The vb6 Portable Vibration Data Collector is one of Bently
Nevada hardware monitoring assets that work with System 1
Evolution software.
111M7155 Rev. E
The vb6 Portable Vibration Data Collector offers the
following features:
l Four channel simultaneous recordings
l 12,800 lines FFTresolution
l Supports triaxial sensors
l Supports 40 kHz Fmax
l 1 GB memory
l ≥ 95 dB dynamic range
l Supports voltage-output sensors
l Spectrum and waveform recordings
l Demodulation for early detection of rotating machinery
problems such as bearing faults
l Unique 6Pack recording system

vb6 Portable Vibration Data Collector
Datasheet 111M7155 Rev. E
l User-defined recordings for temperature,
pressure, mass flow, force and power
l Cable test mode
l Option to add flex features such as
balancing and Remote Comms
l Upgradable Proflash system and free
firmware updates for 5 years
l Five-year warranty on the instrument
hardware
2/7

vb6 Portable Vibration Data Collector
Datasheet 111M7155 Rev. E
Parameter Indication
Specifications
Sensors
Sensor input
Compatible
sensor types
AC coupled
range
DC coupled
ranges
Connectors
Analog to
digital
conversion
Sensor
excitation
current
Sensor
detection
Tachometer Sensor (Optional)
Sensor type
Laser sensor
range
Tachometer Input
Supported
sensor types
Power supply
to sensor
TTL pulse
rating
Keyphasor
thresholds
Speed range
Accuracy ± 0.1 %
Four channels Simultaneous
sampling
Accelerometer, velocity, displacement,
current, 4 to 20 mA, voltage output
16 V peak-peak Allows for ± 8 V
sensor output swing (± 80 g)
0 V to 20 V, -10 V to 10 V, -20 V to 0 V
and readings from voltage output
sensors
1 x BNC (CH1) 1 x LEMO (CH2 / CH3 /
CH4)
Safety feature:Break-free inline
connector
24-bit ADC
0 mA or 2.2 mA (configurable), 24 V
maximum
2.2 mA required power for IEPE/ICP
type accelerometer
Warns if short circuit or not connected
Laser sensor with reflective tape
Sensor triggers on beam reflection
10 cm to 2 m nominal Range
depends on size of reflective tape
Laser Tach, Contact, TTL Pulse,
Keyphasor Instrument has optically
isolated input
5 V, 50 mA
3.5 V (4 mA) min 28 V (5 mA) max
Off-state 0.8 V
7.7 ± 0.5 V 13.2 ± 0.8 V 18.5 ± 1 V
Nominally 8 V, 13 V, 18 V
10 RPM to 300,000 RPM (0.2 Hz to 5
kHz)
Pulse width at least 0.1 ms
> 1000 g (10,000 m/s2) > 1000 in/sec
Maximum
levels
(peak)
Dynamic
signal
range
Harmonic
distortion
Units
Magnitude
& cursors
Base
accuracy
High
frequency
attenuation
AC
coupling
attenuation
Attenuation
due to
Integration
(normal
mode)
Attenuation
due to
Integration
(low
frequency
mode)
(25,000 mm/s) > 20 in (500 mm) >
10,000 Amps
Effective limit is sensor sensitivity and
output voltage
> 95 dB
typical at 400 line resolution
Less than -70 dB typical
Other distortions and noise are lower
g or m/s2 or adB in/s or mm/s or vdB
mil or mm or µm amps, user-defined
0-peak, peak-peak or RMS Auto-scale
by 1000x when required
US and SI options for adB and vdB
Overall RMS value Waveform True pk-
pk Dual cursors Harmonics
Digital readouts on chart
± 1% of readings approximately 0.1 dB
For AC signal: % of reading For DC
signal: % of full scale
≤ 0.1 dB 100 Hz to 10 kHz ≤ 3 dB >10 kHz to
40 kHz
Attenuation tolerances are in addition
to base accuracy.
≤ 0.1 dB 10 Hz to <100 Hz ≤ 3 dB 1 Hz to <10
Hz
≤ 0.1 dB 10 Hz to <100 Hz ≤ 1.5 dB 1 Hz to
<10 Hz
Values apply to single integration.
(Acceleration to velocity)
Double the values for double
integration (Acceleration to
displacement)
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
Applies when coupling = DC and Fmax
≤ 100 Hz
Waveform Display
Number of
samples
Time scale
1024, 2048, 4096, 8192, 16,384, 32,768
10 ms to 512 seconds or orders based
3/7