Bently Nevada vb5 Portable Data sheet

vb5 Portable Data Collector
Datasheet
Bently Nevada Machinery Condition Monitoring

Description

The vb5 Portable Data Collector instrument is a portable single channel vibration data collector. It is ergonomically designed and lightweight for all day comfort. You can use this device for on-route as well as off-route data collection.
The vb5 Portable Data Collector provides recordings with up to 6,400 lines of resolution and up to 40 kHz F patented adaptive settling algorithm and 6Pack recording system offer quick, one-step data recording.
The data collector has plenty of storage and long battery life, and is backed by a five year warranty.
The vb5 Portable Data Collector is one of Bently Nevada hardware monitoring assets that work with System 1 Evolution software.
The vb5 Portable Data Collector offers the following features:
111M6572 Rev. F
max
l Single channel recordings l 6,400lines FFTresolution l Supports 40 kHz F
l 1 GB memory l ≥ 95 dB dynamic range l Spectrum and waveform recordings l Demodulation for early detection of rotating machinery
max
problems such as bearing faults
l Unique 6Pack recording system l Cable test mode l Option to add flex features such as balancing and
Remote Comms
l Upgradable Proflash system and free firmware updates
for 5 years
l Five-year warranty on the instrument hardware
vb5 Portable Data Collector Datasheet 111M6572 Rev. F

Specifications

Sensors
Sensor Input One channel Compatible
Sensor Types AC Coupled
Range
Connectors
Analog to Digital Conversion
Sensor Excitation Current
Sensor Detection
Tachometer Sensor (Optional)
Sensor Type
Laser Sensor Range
Tachometer Input
Supported Sensor Types
Power Supply to Sensor
TTL PulseRating
Speed Range
Accuracy ± 0.1 %
Accelerometer
16 V peak-peak Allows for ± 8 V sensor output swing (± 80 g)
1 x BNC (CH1)
Safety feature:Break-free inline connector
24-bit ADC
0 mA or 2.2 mA (configurable), 24 V maximum
2.2 mA required power for IEPE/ICP type accelerometer
Warns if short circuit or not connected
Laser sensor with reflective tape Sensor triggers on beam reflection
10 cm to 2 m nominal Range depends on size of reflective tape
Laser Tach, Contact, TTL Pulse Instrument has optically isolated input
5 V, 50 mA
3.5 V (4 mA) min 28 V (5 mA) max Off-state 0.8 V
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms
Parameter Indication
> 1000 g (10,000 m/s2) > 1000
Maximum Levels (peak)
Dynamic Signal Range
Harmonic Distortion
Units
Magnitude and Cursors
Base Accuracy
High Frequency Attenuation
AC Coupling Attenuation
Attenuation Due to Integration
in/sec (25,000 mm/s) > 20 in (500 mm)
Effective limit is sensor sensitivity and output voltage
> 95 dB
typical at 400 line resolution Less than -70 dB typical
Other distortions and noise are lower
g or m/s2 or adB in/s or mm/s or vdB mil or mm or µm
0-peak, peak-peak or RMS Auto­scale by 1000x when required
US and SI options for amps and volts
Overall RMS value Waveform True pk-pk Dual cursors Harmonics
Digital readouts on chart ± 1% of readings approximately
0.1 dB
% of reading ≤ 0.1 dB 100 Hz to 10 kHz ≤ 3 dB >10
kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
≤ 0.1 dB 10 Hz to <100 Hz ≤ 3 dB 1 Hz to <10 Hz
≤ 0.1 dB 1 Hz to <100 Hz ≤ 1.5 dB 0.2 Hz to <1 Hz
Values apply to single integration. (Acceleration to velocity)
Double the values for double integration (Acceleration to displacement)
2/6
vb5 Portable Data Collector Datasheet 111M6572 Rev. F
Spectrum Display
25, 50, 100, 125, 150, 200, 300, 400, 500, 600, 800, 1000, 1200, 1600,
F
Ranges
max
F
Possible
min
Range Resolution 400, 800, 1600, 3200, 6400 lines
Frequency Scale
Amplitude Scale
Window Shapes Hanning Rectangular
Overlap
Number of Averages
Averaging Types Linear,exponential, peak hold
Demodulation Bandwidths
6Pack
2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000, 15,000, 20,000, 30,000, 40,000 HzOr equivalent CPM values Or orders­based from 1X to 999X
0 to F spectral lines below F
Hz, CPM, Orders Linear scale with zooming
Acceleration, velocity, displacement Linear or log scales, auto or manual scaling
(0, 12.5, 25, 37.5, 50, 62.5, 75,
87.5) %
Depends on F lines
1, 2, 4, 8, 16, 32, 64, 128 Increases sampling time proportionally
23 bandwidth options From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
Up to 40 kHz & 3200 lines (1 channel) Spectrum and waveform for low-frequency, high-frequency and demodulation
Instrument zeroes all
max
and number of
max
min
Waveform Display
Number of Samples
TimeScale
1024, 2048, 4096, 8192, 16,384
10 ms to 256 seconds or orders based from 1 to 999 revs
Logging and Analysis
Output Formats
Data Storage
Data Storage Structure
Instrument screen, transferto System1 Evolution, XML
Dual 1 GB non-volatile flash memories Database mirror copy on second flash memory
Folders/machines/ points/locations/routes
No limits are applied 50 characternames
Max Folder Size 10,000 measurement locations
Display and Communication
Display
Resolution and Size
Supported Languages
Communication with PC
USB Host Port
Graphic Grayscale LCD LED Backlight
480 x 320 (HVGA), 5.5” (140 mm)
Readable in direct sunlight English, Chinese, French, German,
Japanese, Portuguese, Russian and Spanish
USB or Ethernet
Use PROFLASH to upgrade instrument firmware
USB 2.0, supplying 5V, 250mA Save folders to USB flash drive
Battery and Charger
Battery Type Custom Lithium Ion pack, 7.4 V, 5 Ah Operating
Time
Charger Type
Charge Rate
10 hours Backlight on — 60 second timeout
Internal charging, automatic control External power pack 12 V DC, 3 A output
3 A nominal 3 hours for complete charge
Mechanical
Size
Weight
9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
2.7 lb (1.2 kg) Including battery and strap
Environmental Limits
Operating Temperature
Storage Temperature and Humidity
Ruggedness
14 °F to 122 °F (-10 to 50 °C)
-4 °F to 140 °F (-20 to 60 °C), 95% RH
Up to 95 F (35 C), 85% RH if storage exceeds 1 month
IP65 sealed 4’ (1.2 m) drop onto concrete Procedure: 26 drops following MIL-STD-810F-516.5-IV
3/6
vb5 Portable Data Collector Datasheet 111M6572 Rev. F
Hazardous Area Approvals

Compliance and Certifications

FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
l This device may not cause harmful
interference.
l This device must accept any
interference received, including interference that may cause undesired operation.
EMC
EN 61326-1: 2012
EN 61326-2-3: 2012
EMC Directive 2014/30/EU
Electrical Safety
For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from
Bently.com.
CSA/NRTL/C (Approval Option 01)
Class I, Division 2, Groups A, B, C, D
EN 62133: 2002
LV Directive 2014/35/EU
RoHS
RoHS Directive 2011/65/EU
4/6
vb5 Portable Data Collector Datasheet 111M6572 Rev. F

Ordering Information

For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from
Bently.com.
VB5-AA
A: Agency Approval 01 CSA
Basic Kit
We offer the vb5 Portable Data Collector instrument in a basic kit with the option to purchase the System 1 Evolution software and license separately.
* Kit items with multiple part numbers listed have limited regional availability due to certification requirements.
Part
Number
vb5 Portable Data Collector single-channel portable data collector
ACCL0547 or 200350*Straight accelerometer 1
138M7748
MAGF0104
CABB0560 BNC to BNC cable,1 m 1 CABU0213 USB data transfer cable 1 110M8172-
012
PLUS0230
PLSA0241
PLAU0228
PLHK0245
PLEU0229
Transducer cable, 4 ft. straight
Accelerometer magnetic base
LEMO-BNC TTL Tach/Keyphasor cable
Category A power plug, USA / Canada
Category D power plug, South Africa / India
Category M power plug, Australia / New Zealand / China
Category G power plug, Hong Kong / UK
Category C Power plug, Europe
Description Quantity
1
1
1
1
1
1
1
1
1
Part
Number
CBVB0552 vbx instrument carry bag 1
NKST0553
108M4044 AC power adapter 1 DCCA0041 DC car adapter 1
108M3536
MVBX0250 Instrument Reference guide 1
vbx neck strap with Sensor Keeper
SCOUT100 Series and vbSeries Quick Start Guide
Description Quantity

Additional Accessories

Software
Part Number Description
3071/01 System1 Evolution
Hardware
Part
Number
100M5828 The vbSeries hard case DTC70262 The vbSeries dust cover
BATT0575
108M4069
CBL50216
113M5529­01
Replacement battery pack, Li-Ion 7.4 V 5 Ah
Laser Tach powered by vb5 Portable Data Collector
Five-meter laserTach cable for 108M4069
Reflective tape One roll, 60 cm (23.7 in)
Description
1
1
5/6
vb5 Portable Data Collector Datasheet 111M6572 Rev. F
Copyright 2020 Baker Hughes Company. All rights reserved.
Bently Nevada, vb Series, System 1, Keyphasor and Orbit Logo areregistered trademarks of Bently Nevada, a Baker Hughes Business, in the United States and other countries. The Baker Hughes logo is a trademark of Baker Hughes Company. All other product and company names are trademarks of their respective holders. Use of the trademarks does not imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not make any representation as to the accuracy or completeness of the information and makes no warranties of any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect, consequential or special damages, claims for lost profits, or third party claims arising from the use of the information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of BakerHughes and its affiliates; and is subject to change without prior notice. It is being supplied as a service to our customers and may not be altered or its content repackaged without the express written consent of Baker Hughes. This product or associated products may be covered by one or more patents. See Bently.com/legal.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 1.775.782.3611 or 1.800.227.5514 (US only)
Bently.com
6/6
Loading...