BenQ W6000 User Manual

W6000
Software/RS-232 Programming Guide
Revision 1
BenQ W6000 RS-232 Programming Guide
(Revision 1)
1 of 6
BenQ W6000 RS-232 Programming Guide
(Revision 1)
Communication Settings
The default settings for the RS-232 COM port are as follows:
Baud Rate: 115,200 Parity: None Data bits: 8 Stop bits: 1 Flow Control: None
2 of 6
RS-232 Connector Information
The pin-out for the RS-232 control port is as follows:
Pin Description
1 No Connection 2 Receive Data 3 Transmit Data 4 No Connection 5 Ground 6 No Connection 7 RTS (Not needed if Flow Control set to None) 8 CTS (Not needed if Flow Control set to None) 9 No Connection