Bendix® LP-2™ & LP-3™ Low Pressure Indicators
COVER
SPRING
SD-06-1600
COVER
SPRING
DIAPHRAGM
BODY
FIGURE 1 - BENDIX® LP-2™ LOW PRESSURE INDICATOR FIGURE 2 - BENDIX® LP-3™ LOW PRESSURE INDICATOR
DESCRIPTION
The low pressure indicator is a safety device designed
to give an automatic warning to the driver whenever air
pressure in the air brake system is below the safe minimum
for normal vehicle operation. It is usually used to operate
an electrical buzzer or warning light, or both, which are
audible or visible to the driver.
Two styles of low pressure indicators are currently
manufactured.
The Bendix® LP-2™ low pressure indicator, which is the
older style, consists of a die cast body with a spring loaded
diaphragm clamped between the body and the Bakelite
cover.
CONTACT
POINTS
employs a spring loaded o-ring diaphragm and piston. The
LP-3™ indicator is available with either one terminal or two.
The single terminal unit utilizes a metallic gasket between
body and case to ground the lower contact strip. The two
terminal unit utilizes a phenolic insulating gasket to isolate
both terminals from the vehicle frame.
The electrical contacts provided in both the LP-2™ and
LP-3™ indicators remain closed by spring force until the
air brake system pressure below the diaphragm is above
the setting (force) of the low pressure indicator spring. The
setting of the indicator and piece number is marked on a
label on the valve body. If a label is not present, then the
vehicle manual should be consulted for the proper setting.
The nominal setting of the indicator is 60 psi; however,
CONTACT
POINTS
PISTON
BODY
O-RING
DIAPHRAGM
pressure settings may vary depending upon the vehicle.
The Bendix® LP-3™ low pressure indicator is the newer
style. It consists of a die cast body, nylon cover and
1
OPERATION
To describe the operation, we shall assume that the low
pressure indicator is set for 60 psi. When air pressure at the
supply port and under the diaphragm is above 60 psi, the
electrical contacts remain open because the force exerted
by air pressure underneath the diaphragm overcomes the
force exerted by the spring above the diaphragm.
When air pressure below the diaphragm drops below 60
psi, the spring exerts a force which is greater than the
force exerted by the air pressure below the diaphragm.
This causes the diaphragm (and the piston in the Bendix
LP-3™ indicator) to move and allow the electrical contacts
to close. This completes or closes the electrical circuit to
the warning device, warning the driver of low air pressure
in the system.
®
PREVENTIVE MAINTENANCE
Important: Review the Bendix Warranty Policy before
performing any intrusive maintenance procedures. A
warranty may be voided if intrusive maintenance is
performed during the warranty period.
No two vehicles operate under identical conditions; as
a result, maintenance intervals may vary. Experience is
a valuable guide in determining the best maintenance
interval for air brake system components. At a minimum,
the low pressure indicator should be inspected every 6
months or 1500 operating hours, whichever comes fi rst,
for proper operation. Should the low pressure indicator not
meet the elements of the operational tests noted in this
document, further investigation and service of the valve
may be required.
TESTING FOR SERVICEABILITY
OPERATING TEST
1. If possible, determine the setting of the low pressure
indicator by referring to the label on the valve or the
vehicle manual.
2. Operation of the low pressure indicator may be checked
with ignition switch “on” by reducing the system
pressure and observing that low pressure warning
occurs when system pressure drops below the setting
of the low pressure indicator. The contacts will be
closed when the warning device operates. If the setting
of the indicator is unknown, the contacts should close
between approximately 70 psi and 50 psi.
LEAKAGE TEST
1. With air pressure present at the supply port, coat the
indicator with a soap solution. No leakage is permitted.
REMOVING
1. Block the wheels or secure the vehicle with other than
service brakes.
2. The ignition switch should be in the “off” position.
3. Drain the air from the system.
4. Disconnect the electrical connections at the low
pressure indicator.
5. Disconnect the air line and mounting bolts or unscrew
the Indicator from the fi tting and remove.
INSTALLING
1. Install in a convenient location for servicing.
2. Connect to a reservoir pressure line at a high point in
the system for adequate drainage.
3. If installing a Bendix® LP-2™ indicator, use a supply line
of 1/4” O.D. minimum.
4. Connect the Indicator terminals in series with the
ignition switch and the warning device.
DISASSEMBLY
NOTE: It is generally recommended that the low pressure
indicator, if faulty, be replaced with a new unit;
however, service parts are available; and if repairs
are necessary, the following will apply:
LP-2™ indicator. Unscrew the cover retainer from the
body. Remove cover and remove spring and diaphragm
assembly.
LP-3™ indicator. Remove cover screw and lockwashers.
Remove the cover, contact disc, spring, and shim(s). (Note:
shims may or may not be present.) Remove contact plate,
gasket, piston, and o-ring diaphragm.
CLEANING AND INSPECTION
1. Clean all metal parts in mineral spirits and dry them
completely.
2. Inspect all parts for excessive wear or deterioration.
Check the valve spring for cracks or corrosion.
3. Inspect contact points. If contact points are not severely
pitted, they can be dressed with a fi ne fi le.
Replace all parts that were discarded and any parts not
found to be serviceable during inspection, using only
genuine Bendix replacement parts.
ASSEMBLY
NOTE: When using pipe thread sealant during assembly
and installation, take particular care to prevent the
sealant from entering the valve itself. Apply the
sealant beginning with the second thread back
from the end.
BENDIX® LP-2™ INDICATOR
1. Place and position the diaphragm assembly in the
body. Position the spring so that it rests on the upper
diaphragm follower.
2. Place the cover over the diaphragm and screw the
cover retainer to the body and tighten securely . (T orque
to 110-130 inch pounds.)
2