Behringer DI4000 User Manual

User Manual
ULTRA-DI PRO DI4000
Professional 4-Channel Active DI-Box
2 ULTRA-DI PRO DI4000 User Manual
Table of Contents
Important Safety Instructions ...................................... 3
Legal Disclaimer ............................................................. 3
Limited warranty ............................................................ 3
1. Introduction ............................................................... 4
1.1 Before you begin ................................................................. 4
1.2 Online registration ............................................................. 4
1.3 Control elements ................................................................ 5
2. Applications ............................................................... 5
2.1 Tapping signal from a (bass) guitar .............................. 5
2.2 Converting the output of a keyboard / DJ-mixer /
headphone plug ......................................................................... 5
2.3 Converting a microphone signal .................................. 6
2.4 Tapping a signal from a power amplieroutput .... 6
3.1 Rack mounting ..................................................................... 6
3.2 Mains connection .............................................................. 6
3.3 Audio connections ............................................................. 6
3 ULTRA-DI PRO DI4000 User Manual
9. Do not defeat the safety purpose of the polarized
TO BIND MUSICGROUP BY ANY EXPRESS OR IMPLIED

Important Safety Instructions

Terminals marked with this symbol carry electrical current of su cient magnitude
to constitute risk of electric shock. Use only high-quality professional speaker cables with ¼" TS or twist-locking plugs pre-installed. Allother installation or modi cation should be performed only by quali edpersonnel.
This symbol, wherever it appears,
alertsyou to the presence of uninsulated
dangerous voltage inside the enclosure-voltage that may be su cient to constitute a risk ofshock.
This symbol, wherever it appears,
alertsyou to important operating and
maintenance instructions in the accompanying literature. Please read the manual.
Caution
To reduce the risk of electric shock, donot
remove the top cover (or the rear section). No user serviceable parts inside. Refer servicing to quali ed personnel.
Caution
To reduce the risk of  re or electric shock,
do not expose this appliance to rain and moisture. The apparatus shall not be exposed to dripping or splashing liquids and no objects  lled with liquids, suchas vases, shall be placed on the apparatus.
Caution
These service instructions are for use
by quali ed service personnel only. Toreduce the risk of electric shock do not perform any servicing other than that contained in the operation instructions. Repairs have to be performed by quali ed servicepersonnel.
or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. Ifthe provided plug does not  t into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Use only attachments/accessories speci ed by themanufacturer.
12. Use only with the cart, stand, tripod, bracket, or table speci ed by the manufacturer, orsold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid
injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to quali ed service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has beendropped.
15. The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.
16. Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
UNDERTAKING OR REPRESENTATION. THIS MANUAL IS COPYRIGHTED. NO PART OF THIS MANUAL MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING AND RECORDING OF ANY KIND, FOR ANY PURPOSE, WITHOUT THE EXPRESS WRITTEN PERMISSION OF MUSICGROUPIPLTD.
ALL RIGHTS RESERVED. © 2013 MUSICGroupIPLtd. Trident Chambers, Wickhams Cay, P.O. Box 146, Road Town, Tortola, British Virgin Islands

LIMITED WARRANTY

For the applicable warranty terms and conditions and additional information regarding MUSIC Group’s Limited Warranty, please see complete details online at www.music-group.com/warranty.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampli ers) that produce heat.

LEGAL DISCLAIMER

TECHNICAL SPECIFICATIONS AND APPEARANCES ARE SUBJECT TO CHANGE WITHOUT NOTICE AND ACCURACY IS NOT GUARANTEED. BEHRINGER, KLARKTEKNIK, MIDAS, BUGERA, AND TURBOSOUND ARE PART OF THE MUSIC GROUP MUSICGROUP.COM. ALL TRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS. MUSICGROUP ACCEPTS NO LIABILITY FOR ANY LOSS WHICH MAY BE SUFFERED BY ANY PERSON WHO RELIES EITHER WHOLLY OR IN PART UPON ANY DESCRIPTION, PHOTOGRAPH OR STATEMENT CONTAINED HEREIN. COLORS AND SPECIFICATIONS MAY VARY FROM ACTUAL PRODUCT. MUSIC GROUP PRODUCTS ARE SOLD THROUGH AUTHORIZED FULLFILLERS AND RESELLERS ONLY. FULLFILLERSAND RESELLERS ARE NOT AGENTS OF MUSICGROUP AND HAVE ABSOLUTELY NO AUTHORITY
4 ULTRA-DI PRO DI4000 User Manual

1. Introduction

Whether you are on the stage or in the studio, you often nd that you need to connect an audio source to your mixing console, but you don’t have the appropriate connectors. For example, only few keyboards feature balanced outputs; guitars should not be connected directly to the console; and placing a microphone in front of an amp is not always an ideal solution, because the mic will pick up unwanted signals from other instruments, too. Low frequency signals (e.g. produced by a bass guitar) are particularly dicult to handle using thesetechniques.
“DI” is short for “Direct Injection”. A Direct Inject box allows you to use a high-impedance, unbalanced source, e.g. the signal between guitar and guitar amp, and feed it directly into an input channel on your console, withouthaving to use a microphone. And that’s far from being all. There are plenty of situations in which you’d like to input unbalanced source signals into your console, andpossibly convert them to balanced signals before. As you can expect, theDI4000 oers you a reliable solution.
The following explanations will give you an introduction to the complex performance-impedance issue: impedance is dened as the dependence of a device’s electrical resistance and phase response on the frequency processed. Thus, impedance is one of the criteria that distinguish good DI boxes from poor ones. Much like in a power amp and its connected speakers, impedancedetermines the performance of the device. With a good power amp, the load impedance will have little inuence on the maximum output power, butit can considerably aect other properties. With a passive DI box, the connected load impedances (ins and outs) alter the bandwidth, frequencyresponse, distortion, etc. of the DI box.
By the way: there are two basic types of DI boxes, passive and active. Bothcan be connected to one of the console’s mic inputs. Passive DI boxes oer the advantage that they are less expensive than active models (less electronics, no power supply), however, their performance depends on the connected impedance. With a passive DI box connected, any impedance change on the console side will also modif y the input impedance. The frequency response will always depend on the impedances connected. Any passive DI box will only perform properly with accurately specied impedances (high on the input side, low at the output), i.e. it will only work in standard situations.
High-quality components and design
The philosophy behind BEHRINGER products guarantees a no-compromise circuit design and employs the best choice of components. The op-amps, type 4580, used in the ULTRA-DI PRO are chosen for their superior signal-to-noise ratio, lowdistortion and linear performance. Additionally, the ULTRA-DI PRO uses high quality resistors and capacitors with ver y tight tolerances, high-grade switches as well as other selected components.
This manual first describes the terminology used, so that you can fully
understand the ULTRA‑DI PRO and its functions. Please read the manual carefully and keep it for future reference.

1.1 Before you begin

Your BEHRINGER ULTRA-DI PRO was carefully packed in the factory and the packaging was designed to protect the unit from rough handling. Nevertheless,werecommend that you carefully examine the packaging and its contents for any signs of physical damage, which may have occurred in transit.
If the unit is damaged, please do not return it to us, but notify your
dealer and the shipping company immediately, otherwise claims for damage or replacement may not be granted. Shipping claims must be made by the consignee.
The BEHRINGER ULTR A-DI PRO ts into one standard 19" rack unit of space. Pleaseallow at least an additional 4" (10 cm) depth for the connectors on the back panel.
Be sure that there is enough space around the unit for cooling and
please do not place the ULTRA ‑DI PRO on high temperature devices such as power amplifiers etc. to avoid overheating.
The mains connection of the ULTRA-DI PRO is made by using the supplied cable. Itmeets all of the international safety certication requirements. Please make sure that all units have a proper ground connection.
Before you connect your ULT RA‑DI PRO to the mains, please make sure
that your local voltage matches the voltage required by the unit!

1.2 Online registration

Active DI boxes such as our ULTRA-DI PRO, however, do not suer from such restrictions, because they use an amplier circuit to buer the input signal. Sincethe ULTRA-DI PRO’s input impedance is ultra-high, the signal remains unaected as it passes through the DI box. Additionally, the ULTRA-DI PRO features balanced impedances on the output side, making the signal less susceptible to hum and noise inter ference. In this way, the signal as source impedance is completely independent of the console used (and vice versa), whichmeans that the sound remains totally unaected. The ULTRA-DI PRO uses our proven OT-1 transformer which ensures a clear and distortion-free sound and linear frequency response. Additionally, the ULTRA-DI PRO comes with a built-in power supply.
Future-oriented BEHRINGER technology
The ULTRA-DI PRO is based on SMD technology (Surface Mounted Devices). Thesesubminiature components known from aerospace applications ensure both extreme packing density and greater reliability.
Please register your new BEHRINGER equipment right after your purchase by visiting http://behringer.com and read the terms and conditions of our warrantycarefully.
Should your BEHRINGER product malfunction, it is our intention to have it repaired as quickly as possible. To arrange for warranty service, please contact the BEHRINGER retailer from whom the equipment was purchased. Shouldyour BEHRINGER dealer not be located in your vicinity, you may directly contact one of our subsidiaries. Corresponding contact information is included in the original equipment packaging (Global Contact Information/European Contact Information). Should your country not be listed, please contact the distributor nearest you. A list of distributors can be found in the support area of our website (http://behringer.com).
Registering your purchase and equipment with us helps us process your repair claims more quickly and eciently.
Thank you for your cooperation!
5 ULTRA-DI PRO DI4000 User Manual

1.3 Control elements

The BEHRINGER ULTR A-DI PRO has four identical channels. The control elements are identical on all channels.
(6) (7)
(2) (4)(1) (3) (5)
Fig. 1.1: Control and display e lements on the fr ont panel
(1) OUTPUT. This is the balanced output of the ULTRA-DI PRO. The connection
to the mixing desk should be made with a standard high-quality balancedcable.
(2) +20 dB gain switch for pre-amplication of low level signals.
(3) Switchable HIGH CUT lters (8 kHz) for guitar applications (6 dB/Oct).
(4) With the PHASE REVERSE switch the input signal is reversed in phase
by180°.
(5) Use the GND LIFT switch to either connect the ground of input and output
or keep them completely separate. Depending on the grounding of the connected devices linking or disconnecting will reduce hum or prevent ground loops. GROUND LIFT on means no interconnection.
by fuses of the same type and rating. Some models allow for inserting the fuse holder in two dierent positions, in order to switch over from 230 V to 115 V operation, and vice versa. Please note that for 115 V operation outside Europe, you need to use a fuse of a higher rating (see chapter3 “Installation”). Use the enclosed power cord to connect the unit to themains.
(12) To provide maximum exibility the ULTRA-DI PRO is also tted with an
unbalanced XLRINPUT to connect the source.

2. Applications

2.1 Tapping signal from a (bass) guitar

Microphone Input
Out
DI4000
In Link Out
(6) The OUTPUT LEVEL meter displays the output level of the Ultra-DI PRO in a
range from -24dB to +18dB.
(7) Use the POWER switch to turn on the BEHRINGER U LTRA-DI PRO.
(11)
(12)
(13)
(10)(8) (9)
Fig. 1.2: Rear pa nel elements of the B EHRINGER Ultra-DI PR O
(8) LINK. This is the unbalanced parallel output of the ULTRA-DI PRO.
Connectthis to the input of the backline or monitor amplier.
(9) INPUT. Connect the source to this ¼" jack to input the signal.
(10) and (13) The -20 dB ATTENUATION switches greatly increase the operating
range of the ULTRA-DI PRO. From the low level signals of a high impedance guitar to the hot speaker terminals of a PA amplier. Depressingboth will give 40 dB attenuation.
Only use the ‑20 dB switches if you are sure the Ultra‑DI PRO is
clipping (overloading) and not your mic pre‑amp. Always use as little attenuation as possible to get the best possible signal‑to‑noise ratio.
(11) FUSE HOLDER/VOLTAGE SELECTOR. Please make sure that the voltage
indicated on the unit matches your local voltage, before you attempt to connect and operate the VINTAGER AC112. Blown fuses may only be replaced
Fig. 2.1: Guitar DI box Guitar Amp/Mixer
This gure shows the standard application of any Direct Inject box. The signal to the amplier is unaected, it is just tapped o to be routed to the microphone input of the mixer. Especially bass guitars benet from this application. It is dicult to nd a microphone which handles high level low frequencies well and with a linear frequency response. Using the ULTRA-DI PRO will give you clean and crisp sound. Connect the ULTRA-DIPRO after any eects devices, so that their eect will be heard over the PA system or on the recording.

2.2 Converting the output of a keyboard / DJ-mixer / headphone plug

Out OutIn In
Microphone Inputs Pan left and right
Fig. 2.2: DJ-m ixer 2 x D I box mixer
6 ULTRA-DI PRO DI4000 User Manual
This conguration can be used with a keyboard, DJ-mixer, headphone output, drum kit or any (stereo or mono) line source. In all cases where you want to run long lines, for instance to the FOH (Front Of House) desk. The signal can be linked through to another amplier, if the keyboard player/ DJ/etc. wants to have a monitor connected independent of the foldback mix. The ULTRA-DI PRO acts as both a ground isolator and an unbalanced to balanced converter.

2.3 Converting a microphone signal

OutIn
Fig. 2.3: Connecting a microphone
Sometimes all that’s available (especially when all other mics are in use) is an unbalanced high impedance microphone with an unbalanced jack. With the ULTRA-DI PRO long cable runs to the console can be established without fear of picking up noise and hum. Just plug the jack into the input and connect the output to the console’s mic input.

3. Installation

Your BEHRINGER ULTRA-DI PRO was carefully packed in the factory and the packaging was designed to protect the unit from rough handling. Nevertheless,werecommend that you carefully examine the packaging and its contents for any signs of physical damage, which may have occurred in transit.
If the unit is damaged, please do not return it to us, but notify your
dealer and the shipping company immediately, otherwise claims for damage or replacement may not be granted. Shipping claims must be made by the consignee.

3.1 Rack mounting

The BEHRINGER ULTRA-DI PRO ts into one standard 19" rack unit of space. Pleaseallow at least an additional 4" depth for the connectors on the back panel.
Be sure that there is enough air space around the unit for cooling and
please do not place the ULTRA‑DI PRO on high temperature devices such as power amplifiers etc. to avoid overheating.

3.2 Mains connection

The mains connection of the ULTRA-DI PRO is made by using a mains cable and a standard IEC receptacle. It meets all of the international safety certicationrequirements.
Please make sure that all units have a proper ground connection.
For your own safety, it is advisable not to remove the ground connection within the units or at the supply, or fail to make this connection at all.
2.4 Tapping a signal from a power amplieroutput
When no line out is available it is possible to connect an amplier output directly to the DI4000 (for example, recording direct from a guitar amplier, TV-speaker, etc). It is possible to connect the output, i.e. an extra speaker output, of up to 3000 Watts to the ULTRA-DI PRO without fear of overloading. Pay attention to the two -20 dB buttons on the ULTRA-DI PRO! Both must be depressed if an amplier output is connected to the DI4000 input.
+red or positive post
-black or negative post
Out
In
-20 / -40 dB!
Fig. 2.4: Connec tion to an amplier o utput
Always make sure the GROUND LIFT is on (no ground link)
when connecting to speaker terminals. This prevents accidental short‑circuiting of the amplifier output. Also make sure the tip of the input jack is connected to the red terminal and that the metal housing of the DI4000 has no contact with other equipment.
Before you switch on the unit, check that it is congured to match your AC mains voltage requirements. If it does not comply, then it is necessary to switch the operating voltage to the correct supply requirements BEFORE turning on the unit, otherwise the unit could be severely damaged. You will nd this combined fuse holder/voltage selector at the back, adjacent to the IEC receptacle.
IMPORTANT:This does not apply for general export models which are built for one operating voltage only.
The AC voltage selection is dened by the position of the fuse holder. If you intend to change the operating voltage, remove the fuse holder and twist it by 180 degrees before you reinsert it. Matching the two markers shows the selectedvoltage.
If the unit is switched to another operating voltage, the fuse rating
must be changed. See the technical specifications in the appendix.
A safety fuse protects the unit from serious defects. If the fuse blows, this is a warning sign and always indicates that the circuit is overloaded. The fault must always be repaired before the fuse is replaced. If the safety fuse is faulty and needs replacing after the unit is repaired, please make sure that you replace it only with the identical type and rating. NEVER use fuses of dierent ratings or cover faulty fuses with aluminium foil. This can cause re and electric shocks and will endanger your life and the lives of others.

3.3 Audio connections

As standard, the BEHRINGER ULT RA-DI PRO is installed with transformer­balanced outputs. This transformer features automatic hum and noise reduction for balanced signals and thus allows for trouble-free operation, even at high operating levels. Externally induced mains hum etc. will be eectivelysuppressed.
Please ensure that only qualified persons install and operate the
ULTR A‑DI PRO. During installation and operation the user must have sufficient electrical contact to earth. Electrostatic charges might affect the operation of the ULTRA‑DI PRO!
7 ULTRA-DI PRO DI4000 User Manual
tupnIelbaCtuptuO
Pin 1
Pin 2 = (+) Signal
12
3
Pin 3 = (-) Signal
Fig. 3.1: Compensation of interference with balanced connections
Unbalanced use of mono ¼" jack plugs
strain relief clamp
sleeve
tip
sleeve
(ground/shield)
tip
(signal)
(+) Signal + Hum
(-) Signal + Hum
RFI and Hum
Shield
Ground
1
2
3
Positive
Negative
Balanced use with XLR connectors
12
3
input
1 = ground/shield 2 = hot (+ve) 3 = cold (-ve)
1
2
3
output
For unbalanced use, pin 1 and pin 3 have to be bridged
(+) Hum + Signal
(-) Hum + Signal
2 x Signal
= Signal + 6 dB
Balanced use of stereo ¼" jack plugs
strain relief clamp
sleeve ring tip
sleeve
ground/shield
ring
cold (-ve)
tip
hot (+ve)
For connection of balanced and unbalanced plugs, ring and sleeve have to be bridged at the stereo plug.
Fig. 3.2: Di erent plug type s
8 ULTRA-DI PRO DI4000 User Manual
4. Specications
Audio Input
Connectors XLR and ¼" jack
Type DC-decoupled, unbalanced input
Impedance max. 220 kOhm
Max. input level +20/+40/+60 dBu
Audio Output
Connectors XLR
Type transformer-balanced output stage
Impedance 600 Ohms balanced
Max. output level +20dBu
System Specications
Bandwidth (100 kOhm) 23Hz to 120 kHz (±3 dB)
Bandwidth (600 Ohm) 23Hz to 27 kHz (±3 dB)
Bandwidth (High Cut) 10 Hz to 8 kHz (±3 dB)
Noise -95 dBu
Power Supply
Mains Voltages
USA/Canada 120 V~, 60Hz
U.K./Australia 240 V~, 50Hz
Europe 230 V~, 50Hz
General export model 100 - 120 V~, 200 - 240 V~, 50 - 60Hz
Power consumption max. 10 Watts
Fuse 100 - 120 V~: T 200 mA H
200 - 240 V~: T 100 mA H
Mains connection standard IEC receptacle
Physical
Dimension 1 ¾ x 19 x 8 ½"
44.5 x 483 x 215 mm
Net weight 5.9 lbs / 2.7 kg
Shipping weight 7.9 lbs / 3.6 kg
BEHRINGER i s constantly str iving to maintain the h ighest profess ional standards. A s a result of these e ffort s, modific ations may be made f rom time to time to exi sting product s without prio r notice. Specif ications and appearance m ay differ fro m those listed or illus trated.
We Hear You