BAUKNECHT EMEK9 P545 BM Extended Technical Drawing

0

0

0

 

 

-

568

 

453-450

560

 

0

550

 

 

 

 

-462

 

550

 

-568

460

560

 

 

 

561

540

557

10

95

445

455

 

0

595

 

20

 

 

348

 

85°

 

4

6

BAUKNECHT EMEK9 P545 BM Extended Technical Drawing

EMEK9 P545 BM

12NC/Fx: 859991576370

GTIN (EAN) code:

 

 

4011577618877

DIMENSION

MEASURE

OVERALL CABINET

 

 

 

MIN Height of the wall cabinet niche, including all required space for installation or ventilation

0

mm

 

MIN Height of the tall cabinet niche, including all required space for installation or ventilation

450

mm

MIN Height of the base cabinet niche, including all required space for installation or ventilation

460

mm

 

MAX Height of the wall cabinet niche, including all required space for installation or ventilation

0

mm

MAX Height of the tall cabinet niche, including all required space for installation or ventilation

453

mm

 

MAX Height of the base cabinet niche, including all required space for installation or ventilation

462

mm

MIN Width of the wall cabinet niche, including all required space for installation or ventilation

0

mm

 

MIN Width of the tall cabinet niche, including all required space for installation or ventilation

560

mm

MIN Width of the base cabinet niche, including all required space for installation or ventilation

560

mm

 

MAX Width of the wall cabinet niche, including all required space for installation or ventilation

0

mm

MAX Width of the tall cabinet niche, including all required space for installation or ventilation

568

mm

 

MAX Width of the base cabinet niche, including all required space for installation or ventilation

568

mm

MIN Depth of the wall cabinet niche, including all required space for installation or ventilation

0

mm

 

MIN Depth of the tall cabinet niche, including all required space for installation or ventilation

550

mm

MIN Depth of the base cabinet niche, including all required space for installation or ventilation

550

mm

 

Space in front, which is required to install bottom trim

6

mm

Indicates whether a ventilation opening is needed or not. Default is "N"

No

 

 

WALL CABINET (vent-shaft incoming)

 

 

 

Indicates the position of the freespace for the inbound airflow (wall cabinet)

-

 

 

Minimum space or inbound ventilation (wall cabinet)

0

mm

Minimum area for inbound ventilation cavity (wall cabinet)

0

cm²

 

WALL CABINET (vent-shaft outgoing)

 

 

 

Indicates the position of the freespace for the outbound airflow (wall cabinet)

-

 

 

Minimum space or outbound ventilation (wall cabinet)

0

mm

Minimum area for outbound ventilation cavity (wall cabinet)

0

cm²

 

TALL CABINET (vent-shaft incoming)

 

 

 

Indicates the position of the freespace for the inbound airflow (tall cabinet)

-

 

 

Minimum space for inbound ventilation (tall cabinet)

0

mm

Minimum area for inbound ventilation cavity (tall cabinet)

0

cm²

 

TALL CABINET (vent-shaft outgoing)

 

 

 

Indicates the position of the freespace for the outbound airflow (tall cabinet)

-

 

 

Minimum space for outbound ventilation (tall cabinet)

0

mm

Minimum area for outbound ventilation cavity (tall cabinet)

0

cm²

 

BASE CABINET (vent-shaft incoming)

 

 

 

Indicates the position of the freespace for the inbound airflow (base cabinet)

-

 

 

Minimum space for inbound ventilation (base cabinet)

0

mm

Minimum area for inbound ventilation cavity (base cabinet)

0

cm²

 

BASE CABINET (vent-shaft outgoing)

 

 

 

Indicates the position of the freespace for the outbound airflow (base cabinet)

-

 

 

Minimum space for outbound ventilation (base cabinet)

0

mm

Minimum area for outbound ventilation cavity (base cabinet)

0

cm²

 

 

 

 

 

DIMENSION

MEASURE

APPLIANCE

 

 

 

Height of the front

 

455

mm

Width of the front

 

595

mm

Depth of the front

 

20

mm

Maximum depth all protruding elements, e.g. handles, controls

 

40

mm

Lateral clearance between front edge and most protruding elements which avoid to open a

 

0

mm

neighbour front more than 90 degrees

 

 

 

Projection of front in relation to housing of appliance

 

10

mm

Projection of front in relation to bearing area of the appliance. Taken at minimum height of

 

0

mm

appliance, if height is adjustable

 

 

 

When product panel is missing, set to 0

 

95

mm

Space in front, which is required to guarantee full operability. The most protruding part gives this

348

mm

dimension

 

 

 

Height from bearing area of appliances and lower handle

 

285

mm

Frontal handle thickness

 

30

mm

Frontal handle width

 

521

mm

MIN Height of the product body

 

445

mm

MAX Height of the product body

 

445

mm

Width of the product body

 

557

mm

Depth of the product body

 

540

mm

Full depth of product excluding protruding interface elements

 

561

mm

Minimum height from bottom line hood to top line air outlet

 

0

mm

Maximum height from bottom line hood to top line air outlet

 

0

mm

Diameter minimum air outlet

 

0

mm

Diameter maximum air outlet

 

0

mm

Indicates measure between center of air outlet hole and rear wall

 

0

mm

Projection of the rear flap in relation to bearing area

 

0

mm

Height tube connection for air outlet

 

0

mm

Appliance can be used as base for other appliances from the same manufacturer. Default is "No"

-

 

Appliance Flap door

 

 

 

Projection of the opened flap in relation to bearing area

 

4

mm

Maximum angle when flap door is opened totally

 

85

mm

Appliance Side swing door

 

 

 

Lateral projection of front incl. controls when door is opened totaly. At the side where the hinge is

0

mm

mounted

 

 

 

Lateral projection of opened front at the side where the hinge is fixed

 

0

mm

Maximum angle when door is opened totally

 

0

mm

Appliance other

 

 

 

Depth from front end of the niche to the front end of the freespace of the retrace

 

0

mm

Height from niche to bottom end of freespace for the retrace

 

0

mm

Loading...