WH-Series Refrigerant 22 60Hz
Heating Capacities: 18,800 to 58,000 BTUH
Cooling Capacities: 19,000 to 56,500 BTUH
The Bard Wall-Mount Heat Pump is a self-contained energy efficient heating and
cooling system, which is designed to offer maximum indoor comfort at a minimal
cost without using valuable indoor floor space or outside ground space. This unit is
the ideal product for versatile applications such as: new construction, modular
offices, school modernization, telecommunication structures, portable structures or
correctional facilities. Factory or field installed accessories are available to meet
specific job requirements.
Engineered Features
Aluminum Finned Copper Coils:
Grooved tubing and enhanced louvered
fin for maximum heat transfer and
energy efficiency.
Twin Blowers:
Move air quietly. Most models feature
multispeed blower motors providing
airflow adjustment for high and low static
operation. Motor overload protection is
standard on all models.
Heat Pump Compressor:
Reciprocating compressor designed to
withstand higher compressor ratios and
longer operation than normal air
conditioning compressors. Equipped
with crankcase heater and dual
discharge muffler. Standard on all 2, 2½,
3 and 3½ ton models.
Scroll compressor designed for
increased efficiency, quieter operation
and improved reliability for longer life.
Eliminates need for crankcase heater
and suction accumulator. Standard on
all 1½, 4 and 5 ton models.
Galvanized 20 Gauge Zinc Coated
Steel Cabinet:
Cleaned, rinsed, sealed and dried
before the polyurethane primer is
applied. The cabinet is handsomely
finished with a baked on, beige textured
enamel, which allows it to withstand
1000 hours of salt spray tests per ASTM
B117-03.
Electrical Components:
Are easily accessible for routine
inspection and maintenance through a
right side, service panel opening.
Features a lockable, hinged access
cover to the circuit breaker or pull
disconnect switch.
Electric Heat Strips:
Features an automatic limit and thermal
cut-off safety control. Heater packages
are factory or field installed for all 1½
through 5 ton models. Features easy
slide-in field assembly with various
BTUH outputs.
Condenser Fan and Motor
Shroud Assembly:
Slide out for easy access.
One Inch, Disposable Air Filters:
Are standard equipment. Optional one
inch washable filters available and
filter racks permit the addition of 2"
pleated filter. Factory or field installed.
Solid State Electronic Heat Pump
Control:
Provides efficient 30, 60 or 90 minute
defrost cycle. A thermistor sensor,
speed up terminal for service and 10
minute defrost override are standard on
the electronic heat pump control.
High Pressure Switch:
Is built-in with a lockout circuit that
resets from the room thermostat.
Five Minute Compressor Time
Delay:
Short cycle protection is standard. Built
into the heat pump control.
Suction Accumulator:
Protects the reciprocating compressor
from refrigerant flood back and prevents
damage to the compressor bearing
surfaces. Not required on scroll
compressor applications.
Emergency Heat Circuit:
Permits continuous operation of the
system.
Barometric Fresh Air Damper:
Standard on all units. Allows up to 25%
outside fresh air.
Built-in Circuit Breakers:
Standard on all electric heat versions of
single and three phase (230/208 volt)
equipment. Toggle disconnects are
standard on all electric heat versions of
three phase (460 volt) equipment.
Slope Top:
Standard feature for water run-off.
Full Length Mounting Brackets:
Built into cabinet for improved
appearance and easy installation.
NOTE: Bottom mounting bracket
included to assist in installation.
Top Rain Flashing:
Standard feature on all models.
Ventilation System Packages
All packages are designed
to meet your specific
ventilation requirements
utilizing one of six
ventilation options for the
product. The ventilation
package is mounted within
the unit eliminating the
need for an exterior
mounted hood or damper
assembly on the unit. All
assemblies can be factory
installed, installed in the
field at time of installation
or as a retrofit system after
installation.
• Standard - Barometric
Fresh Air Damper
• Optional - Motorized
Fresh Air Damper
• Optional - Blank off Plate
• Optional - Commercial
Room Ventilator w/Exhaust
• CRV - Spring Return
• CRVP - Power Return
• Optional - Economizer
with Exhaust
• Optional - Energy
Recovery Ventilator
• Complies with efficiency requirements of ASHRAE/IESNA 90.1-2004.
• Certified to ARI Standard 390-2003 for SPVU (Single Package Vertical Units).
• Commercial Product - Not intended for Residential application.
1 Capacity is certified in accordance with ARI Standard 390-2003 and tested in accordance with ARI Standard 210/240-2003.
2 EER = Energy Efficiency Ratio, COP = Coefficient of Performance and are certified in accordance with ARI Standard 390-2003.
3 SEER =
Seasonal Energy Efficiency Ratio, HSPF = Heating Seasonal Performance Factor and are tested in accordance with ARI Standard 210/240-2003.
All ratings based on fresh air intake being 100% closed (no outside air introduction).
Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All
units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the
factory, or field-installed at a later date.
BAROMETRIC FRESH AIR DAMPER - BFAD STANDARD
The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door
and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air
inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes
when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the
building and can be easily locked closed if required.
Barometric Fresh Air Damper
Motorized Fresh Air Damper
Commercial Room Ventilator
Economizer
BLANK OFF PLATE - BOP OPTIONAL
A blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any
outside air from entering into the unit. The blank off plate should be utilized in applications where outside air is not
required to be mixed with the conditioned air.
MOTORIZED FRESH AIR DAMPER - MFAD OPTIONAL
The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to
25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the
conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a
24VAC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be
field connected to be managed based on building occupancy.
NOTE: The above vent systems are intake only without built-in exhaust capability. Building will likely require separate
field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Balancing dampers in
the return air grille may be required to achieve specified amount of outdoor air intake.
COMMERCIAL ROOM VENTILATOR - CRVOPTIONAL
The built-in commercial room ventilator is internally mounted behind the service door and allows outside
ventilation air, up to 50% of the total airflow rating of the unit, to be introduced through the air inlet openings.
It includes a built-in exhaust air damper.
The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by
providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the
amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field
controlled based on room occupancy. Two versions available (except on 1.5 and 2-Ton models). The CRV and
CRVS are power open - spring return on power loss, and CRVP is power open and power close. Complies with
ANSI/ASHRAE Standard 62.1 “Ventilation for Acceptable Indoor Air Quality.”
ECONOMIZER - EIFMOPTIONAL
The built-in economizer system is internally mounted behind the service door and allows outdoor air to be
introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and
settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide
“free cooling” when outside air conditions are cool and dry enough to satisfy cooling requirements without running
the compressor. This in turn provides lower operating costs, while extending the life of the compressor.
Standard Features:
• One Piece Construction - Easy to install with no mechanical linkage adjustment required.
• Exhaust Air Damper - Built in with positive closed position. Provides exhaust air capability to prevent
pressurization of tight buildings.
• Actuator Motor - 24 volt, power open, spring return with built in torque limiting switch.
• Proportioning Type Control - for maximum “free cooling” economy and comfort.
• Enthalpy Control - adjustable to monitor outdoor temperature and humidity.
• Minimum Position Potentiometer - adjustable to control minimum damper blade position for ventilation
purposes.
• Mixed Air Sensor - to monitor outside and return air to automatically modulate damper position.
Energy Recovery Ventilator
WALL-MOUNT ENERGY RECOVERY VENTILATOR - WERVOPTIONAL
The wall-mount energy recovery ventilator (WERV) is a highly innovative approach to meeting indoor air quality
ventilation requirements as established by ANSI/ASHRAE Standard 62.1. The WERV allows from 200 to 450 CFM
(depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and
humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs.
Heat transfer efficiency is up to 67% during summer and 75% during winter conditions.
The WERV consists of a unique “rotary energy recovery cassette” that provides effective sensible and latent heat
transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting
ventilation during building occupancy only.
The WERV is designed to be internally mounted behind the service door in the WA, WH or WL model wall-mount
units. It can be built-in at the factory or field installed as an option. WERV-*3C and WERV-*5C can be
independently adjusted for intake and exhaust rates.
Manufactured under U.S. Patent Nos. 5,485,878; 5,301,744;
5,002,116; 4,924,934; 4,875,520; 4,825,936; 6,310,330.
Form No.S3210-206
SupersedesS3210-106
Page3 of 12
0
100
200
300
400
500
600
700
800
900
1000
ABCDEF
Vent Position
Airflow (cfm)
Total Air 0 ESP
Total Air .15 ESP
Total Air .3 ESP
Vent Air 0 ESP
Vent Air .15 ESP
Vent Air .3 ESP
WH30 & WH36 LOW SPEED TOTAL AND VENTILATION AIRFLOW
Total Air 0 ESP
Total Air .15 ESP
Total Air .3 ESP
Vent Air 0 ESP
Vent Air .15 ESP
Vent Air .3 ESP
Total Air 0 ESP
Total Air .15 ESP
Total Air .3 ESP
Vent Air 0 ESP
Vent Air .15 ESP
Vent Air .3 ESP
Vent Position
Vent Position
WH18 & WH24 TOTAL AND VENTILATION AIRFLOW
ABCDEF
ABCDEF
0
100
200
300
400
500
600
700
800
900
1000
Commercial Room Ventilator Performance Data - CRV-2
Form No.S3210-206
Supersedes S3210-106
Page4 of 12
1100
Airflow (cfm)
WH30 & WH36 HIGH SPEED TOTAL AND VENTILATION AIRFLOW
Commercial Room Ventilator Performance Data - CRVS-3 and CRVP-3
1200
1100
1000
900
600
700
800
400
500
Airflow (cfm)
300
0
100
200
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.