INSTALLATION INSTRUCTIONS
MOTORIZED
FRESH AIR DAMPER
MODEL
WGMFAD-3A
WGMFAD-5A
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
Since 1914...Moving ahead just as planned.
Manual : 2100-362D
Supersedes: 2100-362C
File: Volume III Tab 19
Date: 02-25-10
Manual 2100-362D
Page 1 of 10

CONTENTS
Description ......................................................... 3
Application.......................................................... 3
Installation Instructions ...............................4 & 5
Wiring Diagram................................................. 10
Figures
Figure 1 Vent Option Door.................................. 6
Figure 2 Exhaust Cover Plates ........................... 6
Figure 3ARouting of Wires ................................... 7
Figure 3BProper Installation ................................. 7
Figure 4 Thermostat Diagram ................................8
Figure 5 Gas Electric Connection ..........................9
Tables
Table 1 WGMFAD-3A Ventialtion Air ................. 3
Table 2 WGMFAD-3A Ventialtion Air ................. 4
Table 3 WGMFAD-5A Ventialtion Air ................. 5
Manual 2100-362D
Page 2 of 10

DESCRIPTION
The motorized fresh air damper WGMFAD is an
internally mounted damper designed to bring in up to
25% fresh air. The damper blade is powered by a 24
VAC motor with spring return on power loss. The
damper is powered open anytime the unit blower motor
is energized.
This ventilation device does not include an exhaust
provision. Depending on the tightness of the structure,
an independent exhaust provision may be needed to
obtain the ventilation air quantities shown.
WGMFAD-3A VENTILATION AIR
For use with W24G Model
DEEPSHGIH
citatSriAylppuS )MFC(riAlatoT/riAnoitalitneV
00.05231/0510031/0335721/0840421/0060021/0860411/0370601/057
02.00911/0210511/0130311/5640901/0855301/066589/007529/027
04.00401/0110001/092049/044088/055548/046067/096AN
citatSnruteR00.050.001.051.002.052.003.0
APPLICATION
The amount of outside fresh air brought into the
structure is dependent on the supply and return duct
static pressure present in the duct system. Refer to
Table for ventilation air that will be supplied at different
duct static pressure for the model installed.
For free blow applications with return air filter grille
and supply grille, use 0.00 supply air static pressure and
0.1 return air static pressure.
TABLE 1
WOLDEEPS
MUIDEMDEEPS
citatSriAylppuS )MFC(riAlatoT/riAnoitalitneV
00.00311/0410901/0035701/0540501/0750001/076049/027058/047
02.00001/011089/072059/024019/045078/056028/007067/027
04.0088/001068/052008/004057/025ANANAN
citatSnruteR00.050.001.051.002.052.003.0
citatSriAylppuS )MFC(riAlatoT/riAnoitalitneV
00.0009/031088/092068/034038/055008/056057/007AN
02.0028/001097/052037/004007/025ANANAN
04.0007/09ANANANANANAN
citatSnruteR00.050.001.051.002.052.003.0
Manual 2100-362D
Page 3 of 10