MINI-SCREEN Controller Models
MSDINT-1 and MSDINT-1L2
Supplement to MINI-SCREEN Instruction Manual 44895
Printed in USA 04/00 P/N 62875
Figure 20. MINI-SCREEN System electrical connections.
Figure 17. Control Module Dimensions and Mounting Hole Locations.
The enclosed MINI-SCREEN controller MSDINT-1, MSDINT-1L2, or replacement board reflect the new MINI-SCREEN DIN controller design. These controllers are identical to the old MINI-SCREEN DIN controller, except that they have removeable wiring blocks. With the removeable wiring blocks, wiring terminal numbers change and one overall controller dimension increases. This supplement modifies the information for figures 17, 20, and 23, which appear in MINI-SCREEN manual 44895.
110.0 mm (4.33")
100.0 mm (3.94 ")
7.4 mm (0.29")
60.8 mm
(2.40")
85.3mm (3.36")
35.0 mm (1.38")
DIN Mounting Slot
Combo Head (Phillips/Slotted) Screws M3.5 x 0.6 mm x 14 mm (2) (#6 x 0.5" equivalent) (Supplied)
M3.5 mm Washers (2) (#6 equivalent) (Supplied) M3.5 mm x 0.6 mm Nuts (2) (36 equivalent) (Supplied)
Recommended torque is 16 in-lbs on mounting screws
83.8 mm (3.30")
7.1 mm (0.28")
DIN Mounting Tab
(Supplied)
Slot for Screws (2) M3.5 x 0.6 mm (2)
+24
SSD
18
19
MINI-SCREEN
MODEL NO.
MSDINT-1 or 1L2
LISTED
Presence Sensing Device
10Y8
123OK
Diagnostic
Chart on
Reverse Side
FSD2
22
0466
23
FSD1
27
CAUTION
Shock hazard may exist.
28
!
operation always follow the
Blocked or Latched
instructions in the manual.
Clear
Reset
BANNER ENGINEERING CORP., USA
WARNING
For control reliable
(612) 544-3164
V dcdcCom
32 33 34
Lockout
Blanking
Alignment
PE
12
AUX
or
ALARM
Test 1
or
LATCH
RESET 1
45
Test 2
or
LATCH
RESET 2
89
Key 1 Key 2
15 16 17
13 14
+12VdcCOM T/R T/R DRAIN
Page 2
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: (763) 544-3164 • Fax: (763) 544-3573 • E-mail: sensors@baneng.com
MSDINT-1 or MSDINT-1L2
WARNING. . .
Use of MINI-SCREEN Systems for Perimeter Guarding
If control module model MSDINT-1T2 is used for perimeter guarding, the Machine Primary Control Elements (MPCEs) of the guarded machine must be wired so that the trip output of the control module causes a latched response of the MPCEs. The MPCEs must be reset only by actuation of a reset switch.
The reset switch must be located outside of the area of dangerous motion, and must be positioned so that the area of the dangerous motion may be observed by the switch operator during the reset operation. Supplemental presence sensing devices, such as safety mats, must be used if any space between the defined area and any danger point is large enough to allow a person to stand undetected by the MINI-SCREEN System. Failure to observe this warning could result in serious bodily injury or death.
Figure 23. Generic machine interface, MINI-SCREEN System
WARNING. . .
All MINI-SCREEN System output contacts (FSD1, FSD2, and SSD)
must be used. The generalized wiring configuration, shown here, is
provided only to illustrate the importance of proper installation. The actual details of wiring of the MINI-SCREEN system to any particular machine is solely the responsibility of the installer and end user.
WARNING. . .
If arc suppressors are used, they MUST BE INSTALLED AS SHOWN
ACROSS THE COILS OF THE MACHINE CONTROL ELEMENTS.
NEVER INSTALL SUPPRESSORS DIRECTLY ACROSS THE CONTACTS OF THE MINI-SCREEN SWITCHING DEVICES! It is possible for suppressors to fail as a short circuit. If installed directly across the contacts of a
MINI-SCREEN switching device, a short-circuited suppressor will create an unsafe condition.
Figure 23 (below) shows output relay connections in a generic interfacing situation.
The connections between the MINI-SCREEN System outputs and the machine primary and secondary control elements must be direct, and arranged so that any single line fault or earth fault will not result in a circuit failure to a potentially dangerous state.
!
L (V ac)
or
+ (V dc)
+24V dc
Machine
Control
Circuit
MPCE 1 MPCE 2
MPCE
Monitor
Contacts
MPCE 1 MPCE 2
Model MSDINT-1: Trip Output Model MSDINT-1L2: Latch Output
Secondary Switching
Device
SSD
Final Switching
Device #2
FSD 2
Final Switching
Device #1
FSD 1
+ (V dc)
– (V dc)
18
19
22
23
27
28
32
33
34
Machine Secondary
Control Element
MSCE
Arc Suppression
(see warning)
Machine Primary
Control Element #2
MPCE
Arc Suppression
(see warning)
Machine Primary
Control Element #1
MPCE
Arc Suppression
(see warning)
2
1
N (V ac)
or
common (V dc)
MINI-SCREEN Control Module
Earth
Grounddccommon
!
!
Loading...