Banner MQDC1-506, MQDC1-515, MQDC1-530, MQDC1-506RA, MQDC1-515RA Installation Manual

...
!
P
bn bu wh bk gy
+
10 - 30V dc
Load Load
LO/DO Select
bn bu wh bk
+
10 - 30V dc
No Connection
gy
bn
bu
-
+
10-30V dc
bn bu wh bk
+
10 - 30V dc
Load Load
gy
LO/DO Select
WORLD-BEAM
®
QS30 – DC Voltage
Compact, self-contained photoelectric sensors in universal-style housing
Additional information on this product is immediately available online at www.bannerengineering.com/119165
View or download additional information, including excess gain curves, beam patterns and accessories.
For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.
Sensing Mode Range Output Model*
875 nm Infrared
Effective Beam:
18 mm (0.7")
630 nm Visible Red
Opposed
Retroreflective
60 m (200')
12 m (40')
Installation
Guide
QS30E
QS30R
QS30LV
Cabled Emitters
QD Emitters
(5-pin Euro-Style)
All Other Cabled Models
All Other QD Models
(5-pin Euro-Style)
630 nm Visible Red
Polarized Retro­reflective
8 m (26')
Bipolar
QS30LP
NPN/PNP
940 nm Infrared
Diffuse
680 nm Visible Red
Fixed-Field
1 m (3.3')
200 mm (8")
400 mm (16")
600 mm (24")
QS30D
QS30FF200
QS30FF400
QS30FF600
* Only standard 2 m (6.5') cable models are listed. For 9 m (30') integral cable, add suffix “W/30” to
the model number (e.g., QS30E W/30). QD models: For 5-pin integral Euro-style QD, add suffix “Q” (e.g., QS30EQ).
Range is specified using a model BRT-84 retroreflector.
Dimensions
Cabled Models
QD Models
WARNING . . .
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
Not To Be Used for Personnel Protection
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Printed in USA 04/09 P/N 119167 rev. A
WORLD BEAM® QS30 – DC Voltage
White Wire
Blue Wire
Black Wire
Brown Wire
Gray Wire
M12 x 1
ø 15 mm
(0.6")
44 mm max.
(1.7")
38 mm max.
(1.5")
M12 x 1
ø 15 mm
(0.6")
38 mm max.
(1.5")
Specifications
Supply Voltage and Current
10 to 30V dc (10% maximum ripple) at less than 40 mA, exclusive of load
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Bipolar: One current sourcing and one current sinking Rating: 100 mA maximum each output at 25°C Off-state leakage current: NPN: less than 200 µA PNP: less than 10 µA ON-state saturation voltage: NPN: less than 1.6V @ 100 mA
PNP: less than 2.0V @ 100 mA
Protected against false pulse on power-up and continuous overload or short
circuit of outputs
Output Response Time
Opposed Mode: 5 milliseconds ON and OFF All others: 2 milliseconds
NOTE: 100 millisecond delay on power-up; outputs do not conduct during
this time
Repeatability
Opposed Mode: not applicable All others: 500 microseconds
Cutoff Point Tolerance Fixed-Field only: ±5% of nominal cutoff distance
Indicators
2 LED indicators on sensor top: Green ON steady: Power ON Yellow ON steady: Light sensed Green flashing: Output overloaded Yellow flashing: Marginal excess gain
(except receivers) (1.0 to 1.5x excess gain)
Large oval LED indicator on sensor back (except emitters): Yellow ON steady: Output conducting
Adjustments Diffuse, Retroreflective, and Polarized Retroreflective mode models:
Single-turn Sensitivity (Gain) adjustment potentiometer All models: Selectable Light/Dark Operate is achieved via the gray wire, as described below. Opposed, Retroreflective, and Polarized Retroreflective models: Light Operate - Low (0 to 3V)* Dark Operate - High (open or 5 to 30V)* Diffuse and Fixed-Field models: Light Operate - High (open or 5 to 30V)* Dark Operate - Low (0 to 3V)*
* Input impedance 10 kΩ
Construction ABS housing, rated IEC IP67; NEMA 6; Acrylic lens cover
3 mm mounting hardware included
Connections
2 m (6.5') or 9 m (30') 5-wire PVC cable, or 5-pin Euro-style integral QD
connector
Operating Conditions
Temperature: -20° to +70° C (-4° to +158° F) Relative Humidity: 90% @ 50° C (non-condensing)
Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements method 201A (vibration: 10
to 60 Hz max., double amplitude 0.06", maximum acceleration 10G). Also meets IEC 947-5-2; 30G 11 ms duration, half sine wave.
Certifications
Style Model Length Dimensions Pin-Out
5-pin Euro-style straight
5-pin Euro-style right-angle
MQDC1-506 MQDC1-515 MQDC1-530
MQDC1-506RA MQDC1-515RA MQDC1-530RA
2 m (6.5')
5 m (15') 9 m (30')
2 m (6.5')
5 m (15') 9 m (30')
Additional information on this product is immediately available online at www.bannerengineering.com/119165
View or download additional information, including excess gain curves, beam patterns and accessories.
For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.
P/N 119167 rev. A
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com
Quick-Disconnect (QD) Cables
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for
one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.
Loading...