DF-G1 Expert™ Dual Display Fiber Amplifier
Installation Guide
Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies.
For complete technical information about this product, including dimensions, accessories, and specifications, see
www.bannerengineering.com and search 161999.
Overview
1 Output LED
2 LO/DO Switch
3 RUN/PRG/ADJ Mode Switch
4 Lever Action Fiber Clamp
5 Red Signal Level
6 Green Threshold
7 +/SET/- Rocker Button
Figure 1. DF-G1 Model Features
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
http://
Models
Model Outputs Connector
DF-G1-NS-2M Single NPN
DF-G1-PS-2M Single PNP
DF-G1-KS-2M Dual outputs, 1 push-pull IO-Link and 1
DF-G1-NS-Q5 Single NPN
DF-G1-PS-Q5 Single PNP
DF-G1-KS-Q5 Dual outputs, 1 push-pull IO-Link and 1
DF-G1-NS-Q7 Single NPN
DF-G1-PS-Q7 Single PNP
DF-G1-KS-Q7
1
Connector options:
• A model with a QD connector requires a mating cordset .
• For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G1-NS-9M).
• For 150 mm (6 in) PVC pigtail, M8 Pico QD connector, 4-pin change the suffix 2M to Q3 in the 2 m model number (example, DF-G1-NS-Q3).
PNP (complementary outputs)
PNP (complementary outputs)
Dual outputs, 1 push-pull IO-Link and 1
PNP (complementary outputs)
2 m (6.5 ft) cable, 4-wire
150 mm (6 in) PVC pigtail, M12 Euro QD connector,
4-pin
Integral M8 Pico QD connector, 4-pin
1
Original Document
161275 Rev. D
9 September 2015
Fiber Emitter
Port
Fiber Receiver
Fiber Clamp
Port
Move forward
to release the
fibers
DF-G1 Expert™
Installation Instructions
Mounting Instructions
Mount on a DIN Rail
1. Hook the DIN rail clip on the bottom of the DF-G1
over the edge of the DIN rail (1).
Push the DF-G1 up on the DIN rail (1).
2.
3. Pivot the DF-G1 onto the DIN rail, pressing until it
snaps into place (2).
Mount to the Accessory Bracket
1. Position the DF-G1 in the SA-DIN-BRACKET.
2. Insert the supplied M3 screws.
3. Tighten the screws.
Dual Display Fiber Amplifier
Remove from a DIN rail
1. Push the DF-G1 up on the DIN rail (1).
2. Pivot the DF-G1 away from the DIN rail and remove
it (2).
Installing the Fibers
Follow these steps to install glass or plastic fibers.
Open the dust cover.
1.
2. Move the fiber clamp forward to unlock it.
3. Insert the fiber(s) into the fiber port(s) until they
stop.
4. Move the fiber clamp backward to lock the fiber(s).
5. Close the dust cover.
Fiber Adapters
NOTE: If a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided
with the fiber assembly to ensure a reliable fit in the fiber holder. Banner includes the adapters with all
fiber assemblies.
2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 161275 Rev. D
TRANSMITTER
RECEIVER
Single-core fiber
Multi-core fiber
Remote
Programming
(N.O.)
10-30V dc
Load
Load
10–30 V dc
Remote
Programming
(N.O.)
(C/Q)
(Q)
PUSH-PULL
18-30V dc
Load
Load
DF-G1 Expert™ Dual Display Fiber Amplifier
Fiber Outer Diameter (mm) Adapter Color
Ø 1.0 Black
Ø 1.3 Red
Ø 2.2 No adapter needed
When connecting coaxial-type fiber assemblies to the amplifier, install the single-core fiber to the Transmitter port, and the
multi-core fiber to the Receiver port. This will result in the most reliable detection.
Wiring Diagrams
NPN Models
NOTE: Open lead wires must be connected to a terminal block.
IO-Link Models
PNP Models
Key
1 = Brown
2 = White
3 = Blue
4 = Black
P/N 161275 Rev. D www.bannerengineering.com - Tel: +1-763-544-3164 3