Baldor SUL50106SM Product Information Sheet

Product Information Packet
SUL50106SM
1HP,1150RPM,1PH,60HZ,180TY,XPNV,V1
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
Product Information Packet: SUL50106SM - 1HP,1150RPM,1PH,60HZ,180TY,XPNV,V1
Part Detail
Revision: A Status: PRD/A Change #: Proprietary: No Type: AC Elec. Spec: A00091A A 001 CD Diagram: Mfg Plant: Mech. Spec: Layout: 066930-701 Poles: 06 Created Date: 11-09-2018 Base: Eff. Date: 01-14-2020 Leads:
Specs
Catalog Number: SUL50106SM Enclosure: XPNV Frame: 180TY Frame Material: Iron Output @ Frequency: 1.000 @ 60 HZ Voltage @ Frequency: 230 V @ 60 HZ
115 V @ 60 HZ XP Class and Group: CLI GP C,D XP Division: Not Applicable Agency Approvals: UL
CSA
CCSA US Base Indicator: Rigid Bearing Grease Type: Polyrex EM (-20F +300F) Current @ Voltage: 17.2 A @ 115 V
8.60 A @ 230 V
Design Code: L
Duty Rating: CONT Heater Indicator: No Heater Insulation Class: F Inverter Code: Not Inverter IP Rating: NONE KVA Code: K Lifting Lugs: Standard Lifting Lugs Motor Type: M Mounting Arrangement: V1 Product Family: Pump - Centrifugal Pulley End Bearing Type: Ball Pulley Face Code: Standard Shaft Rotation: Fixed Opposite Standard Shaft Slinger Indicator: No Slinger Speed Code: Single Speed Motor Standards: NEMA Starting Method: Direct on line
Drip Cover: No Drip Cover
Thermal Device - Winding: Normally Closed Thermostat
Product Information Packet: SUL50106SM - 1HP,1150RPM,1PH,60HZ,180TY,XPNV,V1
XP Temp Code: T3C
Product Information Packet: SUL50106SM - 1HP,1150RPM,1PH,60HZ,180TY,XPNV,V1
Nameplate 000613007MN
CAT NO SUL50106SM SPEC NO. S18-A000-0288
HP 1.0 AMPS 9.5 VOLTS 230 DESIGN L
FRAME SIZE 180TY RPM 1150 HZ 60 AMB 40 SF 1.15
D.E. BRG. 50BC02JPP30A PH 1 DUTY * INSUL F
O.D.E. BRG. 25BC02JPG30A TYPE CS ENCL TENV CODE K
POWER FACTOR NEMA-NOM-EFF
MAX CORR KVAR GUARANTEED EFFICIENCY
NEMA NOM/CSA QUOTED EFF @ 100% LOAD
SER.NO. MOTOR WEIGHT LBS.
FINAL CONN VOLTAGE = 230 *15 MIN IN AIR ;SUB. IN SEWAGE / WATER ONLY MAXDEPTH IN MANUAL
Loading...