Autonics SCM Series Catalog Page

SCM Series
Communication Converter
The SCM series communication converters are available in various types, to o󰀨er easy signal conversion and exibility for building diverse systems. Wireless, USB-RS485, RS232C-RS485, and USB-Serial are available.
SCM-WF48 SCM-38I SCM-US48I SCM-US
Wi-Fi/RS485·USB wireless
communication converter
RS232C/RS485
communication converter
communication converter
USB/Serial
communication converter
Example of Configuration
Wi-Fi USB/RS232C/Wi-Fi
Autonics and KONICS products which support the PC loader port
DAQMaster
SCM Series
Communication converter
RS485/Serial
X-40
SCM-WF48
SCM-WF48 (Wi-Fi/RS485, USB wireless communication converter)
Features
Converting USB or RS485 signal to Wi-Fi signal and wireless
communication up to max. 100m
Compact size (W48×H25.6×L76.3mm, except antenna) Built-in surge protection circuit, reverse polarity protection circuit
Supports AP mode and station mode
Various mounting methods (DIN rail, panel)
Please read “Safety Considerations” in the instruction manual before using.
Specifications
Standard specifications
Model Power supply 24VDC
Allowable voltage range 12-28VDC
Power consumption Approx. 3W Communication type RS485, USB, Wi-Fi Isolation resistance Protection circuit Reverse polarity protection circuit, surge protection circuit
Dielectric strength 1,000VAC 50/60Hz for 1 min (between external terminal and case)
Noise resistance Vibration 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours Shock 500m/s2 (approx. 50G) in each X, Y, Z direction for 3 times
Environ
-ment
Ambient temp. -10 to 55℃, storage: -20 to 60
Ambient humi. 35 to 80%RH, storage: 35 to 80%RH Protection IP20 (IEC standard) Mounting DIN rail or panel mounting
Accessories USB 2.0 Mini B type cable (length: 1m): 1 , Connector for RS-485 (4-pin, male type): 1 Approval
1
Weight
The weight is with packaging and the weight in parentheses is only unit weight.
1:
Environment resistance is rated at no freezing or condensation.
RS-485 communication specifications
Connection RS-485 Standard EIA RS-485 Communication method 2-wire half duplex
Synchronous method Asynchronous
E󰀨ective comm. distance Max. 800m
Communication speed
Data bit
Stop bit Parity bit
1
1
1
Multi-drop Max. 31 multi-drop Connection type 4-wire screw terminal (2-wire communication method)
1: You can set communication speed and stop bit, parity bit by DAQMaster.
Wi-Fi communication specifications
Protocol TCP/IP (IPv4) Standard 802.11b/g/n (IEEE 802.11b) compatible
Comm. speed Max. 11Mbps Freq. range 2.4 to 2.497GHz
Security WEP, WPA, WPA2-PSK, Enterprise Antenna 2dBi external antenna
Comm. distance Max. 100m
SCM-WF48
Min. 200MΩ (at 500VDC megger between external terminal and case)
±500V the square wave noise (pulse width: 1㎲) by the noise simulator
Approx. 160g (approx. 57g)
1
4800, 9600 (default), 19200, 38400, 57600, 115200bps 5-bit, 6-bit, 7-bit, 8-bit (default) 1-bit (default), 2-bit None (default), Even, Odd
USB communication specifications
Power 5V, 500mA Standard USB 2.0 (compatible sub-transmission)
Comm. method 2-wire half duplex Connections USB 2.0 Mini B type (male) Comm. distance Max. 1m ± 30%
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
X-41
SCM-WF48
Part Description
SCM-WF48
1
3
1. Wi-Fi antenna
: Antenna for transmitting and receiving Wi-Fi
communication data. It may be broken when excessive pressure is applied.
2. Fixing screw hole
3. Rail Lock
4. Communication method switch
: Switch for select communication method.
2
5
6
7
4
8
USB
5. Terminating resistance switch
: Switch for whether using terminating resistance
(120Ω, 1% (F) grade chip resistance, 1/4W). (only when selecting RS485 communication method.)
RT
6. Indicator
Mode State
Green ON Power ON / AP ready Power ON
Red ON
OFF No power
7. RS485 connector
8. USB connector
: Used for fixing this unit at DIN rail mounting.
: Indicator for statue of AP mode and Station mode.
: Used for mounting the unit on a panel.
RS485
(default)
OFF
(default)
AP mode Station mode
Station or device connection is complete
: Used for connecting RS485
: Used for connecting a PC, etc.
with an USB cable.
For setting SCM-WF48 via
※
DAQMaster, set USB.
RT: Uses terminating resistances. OFF: Not use terminating
resistance.
AP connection is complete
communication cable.
Comprehensive Device Management Program (DAQMaster)
DAQMaster is the comprehensive device management program.
Set the communication method switch of SCM-WF48 as USB, and connect this unit and a PC with USB cable. You can set the communication setting for SCM-WF48 by DAQMaster.
Visit our website (www.autonics.com) and download DAQMaster.
< DAQMaster screen >< Computer specication for using software >
Item Minimum requirements
System
Operating system
Memory 256MB or more Hard disk More than 1GB of free hard disk space VGA 1024×768 or higher resolution display Others RS-232 serial port (9-pin), USB port
X-42
IBM PC compatible computer with Intel Pentium
or above
Microsoft Windows 98/NT/XP/Vista/7/8/10
Wireless Communication Converter
Example of Connections
When wiring the RS485 connector, use AWG 24 cable and tighten the connector screw with a tightening torque of
0.22 to 0.4N.m with the screwdriver for M2 screw.
Cable connections
USB 2.0
A type (male)
USB 2.0 Mini B type (male)
A BVG
+RS485
-RS485
Ground 24VDC
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
Computer
Connection of SCM-WF48 and Multi-drop
B(-)
ON OFF
A(+)
GND
V(24VDC)
SCM-WF48
A(+) B(-) A(+) B(-) A(+) B(-)
RS485
DEVICE
AP mode
#1
Wi-Fi or USB connection
Computer
SCM-WF48
Station mode
Wi-Fi or USB connection
SCM-WF48
Terminating resistance (120Ω)
RS485
DEVICE
#2
RS485
Wi-Fi
Connectable max. 31 units of
Autonics products which support
communication
...
RS485
RS485
DEVICE
#30
B(-)
RS485
DEVICE
#31
A(+)
Connectable max. 31 units of
Autonics products which support
communication
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
Computer
One wireless router can connect
max. up to 254 units of SCM-WF48.
Wireless router
Wi-Fi
SCM-WF48
RS485
Connectable max. 31 units of
Autonics products which support
communication
SCM-WF48
Before using this unit, set the communication method switch of SCM-WF48 as USB, and connect this unit and a PC with USB cable. You can set the communication setting for SCM-WF48 by DAQMaster.
X-43
(V) HMIs
(W) Panel PC
(X) Field Network Devices
SCM-WF48
Dimensions
108.5
76.3
(unit: mm)
● Panel cut-out
41.52-Ø3.5
2-M3 TAP
93.4
Installations
39
45
35mm DIN rail
Fixing
screw hole
Mounting to and removing from DIN rail
Mounting
1) Hang up the backside holder on a DIN rail.
2) Press the unit toward ① direction until it snaps.
Removing
1) Pull rail locks of the backside of this unit to ②direction.
2) Pull the unit to ③ direction.
39
25.6
Rail Lock DIN rail
Mounting to panel
1) This unit is able to mount on a panel with two fixing screws at center of both sides.
2) For mounting the unit, use M3 screws. Tighten screws with 0.4N.m torque
X-44
Wireless Communication Converter
Driver Installation
USB Driver Installation
It describes based on Windows 7 operating system. Installation method may be di󰀨erent by operating system of PC.
6) 'License Agreement' dialog box appears. Select 'I accept this agreement' and click Next .
SENSORS
CONTROLLERS
When PC is connected INTERNET and the unit is connected with PC via USB port, PC searches and installs
the driver automatically. If auto driver installation is fail, follow the below order to install the driver.
1) Visit our website (www.autonics.com) and download 'SCM-WF48 Driver'.
2) Unzip the downloaded file at the desired directory.
3) Connect the unit at USB port of the PC and run CDM21216_Setup.exe at the directory.
4) 'FTDI CDM Drivers' dialog box appears. Click 'Extract'. Files are extracted.
5) Device Driver Installation Wizard dialog box appears. Click 'Next'.
7) Driver installation is completed.
After installing the driver, you can check the driver installation at Device Manager.
Enter [Start]-[Control Panel]-[Device Manager] and extend Ports (COM & LPT) and USB Serial Port (COM4) to check SCM-WF48 connection.
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
If USB port is changed, reinstall the USB driver.
X-45
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
SCM-38I
SCM-38I (RS232C to RS485 communication converter)
Features
● Built-in surge protection circuit
● The insulation type of signal line
(insulating RS232C and RS485)
● Create Tx-Enable signal automatically
Please read “Safety Considerations” in the instruction manual before using.
Specifications
Model Power supply 12-24VDCᜡ±10% Power consumption Approx. 1.7W Max. comm. speed Communication type Half duplex type Available comm. distance Max. 1.2km Multi-drop Max. 31 multi-drop
Protocol
Connection type
Isolation type Isolation
Dielectric strength
Insulation resistance Min. 100MΩ (at 500VDC megger) Noise strength ±500V the square wave noise (pulse width: 1) by the noise simulator
Vibration
Shock
Environ­ment
Approval
Weight
When communicating with Autonics products, set communication speed to 9,600bps.
※ ※ ※
1
2
1: Protocol and communication speed are set by Hyper terminal. DAQMaster, ParaSet, Modbus Poll.
2: The weight includes packaging. The weight in parenthesis is for unit only. There might be some di󰀨erences in the specication above depending on PC environment. Environment resistance is rated at no freezing or condensation.
Data bit 5-bit, 6-bit, 7-bit, 8-bit
Stop bit 1-bit, 2-bit Parity bit None, Even, Odd
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 min
Mechanical 300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction 100m/s2 (approx. 10G) in each X, Y, Z direction for 3 times Ambient temp. -10 to 55℃,storage:-20to60℃ Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
SCM-38I
1
1,200 to 115,200bps (recommended: 9,600bps)
RS232: D-sub 9-pin RS485: 4-wire screw terminal (2-wire communication type)
● Between terminals and case: 2500VAC 50/60Hz for 1 min
● Between RS232C and RS485: 2500VAC 50/60Hz for 1 min
Approx. 106g (approx. 46g)
Installations
Multi-layer
'B' (Length of screw)
X-46
M3 screw bolt
'A' (Height of layer)
Panel
Number of layers (N)
1 23.5mm 20mm
2 46.5mm 43mm
3 69.5mm 66mm
4 92.5mm 89mm
"A" size
(23N+0.5)
"B" size
(23N-3)
RS232C to RS485 Communication Converter
Example of Connections
When wiring the RS485 connector, use AWG 24 cable and tighten the connector screw with a tightening torque of 0.22 to 0.4N.m with the screwdriver for M2 screw.
SENSORS
A B V G
● Terminating resistance selection
G: GROUND
V: 12-24VDC input
B (-)
RS485 signal line
A (+)
Multi-drop connection method with PC
ON: Using terminating resistance OFF: Not using terminating resistance
GND
RXD-RXD
RS232C RS485
VCC
(12-24VDC)
Terminating
resistance
(100 to 120Ω)
TXD-TXD
GND-GND
Computer
RS232C Cable
B (-)
ON OFF
A (+) B (-)
RS485
DEVICE
#1
A (+) B (-) A (+) B (-)
RS485
DEVICE
#2
...
RS485
DEVICE
#30
A (+)
● RS232C
When the software of the communication driver uses Auto-loop Back, please connect as the above.
cable connection
Computer Computer
DCD
DSR RXD
RTS
TXD
CTS
DTR
GND
RI
<Standard connection> <Using Auto-loop Back>
SCM-38I SCM-38I
DCD DSR RXD
RTS
TXD
CTS
DTR
GND
RI
Dimensions
81.7
2-Ø3.3
75.5
38
25.6
38.8
● Panel cut-out
ON OFF
2-M3 TAP
25.6
B (-)
A (+)
RS485
DEVICE
#31
(unit: mm)
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
7.88.6
23.2
X-47
(X) Field Network Devices
SCM-US48I
SCM-US48I (USB to RS485 communication converter)
Features
● Available to transmit signals to max. 1.2km by
converting USB signal to RS485 signal
● Realizing electrical insulation (2500VRMS) between
USB port and RS485 port through RS485 transceiver.
● Improved stability and durability with built-in protection circuit
● Easy connections between devices with bus power supplied
from USB host controller without external power supply
● Offering USB 2.0 A/B type cable with built-in ferrite core
for noise reduction
● Various operating systems supported
(Windows 98, 98SE, ME, 2000, Server 2003, XP, Vista, 7)
● User friendly features through compatibility with USB 1.1 and USB 2.0
Please read “Safety Considerations” in the instruction manual before using.
Specifications
Model
Power supply 5VDCᜡ USB bus power
Power consumption Approx. 1W
Max. comm. speed
Communication type Half duplex type
Available comm. distance
Multi-drop Max. 31 multi-drop
Data bit 5-bit, 6-bit, 7-bit, 8-bit
2
Protocol
Connection type
Isolation type Isolation
Dielectric strength
Insulation resistance Min. 100MΩ (at 500VDC megger) Noise strength ±500V the square wave noise (pulse width: 1) by the noise simulator
Vibration
Shock
Environ­ment
Approval Accessory USB 2.0 AB type connector (length: 1m)
Weight
※ ※
When communicating with Autonics products, set communication speed to 9,600bps.
※ ※ ※
Stop bit 1-bit, 2-bit
Parity bit None, Even, Odd
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 min
Mechanical 300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction 100m/s2 (approx. 10G) in each X, Y, Z direction for 3 times Ambient temp. -10 to 55℃,storage:-20to60℃ Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
3
1: USB bus power is supplied from PC or USB host controller. 2: Protocol and communication speed are set by Hyper terminal. DAQMaster, ParaSet, Modbus Poll.
3: The weight includes packaging. The weight in parenthesis is for unit only. There might be some di󰀨erences in the specication above depending on PC environment. Environment resistance is rated at no freezing or condensation.
SCM-US48I
2
1,200 to 115,200bps (recommended: 9,600bps)
USB: max. 1m ± 30% RS485: max.1.2km
USB: USB 2.0 B type (male) RS485: 4-wire screw terminal (2-wire communication type)
● Between terminals and case: 2000VAC 50/60Hz for 1 min
● Between USB and RS485: 2500VAC 50/60Hz for 1 min
Approx. 197g (approx. 34.5g)
1
X-48
Installations
Multi-layer
USB to RS485 Communication Converter
M3 screw bolt
SENSORS
Number of layers (N)
"A" size
(23N+0.5)
1 23.5mm 20mm
2 46.5mm 43mm
3 69.5mm 66mm
4 92.5mm 89mm
'B' (Length of screw)
'A' (Height of layer)
Panel
Example of Connections
When wiring the RS485 connector, use AWG 24 cable and tighten the connector screw with a tightening torque of 0.22 to 0.4N.m with the screwdriver for M2 screw.
Terminating
resistance
(100 to 120Ω)
RS485
DEVICE
#2
RS485
DEVICE
#30
Computer
USB 2.0
B type (male)
USB RS485
B (-)
ON OFF
A (+)
A (+) B (-) A (+) B (-) A (+) B (-)
RS485
DEVICE
#1
Dimensions
2-Ø3.3
75.5
38
● Panel cut-out
2-M3 TAP
"B" size
(23N-3)
B (-)
A (+)
RS485
DEVICE
#31
(unit: mm)
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
25.6
38.8
23.2
USB 2.0 AB type cable (accessory)
USB 2.0 AB type cable is including the product and is also sold separately.
(model: USB AB CABLE)
±30
USB B
Type
±5
20
1,000
(R) Digital
25.6
USB A
±5
20
Type
Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
X-49
SCM-US48I
Driver Installation
※ This Driver Installation shows the procedure for Windows XP. There might be some differences in the specification
above depending on OS.
USB Driver Installation
1) Visit our website (www.autonics.com) to download USB
Driver.
2) Unzip the downloaded 'SCM-US48I.zip', or 'SCM-US. zip' at any directory.
3) When connecting product with USB port, 'Found New Hardware Wizard' will appear automatically. 'Do you want to search software by connecting 'Window Update'?. Click 'No' button and the following window will be displayed to proceed Driver installation. Select 'Install from a list or specific location' (Advanced)' (S) and click 'Next'.
6) Hardware installation message will appear while Found New Hardware Wizard is running. Click 'Continue Anyway' to proceed with installation.
7) The following window will be displayed if the USB Driver is installed properly. Click the 'Finish' button.
4)Select 'Search for best driver in these locations' and 'include this location in the search' continuously. Click the 'Browse' button.
5)When 'Browse Folder' window is displayed, select 'SCM­US\Driver' for SCM-US48I, SCM-US, and click 'Finish'. Click 'Next' to proceed with the USB Driver installation.
If USB port is changed, reinstall the USB driver.
X-50
USB to RS485 Communication Converter
Serial Port Driver Installation
1) After installing USB Driver, Serial Port (COM port),
'Found New Hardware Wizard' will appear (Serial
Port Driver installation follows the same procedures described in installing USB Driver).
2) After selecting 'Install from a list or specific location (advance)', click 'Next' button. The following window will be displayed for 'Search and installation options'
3) Because a driver location was selected when installing USB driver, click 'Next' button.
Verify that drivers were installed properly with the windows Device Manager after finishing USB Driver and Serial Port Driver installation. Open the folder [My computer], open the system folder (click right), click the hardware tab, and click the Device Manager Button. Then, make sure that 'SCM-US48I Driver (Autonics Corp)' or 'SCM-US Driver (Autonics Corp)' is found in 'Common Serial Bus Controller' category and 'Port (COM and LPT) is found in 'SCM­US48I Serial Port (COM ) or 'SCM-US Serial Port (COM
)'.
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
4)Hardware installation message will appear while Found New Hardware Wizard is running. Click 'Continue Anyway' to proceed with installation.
5)'Completing the Found New Hardware wizard' will be displayed if the Serial Port Driver is installed properly. Click the 'Finish' button.
This Driver Installation is described based on the procedure for Windows XP. There might be some differences in the specification above depending on OS.
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
X-51
(X) Field Network Devices
SCM-US
SCM-US (USB to Serial communication converter)
Features
● Applicable OS: Windows 98, 98SE, ME, 2000,
Server 2003, XP, Vista, 7
● Both USB 1.1 and USB 2.0 compatible
● Data transmission / power supply indicating LED
● Easy to connect with PC
Some products requires the dedicated converter cable
(EXT-US, sold separately)
● Built-in protection circuit
● Ferrite core cable for noise reduction
● Non-isolation type
Specifically designed to connect to particular Autonics and
Konics products which support the PC loader port.
Please read “Safety Considerations” in the instruction manual before using.
Specifications
Model
Power supply 5VDCᜡ USB bus power
Power consumption Approx. 1W
Max. comm. speed
Communication type Half duplex type Available comm. distance 1.5m (not extension)
Connection type
Isolation type Non-isolation
Vibration
Shock
Environ
-ment
Approval
Weight
※ ※
When communicating with Autonics products, set communication speed to 9,600bps.
※ ※ ※ ※
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour Malfunction 0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 min
Mechanical 300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction 100m/s2 (approx. 10G) in each X, Y, Z direction for 3 times Ambient temp. -10 to 55℃,storage:-20to60℃ Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
4
1: USB bus power is supplied from PC or USB host controller. 2: Protocol and communication speed are set by Hyper terminal. DAQMaster, ParaSet, Modbus Poll.
3: Some products requires the EXT-US(converter cable, sold separately). 4: The weight includes packaging. The weight in parenthesis is for unit only. There might be some di󰀨erences in the specication above depending on PC environment. Environment resistance is rated at no freezing or condensation.
SCM-US
2
1,200 to 115,200bps (recommended: 9,600bps)
USB: USB 2.0 A type (male) Earphone jack (4 pole stereo phone plug)
Approx. 80g (approx. 41g)
1
3
X-52
USB to Serial Communication Converter
Example of Connections
※UseonlyforAutonicsproductsthatsupportSCM-US.
1: Some products requires the dedicated converter cable(EXT-US, sold separately) to connect SCM-US. Do not apply
excessive force to the converter cable. It may cause damage to the unit. Do not bend cable and connector part. It may cause damage to the unit.
EXT-US (converter cable, sold separately)
1
SENSORS
CONTROLLERS
MOTION DEVICES
USB 2.0
A type (male)
USB
Computer
Dimensions
8
4.5
52
40.3
12
18
A.C.C (green LED) : Rx/Tx Data Transmission
O.P.R (red LED)
: Power
EXT-US (converter cable, sold separately)
8.8
8
Serial
1500
200
Autonics products which
support the PC loader port
(unit: mm)
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
23.5
19.7
4.9
Driver Installation
The USB driver installation and serial port driver installation are same as SCM-US48I. Refer to '
SCM-US48I Series
in '
'.
Ø11.5
Driver Installations
'
X-53
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
SCM Series
Proper Usage (SCM Series common)
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 12-24VDC or 24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply
device.
3. Use only designated connector and do not apply excessive power when connecting or disconnecting the connectors.
4. Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal
line closely, use line lter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise.
5. Do not connect or disconnect the USB cable, earphone jack, or RS485 cable quickly and repeatedly while
communicating. It may cause damage or malfunction of the product and PC.
6. After supplying power, connect with the communication output product. When disconnect, communication output product
rst and power last.
7. When connecting multiple SCM-US48I, SCM-US or SCM-WF48 units to a PC, number of COM port goes up in
sequential order and it takes some time to identify and assign number of COM port.
8. When connecting the RS485 communication output product, connect the terminating resistance (SCM-38I, SCM-US48I,
SCM-US: 100 to 120Ω, SCM-WF48: 120Ω) at each end of the communication cable.
9. Use twist pair wire for RS485 communication. If not, use A(+) and B(-) cables in the same length.
10. Use USB cable of designated standard, and do not use extension cable.
11. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specications')
Altitude max. 2,000m
Pollution degree 2
Installation category I
X-54
Loading...