The SCM series communication converters are available in various types, to oer easy signal conversion and
exibility for building diverse systems. Wireless, USB-RS485, RS232C-RS485, and USB-Serial are available.
SCM-WF48SCM-38ISCM-US48ISCM-US
Wi-Fi/RS485·USB wireless
communication converter
RS232C/RS485
communication converter
USB/RS485
communication converter
USB/Serial
communication converter
Example of Configuration
Wi-FiUSB/RS232C/Wi-Fi
Autonics and KONICS products which support the PC loader port
DAQMaster
SCM Series
Communication converter
RS485/Serial
X-40
SCM-WF48
SCM-WF48
(Wi-Fi/RS485, USB wireless communication converter)
Features
Converting USB or RS485 signal to Wi-Fi signal and wireless
Please read “Safety Considerations”
in the instruction manual before using.
Specifications
Standard specifications
Model
Power supply24VDC
Allowable voltage range12-28VDC
Power consumptionApprox. 3W
Communication typeRS485, USB, Wi-Fi
Isolation resistance
Protection circuitReverse polarity protection circuit, surge protection circuit
Dielectric strength1,000VAC 50/60Hz for 1 min (between external terminal and case)
Noise resistance
Vibration1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock500m/s2 (approx. 50G) in each X, Y, Z direction for 3 times
Environ
-ment
Ambient temp. -10 to 55℃, storage: -20 to 60
Ambient humi. 35 to 80%RH, storage: 35 to 80%RH
ProtectionIP20 (IEC standard)
MountingDIN rail or panel mounting
AccessoriesUSB 2.0 Mini B type cable (length: 1m): 1 , Connector for RS-485 (4-pin, male type): 1
Approval
※
1
Weight
※
The weight is with packaging and the weight in parentheses is only unit weight.
1:
※
Environment resistance is rated at no freezing or condensation.
RS-485 communication specifications
ConnectionRS-485
StandardEIA RS-485
Communication method2-wire half duplex
Synchronous methodAsynchronous
Eective comm. distance Max. 800m
Communication speed
※
Data bit
Stop bit
Parity bit
1
※
1
※
1
Multi-dropMax. 31 multi-drop
Connection type4-wire screw terminal (2-wire communication method)
※
1: You can set communication speed and stop bit, parity bit by DAQMaster.
Comm. method 2-wire half duplex
ConnectionsUSB 2.0 Mini B type (male)
Comm. distance Max. 1m ± 30%
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
X-41
SCM-WF48
Part Description
SCM-WF48
1
3
1. Wi-Fi antenna
: Antenna for transmitting and receiving Wi-Fi
communication data.
It may be broken when excessive pressure is applied.
2. Fixing screw hole
3. Rail Lock
4. Communication method switch
: Switch for select communication method.
2
5
6
7
4
8
USB
5. Terminating resistance switch
: Switch for whether using terminating resistance
(120Ω, 1% (F) grade chip resistance, 1/4W).
(only when selecting RS485 communication method.)
RT
6. Indicator
Mode
State
Green ONPower ON / AP readyPower ON
Red ON
OFFNo power
7. RS485 connector
8. USB connector
: Used for fixing this unit at DIN rail mounting.
: Indicator for statue of AP mode and Station mode.
: Used for mounting the unit on a panel.
RS485
(default)
OFF
(default)
AP modeStation mode
Station or device
connection is complete
: Used for connecting RS485
: Used for connecting a PC, etc.
with an USB cable.
For setting SCM-WF48 via
※
DAQMaster, set USB.
RT: Uses terminating resistances.
OFF: Not use terminating
resistance.
AP connection is
complete
communication cable.
Comprehensive Device Management Program (DAQMaster)
DAQMaster is the comprehensive device management program.
Set the communication method switch of SCM-WF48 as USB, and connect this unit and a PC with USB cable.
You can set the communication setting for SCM-WF48 by DAQMaster.
Visit our website (www.autonics.com) and download DAQMaster.
< DAQMaster screen >< Computer specication for using software >
ItemMinimum requirements
System
Operating
system
Memory256MB or more
Hard diskMore than 1GB of free hard disk space
VGA1024×768 or higher resolution display
OthersRS-232 serial port (9-pin), USB port
X-42
IBM PC compatible computer with Intel Pentium
Ⅲ
or above
Microsoft Windows 98/NT/XP/Vista/7/8/10
Wireless Communication Converter
Example of Connections
※
When wiring the RS485 connector, use AWG 24 cable and tighten the connector screw with a tightening torque of
0.22 to 0.4N.m with the screwdriver for M2 screw.
Cable connections
USB 2.0
A type (male)
USB 2.0 Mini
B type (male)
A BVG
+RS485
-RS485
Ground
24VDC
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
Computer
Connection of SCM-WF48 and Multi-drop
B(-)
ONOFF
A(+)
GND
V(24VDC)
SCM-WF48
A(+) B(-) A(+) B(-) A(+) B(-)
RS485
DEVICE
AP mode
#1
Wi-Fi or
USB connection
Computer
SCM-WF48
Station mode
Wi-Fi or
USB connection
SCM-WF48
Terminating resistance (120Ω)
RS485
DEVICE
#2
RS485
Wi-Fi
Connectable max. 31 units of
Autonics products which support
communication
...
RS485
RS485
DEVICE
#30
B(-)
RS485
DEVICE
#31
A(+)
Connectable max. 31 units of
Autonics products which support
communication
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
Computer
※
One wireless router can connect
max. up to 254 units of SCM-WF48.
Wireless router
Wi-Fi
SCM-WF48
RS485
Connectable max. 31 units of
Autonics products which support
communication
SCM-WF48
※
Before using this unit, set the communication method switch of SCM-WF48 as USB, and connect this unit and a PC
with USB cable. You can set the communication setting for SCM-WF48 by DAQMaster.
X-43
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
SCM-WF48
Dimensions
108.5
76.3
(unit: mm)
● Panel cut-out
41.52-Ø3.5
2-M3 TAP
93.4
Installations
②
39
45
35mm DIN rail
③
Fixing
screw hole
Mounting to and removing from DIN rail
Mounting
1) Hang up the backside holder on a DIN rail.
2) Press the unit toward ① direction until it snaps.
Removing
1) Pull rail locks of the backside of this unit to ②direction.
2) Pull the unit to ③ direction.
39
25.6
①
Rail LockDIN rail
Mounting to panel
1) This unit is able to mount on a panel with two fixing screws at center of both sides.
2) For mounting the unit, use M3 screws. Tighten screws with 0.4N.m torque
X-44
Wireless Communication Converter
Driver Installation
USB Driver Installation
※
It describes based on Windows 7 operating system.
Installation method may be dierent by operating system
of PC.
6) 'License Agreement' dialog box appears. Select
'I accept this agreement' and click Next .
SENSORS
CONTROLLERS
When PC is connected INTERNET and the unit is
connected with PC via USB port, PC searches and installs
the driver automatically.
If auto driver installation is fail, follow the below order to
install the driver.
1) Visit our website (www.autonics.com) and download
'SCM-WF48 Driver'.
2) Unzip the downloaded file at the desired directory.
3) Connect the unit at USB port of the PC and run
CDM21216_Setup.exe at the directory.
After installing the driver, you can check the driver
installation at Device Manager.
Enter [Start]-[Control Panel]-[Device Manager] and
extend Ports (COM & LPT) and USB Serial Port (COM4)
to check SCM-WF48 connection.
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
※
If USB port is changed, reinstall the USB driver.
X-45
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
SCM-38I
SCM-38I (RS232C to RS485 communication converter)
Features
● Built-in surge protection circuit
● The insulation type of signal line
(insulating RS232C and RS485)
● Create Tx-Enable signal automatically
Please read “Safety Considerations”
in the instruction manual before using.
Specifications
Model
Power supply12-24VDCᜡ±10%
Power consumptionApprox. 1.7WMax. comm. speed
Communication typeHalf duplex typeAvailable comm. distance Max. 1.2km
Multi-dropMax. 31 multi-drop
※
Protocol
Connection type
Isolation typeIsolation
Dielectric strength
Insulation resistanceMin. 100MΩ (at 500VDC megger)
Noise strength±500V the square wave noise (pulse width: 1㎲) by the noise simulator
Vibration
Shock
Environment
Approval
Weight
※
When communicating with Autonics products, set communication speed to 9,600bps.
※
※
※
1
※
2
1: Protocol and communication speed are set by Hyper terminal. DAQMaster, ParaSet, Modbus Poll.
2: The weight includes packaging. The weight in parenthesis is for unit only.
There might be some dierences in the specication above depending on PC environment.
Environment resistance is rated at no freezing or condensation.
※
Data bit5-bit, 6-bit, 7-bit, 8-bit
Stop bit1-bit, 2-bit
Parity bitNone, Even, Odd
Mechanical0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour
Malfunction0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 min
Mechanical300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction100m/s2 (approx. 10G) in each X, Y, Z direction for 3 times
Ambient temp. -10 to 55℃,storage:-20to60℃
Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
SCM-38I
1
1,200 to 115,200bps (recommended: 9,600bps)
RS232: D-sub 9-pin
RS485: 4-wire screw terminal (2-wire communication type)
● Between terminals and case: 2500VAC 50/60Hz for 1 min
● Between RS232C and RS485: 2500VAC 50/60Hz for 1 min
Approx. 106g (approx. 46g)
Installations
Multi-layer
'B' (Length of screw)
X-46
M3 screw bolt
'A' (Height of layer)
Panel
Number of layers
(N)
123.5mm20mm
246.5mm43mm
369.5mm66mm
492.5mm89mm
"A" size
(23N+0.5)
"B" size
(23N-3)
RS232C to RS485 Communication Converter
Example of Connections
※
When wiring the RS485 connector, use AWG 24 cable and
tighten the connector screw with a tightening torque of 0.22 to 0.4N.m with the screwdriver for M2 screw.
SENSORS
A B V G
● Terminating resistance selection
G: GROUND
V: 12-24VDC input
B (-)
RS485 signal line
A (+)
●
Multi-drop connection method with PC
ON: Using terminating resistance
OFF: Not using terminating resistance
GND
RXD-RXD
RS232CRS485
VCC
(12-24VDC)
Terminating
resistance
(100 to 120Ω)
TXD-TXD
GND-GND
Computer
RS232C Cable
B (-)
ONOFF
A (+) B (-)
RS485
DEVICE
#1
A (+) B (-)A (+) B (-)
RS485
DEVICE
#2
...
RS485
DEVICE
#30
A (+)
● RS232C
※
When the software of the communication driver uses Auto-loop Back, please connect as the above.
cable connection
ComputerComputer
DCD
①
DSR
RXD
RTS
TXD
CTS
DTR
GND
RI
⑥
②
⑦
③
⑧
④
⑨
⑤
<Standard connection><Using Auto-loop Back>
SCM-38ISCM-38I
①
⑥
②
⑦
③
⑧
④
⑨
⑤
DCD
DSR
RXD
RTS
TXD
CTS
DTR
GND
RI
①
⑥
②
⑦
③
⑧
④
⑨
⑤
Dimensions
81.7
2-Ø3.3
75.5
38
25.6
38.8
● Panel cut-out
ONOFF
2-M3 TAP
25.6
B (-)
A (+)
⑥
⑦
⑧
⑨
RS485
DEVICE
#31
①
②
③
④
⑤
(unit: mm)
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
7.88.6
23.2
X-47
(X)
Field Network
Devices
SCM-US48I
SCM-US48I (USB to RS485 communication converter)
Features
● Available to transmit signals to max. 1.2km by
converting USB signal to RS485 signal
● Realizing electrical insulation (2500VRMS) between
USB port and RS485 port through RS485 transceiver.
● Improved stability and durability with built-in protection circuit
● Easy connections between devices with bus power supplied
from USB host controller without external power supply
● Offering USB 2.0 A/B type cable with built-in ferrite core
for noise reduction
● Various operating systems supported
(Windows 98, 98SE, ME, 2000, Server 2003, XP, Vista, 7)
● User friendly features through compatibility with USB 1.1 and USB 2.0
Please read “Safety Considerations”
in the instruction manual before using.
Specifications
Model
Power supply5VDCᜡ USB bus power
Power consumptionApprox. 1W
Max. comm. speed
Communication typeHalf duplex type
Available comm. distance
Multi-dropMax. 31 multi-drop
Data bit5-bit, 6-bit, 7-bit, 8-bit
※
2
Protocol
Connection type
Isolation typeIsolation
Dielectric strength
Insulation resistanceMin. 100MΩ (at 500VDC megger)
Noise strength±500V the square wave noise (pulse width: 1㎲) by the noise simulator
Vibration
Shock
Environment
Approval
AccessoryUSB 2.0 AB type connector (length: 1m)
Weight
※
※
When communicating with Autonics products, set communication speed to 9,600bps.
※
※
※
Stop bit1-bit, 2-bit
Parity bitNone, Even, Odd
Mechanical0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour
Malfunction0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 min
Mechanical300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction100m/s2 (approx. 10G) in each X, Y, Z direction for 3 times
Ambient temp.-10 to 55℃,storage:-20to60℃
Ambient humi.35 to 85%RH, storage: 35 to 85%RH
※
3
1: USB bus power is supplied from PC or USB host controller.
2: Protocol and communication speed are set by Hyper terminal. DAQMaster, ParaSet, Modbus Poll.
3: The weight includes packaging. The weight in parenthesis is for unit only.
There might be some dierences in the specication above depending on PC environment.
Environment resistance is rated at no freezing or condensation.
※
SCM-US48I
2
1,200 to 115,200bps (recommended: 9,600bps)
USB: max. 1m ± 30%
RS485: max.1.2km
USB: USB 2.0 B type (male)
RS485: 4-wire screw terminal (2-wire communication type)
● Between terminals and case: 2000VAC 50/60Hz for 1 min
● Between USB and RS485: 2500VAC 50/60Hz for 1 min
Approx. 197g (approx. 34.5g)
※
1
X-48
Installations
Multi-layer
USB to RS485 Communication Converter
M3 screw bolt
SENSORS
Number of layers
(N)
"A" size
(23N+0.5)
123.5mm20mm
246.5mm43mm
369.5mm66mm
492.5mm89mm
'B' (Length of screw)
'A' (Height of layer)
Panel
Example of Connections
※
When wiring the RS485 connector, use AWG 24 cable and
tighten the connector screw with a tightening torque of 0.22 to 0.4N.m with the screwdriver for M2 screw.
Terminating
resistance
(100 to 120Ω)
RS485
DEVICE
#2
RS485
DEVICE
#30
Computer
USB 2.0
B type (male)
USBRS485
B (-)
ONOFF
A (+)
A (+) B (-)A (+) B (-)A (+) B (-)
RS485
DEVICE
#1
Dimensions
2-Ø3.3
75.5
38
● Panel cut-out
2-M3 TAP
"B" size
(23N-3)
B (-)
A (+)
RS485
DEVICE
#31
(unit: mm)
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
25.6
38.8
23.2
USB 2.0 AB type cable (accessory)
※
USB 2.0 AB type cable is including the product and is also sold separately.
(model: USB AB CABLE)
±30
USB B
Type
±5
20
1,000
(R)
Digital
25.6
USB A
±5
20
Type
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
X-49
SCM-US48I
Driver Installation
※ This Driver Installation shows the procedure for Windows XP. There might be some differences in the specification
above depending on OS.
USB Driver Installation
1) Visit our website (www.autonics.com) to download USB
Driver.
2) Unzip the downloaded 'SCM-US48I.zip', or 'SCM-US.
zip' at any directory.
3) When connecting product with USB port, 'Found
New Hardware Wizard' will appear automatically. 'Do
you want to search software by connecting 'Window
Update'?. Click 'No' button and the following window will
be displayed to proceed Driver installation.
Select 'Install from a list or specific location' (Advanced)'
(S) and click 'Next'.
6) Hardware installation message will appear while Found
New Hardware Wizard is running. Click 'Continue
Anyway' to proceed with installation.
7) The following window will be displayed if the USB Driver
is installed properly. Click the 'Finish' button.
4)Select 'Search for best driver in these locations' and
'include this location in the search' continuously.
Click the 'Browse' button.
5)When 'Browse Folder' window is displayed, select 'SCMUS\Driver' for SCM-US48I, SCM-US, and click 'Finish'.
Click 'Next' to proceed with the USB Driver installation.
※
If USB port is changed, reinstall the USB driver.
X-50
USB to RS485 Communication Converter
Serial Port Driver Installation
1) After installing USB Driver, Serial Port (COM port),
'Found New Hardware Wizard' will appear (Serial
Port Driver installation follows the same procedures
described in installing USB Driver).
2) After selecting 'Install from a list or specific location
(advance)', click 'Next' button. The following window will
be displayed for 'Search and installation options'
3) Because a driver location was selected when installing
USB driver, click 'Next' button.
※
Verify that drivers were installed properly with the
windows Device Manager after finishing USB Driver and
Serial Port Driver installation.
Open the folder [My computer], open the system folder
(click right), click the hardware tab, and click the Device
Manager Button. Then, make sure that 'SCM-US48I
Driver (Autonics Corp)' or 'SCM-US Driver (Autonics
Corp)' is found in 'Common Serial Bus Controller'
category and 'Port (COM and LPT) is found in 'SCMUS48I Serial Port (COM ) or 'SCM-US Serial Port (COM
)'.
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
4)Hardware installation message will appear while Found
New Hardware Wizard is running. Click 'Continue
Anyway' to proceed with installation.
5)'Completing the Found New Hardware wizard' will be
displayed if the Serial Port Driver is installed properly.
Click the 'Finish' button.
※
This Driver Installation is described based on the
procedure for Windows XP.
There might be some differences in the specification
above depending on OS.
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
X-51
(X)
Field Network
Devices
SCM-US
SCM-US (USB to Serial communication converter)
Features
● Applicable OS: Windows 98, 98SE, ME, 2000,
Server 2003, XP, Vista, 7
● Both USB 1.1 and USB 2.0 compatible
● Data transmission / power supply indicating LED
● Easy to connect with PC
Some products requires the dedicated converter cable
(EXT-US, sold separately)
● Built-in protection circuit
● Ferrite core cable for noise reduction
● Non-isolation type
※
Specifically designed to connect to particular Autonics and
Konics products which support the PC loader port.
Please read “Safety Considerations”
in the instruction manual before using.
Specifications
Model
Power supply5VDCᜡ USB bus power
Power consumptionApprox. 1W
Max. comm. speed
Communication typeHalf duplex typeAvailable comm. distance 1.5m (not extension)
Connection type
Isolation typeNon-isolation
Vibration
Shock
Environ
-ment
Approval
Weight
※
※
When communicating with Autonics products, set communication speed to 9,600bps.
※
※
※
※
Mechanical0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour
Malfunction0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 min
Mechanical300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction100m/s2 (approx. 10G) in each X, Y, Z direction for 3 times
Ambient temp.-10 to 55℃,storage:-20to60℃
Ambient humi.35 to 85%RH, storage: 35 to 85%RH
※
4
1: USB bus power is supplied from PC or USB host controller.
2: Protocol and communication speed are set by Hyper terminal. DAQMaster, ParaSet, Modbus Poll.
3: Some products requires the EXT-US(converter cable, sold separately).
4: The weight includes packaging. The weight in parenthesis is for unit only.
There might be some dierences in the specication above depending on PC environment.
Environment resistance is rated at no freezing or condensation.
※
SCM-US
2
1,200 to 115,200bps (recommended: 9,600bps)
USB: USB 2.0 A type (male)
Earphone jack (4 pole stereo phone plug)
1: Some products requires the dedicated converter cable(EXT-US, sold separately) to connect SCM-US. Do not apply
※
excessive force to the converter cable. It may cause damage to the unit. Do not bend cable and connector part. It may
cause damage to the unit.
EXT-US
(converter cable, sold separately)
1
※
SENSORS
CONTROLLERS
MOTION DEVICES
USB 2.0
A type (male)
USB
Computer
Dimensions
8
4.5
52
40.3
12
18
A.C.C (green LED)
: Rx/Tx Data Transmission
O.P.R (red LED)
: Power
EXT-US (converter cable, sold separately)
8.8
8
Serial
1500
200
Autonics products which
support the PC loader port
(unit: mm)
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
23.5
19.7
4.9
Driver Installation
The USB driver installation and serial port driver installation are same as SCM-US48I. Refer to '
SCM-US48I Series
in '
'.
Ø11.5
Driver Installations
'
X-53
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
SCM Series
Proper Usage (SCM Series common)
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 12-24VDC or 24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply
device.
3. Use only designated connector and do not apply excessive power when connecting or disconnecting the connectors.
4. Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal
line closely, use line lter or varistor at power line and shielded wire at input signal line. Do not use near the equipment
which generates strong magnetic force or high frequency noise.
5. Do not connect or disconnect the USB cable, earphone jack, or RS485 cable quickly and repeatedly while
communicating. It may cause damage or malfunction of the product and PC.
6. After supplying power, connect with the communication output product. When disconnect, communication output product
rst and power last.
7. When connecting multiple SCM-US48I, SCM-US or SCM-WF48 units to a PC, number of COM port goes up in
sequential order and it takes some time to identify and assign number of COM port.
8. When connecting the RS485 communication output product, connect the terminating resistance (SCM-38I, SCM-US48I,
SCM-US: 100 to 120Ω, SCM-WF48: 120Ω) at each end of the communication cable.
9. Use twist pair wire for RS485 communication. If not, use A(+) and B(-) cables in the same length.
10. Use USB cable of designated standard, and do not use extension cable.
11. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specications')
①
Altitude max. 2,000m
②
Pollution degree 2
③
Installation category I
④
X-54
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.