Autonics SCM-WF48, SCM-US48I, SCM-38I, SCM-US Quick Manual

SCM Series
Communication Converter
SCM-WF48
Wi-Fi/RS485, USB wireless communication converter (converting Wi-Fi to RS485, USB)
Features
Converting USB or RS485 signal to Wi-Fi signal and wireless
communication up to max. 100m
Compact size(W48×H25.3×L76mm, excepting antenna) Built-in surge protection circuit,
reverse polarity protection circuit
Supports AP mode and infrastructure mode DIN rail and panel mounting
(pending)
SCM-US48I
USB to Serial converter(converting signal USB to Serial)
Features
● Available to transmit signals to max. 1.2km by converting USB signal to RS485 signal
● Realizing electrical insulation(2500V RMS) between USB port and RS485 port through RS485 transceiver.
● Improved stability and durability with built-in protection circuit
● Easy connections between devices with bus power supplied from USB host controller without external power supply
● Offering USB 2.0 A/B type cable with built-in ferrite core for noise reduction
● Various operating systems supported (Windows 98, 98SE, ME, 2000, Server 2003, XP, Vista, 7)
● User friendly features through compatibility with USB 1.1 and USB 2.0
SCM-38I
RS232C to RS485 converter(converting signal RS232C to RS485)
Features
● Built-in surge protection circuit
● The insulation type of signal line (Insulating RS232C and RS485)
● Create Tx-Enable signal automatically
SCM-US
USB to Serial converter(converting signal USB to Serial)
Features
● Applicable OS : Windows 98, 98SE, ME, 2000, Server 2003, XP, Vista, 7
● Both USB 1.1 and USB 2.0 compatible
● Data transmission / power supply indicating LED
● Easy to connect with PC
● Built-in protection circuit
● Ferrite core cable for noise reduction
● Non-isolation type
Please read “Caution for your safety” in operation manual before using.
(available soon)
Specifically designed to connect to particular Autonics and Konics products which support the PC loader port.
(A) Photo electric sensor
(B) Fiber optic sensor
(C) Door/Area sensor
(D) Proximity sensor
(E) Pressure sensor
(F) Rotary encoder
(G) Connector/ Socket
(H) Temp. controller
(I) SSR/ Power controller
(J) Counter
(K) Timer
(L) Panel meter
(M) Tacho/ Speed/ Pulse meter
(N) Display unit
(O) Sensor controller
(P) Switching mode power supply
(Q) Stepper motor& Driver&Controller
(R) Graphic/ Logic panel
(S) Field network device
(T) Software
(U) Other
S-31
SCM Series

Specifications

SCM-WF48
Model SCM-WF48 Power supply 24VDC Allowable voltage range 12-28VDC Communication type RS485, USB, Wi-Fi Isolation resistance Min. 200 MΩ(at 500 VDC megger between external terminal and case) Protection circuit Reverse polarity protection circuit, surge protection circuit Dielectric strength 1,000VAC 50/60Hz for 1 min.(between external terminal and case) Noise resistance ±500 V the square wave noise(pulse width: 1㎲) by the noise simulator Vibration 1.5 mm amplitude at frequency or 300m/s Shock 500m/s
Ambient
Environ
temperature
-ment Ambient humidity 35 to 80%RH, storage: 35 to 80%RH
2
(approx. 50G) in each of X, Y, Z directions for 3 times
-10 to 55℃, storage: -20 to 60
Protection IP20(IEC standards) Mounting DIN rail or panel mounting
Accessories
1
Weight
1: The weight is with packaging and the weight in parentheses is only unit weight.
Environment resistance is rated at no freezing or condensation.
USB 2.0 Mini 5P type cable (length: 1 m), Connector for RS-485 (4-pin, male type) 1EA
Approx. 160g(approx. 57g)
RS485 communication specifications
Connection RS485 Standard EIA RS485 Protocol Modbus RTU Com. method 2-wire half duplex
Synchronous method Asynchronous
Effective com. distance
Com. speed
1
Max. 800m
4800, 9600, 19200, 38400, 57600, 115200bps (factory default: 115200bps)
1
Data bit Stop bit Parity bit
1
1
5bit,6bit,7bit,8bit(factory default:8bit) 1bit, 2bit(factory default: 1bit) None, Even, Odd(factory default: None)
Multi-drop Max. 31 Multi-drop
Connection type
1: You can set this by DAQMaster.
4-wire screw terminal (2-wire communication method)
SCM-US48I / SCM-38I / SCM-US
Model SCM-US48I SCM-38I SCM-US Power supply 5VDC USB bus Power 12-24VDC ± 10% 5VDC USB bus Power Power consumption Max. 1W Max. 1.7W Max. 1W Max. com speed Communication type Half duplex type
Available com. distance
Multi-drop Max. 31 multi-drop
Protocol
Connection type
Isolation type Isolation Non-isolation
Dielectric strength
1: USB bus power is supplied from PC or USB host controller.
2: Protocol and communication speed are set by Hyper terminal. DAQMaster, ParaSet, Modbus Poll.
When communicating with Autonics products, set communication speed to 9,600bps.
2
1,200 to 115,200bps(Recommended : 9,600bps)
USB: Max. 1m ± 30% RS485: Max.1.2km
Data bit 5 to 8 data bits
2
Stop bit 1 or 2 stop bits Parity bit None/Odd/Even
USB: B type connector RS232: D-sub 9Pin USB: A type connector
RS485: 4-wire screw terminal(2wire communication type)
●Between terminals and case: 200VAC 50/60Hz for 1 min.
●Between USB and RS485: 2500VAC 50/60Hz for 1 min.
2
of 10 to 55 Hz(for 1min.) in each of X, Y, Z directions for 2 hours
Wi-Fi communication specifications
Protocol TCP/IP(IPv4) Standard 802.11 b/g/n(IEEE 802.11b) compatible Com. speed Max. 11 Mbps Frequency range 2.4 to 2.497 GHz Security WEP, WPA, WPA2-PSK, Enterprise Antenna 2dBi external antenna Com. distance Max. 100 m
USB communication specifications
Power 5 V, 500 mA Standard USB 2.0(compatible sub-transmission) Com. method 2-wire half duplex Connections USB 2.0 Mini 5P type(Male)
Max. 1.2km 1.5m(not extension)
-
-
-
-
Earphone jack(4 pole stereo phone plug)
●Between terminals and case: 200VAC 50/60Hz for 1 min.
●Between RS232C and RS485: 2500VAC 50/60Hz for 1 min.
-
1
S-32
Communication Converter
Specifications
SCM-US48I / SCM-38I / SCM-US
Model SCM-US48I SCM-38I SCM-US
Insulation resistance Min. 100MΩ(at 500VDC megger)
Noise strength ±500V the square wave noise(pulse width: 1) by the noise simulator
Vibration
Shock
Environ
-ment
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 1 hour Malfunction 0.5mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 10 minutes Mechanical 300m/s Malfunction 100m/s
2
(approx. 30G) in each of X, Y, Z directions for 3 times
2
(approx. 10G) in each of X, Y, Z directions for 3 times
Ambient temperature -10 to 55℃, storage: -20 to 60℃ Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Approval
Accessory
USB 2.0 AB type connector (length: 1m)
-
Unit weight Approx. 34.5g Approx. 46g Approx. 41g
There might be some differences in the specication above depending on PC environment.
Environment resistance is rated at no freezing or condensation.
-
-

Integrated device management program (DAQMaster)

DAQMaster is the integrated device management program. Set the communication method switch of SCM-WF48 as USB, and connect this unit and a PC with USB cable. You can set the communication setting for SCM-WF48 by DAQMaster.
Visit our website (www.autonics.com) and download DAQMaster.
Item Minimum requirements System IBM PC compatible computer with Intel Pentium Ⅲ or above Operating system Memory 256MB or more Hard disk More than 1GB of free hard disk space VGA 1024×768 or higher resolution display Others RS-232 serial port(9-pin), USB port
Microsoft Windows 98/NT/XP/Vista/7

Part descriptions

SCM-WF48
1
2
5
6
3
4
6. Indicator
: Indicator for statue of AP mode and Infrastructure mode.
Mode Status
Red ON Initial error Green ON AP ready Orange ON Protocol socket error OFF Power is not supplied.
7. RS485 connector: Used for connecting RS485 communication cable.
8. USB connector: Used for connecting a PC, etc. with an USB cable.
AP mode Infrastructure mode
1
2
7
8
Try to AP connection AP connection is complete
1.Wi-Fi antenna
: Antenna for transmitting and receiving Wi-Fi communication
data. It may be broken when excessive pressure is applied.
2. Fixing screw hole
: Used for mounting the unit on a panel.
3. Rail Lock
: Used for fixing this unit at DIN rail mounting.
4. Communication method switch
: Switch for select communication method.
USB
RS485
(default)
For setting SCM-WF48I by DAQMater, select USB communication method.
5. Terminating resistance switch
: Switch for whether using terminating resistance.
RT OFF
(default)
[RT]: It uses terminating resistances. [OFF]: It does not use terminating resis­tance.
It is applied only when selecting RS485 communicaiton method.
Specifications of terminating resistance: 120 Ω, 1%(F) grade chip
resistance, 1/4 W
1: Re-set AP mode with DAQMaster.
2: Re-supply the power to server and client.
When power is supplied, this green/red indicator flashes 3 to 4
times in turn.
(A) Photo electric sensor
(B) Fiber optic sensor
(C) Door/Area sensor
(D) Proximity sensor
(E) Pressure sensor
(F) Rotary encoder
(G) Connector/ Socket
(H) Temp. controller
(I) SSR/ Power controller
(J) Counter
(K) Timer
(L) Panel meter
(M) Tacho/ Speed/ Pulse meter
(N) Display unit
(O) Sensor controller
(P) Switching mode power supply
(Q) Stepper motor& Driver&Controller
(R) Graphic/ Logic panel
(S) Field network device
(T) Software
(U) Other
S-33
SCM Series

Dimensions

SCM-WF48
(unit: mm)
28
76
2-Ø3.5
41.3
SCM-US48I
USB 2.0 AB type cable is including the product and is also sold separately.
(model: USB AB CABLE)
3-Ø4
39
25.3
45
98
(unit: mm)
USB 2.0 AB type cable
USB B Type
S-34
39
23.5
20
25.6
38
75.5
(unit: mm)
±30
1,000
±5
±5
20
USB A Type
Communication Converter
Dimensions
SCM-38I
39
3-Ø4
25.6
38
75.5
81.7
89
23.5
SCM-US
52
40.3
A C.C
12
18
O.P.R
Ø2.5×4P-1.5m
LED indicator
1
. O.P.R: Power
2
. A.C.C: Rx/Tx data transmission
8
4.5
1 2
VCC
R×D

Installations

SCM-WF48
Fixing screw
hole
Rail Lock DIN rail
Mounting to panel
1) This unit is able to mount on a panel with two fixing screws at center of both sides.
2) For mounting the unit, use M3 screws. Tighten screws with 0.4 N.m torque.
SCM-US48I & SCM-38I
M3 screw bolt
'A'(Height of layer)
'B'(Length of screw)
Panel
Mounting to and removing from DIN rail
Mounting
1) Hang up the backside holder on a DIN rail.
2) Press the unit toward ① direction until it snaps.
Removing
1) Pull rail locks of the backside of this unit to ② direction.
2) Pull the unit to ③ direction
'B'(Length of screw)
1 23.5mm 20mm
2 46.5mm 43mm
3 69.5mm 66mm
4 92.5mm 89mm
"A" size (23N+0.5)
(A) Photo electric
(unit: mm)
(unit: mm)
T×D
GND
8
12 18
"B" size
sensor
(B) Fiber optic sensor
(C) Door/Area sensor
(D) Proximity sensor
(E) Pressure sensor
(F) Rotary encoder
(G) Connector/ Socket
(H) Temp. controller
(I) SSR/ Power controller
(J) Counter
(K) Timer
(L) Panel meter
(M) Tacho/ Speed/ Pulse meter
(N) Display unit
(O) Sensor controller
(P) Switching mode power supply
(Q) Stepper motor& Driver&Controller
(R) Graphic/ Logic panel
(S) Field network device
(T) Software
(23N-3)
(U) Other
There is no Serial Port in SCM-US48I..
S-35
SCM Series

Example of connections

SCM-WF48
Cable connection
USB Mini 5P
(Male) type
Computer
USB A(Male)
type
Connection of SCM-WF48 and Multi-drop
B(-)
ON OFF
A(+)
SCM-WF48
GND
V(12-24VDC)
A(+) B(-) A(+) B(-) A(+) B(-)
DEVICE
Terminating
resistance (120)
RS485
#1
RS485
DEVICE
#2
AP mode
Wi-Fi or USB
connection
Computer
SCM-WF48
...
RS485
A B V G
SCM-WF48
B(-)
A(+)
RS485
DEVICE
#30
Connectable max. 31 units of
Autonics products which support
communication
+RS485
-RS485
Ground 24VDC
RS485
DEVICE
#31
Infrastructure mode
Wi-Fi or LAN
connection
Computer
One wireless router can connect
max. up to 254 units of SCM-WF48.
Before using this unit, set the communication method switch of SCM-WF48 as USB, and connect this unit and a PC with USB cable.
You can set the communication setting for SCM-WF48 by DAQMaster.
Wireless router
S-36
Wi-Fi
Wi-Fi
SCM-WF48
SCM-WF48
RS485
RS485
Connectable max. 31 units of
Autonics products which support
communication
Connectable max. 31 units of
Autonics products which support
communication
Communication Converter
SCM-48I
USB B Type
USB RS485
Terminating
resistance
(100 to 120Ω)
A(+) B(-) A(+) B(-) A(+) B(-)
Computer
B(-)
ON OFF
RS485
DEVICE
#1
RS485
DEVICE
#2
RS485
DEVICE
#30
A(+)
SCM-38I
A B V G
G: GROUND
V: 12-24VDC input
B(-)
RS485 signal line
A(+)
Multi-drop connection method with PC
RS232C RS485
R×D-R×D T×D-T×D
GND-GND
RS232C Cable
B(-)
Computer
ON OFF
A(+)
● RS232C
When the software of the communication driver uses Auto-loop Back, please connect as the above.
cable connection
Computer Computer
DCD
DSR RXD
RTS TXD CTS
DTR
GND
RI
<Standard connection> <Using Auto-loop Back>
SCM-38I SCM-38I
● Terminating resistance selection
ON: Using terminating resistance OFF: Not using terminating resistance
GND VCC (12-24VDC)
A(+) B(-)
RS485
DEVICE
#1
DCD DSR RXD
RTS TXD CTS DTR
RI
GND
Terminating
resistance
(100 to 120Ω)
A(+) B(-) A(+) B(-)
RS485
DEVICE
...
#2
RS485
DEVICE
#30
SCM-US
USB A Type
Serial
B(-)
A(+)
ON OFF
B(-)
A(+)
RS485
DEVICE
#31
RS485
DEVICE
#31
(A) Photo electric sensor
(B) Fiber optic sensor
(C) Door/Area sensor
(D) Proximity sensor
(E) Pressure sensor
(F) Rotary encoder
(G) Connector/ Socket
(H) Temp. controller
(I) SSR/ Power controller
(J) Counter
(K) Timer
(L) Panel meter
(M) Tacho/ Speed/ Pulse meter
(N) Display unit
(O) Sensor controller
(P) Switching mode power supply
(Q) Stepper motor& Driver&Controller
(R) Graphic/ Logic panel
(S) Field network device
(T) Software
(U) Other
Computer
USB
Autonics and Konics products
which support the PC loader port
S-37
SCM Series

Driver installation (SCM-WF48, SCM-US48I, SCM-US)

USB Driver Installation
1) Visit our website(www.autonics.com) to download USB Driver.
2) Unzip the downloaded 'SCM-WF48.zip', 'SCM-US48I. zip', or 'SCM-US.zip' at any directory.
3) When connecting product with USB port, 'Found New Hardware Wizard" will appear automatically. 'Do you want to search software by connecting 'Window Update'?. Click 'No' button and the following window will be displayed to proceed Driver installation. Select 'Install from a list or specific location' (Advanced)' (S) and click 'Next'.
6) Hardware installation message will appear while Found New Hardware Wizard is running. Click 'Continue Anyway' to proceed with installation.
7) The following window will be displayed if the USB Driver is installed properly. Click the 'Finish' button.
4)Select 'Search for best driver in these locations' and 'include this location in the search' continuously. Click the 'Browse' button.
5)When 'Browse Folder' window is displayed, select 'SCM­WF48\Driver' for SCM-WF48, or 'SCM-US\Driver' for SCM-US48I, SCM-US, and click 'Finish'. Click 'Next' to proceed with the USB Driver installation.
S-38
Serial Port Driver Installation
1) After installing USB Driver, Serial Port (COM port), 'Found New Hardware Wizard' will appear (Serial Port Driver installation follows the same procedures described in installing USB Driver).
2) After selecting 'Install from a list or specific location (advance)', click 'Next' button. The following window will be displayed for 'Search and installation options'
3) Because a driver location was selected when installing USB driver, click 'Next' button.
4)Hardware installation message will appear while Found New Hardware Wizard is running. Click 'Continue Anyway' to proceed with installation.
5)'Completing the Found New Hardware wizard' will be displayed if the Serial Port Driver is installed properly. Click the 'Finish' button.
Communication Converter
Verify that drivers were installed properly with the windows Device Manager after finishing USB Driver and Serial Port Driver installation. Open the folder [My computer], open the system folder (click right), click the hardware tab, and click the Device Manager Button. Then, make sure that 'SCM-WF48 Driver(Autonics Corp)', 'SCM-US48I Driver(Autonics Corp)' or 'SCM-US Driver(Autonics Corp)' is found in 'Common Serial Bus Controller' category and 'Port (COM and LPT) is found in 'SCM-WF48 Serial Port (COM □)', 'SCM-US48I Serial Port(COM Port(COM )'.
This Driver Installation is described based on the procedure for Windows XP. There might be some differences in the specification above depending on OS.
) or 'SCM-US Serial
(A) Photo electric sensor
(B) Fiber optic sensor
(C) Door/Area sensor
(D) Proximity sensor
(E) Pressure sensor
(F) Rotary encoder
(G) Connector/ Socket
(H) Temp. controller
(I) SSR/ Power controller
(J) Counter
(K) Timer
(L) Panel meter
(M) Tacho/ Speed/ Pulse meter
(N) Display unit
(O) Sensor controller
(P) Switching mode power supply
(Q) Stepper motor& Driver&Controller
(R) Graphic/ Logic panel
(S) Field network device
S-39
(T) Software
(U) Other
SCM Series

Proper usage

● In case of connecting PC with SCM-WF48, SCM-US48I or SCM-US, when changing PC USB port and connecting this
unit to another (changed) USB port, USB driver will be reinstalled. This is not a malfunction.
● When connecting SCM-US or SCM-US48I communication module, please connect PC first. Then, connect RS485
communication product afterward. When disconnecting the units, remove the unit in reverse order.
● Using the Twisted pair cable (AWG24), which is suitable to RS485 communication is recommended. If the Twisted pair
cable is not used, be sure preserving identically the length of A(+) and B(-) cables.
● After connecting SCM-WF48 with RS485 communication DEVICE, be sure to attach the terminating resistor (120Ω).
After connecting SCM-38I, SCM-US48I with RS485 communication DEVICE, be sure to attach the terminating resistor (100 to 120Ω).
● In case of connect PC with SCM-WF48, SCM-US48I, or SCM-US , No. of COM Port will be numbered in order.
This is not a malfunction. (e.g. COM 14, COM 15, ..., COM 256)
● When connecting SCM-WF48, SCM-US48I or SCM-US with USB cable, check COM port number before communication.
It may take some time for computer to detect the cable after the cable is connected. (This is not a malfunction.)
● When connecting PC with SCM-WF48, SCM-48I or SCM-US, do not use the extension cable to extend USB cable length.
It may cause a malfunctions.
● Be cautious when using SCM-WF48 or SCM-US as non-isolated type.
Check the connection, disconnection and short of communication cable before supplying the power to SCM-WF48.
● Only use Autonics products that are available for SCM-US.
● Observe the rated voltage.
● To avoid malfunctions due to noise, do not place the unit close to a high-voltage power line.
● Proper application environment
(Avoid following environments for unit to be used.)
• Where severe vibration or shock exists
• Where close to a strong alkali or strong acid
• Where direct rays of light exist
• Where near facilities generating strong magnetic forces or electric noise.
● Storage
Keep the unit -20 to 60℃, 35 to 85%RH with avoiding direct rays of light. It is recommended to keep the unit package as it is.
● Installation environment
• It shall be used indoor
• Altitude max. 2000m
• Pollution degree 2
• Installation category II
S-40
Loading...