Autonics PSS Series Catalog Page

PSS Series
Compact, Non-indicating Pressure Sensors
Features
● Rated pressure : negative pressure (-101.3 to 0.0kPa) standard pressure (0 to 100.0kPa, 0 to 1,000kPa) compound pressure (-101.3 to 100.0kPa)
● Compact design: W11.8×H29.3×L24.8mm (including pressure port)
● Power supply: 12-24VDC ±10%
Please read “Safety Considerations” in the instruction manual before using.
Ordering Information
PS S V V01 R1/8
Pressure port
Output
Pressure range
Pressure type
Size
Item
R1/8 Standard
V Voltage (1-5VDC) output A Current (DC4-20mA) output
01 100kPa 1 1,000kPa
No-mark Standard pressure type V Negative pressure type C Compound pressure type
S Small (W11.8×H29.3×L24.8mm)
PS Pressure Sensor
Specifications
Pressure type
Voltage output
Model
Current output Rated pressure range 0.0 to -101.3kPa 0.0 to 100.0kPa 0 to 1,000kPa -101.3 to 100.0kPa Analog output range 5.0 to -101.3kPa -5.0 to 110.0kPa -50 to 1,100kPa -101.3 to 110.0kPa Max. pressure range 2 times of rated pressure 2 times of rated pressure 1.5 times of rated pressure 2 times of rated pressure Applied uid Air, non-corrosive gas Power supply 12-24VDCᜡ ±10% (ripple P-P: Max. 10%) Current consumption Voltage output type: Max. 15mA, Current output type: E󰀨ect by power supply Max. ±0.3% F.S. Protection circuit Reverse polarity protection circuit
Voltage output •Output voltage: 1-5VDCᜡ ±2% F.S. •Linear: Max. ±1% F.S. •Output impedance: 1kΩ
Analog output
Current output •Output current: DC4-20mA ±2% F.S. Temp. characteristics of
analog output Insulation resistance Over 50MΩ (at 500VDC megger) Dielectric strength 2000VAC 50/60Hz for 1 minute Vibration 1.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours
Environment
Protection structure IP40 (IEC standard) Material Front, Rear case: Polycarbonate, Pressure port: Nickel plated brass Cable Ø3, 4-wire, 3m (AWG28, Core diameter: 0.08mm, Number of cores: 19, Insulator out diameter: Ø0.88mm) Sold separately Sensor connector wire mount plug (CNE-P04- ) Approval Weight
1: For more information about sensor connector wire mount plug, refer to 'Connectors' and 'Sockets' chapters.
2: The weight includes packaging. The weight in parenthesis is for unit only.
F.S.: Rated pressure.
Environment resistance is rated at no freezing or condensation.
Ambient temp. 0 to 50℃, storage: -10 to 60 Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
2
Gauge pressure Negative pressure Standard pressure Compound pressure
PSS-V01V-R1/8 PSS-01V-R1/8 PSS-1V-R1/8 PSS-C01V-R1/8 PSS-V01A-R1/8 PSS-01A-R1/8 PSS-1A-R1/8 PSS-C01A-R1/8
-
•Linear: Max. ±1% F.S.
Max. ±2% F.S. of output voltage/current at 25℃ within temperature range 0 to 50
1
Approx. 60g (approx. 26g)
G-44
Dimensions
Compact, Non-indicating Pressure Sensor
(unit: mm)
SENSORS
CONTROLLERS
11.8
19.8
5
12.8
R1/8"
Ø3, 3m
16.5
12
Connections
Inside M5 Tap
● Voltage (1-5VDC) output type ● Current (DC4-20mA) output type
(Brown)+V
(Black) Voltage (1-5VDC) output
12-24VDC
Main circuit
Main circuit
(White) Pressure sensor model recognition
2
(Blue)GND
1 : Load can be connected any directions.
2 : Pressure sensor model is automatically recognized only by Autonics PSM Series, Multi-CH Pressure and Sensor indicator.
Allowable load impedance: Max. 100Ω for 12VDC power, Max. 500Ω for 24VDC power The product is not equipped with the output short over current protection circuit. If short-circuit the control output terminal or supply
※
(Brown)+V
(White) Pressure sensor model recognition
2
(Black)N.C
(Blue)0V/Current (DC4-20mA) output
current over the rated specification, it may result in product damage.
Proper Usage
Do not insert any sharp or pointed object into pressure port.
Failure to follow this instruction may result in malfunction and damage the sensor. Be sure that this unit must avoid direct touch with water, oil, thinner etc. It is ready to operate 3 sec after it is turned ON. Be sure not to use the product within 3 sec. When using switching mode power supply, frame ground (F.G.) terminal of power supply should be grounded. To avoid inductive noise, keep the wiring away from power line, high voltage line.
Failure to follow this instruction may result in malfunction. When moving this unit from warm place to cold place,
please remove the humidity on the cover then use it. Do not use spanner to mounting this unit.
Tightening torque for one touch tting should be below 10N·m. Do not apply a tensile strength in excess of 30N to the cables
or connector. This product may be used in the following environments.
Indoors Altitude max. 2,000m Pollution degree 3 Installation category II
Switching Mode Power Supply
Load
Load
F.G.
1
1
+
-
12-24VDC
MOTION DEVICES
SOFTWARE
(A) Photoelectric Sensors
(B) Fiber Optic Sensors
(C) LiDAR
(D) Door/Area Sensors
(E) Vision Sensors
(F) Proximity Sensors
(G) Pressure Sensors
(H) Rotary Encoders
(I) Connectors/ Connector Cables/ Sensor Distribution Boxes/ Sockets
G-45