DRW171507AA
Autonics
INDUCTIVE PROXIMITY SENSOR(SQUARE AC 2WIRE)
PSN SERIES
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
▣ Safety Considerations
Please observe all safety considerations for safe and proper product opera ion to avoid hazards.
※
※
symbol represents caution due to special circumstances in which hazards may occur.
Warning Failure to follow these instructions may result in serious injury or death.
Caution
Failure to follow these instructions may result in personal injury or product damage.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or
substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways,
aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or re.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct sunlight,
radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
4. Do not supply power without load.
Failure to follow this instruction may result in re or product damage.
▣ Ordering Information
P SN
Shape
Item
▣ Control Output Diagram & Load Operating
Main circuit
▣ Connection of the Power Supply
Be sure to supply the power after connecting the load, because direct connection of the proximity sensor may cause
damage to the inner elements of this product.
525
Dimension
AC
Control output
Sensing distance
Brown
Load
Blue
100-240VAC
50/60Hz
100-240VAC
50/60Hz
AO
Normally Open(N.O )
AC
I I
Number Sensing distance(Unit: mm)
Number A side length(Unit: mm)
Sensing
target
Load
Operation
indicator
(Red LED)
Normally Closed(N.C.)
SN Square
P Inductive proximity sensor
Normally
Open
Presence
_O__
Nothing
Operation
Return
ON
OFF
_O__
_O__
Operation
Load
Normally
Closed
Presence
Nothing
Return
ON
OFF
100-240VAC
50/60Hz
CD<OO
The above specications are subject to change and some models may be discontinued without notice.
※
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog,
※
homepage).
▣ Specications ▣ Mutual-interference & Inuence by Surrounding Metals
I
Model
Sensing distance 5mm 10mm 15mm 20mm
'
Hysteresis Max. 10% of sensing distance
Standard sensing
target
Set ing distance 0 to 3.5mm 0 to 7mm 0 to 10.5mm 0 to 14mm
Power supply
(Operating voltage)
Lackage current Max. 2.5mA
~
Response frequency 20Hz
~
Residual voltage Max. 10V
Effect by Temp. Within ±10℃ max. of sensing distance at 20℃ in temperature range of -25 to 70
Control output 5 to 200mA
Insulation resistance Min. 50㏁(at 500VDC megger)
Dielectric strength 1,500VAC 50/60Hz for 1 minute
Vibration 1mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 2 hours
Shock 500m/s
I =
Indicator Operating indicator(Red LED)
l
~
Environment
Protection circuit Surge protection
L__
Protection IP67(IEC standards)
L__
Cable
'
Materials Case: Heat-resistant ABS, Standard cable(Black): Polyvinyl chloride(PVC)
Approval
L--
Unit Weight Approx. 65g Approx. 106g Approx. 152g
※
※
Ambient
temperature
Ambient
humidity
F
1
※
1. Do not pull the cable with a tensile strength of 30N or over. It may result in fire due to the broken wire. When
extending wire, use AWG22 cable or over within 200m.
Environment resistance is rated at no freezing or condensation.
I
PSN25-5AO
PSN25-5AC
25×25×1mm(Iron) 30×30×1mm(Iron) 45×45×1mm(Iron) 60×60×1mm(Iron)
100-240VACᜠ 50/60Hz
(85-264VACᜠ)
2
(approx. 50G) in X, Y, Z direc ions for 3 times
-25 to 70℃, Storage: -30 to 80
35 to 95%RH, Storage: 35 to 95%RH
Ø4mm, 2 cores, 2m
(AWG22, core diameter: 0.08mm, number of cores: 60, insulator diameter: Ø1.25mm)
(€
l
PSN30-10AO
PSN30-10AC
I
℃
I
▣ Dimensions
PSN25 / PSN30 / PSN40
B
A
E
F
When installing the product, tighten the screw with a tightening torque of 0.98N.m
※
◎Bracket
C
D
LED
H
G 2000
l
PSN30-15AO
PSN30-15AC
l
A
B
C
D
E
F
G
H
PSN40-20AO
PSN40-20AC
I
I
~
I
I
℃
l
PSN25 PSN30 PSN40
25 30 40
35.5 48.5 47
Ø4.2 Ø4 5 Ø5.5
18 22 30
25.3
16.8
39
4
30 40
20 25
53 53
4 4
~
(Unit: mm)
◎Mutual-interference
When several proximity sensors are mounted closely, malfunction of sensor may be caused due to mutual interference. Therefore, be
sure to keep a minimum distance between the two sensors as below chart.
Face to Face Parallel
A
ℓ
7
◎Influence by surrounding metals
When sensors are mounted on metallic panel, it is required to protect the sensors from malfunction by any metallic object. Therefore,
be sure to keep a minimum distance as below chart.
~
C
d
-
B
7
l
Item
f
I
L
l
l
Model
A
B
C
d
ℓ
m
PSN25
30 60 90 120
40 50 65 70
5 5 5 5
15 30 45 60
25 30 45 45
20 25 35 35
10mm 15mm
PSN30
l ,
▣ Setting Distance
Target
Moving
direction
(a)
●
Sensing distance can be changed by the shape, size or material of the target.
Therefore please check the sensing distance like (a), then pass the target within range of setting distance(Sa) like (b).
●
Setting distance(Sa)= Sensing distance(Sn) × 70%
E g.) PSN30-10AO
Setting distance(Sa) = 10mm × 0.7 = 7mm
Sn:
Sensing distance
{
Sa:
Setting distance
(70% of Sn)
Moving
direction
▣ Caution during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
Do not use near the equipment which generates strong magnetic force or high frequency noise (transceiver, etc.).
In case installing the product near the equipment which generates strong surge (motor, welding machine, etc.), use diode or varistor
to remove surge.
3. Do not connect capacity load to the output terminal directly.
4. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specifications')
①
Altitude max. 2,000m
②
Pollution degree 2
③
Installation category II
④
Target
Sn
Sa
(b)
▣ Major Products
●
2-M4 TAP
25
PSN25
3 5
18
11.8
10
d2
32
2-4.5
12
17.5
2
t
●
PSN30
2-M4 TAP
30 5
3.5
22
14
15
rfe
●
34
2-4.3
16
17.8
2
PSN40
2-M5 TAP
40
35
6
2-5 5
30
19.5
15 5
24
22
2
i
Photoelectric Sensors Temperature Controllers
■
Fiber Optic Sensors Temperature/Humidity Transducers
■
Door Sensors SSRs/Power Controllers
■
Door Side Sensors Counters
■
Area Sensors Timers
■
Proximity Sensors Panel Meters
■
Pressure Sensors Tachometers/Pulse (Rate) Meters
■
Rotary Encoders Display Units
■
Connectors/Sockets Sensor Controllers
■
Switching Mode Power Supplies
■
Control Switches/Lamps/Buzzers
■
I/O Terminal Blocks & Cables
■
Stepper Motors/Drivers/Motion Controllers
■
Graphic/Logic Panels
■
Field Network Devices
■
Laser Marking System (Fiber, Co₂, Nd: YAG)
■
Laser Welding/Cutting System
■
■
■
■
■
■
■
■
■
■
m
m
(Unit: mm)
PSN40
DRW171507AA