Autonics BF4RP, BF4GP, BF4R, BF4R-E, BF4G Instructions Manual

...
BF4 Series
High reliability of fiber optic amplifier for convenient mounting

Features

● High speed response : Max. 0.5ms
● Auto sensitivity setting(Button setting)/Remote sensitivity setting
● External synchronization input, mutual interference protection, self-diagnosis
● Reverse power polarity and short-circuit(Overcurrent) protection circuit
● Automatically selectable Light ON / Dark ON
● Precise detection of small target and complicated place to install
Please read “Caution for your safety” in operation manual before using.

Specifications

Model
Response frequency Max. 0.5ms(Frequency 1), Max. 0.7ms(Frequency 2) Power supply 12-24VDC ±10%(Ripple P-P: Max.10%) Current consumption Max. 45mA Light source
(modulated light) Sensitivity adjustment Sensitivity adjustment button(ON/OFF) Operation mode Automatic selection of Light ON/Dark ON accordance with button setting
Control output
Self-diagnosis output
Protection circuit Reverse power polarity, short-circuit(overcurrent) protection circuit Indicator Operation indicator : Red LED, Stability indicator : Green LED ON when the target stays in stable sensing level Input of stop
transmission function External synchroniza-
tion function Remote sensitivity
setting function Interference
prevention function Timer function
(selectable) Ambient illumination Sunlight : Max. 11,000㏓, Incandescent lamp : Max. 3,000 Noise resistance ±240V the square wave noise(pulse width : 1㎲) by the noise simulator Dielectric strength 1,000VAC 50/60Hz for 1 minute Insulation resistance Min. 20MΩ(at 500VDC megger) Vibration 1.5mm amplitude or 300m/s Shock 500m/s²(approx. 50G) in each of X, Y, Z directions for 3 times
Ambient illumination
Environ-
Ambient
ment
temperature Ambient
humidity
Material Case : Heat-resistance ABS, Cover : PC
Cable
Accessory Mounting bracket, Bolts/nuts Approval Unit weight Approx. 65g
1: Frequency 1(Normal mode) : Max. 0.5ms, Frequency 2 : Max. 0.7ms
The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.
Standard type
BF4RP BF4GP BF4R BF4G BF4R-E BF4G-E BF4R-R BF4G-R
Red Green Red Green Red Green Red Green
NPN or PNP open collector output
● Load voltage: Max. 30VDC ● Load current: Max. 100mA
● Residual voltage - NPN: Max. 1V(load current: 100mA), Max. 0.4V(load current:16mA) / PNP: Max. 2.5V ON state under unstable sensing(When the target stays for 300ms in unstable area),
ON state when control output short-circuited
● Load voltage: Max. 30VDC ● Load current: Max. 50mA
● Residual voltage - NPN: Max. 1V(load current: 50mA), Max. 0.4V(load current:16mA) / PNP: Max. 2.5V
-
-
- -
Built-in differential frequency mode (set by frequency 1 or 2 by ON/OFF button)
1
Built-in OFF delay timer, Approx. 40ms xed
2
at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
Sunlight : Max. 11000㏓, Incandescent lamp : Max. 3000㏓ (received illumination)
-10 to 50℃, storage : -20 to 70
35 to 85% RH, storage :35 to 85% RH
Ø4, 4-wire, Length: 2m (AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator out diameter : Ø1.25mm)
External synchronization input type
Built-in
Built-in(Gate/Trigger)
-
㏓(Receiver illumination)
Ø4, 6-wire, Length: 2m (AWG24, Core diameter: 0.08mm, Number of cores: 40, Insulator out diameter : Ø1mm)
Remote sensitivity setting type
-
-
Built-in
Built-in OFF delay timer , Approx. 40ms xed
B-30
Fiber Optic Amplier

Control output diagram

BF4R / BF4G BF4RP / BF4GP
Fiber optic sensor circuit Connection Fiber optic sensor circuit Connection
(Brown)+V
Load
(Black) Control output
Max. 100mA
Main circuit
(White) Self-diagnosis output
(Blue)0V
Load
Max. 50mA
+
12-24VDC
-
Main circuit
(Brown)+V
(Black)Control output
Max. 50mA
(White) Self-diagnosis
output
Load
(Blue)0V
Max. 100mA
Load
BF4R-E / BF4G-E BF4R-R / BF4G-R
Fiber optic sensor circuit
(Brown)+V
(Pink)
External synchronization input
(Orange)
Emission disable input
Main circuit
(Black) Control output
(White) Self-diagnosis output
(Blue)0V
Connect Diode at external terminal for inductive load.
Connection
Load
Max. 100mA
Max. 50mA
Load
+
12-24VDC
-
Fiber optic sensor circuit
Main circuit
(Brown)+V
(Pink)
ON input of remote sensitivity setting
(Orange)
OFF input of remote sensitivity setting
(Black) Control output
(White) Self- diagnosis output
(Blue)0V
Connection
Load
Max. 100mA
Max. 50mA

Connections

● BF4R / BF4G
● BF4RP / BF4GP
Load
(A) Photo electric sensor
(B) Fiber optic sensor
(C) Door/Area sensor
+
12-24VDC
-
+
­12-24VDC
(D) Proximity sensor
(E) Pressure sensor
(F) Rotary encoder
(G) Connector/ Socket
(H) Temp. controller
(I) SSR/ Power controller
(J) Counter
(K) Timer
(L) Panel meter
(M) Tacho/ Speed/ Pulse meter
(N) Display unit
(Brown) +V
(Black) Control output
(White) Self-diagnosis output
(Blue) 0V
● BF4R-E / BF4G-E
(Brown) +V (Pink) External synchronization input
(Orange) Emission disable input
(Black) Control output
(White) Self-diagnosis output
(Blue) 0V
Load
Load
Load
+
12-24VDC±10%
-
Load
+
12-24VDC±10%
-
(Brown) +V
(Black) Control output
(White) Self-diagnosis output
(Blue) 0V
Load
● BF4R-R / BF4G-R
(Brown) +V
(Pink) ON input of remote sensitivity setting
(Orange) OFF input of remote sensitivity setting
(Black) Control output
(White) Self-diagnosis output
(Blue)0V
Load
+
12-24VDC±10%
-
Load
Load
+
12-24VDC±10%
-
B-31
(O) Sensor controller
(P) Switching mode power supply
(Q) Stepper motor& Driver&Controller
(R) Graphic/ Logic panel
(S) Field network device
(T) Software
(U) Other
BF4 Series

Dimensions

12
34
7.3 8 3
16.4
62
36.5
Cable:Ø4, 2m

Installations

Mounting amplifier unit
● When mounting the amplifier
Hook the front part of the amplifier on
DIN rail(or bracket). Press the rear part of the amplifier on
DIN rail(or bracket).
● When releasing the amplifier
Push the back of amplifier toward ③ and lift the hole for fiber toward ④ up then simply take it out without tools.
● Connect the bracket
12
8
12
38
4
26.9
● Bracket
2
65.3
Ø4
9
14
35mm DIN rail useable
R1.6
8.5
4
Installation of fiber optic cable
● In case of using L bracket
L bracket
Fixing nut
● In case of using screw
Tightening torque: Max. 2kgf.cm
(unit: mm)
16
35
2
14 27
12
1
Notice: If setting bolt is tightened with over
specified tightening torque, hood of
Connection of fiber optic cable & amplifier
Open the lock lever to "
Insert the fiber optic cable in the amplifier slowly.
fiber optic cable may be damaged.
(Depth: approx. 10mm)
Close the lock lever to "

Parts description

● BF4R / BF4G / BF4RP / BF4GP / BF4R-R / BF4G-R ● BF4R-E / BF4G-E
Control output indicator(red) Stability indicator(green)
Mode selection switch
Timer selection switch NON:Not useing timer function OFD:OFF Delay timer
Sensitivity setting button
B-32
" direction.
" direction.
Control output indicator(red) Stability indicator(green)
Mode selection switch
External synchronization selection switch TRIG:Trigger synchronization GATE:Gate synchronization
Sensitivity setting button
Fiber Optic Amplier

Setting mode

Sensitivity setting
Light ON Dark ON
Press [ON] button
at light ON
Press [OFF] button
at light OFF
Change the mode selection switch to SET
Press [OFF] button
at light ON
Press [ON] button
at light OFF
Set interference protection function
Press ON+OFF at the same time for 2 sec.
STAB indicator flashes continuously
Cancellation of interference protection function (Normal mode)
Press [ON], [OFF] buttons
at the same time
STAB indicator flashes one time when the difference of sensitivity between ON and OFF
(Normal mode, Response
time : Max. 0.5ms)
is enough, but STAB indicator flashes 5 times when the difference is not enough
Set the mode selection switch to LOCK (Completes setting)

Sensitivity adjustment

Adjustment by the sensitivity setting button(Common)
● Light ON
The control output turns on at Light ON status and turns off at Light OFF status.
Order Setting method
Mount the ber optic cable within sensing distance.
Change the mode selection switch to [SET].
Diffuse reective: Press [ON] button with a sensing target. Transmitted beam: Press [ON] button without a sensing target.
<Transmitted beam>
Light ON
Stability indicator ashes at ON state.
(Check the target position)
Diffuse reective: Press [OFF] button without a sensing target. Transmitted beam: Press [OFF] button with a sensing target.
<Transmitted beam>
Light ON
• When there is enough sensitivity difference between ON state and OFF state, the STAB indicator ashes one time only at stable sensing level.
• When there is not enough sensitivity difference between ON state and OFF state, the STAB indicator ashes ve times at unstable sensing level.
Change the mode selection switch to [LOCK], even though the sensitivity setting button is touched,
setting sensitivity shall not be changed.
1. The sensitivity can be set at unstable sensing area.
When the power is OFF, the set sensitivity is saved.
After completing sensitivity setting, do not move or bend 󰘰ber cable.
It may not detect it properly.
<Diffuse reflective >
(Low reflectance)
Light ON
<Diffuse reflective >
Mark (Low
reflectance)
Light ON
1
Mark
Background
(High
reflectance)
Background
(High
reflectance)
OUT
STAB
● Dark ON
The control output turns off at Light ON status and turns on at Light OFF status.
<How to set sensitivity>
Most of adjustments except ③ & ⑤ are same as Light ON mode.
state
- ③
Diffuse reective: Press [ON] button without a sensing target. Through-beam: Press [ON] button with a sensing target.
state
- ⑤
Diffuse reective: Press [OFF] button with a sensing target. Through-beam: Press [OFF] button without a sensing target.
SET
LOCK
STAB indicator turns off
<Transmitted beam>
Light ON
<Transmitted beam>
Light ON
Select the frequency 1
Press [ON] button
(Frequency 1,
Response time
: Max. 0.5ms)
SET
LOCK
<Diffuse reflective >
Mark (Low
reflectance)
Light ON
<Diffuse reflective >
Mark (Low reflectance)
Light ON
Setting of interference protection function (Differential frequency mode)
Select the frequency 2
Press [OFF] button
(Frequency 2,
Response time
: Max. 0.7ms)
Background
(High
reflectance)
Background
(High
reflectance)
(A) Photo electric sensor
(B) Fiber optic sensor
(C) Door/Area sensor
(D) Proximity sensor
(E) Pressure sensor
(F) Rotary encoder
(G) Connector/ Socket
(H) Temp. controller
(I) SSR/ Power controller
(J) Counter
(K) Timer
(L) Panel meter
(M) Tacho/ Speed/ Pulse meter
(N) Display unit
(O) Sensor controller
(P) Switching mode power supply
(Q) Stepper motor& Driver&Controller
(R) Graphic/ Logic panel
(S) Field network device
(T) Software
(U) Other
B-33
BF4 Series
To set as max. sensitivity(Common)
① Execute the general sensitivity setting.
Set the mode selection switch to [SET] mode.
If there is no sensing target,
- Light ON: Press the [ONOFF] button
- Dark ON: Press the [OFFON] button the mode selection switch to [LOCK] mode.
④ Set ※
External sensitivity setting
- Light ON(From above ③)
External sensitivity setting ON input(High→Low→High) External sensitivity setting OFF input (High→Low→High)
- Dark ON Mode(From above ③)
External sensitivity setting OFF input(High→Low→High) External sensitivity setting ON input(High→Low→High)
< Application >
● To extend sensing distance by the diffuse reective type:
If ber optic sensor is used in place where there are targets with high reectivity and low reectivity, it is able to get stable detection by adjusting max. sensitivity.
● When it is used as transmitted beam type at bad
environment : If ber optic sensor is used in place where there is lots of dust or moisture, it might cause malfunction. Please max. sensitivity then it can perform stable detection.
Remote sensitivity adjustment[BF4R(G)-R]
BF4R-R/BF4G-R type can adjust the sensitivity with input signal lines regardless of the mode selection switch as following diagram ;
(Brown) +V
(Black) Control output
(White) Self-diagnosis output
(Pink)ON input of remote sensitivity setting
(Orange)OFF input of remote sensitivity setting
(Blue)0V
Adjustment at Light ON
ON input of remote sensitivity setting(SW1) :
SW1 turns on and then turns off instead of ③ state of adjustment by the sensitivity setting button.
OFF input of remote sensitivity setting(
SW2 turns on and then turns off instead of ⑤ state of adjustment by the sensitivity setting button.
Adjustment at Dark ON
OFF input of remote sensitivity setting(SW2) :
SW2 turns on and then turns off instead of ③ state of adjustment by the sensitivity setting button.
ON input of remote sensitivity setting(
SW1 turns on and then turns off instead of ⑤ state of adjustment by the sensitivity setting button.
<External sensitivity setting input signal condition>
State Signal condition High 4.5-30VDC or Open Low 0-1VDC
*Input impedance:10kΩ
S/W2 S/W1
) :
SW2
) :
SW1
Prohibition of inputting External
sensitivity setting[BF4R(G)-R]
Even though mode switch is at Lock position, it is able to input external sensitivity setting when Switch1 and Switch 2 are ON. Therefore please install Switch3 in order to prevent from malfunction as below.
SW3 - OFF : Disable to set external sensitivity
SW3 - ON : Enable to set external sensitivity
(Brown) +V
(Black) Control output
(White) Self-diagnosis output
(Pink)ON input of remote sensitivity setting
(Orange)OFF input of remote sensitivity setting
(Blue)0V
Switch for prohibiting sensitivity setting
S/W3
W2 S/W1
S
/
Answer Back function[BF4R(G)-R]
When ON or OFF input of remote sensitivity setting is applied, after 300ms, self-diagnosis output turns on for 40ms and then the sensor keeps normal sensing state. (Note: Time chart)
Self-diagnosis output does not turn on if there is no difference of sensitivity between ON input and OFF input and stable sensing is not executed, but stable sensing operates after 340ms.
<Time Chart : Light ON mode >
Power supply
Remote
sensitivity
setting
ON input
Remote
sensitivity
setting
OFF input
Self-
diagnosis
output
(Answer
back
function)
Sensing
output
During period T3(Approx. 300ms), do not change the light ON value by moving the object, etc.
1. T1≥1,000ms (After power turns on, it can be set after 1sec.)
2. T2≥5ms (ON or OFF input time of remote sensitivity setting must be min. 5ms)
3. T3≒300ms (When ON or OFF input of remote sensitivity setting is applied, self-diagnosis output turns on after 300ms)
4. T4≒40ms (ON time of self-diagnosis output)
5. T5≥500ms (When ON input of remote sensitivity setting is applied and then apply OFF input of remote sensitivity setting after 500ms)
ON
OFF
High
(OFF)
Low
(ON)
High
(OFF)
Low
(ON)
ON
OFF
T1 T2
T5 T2
T3
T4 T4
T3
Detectable
B-34
Fiber Optic Amplier

OFF Delay timer function

(BF4R/BF4RP/BF4R-R/BF4G/BF4GP/BF4G-R)
Standard type and Remote sensitivity setting type both contain a built-in approx. 40ms fixed OFF Delay timer. The timer works when the timer selection switch is set to 'OFD'. The output is turned off after remaining on for additional 40ms at OFF position of the sensing output. It is useful when the response time of the connected device is slow or when the sensing signal from a tiny object is too short.
<Time Chart>
Sensing
Sensing
state
Light
ON
Dark
Normal
ON
Light
ON
Timer
Dark
ON
Non­Sensing
Output operation
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T T T
T
T≒40
Timer
selection
switch
External synchronization input
function [BF4R(G)-E]
By using external synchronization function, the time for making sensing can be specified by external synchronization. Trigger synchronization and gate synchronization are available.
Trigger synchronization Gate synchronization
(Note)
Sensing
signal
External
synchroni-
zation
input
Control
output
External
synchroni-
zation
selection
switch
ON
OFF
High
Low
Approx. 40ms
ON
OFF
Control output is fixed
as 40ms.
TRIG
T T
ON
OFF
High
Low
ON
OFF
GATE
Stop transmission function
[BF4R(G)-E]-Operation test
● Below test is available under Light ON state only.
● If input of stop transmission is at Low state, transmission light will be stopped.
● It can check normal or abnormal state of the sensor without moving the target.
(Orange)Input of stop transmission
High or Open
(Blue)0V
[If input of stop transmission is at High or Open state, light is transmitted.]
(Orange)Input of stop transmission
Low
(Blue)0V
[If input of stop transmission is at Low, light is transmitted.]
Input of stop transmission
Sensing output
(If it is in ON
state when light
High
(OFF)
Low
(ON)
ON
OFF
is not received)
: Transmission area, ②: Stop transmission area
(Note1) If transmission is stopped control output must
turn on, but if control output does not turn on, it seems that sensor has some problems.
.5ms
T≥0
(When using interference prevention function T≥0.7ms)
<Input signal condition for Stop transmission>
State Signal condition High 4.5-30VDC or Open Low 0-1VDC
T T T
(Note1)
Normal
Abnormal
(A) Photo electric sensor
(B) Fiber optic sensor
(C) Door/Area sensor
(D) Proximity sensor
(E) Pressure sensor
(F) Rotary encoder
(G) Connector/ Socket
(H) Temp. controller
(I) SSR/ Power controller
(J) Counter
(K) Timer
(L) Panel meter
(M) Tacho/ Speed/ Pulse meter
(N) Display unit
(O) Sensor controller
(P) Switching mode power supply
(Q) Stepper motor& Driver&Controller
(R) Graphic/ Logic panel
(S) Field network device
T≥0.5ms (using interference prevention function: T≥0.7ms)
(Note) Actual signal detected by sensor.
<Input signal condition for External synchronization>
State Signal condition High 4.5-30VDC or Open Low 0-1VDC
B-35
(T) Software
(U) Other
BF4 Series

Self-diagnosis function(Common)

When fiber hood is contaminated by dust, transmitted light is lowered by element ability loss or received light is lowered by missing of optical axis, the self-diagnosis output will turn on.
Light ON mode
Move to
unstable level
Unstable
operation
level
Stability
indicator
Control
output
indicator
(OUT)
Self-diagnosis
output(Alarm)
The self-diagnosis output turns off during stable
Light ON
incomplete
300
unstable level
Out of
detection.(① position)
detecting state remains for 300ms at unstable
② When
level between stable light OFF level and stable light ON level, self diagnosis output turns on, self-diagnosis output turns off at lower than stable light OFF level and upper than stable light ON level. (② position)
the control output turns on, if an overcurrent
③ When
condition exists in control output, then self-diagnosis output turns on.
Move to
unstable level
Light OFF
incomplete
300
Move to
unstable level
Stable light ON level
Control output operation level
Stable light off level
ON OFF
Light ON Light OFF
ON OFF
Interference prevention function
(Common)
BF4R series has interference prevention function, two fiber optic cables can be mounted very closely by setting different transmission frequencies.
●Interference prevention function
(Operation of differential frequency mode)
First sensor- Frequency 1(Response time: max. 0.5ms)
Set the mode selection switch to [SET].
Press the [ON] & [OFF] buttons for
2sec. at the same time.
The [STAB] indicator flashes continuously.
Press the [ON] button.
The [STAB] indicator turns off.
OUT
STAB
Flashing
Set the mode selection switch to [LOCK].
Second sensor- Frequency 2(Response time: max. 0.7ms)
Set the mode selection switch to [SET].
Press the [ON] & [OFF] buttons for
2sec. at the same time.
The [STAB] indicator flashes continuously.
Press the [OFF] button.
The [STAB] indicator turns off.
OUT
STAB
Light off
B-36
OUT
STAB
Flashing Light off
Set the mode selection switch to [LOCK].
OUT
STAB
● Interference prevention function
(Operation of normal mode)
Set the mode selection switch to [SET].
Press the [ON] & [OFF] buttons for 2 sec. at the same
time.
The stable indicator flashes continuously.
Press the [ON] & [OFF] buttons at the same time.
[STAB] indicator turns off.
⑤The
the mode selection switch to [LOCK].
⑥Set ※
When interference prevention function is used,
hysteresis & response time will be longer than normal
operation(Response time : Max. 0.5ms).
Loading...