● Reverse power polarity and short-circuit(Overcurrent) protection circuit
● Timer function : Selectable None / 40ms OFF Delay timer(xed)
(Standard type, remote sensitivity setting type only)
● Automatically selectable Light ON / Dark ON
● Precise detection of small target and complicated place to install
Please read “Caution for your safety” in operation
manual before using.
Specifications
Model
Response frequency Max. 0.5ms(Frequency 1), Max. 0.7ms(Frequency 2)
Power supply12-24VDC ±10%(Ripple P-P: Max.10%)
Current consumption Max. 45mA
Light source
(modulated light)
Sensitivity adjustment Sensitivity adjustment button(ON/OFF)
Operation modeAutomatic selection of Light ON/Dark ON accordance with button setting
Control output
Self-diagnosis output
Protection circuitReverse power polarity, short-circuit(overcurrent) protection circuit
IndicatorOperation indicator : Red LED, Stability indicator : Green LED ON when the target stays in stable sensing level
Input of stop
transmission function
External synchroniza-
tion function
Remote sensitivity
setting function
Interference
prevention function
Timer function
(selectable)
Ambient illumination Sunlight : Max. 11,000㏓, Incandescent lamp : Max. 3,000
Noise resistance±240V the square wave noise(pulse width : 1㎲) by the noise simulator
Dielectric strength1,000VAC 50/60Hz for 1 minute
Insulation resistance Min. 20MΩ(at 500VDC megger)
Vibration1.5mm amplitude or 300m/s
Shock500m/s²(approx. 50G) in each of X, Y, Z directions for 3 times
Ambient
illumination
Environ-
Ambient
ment
temperature
Ambient
humidity
MaterialCase : Heat-resistance ABS, Cover : PC
Cable
AccessoryMounting bracket, Bolts/nuts
Approval
Unit weightApprox. 65g
※
1: Frequency 1(Normal mode) : Max. 0.5ms, Frequency 2 : Max. 0.7ms
※
The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.
● Residual voltage - NPN: Max. 1V(load current: 100mA), Max. 0.4V(load current:16mA) / PNP: Max. 2.5V
ON state under unstable sensing(When the target stays for 300ms in unstable area),
Cancellation of interference
protection function
(Normal mode)
Press [ON], [OFF] buttons
at the same time
STAB indicator flashes one time when the
difference of sensitivity between ON and OFF
(Normal mode, Response
time : Max. 0.5ms)
is enough, but STAB indicator flashes
5 times when the difference is not enough
Set the mode selection switch to LOCK (Completes setting)
Sensitivity adjustment
Adjustment by the sensitivity setting button(Common)
● Light ON
The control output turns on at Light ON status and turns off
at Light OFF status.
OrderSetting method
Mount the ber optic cable within sensing distance.
①
Change the mode selection switch to [SET].
②
Diffuse reective: Press [ON] button with a sensing target.
Transmitted beam: Press [ON] button without a sensing target.
<Transmitted beam>
③
Light ON
Stability indicator ashes at ON state.
④
(Check the target position)
Diffuse reective: Press [OFF] button without a sensing target.
Transmitted beam: Press [OFF] button with a sensing target.
<Transmitted beam>
⑤
Light ON
• When there is enough sensitivity difference between ON state
and OFF state, the STAB indicator ashes one time only at
stable sensing level.
⑥
• When there is not enough sensitivity difference between ON
state and OFF state, the STAB indicator ashes ve times at
unstable sensing level.
Change the mode selection switch to [LOCK], even
though the sensitivity setting button is touched,
⑦
setting sensitivity shall not be changed.
※
1. The sensitivity can be set at unstable sensing area.
※
When the power is OFF, the set sensitivity is saved.
※
After completing sensitivity setting, do not move or bend ber cable.
It may not detect it properly.
<Diffuse reflective >
(Low reflectance)
Light ON
<Diffuse reflective >
Mark (Low
reflectance)
Light ON
※
1
Mark
Background
(High
reflectance)
Background
(High
reflectance)
OUT
STAB
● Dark ON
The control output turns off at Light ON status and turns on
at Light OFF status.
<How to set sensitivity>
Most of adjustments except ③ & ⑤ are same as Light ON
mode.
state
- ③
Diffuse reective: Press [ON] button without a sensing target.
Through-beam: Press [ON] button with a sensing target.
state
- ⑤
Diffuse reective: Press [OFF] button with a sensing target.
Through-beam: Press [OFF] button without a sensing target.
SET
LOCK
STAB indicator turns off
<Transmitted beam>
Light ON
<Transmitted beam>
Light ON
Select the
frequency 1
Press [ON] button
(Frequency 1,
Response time
: Max. 0.5ms)
SET
LOCK
<Diffuse reflective >
Mark (Low
reflectance)
Light ON
<Diffuse reflective >
Mark (Low
reflectance)
Light ON
Setting of interference
protection function
(Differential frequency mode)
Select the
frequency 2
Press [OFF] button
(Frequency 2,
Response time
: Max. 0.7ms)
Background
(High
reflectance)
Background
(High
reflectance)
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
B-33
BF4 Series
To set as max. sensitivity(Common)
① Execute the general sensitivity setting.
Set the mode selection switch to [SET] mode.
②
If there is no sensing target,
③
- Light ON: Press the [ON → OFF] button
- Dark ON: Press the [OFF → ON] button
the mode selection switch to [LOCK] mode.
④ Set
※
External sensitivity setting
- Light ON(From above ③)
External sensitivity setting ON input(High→Low→High)
External sensitivity setting OFF input (High→Low→High)
- Dark ON Mode(From above ③)
External sensitivity setting OFF input(High→Low→High)
External sensitivity setting ON input(High→Low→High)
< Application >
● To extend sensing distance by the diffuse reective type:
If ber optic sensor is used in place where there are
targets with high reectivity and low reectivity, it is able
to get stable detection by adjusting max. sensitivity.
● When it is used as transmitted beam type at bad
environment :
If ber optic sensor is used in place where there is lots of
dust or moisture, it might cause malfunction.
Please max. sensitivity then it can perform stable
detection.
Remote sensitivity adjustment[BF4R(G)-R]
BF4R-R/BF4G-R type can adjust the sensitivity with input
signal lines regardless of the mode selection switch as
following diagram ;
(Brown) +V
(Black) Control output
(White) Self-diagnosis output
(Pink)ON input of remote sensitivity setting
(Orange)OFF input of remote
sensitivity setting
(Blue)0V
Adjustment at Light ON
①
● ON input of remote sensitivity setting(SW1) :
SW1 turns on and then turns off instead of ③ state of
adjustment by the sensitivity setting button.
● OFF input of remote sensitivity setting(
SW2 turns on and then turns off instead of ⑤ state of
adjustment by the sensitivity setting button.
Adjustment at Dark ON
②
● OFF input of remote sensitivity setting(SW2) :
SW2 turns on and then turns off instead of ③ state of
adjustment by the sensitivity setting button.
● ON input of remote sensitivity setting(
SW1 turns on and then turns off instead of ⑤ state of
adjustment by the sensitivity setting button.
<External sensitivity setting input signal condition>
StateSignal condition
High4.5-30VDC or Open
Low0-1VDC
*Input impedance:10kΩ
S/W2S/W1
) :
SW2
) :
SW1
Prohibition of inputting External
sensitivity setting[BF4R(G)-R]
Even though mode switch is at Lock position, it is able to
input external sensitivity setting when Switch1 and Switch 2
are ON. Therefore please install Switch3 in order to prevent
from malfunction as below.
※
SW3 - OFF : Disable to set external sensitivity
※
SW3 - ON : Enable to set external sensitivity
(Brown) +V
(Black) Control output
(White) Self-diagnosis output
(Pink)ON input of remote sensitivity setting
(Orange)OFF input of remote
sensitivity setting
(Blue)0V
Switch for prohibiting sensitivity setting
S/W3
W2 S/W1
S
/
Answer Back function[BF4R(G)-R]
When ON or OFF input of remote sensitivity setting is
applied, after 300ms, self-diagnosis output turns on for
40ms and then the sensor keeps normal sensing state.
(Note: Time chart)
※
Self-diagnosis output does not turn on if there is no
difference of sensitivity between ON input and OFF input
and stable sensing is not executed, but stable sensing
operates after 340ms.
<Time Chart : Light ON mode >
Power
supply
Remote
sensitivity
setting
ON input
Remote
sensitivity
setting
OFF input
Self-
diagnosis
output
(Answer
back
function)
Sensing
output
※
During period T3(Approx. 300ms), do not change the
light ON value by moving the object, etc.
1. T1≥1,000ms (After power turns on, it can be set after
1sec.)
2. T2≥5ms (ON or OFF input time of remote sensitivity
setting must be min. 5ms)
3. T3≒300ms (When ON or OFF input of remote sensitivity
setting is applied, self-diagnosis output turns on after
300ms)
4. T4≒40ms (ON time of self-diagnosis output)
5. T5≥500ms (When ON input of remote sensitivity setting
is applied and then apply OFF input of remote sensitivity
setting after 500ms)
ON
OFF
High
(OFF)
Low
(ON)
High
(OFF)
Low
(ON)
ON
OFF
T1 T2
T5T2
T3
T4T4
T3
Detectable
B-34
Fiber Optic Amplier
OFF Delay timer function
(BF4R/BF4RP/BF4R-R/BF4G/BF4GP/BF4G-R)
Standard type and Remote sensitivity setting type both
contain a built-in approx. 40ms fixed OFF Delay timer. The
timer works when the timer selection switch is set to 'OFD'.
The output is turned off after remaining on for additional
40ms at OFF position of the sensing output. It is useful
when the response time of the connected device is slow or
when the sensing signal from a tiny object is too short.
<Time Chart>
Sensing
Sensing
state
Light
ON
Dark
Normal
ON
Light
ON
Timer
Dark
ON
NonSensing
Output
operation
ON
OFF
ON
OFF
ON
OFF
ON
OFF
TTT
T
T≒40
Timer
selection
switch
㎳
External synchronization input
function [BF4R(G)-E]
By using external synchronization function, the time
for making sensing can be specified by external
synchronization. Trigger synchronization and gate
synchronization are available.
Trigger synchronizationGate synchronization
(Note)
Sensing
signal
External
synchroni-
zation
input
Control
output
External
synchroni-
zation
selection
switch
ON
OFF
High
Low
Approx. 40ms
ON
OFF
※
Control output is fixed
as 40ms.
TRIG
TT
ON
OFF
High
Low
ON
OFF
GATE
Stop transmission function
[BF4R(G)-E]-Operation test
● Below test is available under Light ON state only.
● If input of stop transmission is at Low state, transmission
light will be stopped.
● It can check normal or abnormal state of the sensor
without moving the target.
(Orange)Input of stop transmission
High or
Open
(Blue)0V
[If input of stop transmission is at High or Open state,
light is transmitted.]
(Orange)Input of stop transmission
Low
(Blue)0V
[If input of stop transmission is at Low, light is transmitted.]
Input of stop
transmission
Sensing output
(If it is in ON
state when light
High
(OFF)
Low
(ON)
ON
OFF
is not received)
※
: Transmission area, ②: Stop transmission area
①
※
(Note1) If transmission is stopped control output must
turn on, but if control output does not turn on,
it seems that sensor has some problems.
※
.5ms
T≥0
(When using interference prevention function T≥0.7ms)
<Input signal condition for Stop transmission>
StateSignal condition
High4.5-30VDC or Open
Low0-1VDC
<Input signal condition for External synchronization>
StateSignal condition
High4.5-30VDC or Open
Low0-1VDC
B-35
(T)
Software
(U)
Other
BF4 Series
Self-diagnosis function(Common)
When fiber hood is contaminated by dust, transmitted
light is lowered by element ability loss or received light is
lowered by missing of optical axis, the self-diagnosis output
will turn on.
※
Light ON mode
Move to
unstable level
Unstable
operation
level
Stability
indicator
Control
output
indicator
(OUT)
Self-diagnosis
output(Alarm)
The self-diagnosis output turns off during stable
①
Light ON
incomplete
300
unstable level
㎳
②
Out of
①①
detection.(① position)
detecting state remains for 300ms at unstable
② When
level between stable light OFF level and stable light
ON level, self diagnosis output turns on, self-diagnosis
output turns off at lower than stable light OFF level and
upper than stable light ON level. (② position)
the control output turns on, if an overcurrent
③ When
condition exists in control output, then self-diagnosis
output turns on.
Move to
unstable level
Light OFF
incomplete
300
㎳
②
Move to
unstable level
Stable light
ON level
Control output
operation
level
Stable light
off level
ON
OFF
Light ON
Light OFF
ON
OFF
Interference prevention function
(Common)
BF4R series has interference prevention function, two
fiber optic cables can be mounted very closely by setting
different transmission frequencies.
●Interference prevention function
(Operation of differential frequency mode)
First sensor- Frequency 1(Response time: max. 0.5ms)
Set the mode selection switch to [SET].
①
Press the [ON] & [OFF] buttons for
②
2sec. at the same time.
The [STAB] indicator flashes continuously.
③
Press the [ON] button.
④
The [STAB] indicator turns off.
⑤
OUT
STAB
Flashing
⑥
Set the mode selection switch to [LOCK].
Second sensor- Frequency 2(Response time: max. 0.7ms)
Set the mode selection switch to [SET].
①
Press the [ON] & [OFF] buttons for
②
2sec. at the same time.
The [STAB] indicator flashes continuously.
③
Press the [OFF] button.
④
The [STAB] indicator turns off.
⑤
OUT
STAB
Light off
B-36
OUT
STAB
FlashingLight off
⑥
Set the mode selection switch to [LOCK].
OUT
STAB
● Interference prevention function
(Operation of normal mode)
Set the mode selection switch to [SET].
①
Press the [ON] & [OFF] buttons for 2 sec. at the same
②
time.
The stable indicator flashes continuously.
③
Press the [ON] & [OFF] buttons at the same time.
④
[STAB] indicator turns off.
⑤The
the mode selection switch to [LOCK].
⑥Set
※
When interference prevention function is used,
hysteresis & response time will be longer than normal
operation(Response time : Max. 0.5ms).