Autonics AT8PSN Series, AT8PMN Series Catalog Page

AT8PSN/AT8PMN Series
DIN W48×H48mm Solid-State, Power OFF Delay Timer
Features
● Time setting range (AT8PSN: 0.05 to 10 sec, AT8PMN: 0.05 to 10 min)
● Power supply : 100-120VAC 50/60Hz, 200-240VAC 50/60Hz 100/110VDC, 24VAC 50/60Hz, 24VDC universal
● Application: Protect circuit when momentary power failure and start it again
Please read “Safety Considerations” in the instruction manual before using.
Ordering Information
AT 8 P SN
-rL____-----+----+------------j
Power supply
Time unit
Time opera ion
Number of plug pins
Item
Specications
Model AT8PSN-
Function Power OFF Delay
Control time setting range
Power supply
Allowable voltage range 90 to 110% of rated voltage
Power consumption
Timing operation Power OFF start
Control output
Relay life cycle
Repeat error Max. ±0.2% ±10ms
SET error Max. ±5% ±50ms
Voltage error Max. ±0.5%
Temperature error Max. ±2%
Insulation resistance Over 100MΩ (at 500VDC megger)
Dielectric strength 2,000VAC 50/60Hz for 1 min
Noise immunity ±2kV the square wave noise (pulse width: 1㎲) by he noise simulator
Vibra ion
Shock
Environment
Approval
Accessory Bracket
Unit weight Approx. 100g
※ ※
Contact type Time limit DPDT (2c)
Contact capacity 250VACᜠ 3A, 30VDCᜡ 3A resistive load
Mechanical Min.10,000,000 operations
Electrical Min. 100,000 operations (250VAC 3A resistive load)
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
Mechanical 300m/s² (approx. 30G) in each X, Y
Malfunction 100m/s² (approx. 10G) in each X, Y, Z direction 3 times
Ambient temperature
I
Ambient humidity 35 to 85%RH
I
1: Refer to time specications for control time setting range. Environment resistance is rated at no freezing or condensation.
1
0.05 to 10 sec 0.05 to 10 min
• 100-120VACᜠ 50/60Hz • 200-240VACᜠ 50/60Hz
• 100/110VDCᜡ
• Max. 1.5VA (100-120VACᜠ) • Max. 1 5VA (200-240VACᜠ)
• Max. 0.8W (100/110VDCᜡ) • Max. 2VA (24VACᜠ), Max. 2W (24VDCᜡ)
-10 to 55℃, storage: -25 to 65
ᜢ ᜧ
AT8PMN-
( €
No mark 200-240VAC 50/60Hz
2 24VAC 50/60Hz, 24VDC
6 100-120VAC 50/60Hz
7 100/110VDC
SN SEC
MN MIN
P Power OFF Delay
8 8-pin plug type
AT Analog Timer
c'i\lus
8-pin socket (PG-08, PS-08(N)) is sold separately.
I
I
• 24VACᜠ 50/60Hz, 24VDCᜡ universal
, Z direction 3 times
N-74
Autonics
Connections
CONTACT OUT: 250VAC 3A, 30VDC 3A RESISTIVE LOAD
a
(Time limit 1c) (Time limit 1c)
Power OFF Delay Analog Timer
4
5
3
b
2
1
-
6
a
7
8
+
SOURCE:
• 100-120VAC 50/60Hz • 200-240VAC 50/60
• 24VAC 50/60Hz, 24VDC • 100/110VDC
CONTACT OUT: 250VAC 3A,
b
30VDC 3A RESISTIVE LOAD
Hz
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
Dimensions
48 6.5
~
5014.9 14.7
44.8
■ I □
0 0
30 5
36
~
44.9
45
48.6
'
55
[[l
56
Panel cut-out Bracket
Min. 65
Min. 65
EE
+0.6
45
0
(unit: mm)
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
Unit Description
Power ON indicator
Time range
display
Time range
selector
Output reset indicator
Time unit
(SEC, MIN)
Autonics
● Time specications
Model Time range Time unit Time setting range
AT8PSN-
AT8PMN-
0.5 1 0 to 1 sec
5 0 to 5 sec 10 0 to 10 sec
0.5 1 0 to 1 min
5 0 to 5 min 10 0 to 10 min
SEC
MIN
0 to 0.5 sec
0 to 0.5 min
N-75
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
AT8PSN/AT8PMN Series
Output Operation Mode
Contact a turns ON when the power applied and then turns o󰀨 after setting time (T) is passed when the power o󰀨. There is memory protection function. Even though changing setting time after cutting the power, time limit a contact turns OFF after the setting time before cutting the power.
T
②-⑦
Power
Time limit a contact
Time limit b contact
Power LED operation
Up LED operation
Proper Usage
Follow instructions in ‘Proper Usage’. Otherwise, it may cause unexpected accidents.
24VDC, 24VAC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
Supply power for over 0.1 sec for AT8PSN- and 2 sec for AT8PMN- .
Since AT8PSN/PMN are Power O󰀨 Delay timer, they operate after turning of the power.
When supplying or turning o󰀨 the power, use a switch or etc. to avoid chattering.
Install a power switch or circuit breaker in the easily access ble place for supplying or disconnecting the power.
Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line lter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise. Change setting time(T1) or etc. after turning o󰀨 the power of the timer.
This product may be used in the following environments.
Indoors (in the environment condition rated in ‘Specications’)
Altitude max. 2,000m
Pollution degree 2
Installation category II
⑧-⑥ ①-③
⑧-⑤ ①-④
T: Setting time
N-76
Autonics