DRW180083AC
Slim Remote I/O [Coupler]
ARIO-C SERIES
I N S T R U C T I O N M A N U A L
Thank you very much for selecting Autonics products.
For your safety, please read the following before using.
Safety Considerations
▣
Please observe all safety considerations for safe and proper product operation to
※
avoid hazards.
symbol represents caution due to special circumstances in which hazards may occur.
※
Warning
Failure to follow these instructions may result in serious injury or death.
Caution
Failure to follow these instructions may result in personal injury or product damage.
Warning
1. Fail-safe device must be installed when using the unit with machinery that
may cause serious injury or substantial economic loss. (e.g. nuclear power
control, medical equipment, ships, vehicles, railways, aircraft, combustion
apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal injury, re or economic loss.
2. Do not use the unit in the place where ammable/explosive/corrosive gas,
high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may
be present.
Failure to follow this instruction may result in explosion or re.
3. Do not disassemble or modify the unit.
Failure to follow this instruction may result in re.
4. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in re.
5. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or shortening the life cycle of the
product.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in re or electric shock.
3. When connecting the power input and output, use AWG 22-16 cable and
check the connecting method of crimp terminal.
Failure to follow this instruction may result in re or malfunction due to contact
failure.
4. Keep metal chip, dust, and wire residue from owing into the unit.
Failure to follow this instruction may result in re or product damage.
5. Do not connect or disconnect connector (terminal) wire or power, when the
product is operating.
Failure to follow this instruction may result in re or malfunction of the product.
It may be different depending on the coupler model.
Unit Descriptions
▣
1
2
The above specications are subject to change and some models may be
※
discontinued without notice.
Be sure to follow cautions written in the instruction manual, user manual and
※
the technical descriptions (catalog, website).
3
※
4
6
1. Communication connector
2. Communication setting switch
3. Setting connector (USB 2.0 type Micro B)
5
4. Indicators for power and comm. status
5. Power terminal block
6. ABUS comm. connector
6
Specications
▣
Model ARIO-C-EC ARIO-C-CL ARIO-C-PN ARIO-C-PB ARIO-C-EI ARIO-C-DN ARIO-C-MT ARIO-C-MR
Coupler type EtherCAT CC-Link ProNet ProBus Ethernet/IP DeviceNet
AB US(external consump.)
Power
supply
ABUS(internal supply)
1
※
I/O 24VDCᜡ, max. 4,000mA (max. 96W, max. 2,000mA/CH, 2CH/COM)
Power
consumption
Comm. speed 100Mbps 10Mbps 100Mbps 12Mbps 10/100Mbps 500kbps 10/100Mbps 115.2kbps
Memory
Max. connections for modules
Comm. connector
Installation method DIN rail mounting
Setting and monitoring PC connection with USB 2.0 Micro type connector (comprehensive device management program, DAQMaster)
Insulation resistance Over 100MΩ (at 500VDCᜡ megger)
Environment
Protection structure
Material Terminal: polyamide6, Body: modied polyphenylene oxide, Base: polyamide6, poly oxy methylene
Approval
Weight
※
※
※
▣
● Coupler
▣
Connecting
Removing
1) Press and hold the catch above the terminal in direction ② with
2) Pull and remove the wire towards direction ③.
※
Coupler 24VDCᜡ standby/run: 200mA, max. load: 400mA (coupler max. load)
Input 512 byte 256 byte 512 byte 244 byte 504 byte 255 byte 512 byte 256 byte
2
※
Output 512 byte 256 byte 512 byte 244 byte 504 byte 255 byte 512 byte 256 byte
Ambient temp. -10 to 55
Ambient humi. 35 to 85%RH,
4
※
1. It is for including power/special modules and excluding coupler/end modules. In case of one coupler module connecting, the ARIO digital module is available to connect up to 8 units
and the ARIO analog module is available to connect up to 4 units. For connecting the modules, consider power consumption of the sensors and drivers connected the ARIO coupler.
2. If it is over the limit size or connected units, system may be error. ※3. Autonics test standard ※4. The weight includes packaging. The weight in parenthesis is for unit only.
Environment resistance is rated at no freezing or condensation.
Dimensions
34
A
52.4
50 70
Connecting & Removing Wires
Push the wire connected with the crimp terminal towards
direction ① to complete the connection.
a non-conductive flat head screwdriver (width max. 3mm).
Use the UL certied End Sleeve (Ferrule Terminal) crimp terminals and wire.
Use the copper-conductor wire with the temperature class 60℃.
a
b
<Crimp terminal>
24VDCᜡ, max. 400mA (max. 9.6W, coupler+module, max. 200mA/CH, 2CH/COM)
5VDCᜡ, max. 960mA (max. 4.8W, module)
2
※
64 units 32 units 64 units 32 units 64 units 32 units 64 units 32 units
3
※
RJ45 connectors: 2
IP20 (IEC standards)
℃,storage:
storage:
5-pin PCB connector
-25 to 70
℃
35 to 85%RH
RJ45 connectors: 2
9-pin D SUB connector
RJ45 connectors: 2
5-pin PCB connector
Approx. 265g (approx. 165g)
Manuals
▣
For the detail information and instructions, you must refer to the each manual,
and be sure to follow cautions written in the technical descriptions (catalog, website).
Visit our website (www.autonics.com) to download manuals.
Comprehensive Device Management program [DAQMaster]
▣
DAQMaster is a comprehensive device management software for setting parameters
and monitoring processes. DAQMaster can be downloaded from our website at
www.autonics.com.
Caution during Use
▣
1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected
accidents.
2. ABUS power and I/O power should be insulated by the individually insulated power
device.
3. Power supply should be insulated and limited voltage/current or Class 2, SELV
power supply device.
4. Use the rated standard cables and connectors. Do not apply excessive power when
connecting or disconnecting the connectors of the product.
5. Keep away from high voltage lines or power lines to prevent inductive noise. In case
installing power line and input signal line closely, use line lter or varistor at power
line and shielded wire at input signal line.
For stable operation, use shield wire and ferrite core, when wiring communication
wire, power wire, or signal wire. Do not use near the equipment which generates
strong magnetic force or high frequency noise.
6. Do not touch the module communication connector part of the base.
7. Do not connect, or remove the base while connected to a power source. For
removing the terminal, body or base, do not operate units for a long time without it
8. This unit may be used in the following environments.
①Indoors
③Pollution degree 2
Major Products
▣
Photoelectric Sensors Temperature Controllers
Fiber Optic Sensors Temperature/Humidity Transducers
Door Sensors SSRs/Power Controllers
Door Side Sensors Counters
Area Sensors Timers
Proximity Sensors Panel Meters
Pressure Sensors Tachometer/Pulse (Rate) Meters
Rotary Encoders Display Units
Connector/Sockets Sensor Controllers
Switching Mode Power Supplies
Control Switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper Motors/Drivers/Motion Controllers
Graphic/Logic Panels
Field Network Devices
Laser Marking System (Fiber, Co₂, Nd:yag)
Laser Welding/Cutting System
Model Asize
ARIO-C-
EC/EI/PN/MT
ARIO-C-
DN/CL/MR
ARIO-C-PB 38.2
100
a b c
c
Range 8 to 12mm
Recommended
10mm 1mm AWG18
39
36.2
BaseTerminal Body
Max. 3mm
● End module
5
①
③
0.6 to 1.3mm
(unit: mm)
98.4
②
Certied
spec.
AWG22-16
33
ModbusTCP
compatible
RJ45 connectors: 2
Altitude max. 2,000m
②
Installation category II)
④
http://www.autonics.com
HEADQUARTERS:
18, Bansong-ro 513beon-gil, Haeundae-gu,
Busan, South Korea, 48002
TEL: 82-51-519-3232
E-mail: sales@autonics.com
ModbusRTU
compatible
5-pin PCB connector
DRW180083AC
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com