Autonics ARIO-C-MT, ARIO-C-MR User manual

DRW180083AC
Slim Remote I/O [Coupler]
ARIO-C SERIES
I N S T R U C T I O N M A N U A L
Thank you very much for selecting Autonics products.
For your safety, please read the following before using.

Safety Considerations

Please observe all safety considerations for safe and proper product operation to
avoid hazards.
symbol represents caution due to special circumstances in which hazards may occur.
Warning
Failure to follow these instructions may result in serious injury or death.
Caution
Failure to follow these instructions may result in personal injury or product damage.
Warning
Failure to follow this instruction may result in personal injury, re or economic loss.
2. Do not use the unit in the place where ammable/explosive/corrosive gas,
high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in explosion or re.
3. Do not disassemble or modify the unit.
Failure to follow this instruction may result in re.
4. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in re.
5. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or shortening the life cycle of the
product.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in re or electric shock.
3. When connecting the power input and output, use AWG 22-16 cable and
check the connecting method of crimp terminal.
Failure to follow this instruction may result in re or malfunction due to contact
failure.
4. Keep metal chip, dust, and wire residue from owing into the unit.
Failure to follow this instruction may result in re or product damage.
5. Do not connect or disconnect connector (terminal) wire or power, when the
product is operating.
Failure to follow this instruction may result in re or malfunction of the product.
It may be different depending on the coupler model.

Unit Descriptions

1
2
The above specications are subject to change and some models may be
※
discontinued without notice. Be sure to follow cautions written in the instruction manual, user manual and
※
the technical descriptions (catalog, website).
3
4
6
1. Communication connector
2. Communication setting switch
3. Setting connector (USB 2.0 type Micro B)
5
4. Indicators for power and comm. status
5. Power terminal block
6. ABUS comm. connector
6
Specications
Model ARIO-C-EC ARIO-C-CL ARIO-C-PN ARIO-C-PB ARIO-C-EI ARIO-C-DN ARIO-C-MT ARIO-C-MR
Coupler type EtherCAT CC-Link ProNet ProBus Ethernet/IP DeviceNet
AB US(external consump.)
Power supply
ABUS(internal supply)
1
I/O 24VDCᜡ, max. 4,000mA (max. 96W, max. 2,000mA/CH, 2CH/COM) Power consumption Comm. speed 100Mbps 10Mbps 100Mbps 12Mbps 10/100Mbps 500kbps 10/100Mbps 115.2kbps
Memory
Max. connections for modules Comm. connector Installation method DIN rail mounting Setting and monitoring PC connection with USB 2.0 Micro type connector (comprehensive device management program, DAQMaster) Insulation resistance Over 100MΩ (at 500VDCᜡ megger)
Environment
Protection structure Material Terminal: polyamide6, Body: modied polyphenylene oxide, Base: polyamide6, poly oxy methylene
Approval
Weight
※ ※
● Coupler
Connecting
Removing
1) Press and hold the catch above the terminal in direction ② with
2) Pull and remove the wire towards direction ③.
※
Coupler 24VDCᜡ standby/run: 200mA, max. load: 400mA (coupler max. load)
Input 512 byte 256 byte 512 byte 244 byte 504 byte 255 byte 512 byte 256 byte
2
Output 512 byte 256 byte 512 byte 244 byte 504 byte 255 byte 512 byte 256 byte
Ambient temp. -10 to 55 Ambient humi. 35 to 85%RH,
4
1. It is for including power/special modules and excluding coupler/end modules. In case of one coupler module connecting, the ARIO digital module is available to connect up to 8 units and the ARIO analog module is available to connect up to 4 units. For connecting the modules, consider power consumption of the sensors and drivers connected the ARIO coupler.
2. If it is over the limit size or connected units, system may be error. ※3. Autonics test standard ※4. The weight includes packaging. The weight in parenthesis is for unit only.
Environment resistance is rated at no freezing or condensation.

Dimensions

34
A
52.4 50 70

Connecting & Removing Wires

Push the wire connected with the crimp terminal towards direction ① to complete the connection.
a non-conductive flat head screwdriver (width max. 3mm).
Use the UL certied End Sleeve (Ferrule Terminal) crimp terminals and wire. Use the copper-conductor wire with the temperature class 60℃.
a
b
<Crimp terminal>
24VDCᜡ, max. 400mA (max. 9.6W, coupler+module, max. 200mA/CH, 2CH/COM) 5VDCᜡ, max. 960mA (max. 4.8W, module)
2
64 units 32 units 64 units 32 units 64 units 32 units 64 units 32 units
3
RJ45 connectors: 2
IP20 (IEC standards)
℃,storage:
storage:
5-pin PCB connector
-25 to 70
35 to 85%RH
RJ45 connectors: 2
9-pin D SUB connector
RJ45 connectors: 2
5-pin PCB connector
Approx. 265g (approx. 165g)

Manuals

For the detail information and instructions, you must refer to the each manual, and be sure to follow cautions written in the technical descriptions (catalog, website). Visit our website (www.autonics.com) to download manuals.

Comprehensive Device Management program [DAQMaster]

DAQMaster is a comprehensive device management software for setting parameters and monitoring processes. DAQMaster can be downloaded from our website at www.autonics.com.

Caution during Use

1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents.
2. ABUS power and I/O power should be insulated by the individually insulated power device.
3. Power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
4. Use the rated standard cables and connectors. Do not apply excessive power when connecting or disconnecting the connectors of the product.
5. Keep away from high voltage lines or power lines to prevent inductive noise. In case
installing power line and input signal line closely, use line lter or varistor at power
line and shielded wire at input signal line. For stable operation, use shield wire and ferrite core, when wiring communication wire, power wire, or signal wire. Do not use near the equipment which generates strong magnetic force or high frequency noise.
6. Do not touch the module communication connector part of the base.
7. Do not connect, or remove the base while connected to a power source. For removing the terminal, body or base, do not operate units for a long time without it
8. This unit may be used in the following environments.
①Indoors ③Pollution degree 2

Major Products

Photoelectric Sensors Temperature Controllers Fiber Optic Sensors Temperature/Humidity Transducers Door Sensors SSRs/Power Controllers Door Side Sensors Counters Area Sensors Timers Proximity Sensors Panel Meters Pressure Sensors Tachometer/Pulse (Rate) Meters Rotary Encoders Display Units Connector/Sockets Sensor Controllers Switching Mode Power Supplies Control Switches/Lamps/Buzzers I/O Terminal Blocks & Cables Stepper Motors/Drivers/Motion Controllers Graphic/Logic Panels Field Network Devices Laser Marking System (Fiber, Co₂, Nd:yag) Laser Welding/Cutting System
Model Asize
ARIO-C- EC/EI/PN/MT
ARIO-C- DN/CL/MR
ARIO-C-PB 38.2
100
a b c
c
Range 8 to 12mm Recommended
10mm 1mm AWG18
39
36.2
BaseTerminal Body
Max. 3mm
● End module
5
0.6 to 1.3mm
(unit: mm)
98.4
Certied spec. AWG22-16
33
ModbusTCP compatible
RJ45 connectors: 2
Altitude max. 2,000m
Installation category II)
http://www.autonics.com
HEADQUARTERS:
18, Bansong-ro 513beon-gil, Haeundae-gu, Busan, South Korea, 48002 TEL: 82-51-519-3232
E-mail: sales@autonics.com
ModbusRTU compatible
5-pin PCB connector
DRW180083AC
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Loading...