Features
Automatic communication speed recognition
: Enables to recognize communication speed automatically
when connecting with master
Network Voltage monitoring
: If PV is lower than SV, enables to receive error flag for
network power monitoring as Explicit message.
Additional expansion units
- Standard terminal block type: Connectable up to 3 expansion units
- Sensor connector type: Connectable up to 7 expansion units
- Expandable I/O points up to max. 64 points for Standard terminal
type, sensor connector type
Reading the number of expansion units
: Reads the number of connected expansion units Reading model name: Reads the connected model name
of connected units (sensor connector type) Reading the unit specifications: Reads the specifications of
connected units
Please read “Safety Considerations” in the instruction manual before using.
Ordering Information
AR D D I 08 A E 4S
Terminal
2
block
Structure
I/O specification
1
I/O point
I/O type
Digital/Analog
Network
Item
1: Sensor connector type (ARD- -4S) model is only for NPN, PNP I/O specications.
2: Sensor connector (CNE-P04- ) is sold separately.
3: It is only for an expansion unit of sensor connector type.
5: For analog type, refer to '
ARD-A Series
'.
No-mark Standard terminal block type 4S Sensor connector type (4-pin socket)
No-mark Basic unit
4
E
Expansion unit
A AC voltage R Relay N NPN open collector S SSR P PNP open collector
08 8 points type 16 16 points type
I Input type O Output type X I/O mixed type
D Digital type
5
A
D Basic unit (DeviceNet)
X
Analog type
3
Expansion unit (DeviceNet/Modbus)
AR Autonics Remote I/O
ARD-D Series
Standard terminal block type
Sensor connector type
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
X-15
ARD-D Series
Models
Models Terminal type Basic unit Expansion unit
Standard terminal block
type
Sensor connector type
ARD-DI08A ARD-DI08AE 75-250VAC input 8-point (13mA/point) ARD-DI16N ARD-DI16NE 10-28VDC NPN input 16-point (10mA/point) ARD-DI16P ARD-DI16PE 10-28VDC PNP input 16-point (10mA/point) ARD-DO08R ARD-DO08RE Relay output 8-point (2A/point), Life cycle of contact: 100,000 times ARD-DO08S ARD-DO08SE SSR output 8-point (1A/point) ARD-DO16N ARD-DO16NE 10-28VDC NPN output 16-point (0.5A/point) ARD-DO16P ARD-DO16PE 10-28VDC PNP output 16-point (0.5A/point) ARD-DX16N ARD-DX16NE 10-28VDC NPN input 8-point (10mA/point), NPN output 8-point (0.5A/point) ARD-DX16P ARD-DX16PE 10-28VDC PNP input 8-point (10mA/point), PNP output 8-point (0.5A/point) ARD-DI08N-4S ARX-DI08N-4S 10-28VDC NPN input 8-point (10mA/point) ARD-DI08P-4S ARX-DI08P-4S 10-28VDC PNP input 8-point (10mA/point) ARD-DO08N-4S ARX-DO08N-4S 10-28VDC NPN output 8-point (0.3A/point) ARD-DO08P-4S ARX-DO08P-4S 10-28VDC PNP output 8-point (0.3A/point)
Specifications
Standard terminal block type
Basic
Model
Power supply Rated voltage: 24VDCᜡ, Voltage range: 12-28VDC Power consumption Max. 3W
I/O points
Control I/O
Insulation resistance Over 200MΩ (at 500VDC megger) Noise immunity ±240V the square wave noise (pulse width: 1㎲) by the noise simulator Dielectric strength 1,000VAC 50/60 Hz for 1 min Vibration 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours Shock 500m/s2 (approx. 50G) in each X, Y, Z direction for 3 times
Environ-
ment
Protection structure IP20 (IEC standard)
Protection circuit
Indicator
Material Front case, body case: Polycarbonate, Rubber cap: acrylonitrile-butadiene rubber Mounting DIN rail or bolt mounting type
Approval
Unit weight
Environment resistance is rated at no freezing or condensation.
unit Expansion
unit
Voltage
Current 13mA/point 10mA/point 1A/point
COMMON
method
Ambient temp. -10 to 50℃, storage: -25 to 75 Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
ARD­DI08A
ARD­DI08AE
AC input
8-point
75­250VAC
8-point, common
Surge protection circuit, reverse polarity protection circuit (common)
●Transistor output type - Overcurrent protection circuit (NPN type: operated at min. 1.9A → re-supply power in
Network status (NS) LED (green, red), unit status (MS) LED (green, red), I/O status LED (input: green, output: red)
Approx. 150g
ARD­DI16N
ARD­DI16NE
NPN input
16-point
10-28VDC
Approx. 140g
ARD­DI16P
ARD­DI16PE
PNP input
16-point
overcurrent status, PNP type: operated at min. 0.7A), Overheat protection circuit (over 165℃), Short-circuit protection circuit
Specication
ARD­DO08R
ARD­DO08RE
Relay output
8-point
Normally open (N.O.) 250VACᜠ 2A 1a
1-point,
COM
Approx. 160g
ARD­DO08S
ARD­DO08SE
SSR output
8-point
30-
250VAC
8-point, common
Approx. 170g
ARD­DO16N
ARD­DO16NE
NPN
output
16-point
10-28VDCᜡ (voltage drop: max. 0.5VDCᜡ)
0.5A/point (leakage current: max.
0.5 mA)
Approx. 140g
ARD­DO16P
ARD­DO16PE
PNP
output
16-point
ARD­DX16N
ARD­DX16NE
NPN input
8-point
+ output
8-point
Input: 10mA, Output: 0.5A/point (leakage current: max.
0.5mA)
ARD­DX16P
ARD­DX16PE
PNP input
8-point
+ output
8-point
X-16
DeviceNet Digital Remote I/O
Specifications
Sensor connector type
Model
Basic unit
Expansion unit Power supply Rated voltage: 24VDCᜡ, Voltage range: 12-28VDC Power consumption Max. 3W I/O points NPN input 8-point PNP input 8-point NPN output 8-point PNP output 8-point
Voltage 10-28VDCᜡ input 10-28VDCᜡ output (voltage drop: max. 0.5VDCᜡ)
Control I/O
Current 10mA/point (sensor current: 150mA/point) 0.3A/point (leakage current: max. 0.5mA)
COMMON
method
Insulation resistance Over 200MΩ (at 500VDC megger) Noise immunity ±240V the square wave noise (pulse width: 1㎲) by the noise simulator Dielectric strength 1,000VAC 50/60Hz for 1 min (between external terminals and case) Vibration 1.5mm amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 2 hours Shock 500m/s2 (approx. 50 G) in each X, Y, Z direction for 3 times
Environ-
ment
Ambient temp. -10 to 50℃, storage: -25 to 75 Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
Protection structure IP20 (IEC standard)
Protection circuit
Indicator Material Front case, body case: Polycarbonate Mounting DIN rail or bolt mounting type
Approval
Unit
weight
Basic unit Approx. 64g Approx. 64g Approx. 65g Approx. 67g
Expansion unit Approx. 56g Approx. 57g Approx. 58g Approx. 59g
Environment resistance is rated at no freezing or condensation.
DeviceNet Communication
Item Specications
Communication
Communication distance Max. 500m (125kbps), Max. 250m (250kbps), Max. 100m (500kbps)
NODE ADDRESS setting Max. 64 nodes (set by the front rotary switch)
Communication speed※1125, 250, 500kbps (automatically set when connecting with Master)
Insulation
DeviceNet power
Approval ODVA Conformance tested
The communication speed is automatically set to the communication speed of the Master (PC, PLC, etc.) When changing the
※1.
communication speed during operation, the network status (NS) LED ashes in red and communication is not possible.
ARD-DI08N-4S ARD-DI08P-4S ARD-DO08N-4S ARD-DO08P-4S ARX-DI08N-4S ARX-DI08P-4S ARX-DO08N-4S ARX-DO08P-4S
8-point, common
Surge, short-circuit, overheat and ESD protection, reverse polarity protection circuit Overcurrent protection circuit (operated at min. 0.17A) Overcurrent protection circuit (operated at min. 0.7A) Network status (NS) LED (green, red), unit status (MS) LED (green, red), I/O status LED (input: green, output: red)
I/O Slave messaging (Group 2 Only slave)
·Poll command: Yes ·Bit_strobe command: Yes ·Cyclic command: Yes ·COS command: Yes
I/O and inner circuit: Photocoupler isolated, DeviceNet and inner circuit: non-isolated, DeviceNet power: non-isolated
· Rated voltage: 24VDCᜡ
· Voltage range: 12-28VDCᜡ
· Power consumption: max. 3W
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
Communication Distance
Baud rate Max. network length Max. branch line length Max. extended branch line length
125kbps 500m 6m 156m
250kbps 250m 6m 78m
500kbps 100m 6m 39m
X-17
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
ARD-D Series
Unit Description
Basic unit
● Standard terminal block type
2 3 4 5
1
7
● Sensor connector type
3
2
9
8
1
1. DeviceNet connector
No. Color For Organization
5 Red 24VDC (+)
6
4 White CAN_H
3 None Shield
2 Blue CAN_L
1 Black 24VDC (-)
V+ CAN_H
SHIELD
CAN_L V-
2. Rotary switch for node address
: Rotary switch for setting node address.
×10 represents tens digit and ×1 represents ones digit.
3. Status LED
4. I/O status LED
5. Rail lock
6
5
4
6. Connector output part
7. I/O terminal block
8. Sensor connector
9. External power connector
: It displays the status of unit (MS) and network (NS).
: It displays each I/O status.
: It is used for mounting DIN rail or with bolt.
: It connects an expansion unit.
: It is used for connecting external device I/O.
: It is used for connecting external device I/O.
: It is used for supplying external power.
Expansion unit
● Standard terminal block type
2
1
3
5
● Sensor connector type
3
4
7
1
2
6
Status LED
Item
Unit status (MS) LED
Network status (NS) LED
LED status
Red Green
4
1. Connector input part
: It connects expansion unit and is joined into
expansion connector output.
2. I/O status LED
3. Rail lock
4. Connector output part
5. I/O terminal block
6. Sensor connector
7. External power connector
Description
Unrecoverable error
Recoverable error & communication error of expansion unit
Normal operation
Power is not supplied
Normal standby
Network On-Line
Duplicate, MAC ID / Bus-O󰀨
Time Out
Network O󰀨-Line
: It displays each I/O status.
: It is used for mounting DIN rail or with bolt.
: It connects an expansion unit.
: It is used for connecting external device I/O.
: It is used for connecting external device I/O.
: It is used for supplying external power
( : ON, : Flash, : OFF)
X-18
DeviceNet Digital Remote I/O
I/O Circuit Diagram
Standard terminal block type
Type DeviceNet connector Inner circuit External connections
NPN input
PNP input
AC input
NPN output
PNP output
Relay output
SSR output
CAN_H
SHIELD
CAN_L
CAN_H
SHIELD
CAN_L
CAN_H
SHIELD
CAN_L
CAN_H
SHIELD
CAN_L
CAN_H
SHIELD
CAN_L
CAN_H
SHIELD
CAN_L
CAN_H
SHIELD
CAN_L
V+
V-
V+
V-
V+
Physical layer
DC-DC converter
Non-insulation
Physical layer
DC-DC converter
Non-insulation
Physical layer
Inner circuit
Inner circuit
Inner circuit
V-
DC-DC converter
Non-insulation
V+
Physical layer
Inner circuit
V-
DC-DC converter
Non-insulation
V+
Physical layer
Inner circuit
V-
DC-DC converter
Non-insulation
V+
V-
V+
V-
Physical layer
DC-DC converter
Non-insulation
Physical layer
DC-DC converter
Non-insulation
Inner circuit
Inner circuit
SSR
SSR
VDC
IN0
IN1
IN0
IN1
COM
VAC
IN0
IN1
COM
VDC
OUT0
OUT1
GND
VDC
OUT0
OUT1
GND
VAC
GND
OUT0
COM0
OUT1
COM1
VAC
OUT0
OUT1
COM1
Load
Load
Load
Load
Load
Load
Load
Load
+
10-28VDC
-
+
10-28VDC
-
75-250VAC
+
-
+
-
+
24VDC
-
10-28VDC
10-28VDC
15-250VAC
30-250VAC
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
X-19
ARD-D Series
I/O Circuit Diagram
Sensor connector type
Type Network connector Inner circuit Sensor connector
NPN
input
PNP
input
NPN
output
PNP
output
SHIELD
24VDC
GND
SHIELD
24VDC
GND
SHIELD
24VDC
GND
SHIELD
24VDC
GND
A
B
Inner circuit
A
B
Inner circuit
A
B
Inner circuit
A
B
Inner circuit
VDC
NC
GND
NC
VDC
NC
GND
IN0
VDC
NC
GND
IN1
VDC
NC
GND
IN0
VDC
NC
GND
IN1
VDC
NC
GND
NC
VDC
NC
GND
NC
VDC
NC NC OUT0
VDC
NC NC OUT1
VDC
NC
GND
NC
NC NC
GND
OUT0
NC NC
GND
OUT1
X-20
DeviceNet Digital Remote I/O
Connections
Standard terminal block type
When wiring the communication connector, use cable and tap which meet the DeviceNet standard and tighten the connector screw with a
tightening torque of 0.5N.m.
When wiring the input/output terminal, tighten the connector screw with a tightening torque of 0.5N.m.
● ARD-DI08A (E)
[AC input]
SENSORS
CONTROLLERS
MOTION DEVICES
● ARD-DI16N (E) ● ARD-DI16P (E)
V
IN0
IN1
IN2
IN3
IN5
IN3
IN7
DC
V
+ -
IN1
DC
● ARD-DO08R (E) ● ARD-DO08S (E)
V
N·C
OUT0
OUT1
COM0
COM1
Load
OUT2
COM2
DC
GND
N·C COM
+ -
● ARD-DO16N (E) ● ARD-DO16P (E)
V
OUT0
OUT2
OUT4
DC
GND
OUT1
­+
Load
● ARD-DX16N (E) ● ARD-DX16P (E)
V
IN0
DC
IN1
DC
+ -
OUT6
OUT3
OUT5
OUT7
[DC NPN input/DC NPN output]
IN2
IN4
IN6
IN3
IN5
IN7
[DC NPN input] [DC PNP input]
COM
IN0
IN2
IN4
IN6
IN5
IN7
COM
COM
IN8
IN4
IN5
IN6
IN7
IN8
COM
IN1
IN15
IN13
IN11
IN9
V
DC
- +
IN3
[Relay output]
V
V
OUT0
OUT1
OUT2
COM
COM
OUT3
COM
OUT4
OUT3
COM3
OUT4
COM4
OUT5
COM5
OUT6
COM6
OUT7
COM7
AC
COM
AC
COM
Load
[NPN output] [PNP output]
V
OUT0
OUT2
OUT4
OUT6
OUT5
OUT7
V
DC
GND
OUT8
V
DC
GND
OUT8
OUT9
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
DC
GND
+ -
OUT1
Load
OUT3
[DC PNP input/DC PNP output]
COM
IN0
IN2
IN4
IN6
IN5
IN7
V
IN8
DC
GNDGND
+ -- +
V
OUT8
OUT10
OUT12
OUT11
OUT14
OUT13
OUT15
COMV
IN1
IN3
DC
OUT9
­+
Load
IN10
IN9
OUT5
COM
OUT10
OUT9
IN10
OUT9
Load
IN12
IN14
IN13
IN11
[SSR output]
OUT6
OUT7
COM
COM
OUT12
OUT14
OUT13
OUT11
IN12
IN14
OUT13
OUT11
IN15
COM
OUT15
OUT15
Sensor connector type
When wiring the communication connector, use cable and tap which meet the DeviceNet standard and tighten the connector screw with a
tightening torque of 0.5N.m.
● AR -DI08N-4S ● AR -DI08P-4S ● AR -DO08N-4S ● AR -DO08P-4S
- +
- +
- +
- +
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
IN (NPN): 8P, 24VDC 10mA
IN (PNP): 8P, 24VDC 10mA
OUT (NPN): 8P, 24VDC 0.3A/Point
OUT (PNP): 8P, 24VDC 0.3A/Point
Terminating Resistance
● 120Ω ● 1% of metallic film ● 1/2W
Do not install terminating resistance on the unit, or it may cause network terminating problem (impedance can be too high
or low) and trouble.
Connect terminating resistance on the both ends of the trunk line.
X-21
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
ARD-D Series
Dimensions
Same dimensions are applied to both basic and expansion unit.
Tightening torque for mounting bolts: 1.8 to 2.5N·m
Standard terminal block type
105
50
3-Ø4.5
(unit: mm)
● Panel cut-out
50 3-M4 TAP
Sensor connector type
● Rail lock position:
mounting with bolt
12
2-Ø4.5
5238.5
60.5
54
4.9
● Rail lock position:
mounting on DIN rail
31
26
35.3
60.5
● Expansion connector
(supplied only for expansion unit)
9.8 10
6
4
Panel cut-out
7
X-22
86
93.8
85.4
76
81.8
35mm DIN rail
86
DeviceNet Digital Remote I/O
Setup and Installation
Setting Node address
Two rotary switches are used for setting node address. The ×10 switch represents tens
digit and the ×1 switch represents ones digit. The node address can be set 00 to 63.
After setting the desired node address, re-supply the unit power for applying the changed
node address.
The NODE ADDRESS of the connected unit must not be duplicated.
When changing the NODE ADDRESS during operation, the unit status (MS) LED flashes in red and the unit communicates to the NODE ADDRESS before the change.
Unit Installation
Mounting on panel
Pull rail locks (standard terminal block type: 3, sensor connector type: 2)
on the rear part of a unit, there are xing bolt hole.
Place the unit on a panel to be mounted.
Make holes on xing bolt positions.
Fasten the bolt to x the unit tightly.
Tightening torque should be below 0.5N·m.
Mounting on DIN rail
Pull rail locks (standard terminal block type: 3, sensor connector type: 2)
on the rear part of unit.
Place the unit on DIN rail to be mounted.
Press rail locks to x the unit tightly.
Connection of basic and expansion units
(standard terminal block type)
Turn OFF the power of a Basic unit.
Place an expansion unit to be installed next to the basic unit.
Connect the cable of expansion unit to the connector of a basic unit.
Install a connected expansion units as the right gures.
Supply the power to the basic unit.
⑤ ※
Re-supply the power of a basic unit and it recognizes expansion units.
Connection of basic and expansion units
(sensor connector type)
Turn OFF the power of the basic unit.
Remove a cover of connector for extension with nippers, etc.
Connect connector input part of an expansion unit and connector output
part of a basic unit with a connector which is enclosed with an expansion unit box.
Install a connected expansion units as the right gure.
Supply the power to the basic unit.
⑤ ※
Re-supply the power of a basic unit and it recognizes expansion units.
(E.g.)
X10 X1
The X10 and X1 switches point both at "3", so the address is "33".
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal line closely, use line lter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise.
4. Do not connect or disconnect the expansion unit when power is being supplied.
5. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specications')
Altitude max. 2,000m
Pollution degree 2
Installation category II
X-23
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
Loading...