
COMMON TERMINAL
BLOCK
ACS Series
M A N U A L
Thank you very much for selecting Autonics products.
For your safety, please read the following before using.
Caution for your safety
※
Please keep these instructions and review them before using this unit.
※
Please observe the following for safety.
※
The following is an explanation of the symbols used in the operation manual.
Caution: Injury or danger may occur under special conditions.
1. In case of using this unit with machinery (Ex: nuclear power control, medical equipment, ship, vehicle,
train, airplane, combustion apparatus, safety device, crime/disaster prevention equipment, etc) which
may cause damages to human life or property, it is required to install fail-safe device.
It may cause a re, human injury or damage to property.
2. Do not repair or check units during power on.
It may cause a re or electric shock.
3. Do not use this unit in place where there are ammable or explosive gas, humidity, direct ray of the sun,
radiant heat, vibration, impact etc.
It may cause a re or explosion.
4. Do not disassemble and modify this unit. Please contact us if it is required.
It may cause a re, electric shock, or damage to the product.
1. This unit shall not be used outdoors.
It may shorten the life cycle of the product or cause electric shock.
2. Please observe the rated specications.
It may shorten the life cycle of the product and cause a re.
3. In cleaning the unit, do not use water or organic solvents. And use dry cloth.
It may cause electric shock or damage to the product.
4. Do not inow dust or wire dregs into the unit.
It may cause a re or malfunction.
Après avoir lu ce guide, s'il vous plaît, placez-le dans un lieu où vous pouvez récemment le trouver.
※
S'il vous plaît suivre les conseils suivants pour la sécurité.
※
La signification des icones utilisées dans le produit et le manuel sont les suivants:
※
1. Utilisez le produit seulement après avoir relié un double dispositif de sécurité pour les instruments qui
ont un grand effet pour le corps humain et la propriété, comme sont les dispositifs d'énergie atomique,
mets en oeuvre Médecine, de véhicules, Rails, aéronefs, Brûleurs ou produits de sécurité.
L'inaccomplissement peut causer des incendies, lésions personnelles ou dommages à la propriété.
L'inaccomplissement peut causer des incendies, lésions personnelles ou dommages à la propriété.
2. Ne pas réparer ou vérier le produit tout alimenté.
L'inaccomplissement peut provoquer un incendie ou des décharges électriques.
3. Utilisez le produit avec l'environnement comme il est décrit dans le manuel. Évitez le lieu d'émission de
gaz corrosifs, gaz inammables, incorporation température, haute humidité, vibrations, choc, etc.
L'inaccomplissement peut provoquer un incendie ou une explosion.
4. Ne pas démonter et modier cet appareil. S'il vous plaît nous contacter si cela est nécessaire.
L'inaccomplissement pourrait causer des décharges électriques, incendies, lésions personnelles ou dommages à
le produit.
1. Cette unité ne doit pas être utilisé à l'extérieur.
Peut raccourcir le cycle de vie du produit ou causer un choc électrique.
2. S'il vous plaît respecter les spécications nominales.
L'inaccomplissement peut raccourcir le cycle de vie du produit et provoquer un incendie.
3. Dans nettoyer l'appareil, n'utilisez pas d'eau ou de solvants organiques. Et utiliser un chiffon sec.
L'inaccomplissement peut donner lieu des décharges électriques ou des dommages au produit.
4. Ne pas laisser de poussière pénétrer l'unité.
Cela pourrait provoquer un incendie ou un dysfonctionnement.
Serious injury may result if instructions are not followed.
Warning
Product may be damaged, or injury may result if instructions are not followed.
Caution
Warning
Caution
Précautions pour la sécurité.
Avertissement L'inaccomplissement des instructions peut provoquer des blessures graves.
Précaution
Précaution: Blessure ou danger peuvent se produire dans des conditions particulières.
Avertissement
Précaution
Le produit peut être endommagé ou de provoquer des blessures si les consignes ne sont pas respectées.
Ordering information
A
Terminal
type
Screw
B
<Forked>
Number of terminals Common type
20EA
40EA
50EA
B
A
D
C
<Round>
Left-Right Common
Left-Right Common
Left-Right Common
D
C
AWG 22-16
(0.30 to 1.25mm2)
(unit: mm)
Model Item
ACS-20L
ACS-20T Top-Bottom Common
ACS-40L
ACS-40T Top-Bottom Common
ACS-50L
Common
terminal
block
ACS-50T Top-Bottom Common
Applicable crimp terminal
Forked Min. 4.1 Max. 16.0 Min. 3.0 Max. 5.9
Round Min. 4.1 Max. 16.0 Min. 3.0 Max. 5.9
Use the UL cirtied crimpt terminal.
※
A B C D Applicable wires
Specications
Model ACS-20L ACS-20T ACS-40L ACS-40T ACS-50L ACS-50T
Rated voltage Max. 125VDC, 125VAC 50/60Hz
Rated current Max. 10A
Common type
Number of terminals 20EA 40EA 50EA
Terminal pitch 7.0mm
Applicable wires AWG22-16 (0.30 to 1.25mm2)
Insulation resistance Min. 1,000㏁ (at 500VDC megger)
Dielectric strength 600VAC 50/60Hz for 1 minute
Vibration 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X,Y,Z directions for 2 hours
Shock 150m/s2(15G) in each of X, Y, Z directions for 3 times
Ambient temp.
Environ
-ment
Ambient humi.
Material CASE: MPPO, TERMINAL PIN: Brass
Tightening torque 0.5 to 0.6 N.m
Approval
1
※
Weight
1: The weight is with packaging and the weight in parentheses is only unit weight.
※
Environment resistance is rated at no freezing or condenstion.
※
Wire connections
● ACS-20L
● ACS-40L
● ACS-50L
● ACS-40T / ACS-50T
※
The above specications are subject to change without notice.
Left +COM,
Right -COM
-15 to 55℃, Storage: -25 to 65
Top +COM,
Bottom -COM
Left +COM,
Right -COM
℃
Top +COM,
Bottom -COM
Left +COM,
Right -COM
35 to 85%RH, Storage: 35 to 85%RH
Approx. 92g (Approx. 61g) Approx. 157g (Approx. 115g) Approx. 189g (Approx. 141g)
● ACS-20T
B2 B7
B3 B8
B1
+ + + ++- - - - -
A1
A2 A7
A3 A8
+ +
+ +
B1 B2 B3 B4 B5 B6 B7 B8 B9
+
+ + + + + + + + +-- ------- -
A1 A2 A3 A4 A5 A6 A7 A8 A9
+
+ + + + + + + + +-- ------- -
B1 B2 B3 B4 B5 B6 B7 B8 B9
+
+ + + + + + + + + ------- -
A1A2A3 A4 A5 A6 A7 A8 A9
+
+ + + + + + + + +
B1 B2 B3 B4 B5 B6 B7 B8 B9
+
+ + + + + + + + +
A1 A2 A3 A4 A5 A6 A7 A8 A9
-
- ------- -
B6
B4 B9
B5
A6
A4 A9
A5
+
- - - - -
B10
A10
B11
B10
B12 B13 B14 B15 B16 B17 B18 B19 B20
A10 A11 A12 A13 A14 A15 A16 A17 A18 A19
B11
B10
B12 B13 B14 B15 B16 B17 B18 B19 B20
+ +
A10 A11 A12 A13 A14 A15 A16 A17 A18 A19
+ + +
B11
B10
B12 B13 B14 B15 B16 B17 B18 B19 B20
+
+ + + + + + + + +
A10 A11 A12 A13 A14 A15 A16 A17 A18 A19
-
- ------- -
B1
B2 B3 B4 B5
+
+ + + + +++ + +
A2 A3 A4 A5 A6 A7 A8 A9
A1
-
- - - - - - - - -
-----
※
Dot line part is only for ACS-50T model.
- -
A20
A20
A20
Top +COM,
Bottom -COM
B6 B7 B8 B9
B21 B22 B23 B24 B25
---
A21
-
B21 B22 B23 B24 B25
A21 A22 A23 A24
---
- -
A22 A23 A24
--- -
+ + + + +
- -
A10
A25
A25
Installation
1. Mounting to and Removing from DIN rail.
●
Mounting
1) Push rail lock to the direction "①".
2) Hook DIN rail connector onto DIN rail.
3) Push the unit down to the direction "②" and
then push up the rail lock to the unit body.
●
Removing
1) Insert a screwdriver into hole of rail lock and
pull the lock out to the direction "①".
2) Removing the unit by pulling to the direction "②".
2. Mounting to panel
1) This unit is able to mount on the panel with mounting holes.
2) It is recommended to use M3×30mm of spring washer screws and
to use at washers which are diameter ø6.
The tightening torque should be 0.5 to 0.7N·m.
Dimensions
● ACS-20L(T)
20-M3
● ACS-40L(T) / ACS-50L(T)
B10
Caution for using
1. This unit shall not be used beyond specified temperature or humidity range.
2. Maintain voltage fluctuations in the power supply within specified range.
3. When connecting PLC or other controllers, check the polarity of power and COMMON before wiring.
4. Use AWG 16(1.25mm2) wire and applicable crimp terminals to the terminal block.
5. Turn OFF the power supply before wiring.
6. Do not use this unit at below places.
7. Installation environment.
Major products
Photoelectric sensors Temperature controllers
Fiber optic sensors Temperature/Humidity transducers
Door sensors SSR/Power controllers
Door side sensors Counters
Area sensors Timers
Proximity sensors Panel meters
Pressure sensors Tachometer/Pulse(Rate) meters
Rotary encoders Display units
Connector/Sockets Sensor controllers
Switching mode power supplies
Control switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper motors/drivers/motion controllers
Graphic/Logic panels
Field network devices
Laser marking system(Fiber, CO₂, Nd:YAG)
Laser welding/soldering system
11
Place where there is severe vibration or impact.
①
Place where strong alkalis or acids are used.
②
Place where there are direct ray of the sun.
③
Place where strong magnetic field or electric noise are generated.
④
It shall be used indoor
①
Pollution Degree 2
③
※
It may cause malfunction if above instructions are not followed.
80
62.5
7
5.9
2-ø3.5
10.5
39.5
32.5
A
B
②
④
41.8
2-ø3.5
10.5
39.5
41.8
11
5.9
7
40-M3,
50-M3
32.5
Altitude Max. 2,000m
Installation Category II
HEAD QUARTERS:
116, Ungbigongdan-gil, Yangsan-si, Gyeongsangnam-do, Korea
OVERSEAS SALES:
#402-404, Bucheon Techno Park, 655, Pyeongcheon-ro,
Wonmi-gu, Bucheon, Gyeonggi-do, Korea
TEL: 82-32-610-2730 / FAX: 82-32-329-0728
E-mail: sales@autonics.com
The proposal of a product improvement and
DIN rail connector
DIN rail
Rail lock
①
②
Rail lock
39.7
45.8
35.2
ACS-40L(T) ACS-50L(T)
A 150 184
B 89 104
C 45.8 48.9
D 39.7 34.8
D
35.2
http://www.autonics.com
①
Panel mounting hole
C
Satisable Partner For Factory Automation
development: product@autonics.com
AS-KE-01-T0002E
②
(Unit: mm)