• Balanced Input Euro Block Phoenix Style Connectors
• Remote Turn On
• Accessory Card Slot for Optional Dante™ Digital Network Audio Card
• Fault Reporting
• Soft Clip Limiter Protection
• Stepped Attenuators with Security Covers
• Stereo or Parallel Operating Modes
• Selectable Input Sensitivity
• High Efficiency Fan Cooling
• Wide Range Global Power Supply with Power Factor Correction
• Meets Energy Star Standards for 1W Standby Mode
Applications
The HPA602 can be used for most audio applications, whether for
commercially installed 70V/100V distributed systems, or professional
high performance sound reinforcement applications. The HPA series will
provide efficient, stable, and reliable power making them the perfect
choice for night clubs, house of worship systems, portable sound
systems, convention centers, sports venues, hotels, and retail centers.
General Description
The AtlasIED High Power Amplifier HPA Series model HPA602 has been
designed to be used in both commercial 70V/100V distributed systems
and professional applications that require amplifiers to handle 8Ω and 4Ω
loads.
The HPA Series features Generation II Class D Output topology that
provides superior efficiency with the sound quality of a Class AB
amplifier. The power supply is a switch mode wide range design that
maintains a stable output during fluctuating power conditions. The power
supply and output stage collectively are designed to deliver exceptional
dynamic high output voltage and current to virtually any loudspeaker
load.
The HPA Series features front panel stepped level controls with a
security cover, remote turn on, balanced line inputs with sensitivity
settings, fault reporting and an accessory card slot for an optional
Dante™ two-channel digital audio interface. Cooling is not an issue
because of the unique output stage low resistance direct couple thermal
transfer design. HPA also is energy efficient and meets Energy Star 1W
standby mode standards.
Whether the application is a large distributed constant voltage sound
system or a high SPL sound reinforcement system, the AtlasIED HPA
Series is the answer for high power/cost effective reliable amplification
requirements.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005609 RevC 3/19
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
AtlasIED.com
Page 2
System
TypePower Amplifier, Two-Channel
Power Supply TypeSwitch Mode - Wide Range- PFC
Amp Topology Class D
Number of Fixed Inputs2
Accessory Inputs2
DSP InternalNo
NetworkNo
Optional Card SlotYe s
Output Power (Note 1)
100V x 2 CH2 x 300W
70.7V X 2 CH2 x 300W
8Ω x 2 CH2 x 300W
4Ω x 2 CH2 x 300W
2Ω x 2 CHN/A
8Ω BridgedN/A
4Ω BridgedN/A
Factory Default Settings (As Shipped)
Amplifier Configuration2 CH
Level ControlsFront Panel
Control Ports (Rear Panel)Remote Turn On / Off, Enable On
Input Sensitivity.775 / 0dBu
Inputs
Input Quantity2 Balanced Inputs, Expandable to 4 via Acccessory Card
Input TypeBalanced Line
Input Connectors Type3.5mm Euro Block
Input Impedance20KΩ (Balanced) 10KΩ (Unbalanced)
Input Sensitivity775mV / 1.0V / 32dB (Selectable)
Maximum Input Level dBu &Vrms24dBu, 12V (Accessory Slot Refer to Accessory Card Specifications)
Accessory Slot2 Input Dante™ Digital Card (HPA-DAC2 Optional)
Level Control
Front PanelRotary Stepped Attenuators with Security Cover
Status Indicators
PowerBlue
StandbyAmber
AC Mains Out of Safe Operating RangeRed
TempYellow
ReadyGreen
SignalGreen
Output LimitYellow
Output ProtectRed
BridgeN/A
GPIO Ports (Rear Panel)
Number of PortsQty 5
Type of ConnectorEuro Block 3.5mm
FunctionsRemote Turn ON via Contact Closure
FunctionsRemote Turn ON via DC Voltage 5-24V
Functions
Fault Report Contact - NC Under Safe Operating Conditions, NO When Fault is Detected, No AC Mains Power, Thermal,
Shorted Output, Over Current
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005609 RevC 3/19
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
AtlasIED.com
Page 3
Conguration Settings (Rear Panel)
Input Senstivity.775V, 1V, 32dB per CH
Parallel InputsYe s
BridgeN/A
Output Terminals (Speaker)
Output Connectors TypeRemovable Euro Block, 7.62mm Pitch, Locking
Output Connectors Number of Terminals4 Position
Wire Size6-18 Gauge (Class 2 Wire)
Current Rating57A per Terminal
Electrical Specications (General)
Total Harmonic Distortion 1 kHz and 1 dB Below
Rated Power
Signal to Noise Ratio>70dB Below Rated Output (A-Weighted)
Frequency Response20Hz - 20kHz (+0/-1.5dB)
Input Impedance Balanced (Nominal)100 Ω Balanced Line to Line
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005609 RevC 3/19
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
AtlasIED.com
Page 4
Agency Approvals
North America AgencyETL
Testing Standard North America60065
FCC Class A (Conducted & Radiated Emissions)Part 15 of the FCC Rules
CEYes (Includes RoHS & WEEE)
Optional Accessories
HPA-DAC2 - Dante™ Digital Audio InterfaceTwo-Channel Receive (Only) - Field Installable
NOTES:
1. Power level measurment is define as follows: 1Hz Sine wave signal burst of 20 cycles (20mS) at 1% THD+N, followed by 480 cycles of a 1kHz sine wave at 10% of the
max power. Other power measurements are available upon requests.
2. Power measurement with Ethernet connected. Without Ethernet connected deduct .2W
3. Average Power is defined as Pink Noise input signal applied to achieve 1/4 of the 4 Ohm or 70.7V power rating.
4. Max Power is defined as 1 KHz input signal applied to achieve the maxium power output before clipping into a 4 Ohm or 70.7V load.
5. BTU is calcualed by the AC Mains Power consumed minus the total power output measured at the specified load and condition, multiplied by 3.412.
Example: 785 Watts from the AC Source - 600 Watts Total Output power = 185 x 3.412 = 631 BTU
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005609 RevC 3/19
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
AtlasIED.com
Page 5
0
9.30
10.30
19.00
3.50
0
9.30
10.30
FRONT
SIDE
HPA602
Multi-Impedance Amplifier
Protect
Limit
Signal
Ready
Power
Temp
Standby
1
0102010
Dimensional Drawings
19.00
3.50
1601 Jack McKay Blvd. • Ennis, TX 75119
RISC OF ELECTRIC SHOCK
WARNING: SHOCK HAZARD - DO NOT OPEN
AVIS: RISQUE DE CHOC ELÉCTRIQUE - NE PAS OUVRIR
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
AVIS: NE PAS EXPOSER CE MATÉRIEL À LA PLUIE OU L’HUMIDITE
AFIN DE REDUIRE LE RISQUE D’INFLAMMATION OU DE CHOC ELÉCTRIQUE
800.876.3333 • AtlasIED.com
CAUTION
RISQUE D’ELÉCTROCUTION
DO NOT OPEN
Protect
Signal
Ready
1
0 1020 10
ATTENTION
NE PAS OUVRIR
APPARATETS STIKPROP SKAL TILSLUTTES EN STIKKONTAKT MED JORD,
Limit
SOM GIVER FORBINDELSE TIL STIKPROPPENS JORD.
LAITE ON LIITETTÄVÄ SUOJAKOSKETTIMILLA
VARUSTETTUUN PISTORASIAAN.
APPARATET MÅ TILKOPLES JORDET STIKKONTAKT.
APPARATEN SKALL ANSLUTAS TILL JORDAT UTTAG.
Power
Temp
Standby
17.00
Serial Number
Place Label Here
HPA602
Multi-Impedance Amplifier
CONFORMS TO
ANSI/UL STD. 60065
CERTIFIED TO
CAN/CSA STD.
C22.2 No. 60065
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005609 RevC 3/19
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
0
9.30
10.30
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
AtlasIED.com
Page 6
Optional Accessories
HPA-DAC2 - Dante™ Two-Channel Receiver Card
Architect and Engineer Specications
The power amplifier shall be a two-channel multi-impedance amplifier
capable of driving 100V, 70.7V, 8Ω, and 4Ω load conditions. The amplifier
shall have multiple internal circuits to protect itself and connected
speakers from Input RF, output DC, output short circuits, current
overload, clipping, AC mains under or over voltage, peak current limit,
and thermal overload. A variable speed fan shall provide rear to front
airflow for dynamic cooling. The universal PFC switch mode 50/60Hz
power supply operating range shall be 95V-264V. The AC Mains inlet
shall be C15 IEC Locking Receptacle and ship with a IEC 16-guage 1.5M
cord with a fixed NEMA 5-15 Male Plug. The HPA602 shall meet Energy
Star 1W Standby Mode Standards. Power ratings shall equal or exceed
300W x 2 @ 100V, 70.7V, 8Ω and 4Ω loads. Each balanced Line input
channel shall have a selectable input sensitivity of 0.775V, 1.0V, or 32dB,
and frequency response shall be 20Hz-20kHz (+0/-1.5dB) with a Signal
to Noise Ratio of >85dB below rated output (A-Weighted). Front panel
indicators shall include ready, signal present, limiter, and protection
LEDs. Front panel level controls shall be stepped attenuators with
security covers included. Input terminations shall be removable 3.5mm
Phoenix style connectors and loudspeaker outputs shall be a removable
4-position Phoenix style connector capable of accepting up to 8 AWG
wire. A switch on the rear panel shall provide selection of stereo, parallel
or bridge modes of operation. Rear panel 5 position Phoenix style GPIO
ports shall provide Remote Turn On and Fault Reporting for each channel.
The amplifier shall have one (1) rear mounted Accessory Card slot. This
slot shall be for an HPA-DAC2, a two-channel Dante™ Digital Audio
Receiver Input Card. Dimensions shall be 2 RU, 3.5" x 19" x 9.3" (89mm
x483mm x 236mm) and the amplifier shall weigh 14.8 lbs (6.7kg).
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005609 RevC 3/19
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
AtlasIED.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.