AtlasIED HPA1302 Owner's Manual

Owner’s Manual
Multi-Impedance High Power Amplifiers
HPA Series
HPA602 / HPA1302
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 1 – AtlasIED.com
Specifications are subject to change without notice.
HPA Series
Multi-Impedance High Power Amplifiers
Owner’s Manual
Table of Contents
Important Safety Instructions .................................................................................................................. 3
Introduction ............................................................................................................................................ 5
Key Features ........................................................................................................................................... 5
Front Panel Description ........................................................................................................................... 6
Tamper Proof Security Cover .................................................................................................................. 6
Rear Panel Description ............................................................................................................................ 8
Bridge Mode Operation ........................................................................................................................... 9
Remote Turn On .....................................................................................................................................10
Placement of the Amp .......................................................................................................................... 12
Cabling ................................................................................................................................................... 12
Connecting the HPA Amplifier to AC Mains .......................................................................................... 13
Optional Dante™ Input Card ................................................................................................................. 14
Specifications ........................................................................................................................................ 15
Warranty ................................................................................................................................................ 20
AtlasIED.com – 2 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Owner’s Manual
Multi-Impedance High Power Amplifiers
HPA Series
Important Safety Instructions
The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
WARNING: SHOCK HAZARD - DO NOT OPEN
AVIS: RISQUE DE CHOC ELÉCTRIQUE - NE PAS OUVRIR
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
AVIS: NE PAS EXPOSER CE MATÉRIEL À LA PLUIE OU L’HUMIDITE
AFIN DE REDUIRE LE RISQUE D’INFLAMMATION OU DE CHOC ELÉCTRIQUE
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this device near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other device that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the
other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they
exit from the device.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the device. When a cart is used,
use caution when moving the cart / device combination to avoid injury from tip-over.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
13. Unplug this device during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, such as
power-supply cord or plug is damaged, liquid has been spilled, or objects have fallen into the device, the device has been exposed
to rain or moisture, does not operate normally, or has been dropped.
15. This product is equipped with a three-wire grounding-type plug, a plug having a third (grounding) pin. This plug will only fit into a
grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to
replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type plug.
16. WARNING: To reduce the risk of fire or electric shock, this device should not be exposed to rain or moisture and objects filled with
liquids, such as a vase, should not be placed on this device.
17. To completely disconnect this equipment from the mains, disconnect the power supply cord plug from the receptacle.
18. The mains plug of the power supply cord shall remain readily operable.
19. Protective earthing terminal. The apparatus should be connected to a mains socket with a protective earthing connection.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 3 – AtlasIED.com
Specifications are subject to change without notice.
HPA Series
Multi-Impedance High Power Amplifiers
Owner’s Manual
WARNING - When The Device Is In Use
• WARNING: For the terminals marked with symbol of may be of sufficient magnitude to constitute a risk of electric shock. The
external wiring connected to the terminals requires installation by an instructed person or the used of ready-made leads or cords.
• WARNING: The apparatus shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be
placed on apparatus.
• WARNING: The mains plug is used as disconnect device, the disconnect device shall remain readily operable.
• To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to
AtlasIED.
• Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the
AC outlet and contact AtlasIED. Do not to attempt to continue operation with the product as this may cause fire or electric shock:
• Smoke or strange smell coming from the unit.
• If the product falls or the case is damaged.
• If water or any metallic objects falls into the product.
• If the power supply cord is damaged in any way.
• If the unit is malfunctioning.
• Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in
electric shock or fire.
• Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric
shock may result.
• Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.
• Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result.
• Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used.
• Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects
on the power cord, including the product itself, doing so may result in fire or electrical shock.
• Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic
disaster may result.
• Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property damage.
CAUTION - When Installing The Product
• Plugging in or unplugging the power cord with wet hands may result in electric shock.
• Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.
• When unplugging the cord from the wall, grasp the plug, NOT the cord.
• Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or
steam are present. Fire and electric shock may result.
• Keep all sides of the unit at least 31/2" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.
CAUTION - When The Product Is In Use
• Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In
addition, the product itself may fall and cause injury and property damage.
• Contact AtlasIED for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat
buildup and fire.
• Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or
inside the wall outlet.
• When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasIED.com – 4 –
Specifications are subject to change without notice.
Owner’s Manual
Multi-Impedance High Power Amplifiers
HPA Series
Introduction
Thank you for purchasing the AtlasIED HPA Series amplifier. The AtlasIED high power amplifier, “HPA” Series, is designed for use in both
commercial 70V/100V distributed systems and professional applications that require amplifiers to handle multiple impedance loads. The
HPA is compact and lightweight in comparison to other models delivering similar power levels. The HPA Series features Generation II
Class D Output topology that provides great efficiency with the sound quality of a Class AB amplifier. The power supply is a switch
mode, global auto sensing design that maintains a stable output during fluctuating power conditions. The power supply and output
stage collectively are designed to deliver exceptional dynamic high output voltage and current to virtually any loudspeaker load.
The HPA Series features front panel detente level controls with a security cover, remote turn on, balanced inputs, fault reporting and a
rear panel accessory card slot for an optional Dante™ 2-channel digital audio interface. HPA Series amplifiers feature a unique output
stage, low resistance direct coupled thermal transfer design that effectively maintains optimal temperature across all loads and output
levels. HPA Series amplifiers are also energy efficient and meet Energy Star standards, drawing only 1W of power in standby mode.
Whether the application is a large distributed constant voltage sound system or a high SPL sound reinforcement system, the AtlasIED
HPA Series is the answer for high power/cost effective amplification needs.
Key Features
• Two Channels
• 4Ω, 8Ω, & 70.7V Operation
• Balanced Inputs
• Dante™ Accessory Card Slot
• Fault Reporting
• Remote Turn On
• Stepped Attenuators with Security Cover
• Stereo or Parallel Operation Capability
• Auto Sensing 100V-240V~ AC Mains Power Supply
• Meets Energy Star Standards 1W Standby Mode
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 5 – AtlasIED.com
Specifications are subject to change without notice.
HPA Series
Multi-Impedance High Power Amplifiers
Owner’s Manual
Front Panel
1 1 3
1. Channel Level Controls
Each channel of the HPA amplifier has an independent detente level control. When either of the potentiometers is turned down (left or
FCC - fully counter clockwise) no signal will come out of the corresponding amp channel. When the potentiometer is turned up (right or
FC - fully clockwise) the amp will be set for maximum level.
2. Level Control Security Cover
The HPA Series comes with a tamper-proof level control security cover. There are two screws that hold the security cover in place
covering all level controls.
4
2
3. Air Exhaust
HPA amplifiers have fan assist cooling that draws cool air in from the rear of the amp and exhausts the hot air out the front panel.
4. Status Indicators
A. Power - When AC mains power is applied to the amplifier and the AC Mains Power Switch is in the “ON” position this LED
will illuminate blue indicating the amplifier is active and ready for use.
B. Standby - The Standby LED is a bi-color LED giving status of the amplifier power supply.
• Illuminated amber - The HPA Amplifier is in Energy Save Mode and is not ready for use. The rear panel remote activation
control port has to be triggered by applying 5-24DC Voltage or shorting the Contact Closure (CC) and ground (GND) pins
together to activate the amplifier to ready status. Note: The HPA Amp is shipped with a shunt across the CC and GND
contacts to activate the amp from Standby Mode. For the amplifier to be active or On, the Remote Turn On jumper must be
in place and the amplifier switch must be in the “On” position. If the Standby LED is not illuminated and the front panel blue
LED Power On is illuminated, the amplifier is active and ready to use. Refer to Remote Turn On for more information.
• Illuminated red - If the Standby LED is illuminating red, the AC Mains voltage applied to the HPA Amplifier is out of the
safe operating range. The HPA Amplifier cannot be turned on until the AC Mains voltage is between 95V~ - 264V~. Refer to
AC Mains Input for more information. If the Standby LED is not illuminated and the front panel blue LED Power On is
illuminated, the amplifier is active and ready to use.
C. Temp - This LED represents the temperature condition of the amplifier. This LED will illuminate yellow once the thermal
protection level of any of the amplifier channels or the power supply is reached causing the unit to power off. Note: Also refer to
the Protect LED.
AtlasIED.com – 6 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.