This trio of new Fluke infrared cameras is equipped with LaserSharp auto focus systems on the market but Fluke took it one step further so you get in-focused images, Every. Single. Time. Every infrared camera user knows that focus is the single most important thing to ensure when conducting an infrared inspection. Without an in-focus image temperature measure­ments may not be accurate and it’s much easier to miss a problem. LaserSharp auto focus tells you exactly where you are focusing. It uses a laser to calculate the distance to your target before it focuses. Place the red laser dot on the object you are inspecting, then pull and release the trigger for a perfect in-focus image.
Capture up to five additional measurements with
TM
CNX
Wireless System for more complete analysis
and reporting*
Detect and communicate issues faster with patented Fluke IR-Fusion
Faster communication with wireless image transfer directly to your PC, Apple
One-handed, easy-to-use user interface
Ruggedized high resolution 640x480 capacitive
touch screen for quick menu navigation
Capture additional digital images to show location or additional site details with IR-PhotoNotes Annotation System
Standard and radiometric video recording*
Streaming video (USB and HDMI)
Text* and voice recording and annotation gets
additional details saved with the image file
Optional interchangeable lenses for greater flexibility in additional applications
High-temperature measurement (up to 1200 °C on the Ti400)
Included SmartView Analysis and Reporting Software
* Coming soon via firmware update.
Users notified via SmartView software when available.
TM
®
technology with AutoBlendTM mode
®
iPhone® or iPad
®
and SmartView Mobile App
®
TM
Bring your office to your inspection site with the SmartView Mobile App. Create an inspection report on site and communicate directly to your client or manager via your Apple® iPhone® or iPad®.
Optimize: Adjust the image to present problems in the most effective way.
Analyze: Use markers and other tools to quantify the severity of problems.
Communicate: Share inspection results by emailing images or reports to:
Plan next steps or gain approval for work done before you even leave the job site
If needed, get assistance analyzing the problem
Fluke SmartView Mobile will increase the return on your
infrared camera investment.
Technical Data
Ti400 Ti300 Ti200
Announcing the new SmartView Mobile App
®
It’s not just about working faster – it’s about working smarter.
Detailed specifications
Temperature
Ti400 Ti300 Ti200
Temperature measurement range (not calibrated below -10 °C)
Temperature measurement accuracy
-20 °C to +1200 °C (-4 °F to +2192 °F)
-20 °C to +650 °C
(-4 °F to +1202 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes (by number and table) On-screen reflected background
temperature compensation
Yes
On-screen transmission correction Yes
Imaging performance
Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation Detector type Focal Plane Array, uncooled
microbolometer, 320 x 240 pixels
Focal Plane Array, uncooled
microbolometer, 240 X 180 pixels
Focal Plane Array, uncooled
microbolometer, 200 X 150 pixels
Thermal sensitivity (NETD) ≤ 0.05 °C at 30 °C target temp (50 mK) ≤ 0.075 °C at 30 °C target temp (75 mK) Total pixels 76,800 43,200 30,000
Infrared spectral band 7.5 μm to 14 μm (long wave) Visual (visible light) camera Industrial performance 5.0 megapixel Standard infrared lens type
Field of view 24 ° x 17 ° Spatial resolution (IFOV) 1.31 mRad 1.75 mRad 2.09 mRad Minimum focus distance 15 cm (approx. 6 in)
Optional telephoto infrared lens type, available soon
Field of view 12 ° x 9 ° Spatial resolution (IFOV) 0.65 mRad 0.87 mRad 1.05 mRad Minimum focus distance 45 cm (approx. 18 in)
Optional wide-angle infrared lens type, available soon
Field of view 46 ° x 34 ° Spatial resolution (IFOV) 2.62 mRad 3.49 mRad 4.19 mRad Minimum focus distance 15 cm (approx. 6 in)
Focus mechanism
LaserSharp
Auto Focus System Yes
Advanced Manual Focus Yes
Image presentation
Palettes
Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Ultra Contrast™ Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra,
Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra Level and span Smooth auto-scaling and manual scaling of level and span Fast auto toggle between manual
and auto modes
Yes
Fast auto-rescale in manual mode Yes Minimum span (in manual mode) 2.0 °C (3.6 °F) Minimum span (in auto mode) 3.0 °C (5.4 °F)
IR-Fusion
® information
Picture-In-Picture (PIP) Yes Full screen infrared Yes AutoBlend™ mode Yes Color alarms (temperature alarms) High-temperature , low-temperature, and isotherm (user-selectable)
Image capture and data storage
Image capture, review, save mechanism
One-handed image capture, review, and save capability
Storage medium Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) Video*: non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
Export file formats w/SmartView software
®
No analysis software required for non-radiometric (.bmp, .jpg and .avi*) files
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review Thumbnail view navigation and review selection
Other time-saving and productivity features
Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager IR-PhotoNotes™ Yes Wi-Fi connectivity Yes, to PC, iPhone Text annotation*
®
, iPad® and WiFi to LAN*
Yes
Video recording* Standard and Radiometric Streaming Video Via USB to PC and HDMI to HDMI compatible screen CNX™ Wireless System* Yes* Cardinal Compass* Yes* GPS coordinates and recording Yes Auto capture Remote control and operation (for
(temperature and interval)* Yes*
Yes No No
special and advanced applications)
* Coming soon via firmware update. Users notified via SmartView software when available.
2 Fluke Corporation Ti400, Ti300, and Ti200 Industrial Thermal Imagers
General specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F) Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries Relative humidity 10 % to 95 % non-condensing Ruggedized Touchscreen
Display (Capacitive) Controls and adjustments User selectable temperature scale (°C/°F)
Software SmartView Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models Battery life Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage) Battery charge time 2.5 hours to full charge AC battery charging Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional
AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included. Power saving User selectable sleep and power off modes Safety standards UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010) Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005
C Tick IEC/EN 61326-1 US FCC CFR 47, Part 15 Subpart B Class B Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
Shock 25 g, IEC 68-2-29 Drop Engineered to withstand 2 meter (6.5 feet) with standard lens Size (H x W x L) 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) Weight (battery included) 1.04 Kg (2.3 lb) Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions) Warranty Two-years (standard), extended warranties are available. Recommended calibration cycle Two-years (assumes normal operation and normal aging) Supported Languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chi-
8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Language selection Time/Date set Emissivity selection Reflected background temperature compensation Transmission correction User selectable hot spot and cold spot, and center point on the image Expandable-contractable Measurement Box with MIN-AVG-MAX temp Color alarms User selectable backlight setting Graphical information display preference
12 V automotive charging adapter. All models
nese, Spanish, Swedish, Traditional Chinese, and Turkish
®
and SmartView Mobile App - full analysis and reporting software included
Ordering information
FLK-Ti400 9 Hz Thermal Imager, 9 Hz FLK-Ti400 60 Hz Thermal Imager, 60 Hz FLK-Ti300 9 Hz Thermal Imager, 9 Hz FLK-Ti300 60 Hz Thermal Imager, 60 Hz FLK-Ti200 9 Hz Thermal Imager, 9 Hz FLK-Ti200 60 Hz Thermal Imager, 60 Hz
Included
Thermal imager with standard infrared lens; ac power supply and battery pack charger (including mains adapters); two, rugged lithium ion smart battery packs; Micro SD memory card with SD adapter; 3m USB cable; 3m HDMI video cable; SmartView® software with free software upgrades for life; rugged, hard carrying case; soft transport bag; adjustable hand strap; printed users manual (five languages); CD user manual; warranty registration card.
Optional accessories
FLK-LENS/TELE2 Telephoto infrared lens (2X magnification) FLK-LENS/WIDE2 Wide-angle infrared lens TI-CAR-CHARGER Thermal imager vehicle charger FLK-TI-VISOR3 Thermal imager visor BOOK-ITP Introduction to Thermography Principles book TI-TRIPOD3 Tripod mounting base accessory
3 Fluke Corporation Ti400, Ti300, and Ti200 Industrial Thermal Imagers
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
Modification of this document is not permitted without written permission from Fluke Corporation.
Loading...