Ti125, Ti110, Ti105
Industrial-Commercial
and the Ti100 General
Use Thermal Imagers
The lightest, most rugged and
easiest–to-use professional
thermal imagers around.
A Fluke thermal imager can save you time and money by finding
potential problems before they become costly failures. With the
innovative features and functionality in the Fluke Ti125, Ti110,
Ti105 and Ti100 imagers, you can perform infrared inspections
faster and more efficiently and thoroughly document problem areas
for additional follow-up.
Ti125
Key features
•Exclusive IR-OptiFlex
in good focus from 1.2 meters (4 feet) and beyond for
optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger (Ti110
and Ti125).
•Always have references handy—IR-PhotoNotes
system—Quickly identify and keep track of inspection locations
by adding digital images of important information and
surrounding areas (Ti110 and Ti125).
•Find problems faster and easier with Fluke IR-Fusion
(Ti125, Ti110, Ti105). Accurately identify potential issues
by combining digital and IR images.
•Capture additional measurements fast and conveniently from up
to five wireless modules at once using your Fluke thermal imager
and CNX
•Get further clarification with AutoBlend
of a digital and partially transparent IR image into a single
information-filled image (Ti125 only).
•Multi-mode video recording—focus-free video in visible light
and infrared with full IR-Fusion. (Ti110 and Ti125 only).
•Easily communicate the location of problems with the Electronic
8-Point Cardinal Compass (Ti110 and Ti125 only).
Spend less time finding problems and more time solving them
with the innovative, rugged and easy to use Ti125, Ti110, Ti105
Industrial-Commercial and Ti100 General Use Thermal Imagers.
™
wireless modules.
Ti110
Ti100
Made in
the U.S.A.
of U.S. and
non U.S.
parts
™
Fluke CNX™ enabled
Industrial, mechanical,
electromechanical and general
building maintenance.
Process, refractory insulation, tank
and vessel levels, steam systems
and traps, pipes and valves, etc.
Electrical, unbalanced loads,
overloaded systems, wiring problems
or component failure, etc.
Ti105
Technical Data
™
focus system—ensures that images are
™
annotation
®
technology
™
mode—the blending
Patented Fluke IR-Fusion® Technology
Enjoy the industry’s only point-and-shoot IR-Fusion
camera. Fluke patented technology provides the user
with both a digital and an infrared image in one to
precisely document problem areas.
IR-OptiFlex™ focus system
Scan for issues significantly faster than before
with Fluke’s revolutionary, ultra-rugged focus system.
The IR-OptiFlex focus system gives you optimum
focus by combining focus-free, ease-of-use with
the flexibility of manual focus on the same camera.
Detailed specifications
Ti125 Ti110 Ti105 Ti100
Industrial-Commercial General use
IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
Spectral band 7.5 μm to 14 μm (long wave)
Capture or refresh rate 9 Hz or 30 Hz versions 9 Hz
NETD (Thermal sensitivity) ≤ 0.10 °C at 30 °C target temp (100 mK)
FOV (Field of view) 22.5 °H x 31 °V
IFOV (Spatial resolution) 3.39 mRad
Temperature measurement range
(not calibrated below -10 °C)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanism IR-OptiFlex
®
IR-Fusion
CNX
technology
™
Wireless enabled Yes
Color alarms
Standard palettes
™
Ultra Contrast
palettes
Hot/cold markers Yes —
User definable spot markers Three on camera and in SmartView
Centerpoint Yes
Centerbox (MIN/AVG/MAX) Yes —
Level and span control Manual and auto
Minimum span in auto mode 5 °C
Minimum span in manual mode 2.5 °C
Minimum IR focus distance 15.25 cm (6 in) 122 cm (48 in)
Weight 0.726 kg (1.6 lb)
Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal (portrait format)
Visible camera 2 megapixel industrial-grade N/A
Minimum parallax ~45.7 – 55.9 cm (~ 18 in – 22 in) ~122 cm (48 in) N/A
IR-PhotoNotes
™ annotation system Yes (3 images) —
Laser pointer Yes
Torch Yes —
Electronic (cardinal) compass Yes —
Emissivity correction Yes
Transmission correction Yes —
Background (reflected) compensation Yes
Voice annotation (audio) Yes (60 seconds) per image —
Multi-mode video output
Multi-mode video recording
(standard avi w/ mpeg encoding)
Multi-mode video recording
(radiometric .is3)
Memory review thumbnail review
Battery (field-replaceable,
rechargeable)
Battery life 4+ hours (each)*
External battery charging base Yes Optional (accessory)
Charging power supply Yes
*Assumes 50 % brightness of LCD
-20 °C to +350 °C
(-4 °F to +662 °F)
™ focus system Focus-free 1.2 m (4 ft) and beyond
PIP, FULL IR, FULL VISIBLE,
AutoBlend
™
High temperature,
low temperature, isotherm
PIP, FULL IR, FULL VISIBLE
High temperature —
Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot
Metal, Ironbow, Amber, Inverted Amber
-20 °C to +250 °C (-4 °F to +482 °F)
PIP (1.2 m (4 ft) to 4.6 m
(15 ft)), FULL IR, FULL VISIBLE
Blue-Red, Ironbow, Grayscale, Amber
Blue-Red, Grayscale, Inverted
Grayscale, High-contrast,
Hot Metal, Ironbow, Amber,
Blue-Red, Grayscale, Ironbow —
Inverted Amber
®
Streaming USB video
output (infrared, visible and
—
IR-Fusion modes)
Yes (AVI with MPEG encoding, up to 5 minutes) —
Yes, radiometric .is3 for
approx. 2.5 to 5 minutes de-
—
pending upon thermal scene
Two One
No, full IR only
in SmartView® only
2 Fluke Corporation Ti125, Ti110, Ti105 Industrial/Electrical and Ti100 General Use Thermal Imagers