Atec Ti User Manual

Ti125, Ti110, Ti105 Industrial-Commercial and the Ti100 General
Use Thermal Imagers
The lightest, most rugged and easiest–to-use professional thermal imagers around.
Ti125
Key features
•Exclusive IR-OptiFlex in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter dis­tances change to manual mode with the touch of a finger (Ti110 and Ti125).
•Always have references handy—IR-PhotoNotes system—Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas (Ti110 and Ti125).
•Find problems faster and easier with Fluke IR-Fusion (Ti125, Ti110, Ti105). Accurately identify potential issues by combining digital and IR images.
•Capture additional measurements fast and conveniently from up to five wireless modules at once using your Fluke thermal imager and CNX
•Get further clarification with AutoBlend of a digital and partially transparent IR image into a single information-filled image (Ti125 only).
•Multi-mode video recording—focus-free video in visible light and infrared with full IR-Fusion. (Ti110 and Ti125 only).
•Easily communicate the location of problems with the Electronic 8-Point Cardinal Compass (Ti110 and Ti125 only).
Spend less time finding problems and more time solving them with the innovative, rugged and easy to use Ti125, Ti110, Ti105 Industrial-Commercial and Ti100 General Use Thermal Imagers.
wireless modules.
Ti110
Ti100
Made in
the U.S.A.
of U.S. and
non U.S.
parts
Fluke CNX™ enabled
Industrial, mechanical, electromechanical and general building maintenance.
Process, refractory insulation, tank and vessel levels, steam systems and traps, pipes and valves, etc.
Electrical, unbalanced loads, overloaded systems, wiring problems or component failure, etc.
Ti105
Technical Data
focus system—ensures that images are
annotation
®
technology
mode—the blending
Patented Fluke IR-Fusion® Technology
Enjoy the industry’s only point-and-shoot IR-Fusion camera. Fluke patented technology provides the user with both a digital and an infrared image in one to precisely document problem areas.
IR-OptiFlex focus system
Scan for issues significantly faster than before with Fluke’s revolutionary, ultra-rugged focus system. The IR-OptiFlex focus system gives you optimum focus by combining focus-free, ease-of-use with the flexibility of manual focus on the same camera.
Detailed specifications
Ti125 Ti110 Ti105 Ti100
Industrial-Commercial General use
IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer Spectral band 7.5 μm to 14 μm (long wave) Capture or refresh rate 9 Hz or 30 Hz versions 9 Hz NETD (Thermal sensitivity) ≤ 0.10 °C at 30 °C target temp (100 mK) FOV (Field of view) 22.5 °H x 31 °V IFOV (Spatial resolution) 3.39 mRad Temperature measurement range
(not calibrated below -10 °C) Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) Focus mechanism IR-OptiFlex
®
IR-Fusion
CNX
technology
Wireless enabled Yes
Color alarms
Standard palettes
Ultra Contrast
palettes
Hot/cold markers Yes User definable spot markers Three on camera and in SmartView Centerpoint Yes Centerbox (MIN/AVG/MAX) Yes Level and span control Manual and auto Minimum span in auto mode 5 °C Minimum span in manual mode 2.5 °C Minimum IR focus distance 15.25 cm (6 in) 122 cm (48 in) Weight 0.726 kg (1.6 lb) Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) LCD display 3.5 inch diagonal (portrait format) Visible camera 2 megapixel industrial-grade N/A Minimum parallax ~45.7 – 55.9 cm (~ 18 in – 22 in) ~122 cm (48 in) N/A IR-PhotoNotes
annotation system Yes (3 images)
Laser pointer Yes Torch Yes Electronic (cardinal) compass Yes Emissivity correction Yes Transmission correction Yes Background (reflected) compensation Yes Voice annotation (audio) Yes (60 seconds) per image
Multi-mode video output
Multi-mode video recording (standard avi w/ mpeg encoding)
Multi-mode video recording (radiometric .is3)
Memory review thumbnail review Battery (field-replaceable,
rechargeable) Battery life 4+ hours (each)* External battery charging base Yes Optional (accessory) Charging power supply Yes
*Assumes 50 % brightness of LCD
-20 °C to +350 °C (-4 °F to +662 °F)
focus system Focus-free 1.2 m (4 ft) and beyond
PIP, FULL IR, FULL VISIBLE,
AutoBlend
High temperature,
low temperature, isotherm
PIP, FULL IR, FULL VISIBLE
High temperature
Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot
Metal, Ironbow, Amber, Inverted Amber
-20 °C to +250 °C (-4 °F to +482 °F)
PIP (1.2 m (4 ft) to 4.6 m
(15 ft)), FULL IR, FULL VISIBLE
Blue-Red, Ironbow, Grayscale, Amber
Blue-Red, Grayscale, Inverted
Grayscale, High-contrast,
Hot Metal, Ironbow, Amber,
Blue-Red, Grayscale, Ironbow
Inverted Amber
®
Streaming USB video
output (infrared, visible and
IR-Fusion modes)
Yes (AVI with MPEG encoding, up to 5 minutes)
Yes, radiometric .is3 for
approx. 2.5 to 5 minutes de-
pending upon thermal scene
Two One
No, full IR only
in SmartView® only
2 Fluke Corporation Ti125, Ti110, Ti105 Industrial/Electrical and Ti100 General Use Thermal Imagers
Loading...
+ 1 hidden pages