Atec TDS7000B User Manual

Digital Phosphor Oscilloscopes
TDS7000B Series
Superior Measurement Fidelity, Unrivaled Analysis, Uncompromised Usability
The TDS7000B Series’ unique combina­tion of superior measurement fidelity, unrivaled analysis and uncompromised usability makes it the ultimate test machine to simplify and speed the design of high-speed, complex systems. This family offers the industry’s best solution to the challenging signal integrity issues faced by designers verifying, character­izing and debugging sophisticated electronic designs. They deliver up to 7.25 GHz (typical) true analog bandwidth, down to 43 ps rise time (20% to 80%), and 20 GS/s maximum real-time sample rate to capture critical events with fine detail.
Exclusive DPX enables waveform capture rates up to 400,000 wfms/s to quickly find rare glitches in seconds or minutes, instead of hours or days. Innovative software solutions deliver domain expertise for advanced analysis and compliance testing, while the OpenChoice enables users to integrate their expertise through the ability to easily write custom programs or utilize popular commercial software. The intuitive graphical user interface delivers sophisticated capability to advanced users without intimidating occasional users.
®
acquisition technology
®
architecture
Features & Benefits
Up to 7.25 GHz True Analog Bandwidth and Down to 43 ps Rise Time (20% to 80%)
>400,000 wfms/s Waveform Capture Rate, Powered by Exclusive DPX®Acquisition Technology
20 GS/s Maximum Real-time Sample Rate
Exceptional Delta-time Accuracy for High Confidence in Critical Timing Measurements
MyScope®Custom Control Windows Enhance Productivity
Right Mouse Click Menus for Exceptional Efficiency
Powerful Triggering Features for Fast Detection of Relevant Faults
Communications Mask Testing Up to 4.25 Gb/s Rates
Clock Recovery from Serial Data Streams up to 3.125 Gb/s
Up to 64 MB Record Length with MultiView Zoom™for Quick Navigation of Long Records
TekConnect®Interface for High Fidelity Connection
Classic Direct Controls, Touch-sensitive Display or Mouse Navigation
OpenChoice®with Microsoft Windows 2000 Delivers Built-in Networking and Analysis
XGA 1024x768 Display
Applications
Signal Integrity, Jitter and Timing Analysis
Verification, Debug and Characterization of Sophisticated Designs
Design, Development and Compliance Testing of Serial Data Streams Up to 4.25 Gb/s Rates
Debug of Telecom, Datacom and Storage Area Network Equipment Designs, and High-speed Backplanes
Spectral Analysis
Investigation of Transient Phenomena
Digital Phosphor Oscilloscopes
TDS7000B Series
MyScope®Custom Control Windows
MyScope control windows allow you to build your own control windows with only the controls, features and capabilities that you care about and are important in your job. For the first time you can create your own personalized “toolbox” of oscilloscope features. No longer do you need to search through menus for features or re-learn how to drive the oscilloscope after a break from the lab. MyScope control windows are easily created in a matter of minutes using a simple, visual, drag-and-drop process. Once created, these customized windows are easily accessed through a dedicated MyScope button and menu selection on the oscilloscope button/menu bar, just like any other control window. You can make an unlimited number of custom control windows, enabling each person who uses the oscilloscope in a shared
environment to have their own unique control window. Since the control windows are stored as files on the hard drive, they can easily be transferred to other CSA7000B, TDS5000B or TDS6000B/C Series oscilloscopes, or they can even be e-mailed to a co-worker around the world when the need arises. MyScope control windows will benefit all oscilloscope users, from eliminating the ramp-up time that many face when returning to the lab after not using an oscilloscope for a while, to the power user who can now operate far more efficiently. Everything you need is found in one control window rather than having to constantly navigate through menu after menu to repeat similar tasks.
Right Clicks
Right mouse click menus make simple things as they should be – simple. Right click menus are context sensitive, meaning the choices presented in the menu depend on where you right clicked
the mouse. This makes right click menus extremely intuitive. Want to change the cursor type? Right click on a cursor or the cursor readouts. Want to change the reference levels of an automatic measure­ment? Right click on the measurement. Want to change trigger parameters? Right click on the trigger readouts. Want to change a waveform’s color? Right click on the waveform handle. Virtually all objects on the oscilloscope display have right click menus associated with them that include all the appropriate actions or features relative to those objects. There are also right click menus for regions of the display in addition to just objects. For example, right clicking in the main graticule brings up a menu with choices such as Clear Data, Default Setup, Autoset, Screen Captures, Save All Waveforms and Add Screen Text, providing single-click access to many of your most commonly performed tasks.
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
2
Digital Phosphor Oscilloscopes
TDS7000B Series
Characteristics
Vertical System
TDS7054 TDS7104 TDS7154B TDS7254B TDS7404B TDS7704B
Input Channels 4 4 4 4 4 4
Hardware Analog 500 MHz 1 GHz 1.5 GHz
*1
Bandwidth (–3 dB) (typical), 7GHz
Rise Time 10% 800 ps 400 ps 200 ps 130 ps 100 ps 62 ps to 90% (typical)
Rise Time 20% 135 ps 83 ps 72 ps 43 ps to 80% (typical)
DC Gain Accuracy 1% ±(2% + ±2.5% +
(2% x offset) (2% x offset)
Hardware Bandwidth 250 MHz or 20 MHz Requires TCA-1 MEG Limits
Input Coupling AC, DC, GND DC, GND
Input Impedance 1 M±0.5% or 50 Ω ±1% 50 Ω ±2.5%
Input Sensitivity, 1 M 1 mV/div to 10 V/div
Input Sensitivity, 50 1 mV/div to 1 V/div 2 mV/div to 1 V/div
Vertical Resolution 8-Bit (>11-Bit with averaging) 8-Bit (>11-Bit with averaging)
Max Input Voltage, ±150 V CAT I Derate at 20 dB/decade — 1M to 9 V
Max Input Voltage, 5 V
, with peaks less than ±30 Volts <1 V
RMS
above 200 kHz
RMS
for <100 mV/div, <5 V
RMS
50 Also determined by TekConnect®accessory
Offset Range 1 mV/div to 100 mV/div: ±1 V 2 mV to 50 mV/div: ±0.5 V
101 mV/div to 1 V/div: ±10 V 50.5 mV to 99.5 mV: ±0.25 V
1.01 V/div to 10 V/div: ±100 V 100 mV to 500 mV: ±5 V
Channel-to-Channel 100:1 at 100 MHz and 80:1 at 1.5 GHz and Isolation Any Two 30:1 at the rated bandwidth 15:1 at the rated bandwidth Channels at Equal Vertical Scale Settings ≥≥≥≥
*1
At 10 mV/div.
*1
2.5 GHz
for 100 mV/div settings
RMS
505 mV to 1 V/div: ±2.5 V
4 GHz
*1
7.25 GHz
*1
guaranteed
*1
Note: Typical system bandwidth of TDS7404B with P7240: 4 GHz.
Note: Typical system bandwidth of TDS7404B with P7330: 3.5 GHz.
Note: Typical system bandwidth of TDS7704B with P7260: 6 GHz.
Note: Typical system bandwidth of TDS7704B with P7350: 5 GHz.
Note: Typical system bandwidth of TDS7704B with P7380: 7 GHz.
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
3
Digital Phosphor Oscilloscopes
TDS7000B Series
Time Base System
TDS7054/TDS7104 TDS7154B/TDS7254B/
TDS7404B/TDS7704B
Time Base Range 200 ps/div to 40 s/div 50 ps to 10 s/div
Time Base Delay Time Range 16 ns to 250 s 5 ns to 250 s
Channel-to-Channel Deskew Range ±25 ns ±75 ns
Delta Time Measurement Accuracy ±((0.06/sample rate) + (15 ppm x reading)) RMS ±((0.06/sample rate) + (2.5 ppm x reading)) RMS
Trigger Jitter (RMS) 8 ps
Long Term Sample Rate and Delay ±15 ppm over 1 ms interval 2.5 ppm over any 100 ms interval Time Accuracy
Acquisition System
TDS7054 TDS7104 TDS7154B/ TDS7254B/
Real-time Sample Rates
1 channel (max) 5 GS/s 10 GS/s 20 GS/s
2 channels (max) 5 GS/s 5 GS/s 10 GS/s
3-4 channels (max) 2.5 GS/s 2.5 GS/s 5 GS/s
Equivalent Time Sample Rate (max) 250 GS/s 250 GS/s 1 TS/s
Maximum Record Length per Channel 2 Mb (1-CH.), 1 Mb (2-CH.), 500 Kb (4-CH.) 4 Mb (1-CH.), 2 Mb (2-CH.), with Standard Memory 1 Mb (4-CH.)
With Memory Opt. 2M 8 Mb (1-CH.), 4 Mb (2-CH.),
With Memory Opt. 3M 16 Mb (1-CH.), 8 Mb (2-CH.),
With Memory Opt. 4M 32 Mb (1-CH.), 16 Mb (2-CH.),
With Memory Opt. 5M 64 Mb (1-CH.), 32 Mb (2-CH.),
(typical) 2 ps
RMS
2 Mb (4-CH.)
4 Mb (4-CH.)
(typical) (7254B/7154B)
RMS
1.5 ps
1.2 ps
(typical) (7404B)
RMS
(typical) (7704B)
RMS
TDS7404B/ TDS7704B
8 Mb (4-CH.)
16 Mb (4-CH.)
Maximum Duration at Highest Real-time Resolution (1-CH)
TDS7054 TDS7104 TDS7154B/TDS7254B/
TDS7404B/TDS7704B
Time Resolution (Single-shot) 200 ps (5 GS/s) 100 ps (10 GS/s) 50 ps (20 GS/s)
Max Duration with Standard Memory 400 µs 200 µs 200 µs
Max Duration with Opt. 2M 1.6 ms 800 µs 400 µs
Max Duration with Opt. 3M 3.2 ms 1.6 ms 800 µs
Max Duration with Opt. 4M 1.6 ms
Max Duration with Opt. 5M 3.2 ms
4
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
Digital Phosphor Oscilloscopes
TDS7000B Series
Acquisition Modes
TDS7054/TDS7104 TDS7154B/TDS7254B/
TDS7404B/TDS7704B
FastAcq Acquisition Powered by exclusive DPX®acquisition technology, FastAcq optimizes the instrument
for analysis of dynamic signals and capture of infrequent events
Maximum FastAcq Waveform Capture Rate >200,000 wfms/sec >400,000 wfms/sec
Waveform Database Accumulate Waveform Database providing three-dimensional array of amplitude, time and counts
Sample Acquire sampled values
Peak Detect Captures narrow glitches at all real-time sampling rates
Minimum Peak Detect Pulse Width 1 ns 400 ps
Averaging From 2 to 10,000 waveforms included in average
Envelope From 2 to 2x109waveforms included in min-max envelope
Hi-Res Real-time boxcar averaging reduces random noise and increases resolution
FastFrame™Acquisition Acquisition memory divided into segments; maximum trigger rate >265,000 waveforms per second.
Time of arrival recorded with each event
Trigger System
TDS7054 TDS7104 TDS7154B/TDS7254B/
TDS7404B/TDS7704B
Sensitivity
Internal DC Coupled 0.35 div DC to 50 MHz 0.35 div DC to 50 MHz 0.5 div DC to 50 MHz
increasing to 1 div at 500 MHz increasing to 1 div at 1 GHz increasing to 1.5 div at 3 GHz
TDS7404B/TDS7704B:
2.7 div at 4 GHz (typical)
External (Auxiliary Input) 400 mV from DC to 50 MHz 250mV from DC to 50 MHz 150 mV from DC to 50 MHz
increasing to 750 mV at 100 MHz increasing to 500mV at 100 MHz increasing to 500 mV at 2.5 GHz
Main Trigger Modes Auto, Normal and Single
Trigger Sequences Main, Delayed by Time, Delayed by Events. All sequences can include separate
horizontal delay after the trigger event to position the acquisition window in time
Trigger Characteristics
Standard Trigger Types Edge, Glitch, Runt, Width, Transition Time, Edge, Glitch, Runt, Width, Transition
Timeout, Pattern, State, Setup/Hold Time, Timeout, Pattern, State, Setup/
Hold, Window - all except Edge, Pattern,
and State can be logic qualified
Communications-related Triggers Support for AMI, HDB3, BnZS, CMI, MLT3 and NRZ encoded communications signals. (requires Option SM) Select among isolated positive or negative one, zero pulse form or eye patterns as applicable to standard
Serial Pattern Trigger 64-Bit serial word recognizer, bits specified in binary (high, low, don’t care) (requires Option ST) or hex format. Trigger on NRZ-encoded data up to 1.25 GBaud
Trigger Level Range
Internal ±12 divisions from center of screen
External (Auxiliary In) ±8 V ±5 V
Line fixed at 0 V
Trigger Coupling DC, AC (attenuates <60 Hz), HF Rej (attenuates >30 kHz), LF Rej (attenuates <80 kHz), Noise Reject (reduces sensitivity)
Trigger Holdoff Range 250 ns minimum to 12 s maximum
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
5
Digital Phosphor Oscilloscopes
TDS7000B Series
Clock Recovery System (Option SM, ST)
TDS7154B/TDS7254B/TDS7404B/TDS7704B
Clock Recovery Phase Locked Loop Bandwidth Fbaud/1600 typical
Tracking/Acquisition Range ±2% of requested baud
Clock Recovery Jitter (Typical) 0.25% period +5 ps
or 4 ps
for repeating “011” data patterns
RMS
Input Sensitivity for Clock Recovery 1 division peak-to-peak displayed signal
Input Data Rates 1.5 Mbaud to 3.125 Gbaud
for PRBS data pattern
RMS
Trigger Modes
Edge – Positive and/or negative slope on any channel or front panel auxiliary input. Coupling includes DC, AC, noise reject, HF reject and LF reject. Glitch – Trigger on or reject glitches of positive, negative or either polarity. Minimum glitch width is
1.0 ns with 200 ps resolution (TDS7104/TDS7054). Minimum glitch width is 170 ps (TDS7704B) or 225 ps (all other B models) with rearm time of 250 ps (B models). Width – Trigger on width of positive or negative pulse (down to 170 ps on B models) either within or out of selectable time limits – 1 ns. (TDS7104/TDS7054) or 340 ps (B models) to 1 s). Runt – Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. Optional time qualification.
Timeout – Trigger on an event which remains high, low or either, for a specified time period, selectable from 1 ns (TDS7104/TDS7054) or 340 ps (B models) to 1 s with 200 ps (TDS7104/TDS7054) or 100 ps (B models). Transition – Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative or either. Setup/Hold – Trigger on violations of both setup time and hold time between clock and data present on any two input channels. Pattern – Trigger when pattern goes false or stays true for specified period of time. Pattern (AND, OR, NAND, NOR) specified for four input channels defined as HIGH, LOW or Don’t Care. State – Any logical pattern of channels (1, 2, 3) clocked by edge on channel 4. Trigger on rising or falling clock edge.
Window – Trigger on an event that enters or exits a window defined by two user-adjustable thresholds. Event can be time or logic qualified (B models only) Logic Qualified Trigger applicable to Glitch, Width, Runt, Timeout, Transition, Setup/Hold, Window trig­gers – trigger on the specified event only if the logic state defined with the remaining unused channels occurs (B models only).
Trigger Delay by Time –
16 ns (5 ns for B models) to 250 s.
Trigger Delay by Events –
1 to 10,000,000 Events.
6
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
Digital Phosphor Oscilloscopes
TDS7000B Series
Waveform Measurements
Amplitude – Amplitude, High, Low, Maximum, Minimum, Peak-to-Peak, Mean, Cycle Mean, RMS, Cycle RMS, Positive Overshoot, Negative Overshoot. Time – Rise Time, Fall Time, Positive Width, Negative Width, Positive Duty Cycle, Negative Duty Cycle, Period, Frequency, Delay.
Combination – Area, Cycle Area, Phase, Burst Width. Histogram-related – Waveform Count, Hits in box,
Peak hits, Median, Maximum, Minimum, Peak-to­Peak, Mean (µ), Standard Deviation (σ), µ+1σ, µ+2σ, µ+3σ. Eye Pattern-related (B models only) – Extinction Ratio (absolute, % and dB), Eye Height, Eye Top, Eye Base, Eye Width, Crossing %, Jitter (Peak-to-Peak, RMS and 6σ), Noise (Peak-to-Peak and RMS), S/N ratio, Cycle Distortion, Q-factor.
Waveform Processing/Math
Algebraic Expressions – Define extensive algebraic expressions including waveforms, scalars and results of parametric measurements e.g., (Integral (CH.1-Mean(CH.1)) x 1.414). Arithmetic – Add, subtract, multiply, divide wave­forms and scalars.
Relational – Boolean result of comparison >, <, ≥, ≤, ==, !=.
Calculus – Integrate, differentiate. Frequency Domain Functions – Spectral magnitude
and phase, real and imaginary spectra. Vertical Units – Magnitude: Linear, dB, dBm; Phase: Degrees, radians. Window Functions – Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential. Waveform Definition – As arbitrary math expression.
Display Characteristics
Display Type – Liquid crystal active-matrix color display.
Display Size – Diagonal: 264 mm (10.4 in.). Display Resolution – TDS7104/TDS7054:
640 horizontal x 480 vertical pixels. TDS7154B/TDS7254B/TDS7404B/TDS7704B: 1024 horizontal x 768 vertical pixels. Waveform Styles – Vectors, Dots, Variable Persistence, Infinite Persistence.
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
7
Digital Phosphor Oscilloscopes
TDS7000B Series
Computer System and Peripherals
CPU – TDS7104/TDS7054: Intel Celeron processor, 850 MHz. TDS7154B/TDS7254B/TDS7404B/TDS7704B: Intel Pentium IV processor, 2.8 GHz PC System Memory – 1GB
*2
.
*2
.
Hard Disk Drive – 40 GB removable hard disk drive: rear-panel or (B models only) front-panel, (Option FHD). Floppy Disk Drive – 1.44 MB 3.5 in. floppy disk drive: front-panel, or (B models only) rear-panel (Option FHD). CD-R/W Drive – Rear-panel CD-R/W drive with CD creation software application.
Mouse – Thumb wheel model included, USB interface. Keyboard – Mini keyboard included (fits in pouch);
PS-2 interface. Order 119-6633-00 for full-size keyboard; USB interface and hub.
*2
Available September 2004.
Input/Output Ports
Probe Compensator Output – Front panel BNC connector, requires Probe Cal-Deskew Fixture (included) for probe attachment. Amplitude 200 mV (TDS7104/TDS7054) or 500mV (B models) ±20% into a 50 load, frequency 1 kHz ±5%. Analog Signal Output Amplitude – Front-panel BNC connector, provides a buffered version of the signal that is attached to the Ch 3 input when Ch 3 is selected as trigger source. 20 mV/div ±20% into a 1.8 Mload, 10 mV/div ±20% into a 50 Ω load.
Analog Signal Output Bandwidth, Typical –
TDS7054, TDS7104: 100 MHz into a 50 Ω load. TDS7154B/TDS7254B/TDS7404B/TDS7704B: 1 GHz into a 50 Ω load. External Time Base Reference In – Rear-panel BNC connector, time base system can phase-lock to external 10 MHz reference. Time Base Reference Out – Rear-panel BNC connector, accepts TTL-compatible output of internal 10 MHz reference oscillator. Auxiliary Output Levels – Front-panel BNC connector, provides a TTL-compatible, polarity switchable pulse when the oscilloscope triggers.
Parallel Port – IEEE 1284, DB-25 connector.
Audio Ports – Miniature phone jacks for stereo
microphone input and stereo line output. USB Port – Allows connection or disconnection of USB keyboard and/or mouse while oscilloscope power is on. B models have 2 USB ports.
Keyboard Port – PS-2 compatible. Mouse Port – PS-2 compatible. LAN Port – RJ-45 connector, supports 10Base-T
and 100Base-T.
Serial Port – DB-9 COM1 port. Windows Video Port – 15 pin D-Sub connector on
the rear panel; connect a second monitor to use dual-monitor display mode. Video is DDC2B compliant.
GPIB Port – IEEE 488.2 standard. Scope Video Port – 15 pin D-Sub connector
on the rear panel, video is IBM XGA compatible on B models. Connect to show the oscilloscope display, including live waveforms on an external monitor or projector.The primary Windows desktop can also be displayed on an external monitor using this port.
Power Source
Power – 100 to 240 V
±10%, 400 Hz; CAT II, <300 W (450 VA).
115 V
RMS
, ±10%, 50/60 Hz;
RMS
8
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
Digital Phosphor Oscilloscopes
TDS7000B Series
Physical Characteristics Benchtop Configuration
Dimensions mm in.
Height 277 10.9 Width 455 17.9 Depth 425 16.75
Weight kg lbs.
Net 19.1 42.0 Shipping 37 85
Physical Characteristics Rackmount Configuration
Dimensions mm in.
Height 277 10.5 Width 502 19.75 Depth 486 19.125
Weight kg lbs.
Net 18.6 41 Kit 5.6 12.25
Mechanical
Cooling - Required Clearance
mm in.
Top 0 or >76 0 or >3 Bottom 0 0 Left side 76 3 Right side 76 3 Front 0 0 Rear 0 0
Environmental
Temperature –
Operating: 0 ºC (TDS7104/TDS7054) or +5 ºC (B models) to +50 ºC, excluding floppy disk and CD-R/W drives; +10 ºC to +45 ºC, including floppy disk and CD-ROM drives. Nonoperating: –22 ºC to +60 ºC.
Humidity –
Operating: 20% to 90% relative humidity with a maximum wet bulb temperature of +29 ºC at or below +50 ºC, noncondensing. Upper limit derated to 25% relative humidity at +50 ºC. Nonoperating: With no diskette in floppy disk drive. 20% to 90% relative humidity with a maximum wet bulb temperature of +29 ºC at or below +60 ºC, noncondensing. Upper limit derated to 20% relative humidity at +60 ºC.
Altitude –
Operating: 10,000 ft. (3,048 m). Nonoperating: 40,000 ft. (12,190 m).
Random Vibration –
Operating: 0.000125 G 350 Hz, –3 dB/octave from 350 to 500 Hz,
0.0000876 G
RMS
.
of 0.24 G Nonoperating: 0.0175 G –3 dB/octave from 100 to 200 Hz, 0.00875 G from 200 to 350 Hz, –3 dB/octave from 350 to 500 Hz, 0.006132 G
RMS
.
of 2.28 G
2
/Hz from 5 to
2
/Hz at 500 Hz. Overall level
2
/Hz from 5 to 100 Hz,
2
/Hz at 500 Hz. Overall level
2
Electromagnetic Compatibility – 89/336/EEC. Safety – UL 3111-1, CSA 1010.1, EN61010-1.2
IEC 61010-1.
/Hz
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
9
Digital Phosphor Oscilloscopes
TDS7000B Series
Ordering Information
TDS7054
500 MHz Digital Phosphor Oscilloscope.
TDS7104
1 GHz Digital Phosphor Oscilloscope.
TDS7104 and TDS7054 include: (4) P6139A 500 MHz, 10x Passive Probes, accessory pouch, front cover, USB mouse, USB mini-keyboard, probe calibration and deskew fixture (067-0405-xx), quick reference kit (020-2404-xx), user manual (071-1035-xx), TDS7000 Series product software CD-ROM, TDS7000 Series operating system restoration CD-ROM, TDS7000 Series optional applications software CD-ROM, performance verifi­cation procedure PDF file, GPIB programmer's reference (on product software CD-ROM), calibra­tion certificate documenting NIST traceability, 2 540-1 compliance and ISO9000, power cord, one year warranty.
TDS7154B
1.5 GHz Digital Phosphor Oscilloscope.
TDS7254B
2.5 GHz Digital Phosphor Oscilloscope.
TDS7404B
4 GHz Digital Phosphor Oscilloscope.
TDS7704B
7 GHz Digital Phosphor Oscilloscope.
TDS7154B, TDS7254B, TDS7404B and TDS7704B Include: Accessory pouch, front cover,
mouse, user manual (071-1226-xx), quick reference kit (020-2519-xx), TDS7000B Series product software CD-ROM 063-3632-00 (TDS7154/7254/7404B) 063-3633-00 (TDS7704B), TDS7000B Series operating system restoration CD-ROM, TDS7000B Series optional applications software CD-ROM, performance verification procedure PDF file, GPIB programmer’s reference (on product software CD­ROM), calibration certificate documenting NIST traceability, 2 540-1 compliance and ISO9000, power cord, one year warranty.
For TDS7154B and TDS7254B Only, Also Includes: (4) TekConnect
(TCA-BNC), (2) TekConnect high-impedance buffer amplifiers (TCA-1MEG), and deskew fixture (067-0405-xx).
For TDS7404B and TDS7704B Only, Also Includes: (4) TekConnect to SMA adapters (TCA-SMA).
For TDS7404B Only, Also Includes: Deskew fixture
(067-0405-xx).
TDS7704B Only,Also Includes: Deskew fixture (067-0484-xx).
Please specify disk drive and power cord option when ordering.
®
to BNC adapters
Instrument Options
Power Plug Options
Opt. A0 – North America power.
Opt. A1 – Universal EURO power.
Opt. A2 – United Kingdom power.
Opt. A3 – Australia power.
Opt. A5 – Switzerland power.
Opt. A6 – Japan power.
Opt. A99 – No power cord or AC adapter.
Opt. A10 – China power.
Mounting Options
1K – K4000 Oscilloscope Cart.
1R – Rackmount Kit.
Disk Drive Options (for TDS7154B, TDS7254B, TDS7404B and TDS7704B only)
Opt. FHD – Front-panel 40 GB removable hard disk drive, replaces floppy disk drive that goes on the rear-panel.
Service Options
Opt. C3 – Calibration Service 3 Years.
Opt. C5 – Calibration Service 5 Years.
Opt. D1 – Calibration Data Report.
Opt. D3 – Calibration Data Report 3 Years
(with Option C3).
Opt. D5 – Calibration Data Report 5 Years (with Option C5).
Opt. R3 – Repair Service 3 Years.
Opt. R5 – Repair Service 5 Years.
Recommended Accessories
Probes
P7380 – >8 GHz Z-Active™Differential Probe.
P7380SMA – >8 GHz Differential Signal
Acquisition System.
P7350 – 5 GHz differential probe recommended for TDS7404B/TDS7704B.
P7350SMA – 5 GHz SMA Input differential Probe.
P7260 – 6 GHz active probe recommended for
TDS7404B/TDS7704B.
P6158 – 3 GHz, 20x Low C Probe.
P6247 – 1.0 GHz Differential Probe.
P6139A – 500 MHz, 10x Passive Probe.
P6245 – 1.5 GHz Active Probe.
P6248 – 1.7 GHz Differential Probe.
P7240 – 4 GHz Active Probe.
P7330 – 3.5 GHz Differential Probe.
Adapters
TCA-1MEG – TekConnect high-impedance buffer amplifier.
TCA-SMA – TekConnect-to-SMA Adapter.
TCA-N – TekConnect-to-N Adapter.
TCA-BNC – TekConnect-to-BNC Adapter.
TCA75 – 4 GHz precision TekConnect 75 to
50 adapter with 75 BNC input connector.
AFTDS – Telecom differential electrical interface adapter (for line rates <8 MB/s; requires TCA-BNC adapter for TDS7404B).
Cables
GPIB Cable (1 m) – Order 012-0991-01.
GPIB Cable (2 m) – Order 012-0991-00.
RS-232 Cable – Order 012-1298-00.
Centronics Cable – Order 012-1214-00.
Test Fixtures
TDSUSBF – TDSUSB test fixture for use with Opt. USB.
Software
WSTRO – WaveStar™waveform capture and documentation software.
Miscellaneous
Keyboard (USB Interface) – Order 119-6633-00.
Service Manual – TDS7054/TDS7104:
Order 071-0711-xx.
TDS7154B/TDS7254B/TDS7404B/TDS7704B: Order 071-0898-xx.
Transit Case – Order 016-1522-00.
10
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
Digital Phosphor Oscilloscopes
TDS7000B Series
Options (available on models indicated by “x”)
TDS7054 TDS7104 TDS7154B TDS7254B TDS7404B TDS7704B
Acquisition Memory Options
2M 8 Msamples max, x x x x x x
2 Msamples/ch
3M 16 Msamples max, x x x x x x
4 Msamples/ch
4M 32 Msamples max, x x x x
8 Msamples/ch
5M 64 Msamples max, x x x x
16 Msamples/ch
Software Options
DVI TDSDVI DVI Compliance x x x
Test Solution
DVD TDSDVD Optical x x x x x x
Storage Analysis
ET3 TDSET3 Ethernet Compliance x x x x x x
Test Software
JA3 TDSJIT3 Advanced Jitter x x x x x x
Analysis Software
JE3 TDSJIT3 Essentials x x x x x x
J2 TDSDDM2 Disk Drive x x x x x x
Analysis Software
CP2*1TDSCPM2 ANSI/ITU Telecom x x x x x x
Pulse Compliance Testing Software
USB*2TDSUSBS USB2.0 x x x x x x
Compliance Test S/W Only
SM Serial Communications x x x x x x
Mask Testing
ST Serial Pattern Trigger x x x x
PW3 TDSPWR3 Power Measurement x x x x x x
and Analysis Software
RTE Serial Data Compliance and x x x x
Analysis Software
PCE*3PCI Express™Compliance xx
Module for Option RTE
IBA*3InfiniBand Compliance xx
Module for Option RTE
*1Requires Option SM.
2
Requires Option TDSUSBF (USB Test Fixture).
*
3
Requires Option RTE.
*
To view instrument upgrades for the TDS7000 and TDS7000B Series, please go to www.tektronix.com/tds7000b_upgrades.
Digital Phosphor Oscilloscopes • www.tektronix.com/oscilloscopes
11
Digital Phosphor Oscilloscopes
TDS7000B Series
Contact Tektronix:
ASEAN / Australasia (65) 6356 3900
Austria +41 52 675 3777
Balkan, Israel, South Africa and other ISE Countries +41 52 675 3777
Belgium 07 81 60166
Brazil & South America 55 (11) 3741-8360
Canada 1 (800) 661-5625
Central East Europe, Ukraine and the Baltics +41 52 675 3777
Central Europe & Greece +41 52 675 3777
Denmark +45 80 88 1401
Finland +41 52 675 3777
France +33 (0) 1 69 86 81 81
Germany +49 (221) 94 77 400
Hong Kong (852) 2585-6688
India (91) 80-22275577
Italy +39 (02) 25086 1
Japan 81 (3) 6714-3010
Luxembourg +44 (0) 1344 392400
Mexico, Central America & Caribbean 52 (55) 5424700
Middle East, Asia and North Africa +41 52 675 3777
The Netherlands 090 02 021797
Norway 800 16098
People’s Republic of China 86 (10) 6235 1230
Poland +41 52 675 3777
Portugal 80 08 12370
Republic of Korea 82 (2) 528-5299
Russia & CIS +7 (495) 7484900
South Africa +27 11 254 8360
Spain (+34) 901 988 054
Sweden 020 08 80371
Switzerland +41 52 675 3777
Taiwan 886 (2) 2722-9622
United Kingdom & Eire +44 (0) 1344 392400
USA 1 (800) 426-2200
For other areas contact Tektronix, Inc. at: 1 (503) 627-7111
Updated 12 May 2006
Our most up-to-date product information is available at:
www.tektronix.com
Product(s) are manufactured
in ISO registered facilities.
Copyright © 2006, Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publi­cation supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trade­marks or registered trademarks of their respective companies.
07/06 JS/WOW 55W-13766-11
Loading...