Atec SUNSET-T3 User Manual

SunSetTM T3
April 2001
SPECIFICATIONS
Connectors
DS3 Receive/Transmit: BNC DS3 External Clock Input: Coax SMC, TTL DS1/E1 Receive/Transmit: Bantam DS1/E1 External Clock Input: Bantam, AMI, 0 to -30 dB Serial Port: 8-pin Mini DIN RS232C (V.24), DTE DC power
Status/Alarm Indicators
DS3: Pulses, Idle, Errors, M13 Frm, C-Bit Frm, AIS, Yel
Alm (X-bit), FEBE DS2: Frame DS1: Pulses, B8ZS, Errors, SF, ESF, SLC-96, Yel Alm, AIS E1: Pulses, HDB3, Errors, PCM-30, PCM-31, CRC det,
Alarm, AIS General: Pat Sync, Power, Battery
DS3 General
Framing: Unframed, M13, C-bit parity. Conforms to
ANSI T1.102, 107, 107A, 403, and 404. Also Telcordia
TR-TSY-000009 and TR-TSY-000191. Line Coding: B3ZS
Clock Source: 44.736 MHz, External (± 300 ppm, TTL,
50% ± 1% duty cycle), Internal (± 5 ppm), Loop (±
300 ppm) Standard Test Patterns: 1111, 1100, 1010, 2 User Programmed Patterns: 10 programmable 24-bit
patterns with alphanumeric names Test Pattern Inversion Error Injection: Logic, BPV, Logic+BPV, C-bit, P-bit
parity, FEBE, Frame, Burst or Rate Alarm Generation: AIS, Yellow, Idle Loopbacks: FEAC loopbacks per ANSI T1.401, M13 C-bit
loopback per TR-TSY-000009 (requires SW361) FEAC transmit/receive per ANSI (requiress SW301)
15
-1, 220-1, 223-1
DS1 General (Requires SW310)
Signal Directions: Multiplexed to DS3 jacks or to DS1 jacks
Clock Source: Internal (± 5 ppm), Loop (recovered, ± 300
ppm), External (± 300 ppm, 0 to -30 dB resistive)
Framing: Unframed, Superframe (SF-D4), ESF, SLC-96*.
Conforms to ANSI T1.102, 107, 107A, 403, and 404. Also Telcordia TR-TSY-000009 and TR-TSY-000191.
*SLC is a registered trademark of AT&T. Line Coding: AMI, B8ZS Standard Test Patterns: All 1s, All 0s, Alt 10, 1100, 1-in-8
(1:7), 1-in-16, 3-in-24, Quasi-Random Signal (QRS),
6
-1, 27-1, 29-1, 211-1, 215-1, 220-1, 223-1, 55 Daly, T1-1
2
through T1-6, DDS-1, DDS-2, DDS-3, DDS,4, DDS-6
(Idle, Yellow, 2-8, FOX) User Programmed Patterns: 10 programmable 2048-bit
patterns with alphanumeric names Test Pattern Inversion: All Standard Test Patterns and
User Programmed Patterns Error Injection: Logic, BPV, Logic+BPV, Frame, Burst or Rate Alarm Generation: AIS, Yellow, Idle Fractional T1: Any arbitrary combination of 1 to 24
channels. Nx56k or Nx64k format. Autoconfigure to
active channels. Requires SW311. Loopbacks: CSU/NIU loop up/down, Inband, ESF datalink,
programmable 32-bit control. M13 C-bit loopbacks
per Telcordia TR-TSY-000009. DS3/DS1 based FEAC loopbacks per ANSI T1.404
DS1 Transmitter
Pulse Shape: Conforms to ITU-T G.703, Telcordia TR-TSY-
000499 Output Levels: 0, -7.5, -15, -20 dB
. . . a step ahead
DS3 Transmitter
Transmit Signal Source: DS3 Test pattern, DS1 Test
pattern broadcast, DS1 AIS broadcast, loop received DS3 signal
Pulse Shape: Conforms to ITU-T G.703, Telcordia TR-TSY-
000499. High, DSX, Low
DS1 Insert: Insert DS1 on desired channel. Other
channels have DS1 test pattern copies or AIS. DS1 generated internally or from DS1 RX connector
E1 Insert: Insert E1 on desired channel. Other channels
have AIS. E1 generated internally.
DS3 Receiver
Input Impedance: 75
Input Sensitivity
DSX: Up to 26 dB resistive or 6 dB cable loss from DSX
High/low: +6 dB to -26 dB resistive loss Jitter tolerance: Conforms to Telcordia TR-TSY-000009 Auto Configure to received signal, line coding, & test pattern T1/E1 Drop: Drop to internal receiver or drop to DS1 TX
connector
SunSetTM T3
DS1 Receiver
Input Frequency: 1.544 Mbps, ± 300 ppm Input Impedance: 100, +6 dB to -36 dB External Clock Input: 1.544 Mbps, ± 300 ppm, 0 to -30 dB resistive
with ALBO
Auto Configure to received signal, Line Coding, Test Pattern
E1 2.048 Mbps (Requires SW324)
Drop and insert one E1 channel to/from a DS3 Transmit and receive at E1 interface Transmit
Pulse Shape: Conforms to ITU-T G.703, 3.0V ± 10% Clock: De-jittered from DS3, Internal 2.048 Mbps ± 5 ppm
Line coding: AMI, HDB3
Receive
Impedance: 120, +6 to -20 dB
Line coding: AMI, HDB3 Framing: PCM-30 and PCM-31 with or without CRC, unframed
Test Patterns
Standard Patterns: All 1s, All 0s, Alt 10, 1-in-8 (1:7), 3-in-24, QRS,
6
-1, 27-1, 29-1, 211-1, 215-1, 220-1, 223-1, 1100 (FOX, 2-in-8,
2 Yellow, Idle, User Patterns)
User Programmed Patterns: 10 ea patterns up to 2048 bits long,
alphanumeric name up to 10 characters for each pattern Test Pattern Inversion Auto Configure to received signal, line coding, test pattern Fractional E1: Any arbitrary combination of 1 to 31 channels. Nx64k
format. Autoconfigure to active channels. Requires SW311.
Other Measurements
View Received Data
View T1 data in binary, hex, ASCII formats Displays data in bytes by timeslot Displays 8 timeslots per display page Capture & store 256 consecutive timeslots as test pattern, 10 patterns
Propagation Delay
Measure round trip propagation delay in unit intervals ± 1 UI, with
translation to microseconds and one way distance over cable
Bridge Tap
Automated transmission and measurement of 21 different patterns to identify possible bridge taps at some point on a T1 line
Quick Test I and II
2 programmable automated loopback tests that save time when
performing standardized acceptance tests 10 character alphanumeric ticket name Automatically loopback a CSU or NIU device; automatically drop the
loopback at conclusion of test Automatically print results at conclusion of test Specify 5 independent test patterns, run each pattern for 1 to 999 min Operate in single-run or continuous-run mode
Protection Switch Timing
Measure the duration a switch or multiplexer takes to perform the protective switching function
Measurements
G.821 and general errors: Bit error, bit err rate, errored seconds,
%errored seconds, severely errored seconds, %severely errored seconds, error-free seconds, %error-free seconds, available seconds, unavailable seconds, synch loss seconds, degraded minutes
DS3: Frame loss seconds, loss of signal seconds, BPV, BPV rate, Frame-
bit error, Frame-bit error rate, P-bit error, C-bit error, FEBE, available seconds, errored seconds, %errored seconds, severely errored seconds, %severely errored seconds, error-free seconds, %error-free seconds, unavailable seconds, degraded minutes, AIS seconds, yellow alarm seconds, frequency, max frequency, min
frequency, peak voltage (V), power (dBm) DS2: F-bit error, frame loss seconds, AIS seconds, Yellow Alarm seconds DS1: BPV, BPV rate, Frame-bit error, Frame-bit error rate, CRC-6 block
error, CRC-6 block error rate, out of frame count, change of frame
alignment count, errored seconds, %errored seconds, severely errored
seconds, %severely errored seconds, error-free seconds, available
seconds, degraded minutes, unavailable seconds, frequency, AIS
seconds, loss of frame seconds, loss of signal seconds, yellow alarm
seconds, low density seconds, excess zeroes seconds, max frequency,
min frequency, +1-peak voltage frame slip, +1-wander peak level E1: Code violation (BPV), code violation rate, FAS error, FAS error rate,
MFAS error, MFAS error rate, CRC error, CRC error rate, errored
seconds, %errored seconds, severely errored seconds, %severely
errored seconds, error-free seconds, available seconds, degraded
minutes, unavailable seconds, AIS seconds, loss of frame seconds,
loss of signal seconds, FAS alarm seconds, MFAS alarm seconds,
peak voltage (V), frequency, max frequency, min frequency, + wander,
- wander, peak level (dB), clockslip
Loopbacks
Loopback Control, In-band CSU, NIU, 100000 Loopback Control, ESF-Facility Datalink 10 programmable user codes, 1 to 32 bits each
Remote Control (SW302)
To VT100 terminal or PC running terminal emulation Status table provides current & historical information on test sets' LEDs Uses test set's serial port, 8-pin MINI DIN connector, RS232C Serial port cannot be connected to printer during remote control
operation
Westell PM NIU and MSS (SW303)
Supports Westell performance monitoring network interface unit and
maintenance switch system with ramp Set/query NIU time and date Query performance data by hour or for all accumulated data Reset performance registers Read data over ramp line Perform maintenance switch function for Westell and Teltrend Automated looping of Westell and Teltrend line and central office
repeaters: SF and ESF modes supported Arm, loop up/down, loopback query, sequential loopback, power loop
query, span power up/down, unblocking Requires SW310
Fractional T1 (SW311)
Error measurements, channel configuration verification Nx64 kbps, Nx56 kbps, N=1 to 24 Sequential, alternating, or random channels Set Tx and Rx channels independently Auto scan and auto configure to any FT1 order for active channels Selectable idle channel code, 7F or FF hex Requires SW310
ESF and SLC-96 Datalink send and Receive (SW312)
ESF Datalink Read and Send T1.403 message on FDL (PRM and BOM) Automatic HDLC protocol handling YEL ALM, LLB ACT, LLB DEA, PLB ACT, PLB DEA T1.403 24 hour PRM collection per 15 min interval SLC-96 Datalink Send and receive message WP1, WP1B, NOTE formats Alarms, switch-to-protect, far end loop To Telcordia TR-TSY-000008 specifications, modes I and III SLC-96 FEND loop Requires SW310
CSU/NI Emulation (SW313)
Graphical indication of signal status Simultaneous display of T1 line measurements Automatic generation of AIS Loopbacks
Responds to remote loopback commands, in-band and out-of-
band (ESF datalink T1.403)
Establish Line and payload loopback from keypad
Requires SW310
ISDN PRI Call Setup and Analysis (SW323)
D-channel message monitor Filter type: Call reference, caller number, called number Voice and data call setup and receive Talk/listen for voice calls 56k, 64k data rates Data patterns: 2047, 511, 127, 63, All 1s, All 0s, or 8-bit user pattern Programmable called and caller numbers, B-channel number, NSF
code, NSF type NT, TE emulation Programmable D-channel number AT&T 5ESS and Northern Telecom DMS-100 compatible On-screen table for optional call feature programming Requires SW310
GENERAL
SW options upgradeable via software in-field cartridge replacement Printer: Print every 2 to 99 minutes, print at end of measurement,
print on error/alarm events, print screen alphanumerics Size: 4 x 2.4 x 10.5" [10.5 x 6 x 27 cm] Weight: 2.8 lb [1.3 kg] SS300e chassis only
Built-in NiMH rechargeable battery pack Battery operating time: 90 min nominal. AC operation with 100
to 240 VAC, 50/60 Hz universal charger. Operating temperature: 32˚F to 122˚F [0˚C to 50˚C] Storage temperature: -4˚F to 158˚F [-20˚C to 70˚C] Humidity: 5% to 90% noncondensing
Voice Frequency Capability (SW320)
General: Talk/listen with volume control, 24 channel signaling bit
display, control signaling bits, view channel data, µ/A law to DS3
or DS1/E1 ports Specify trunk type: E&M, ground/loop start, FXO, FXS, user defined Specify supervision on idle channels Basic Transmission Impairment Measurements: Level, frequency, C-
message noise, C-notched noise, 3 kHz flat filter noise, signal to
noise with 1004 Hz tone. Generate 50 to 3950 Hz ±1 Hz, 1 Hz
steps, +3 to -60 dBm, 1 dB steps. Requires SW321. Addressing
DTMF/MF/DP dialing, programmable dial number up to 32 digits,
10 stored numbers, programmable transmit level -5 to -25 dBm
MF/DTMF dialing: Specify dial period, silent period from 50 ms to
999 ms
DP dialing: Specify %break from 40 to 60, interdigit period from
200 ms to 900 ms
Measure MF/DTMF high/low frequency, level, twist, digital time,
interdigital time
Measure DP pulses per second, %break Requires SW322
ORDERING INFORMATION
Test Set
SS300e SunSet T3 Chassis
Includes SunSet T3 Chassis, 100 VAC to 240 VAC Universal Battery Charger, 6-cell NiMH battery, SunSet T3 User’s Manual, SunSet T3 Field Manual, Software Cartridge, Instrument Stand. Software Cartridge includes basic T3 testing operations.
Software Options
SW301 DS3 FEAC
Provides control and analysis of the DS3 FEAC data link in C-bit parity framing format.
SW302 Remote Control
Allows menu-driven remote control of basic test functions using a dumb terminal or personal computer equipped with VT100 terminal emulation software. Includes printer cable and null modem adapter.
SW303 Maintenance Switch, Performance Monitoring NIU, RAMP,
Looping Repeaters. Provides menu-driven support for the Westell & Teltrend looping repeaters, Maintenance Switch, and Performance Monitoring NIU, including the RAMP feature. Requires SW310.
SW310 DS1 Testing
Provides DS1 test capability through the bantam jacks on the set. Also provides DS1 drop & insert test capability through the WECO 560-style jacks on the set. DS1 capabilities include a broad variety of test patterns, DS1 NIU & CSU loopback operations, basic DS1 measurements, view received data, quick test, bridge tap test.
SW311 Fractional T1
Requires SW310
SW312 ESF and SLC-96 Datalink Send and Receive
Requires SW310
SW313 CSU/NIU Emulation
Requires SW310
SW320 DS0 Drop/Insert
Provides voice frequency talk/listen/tone. Requires SW310.
SW321 VF Level, Freq, & Noise Measurement
Requires SW310 and SW320
SW322 MF/DTMF/DP Dialing, Decoding, and Analysis
Requires SW310 and SW320
SW323 ISDN PRI Call Setup & Analysis
Requires SW310
SW324 E1 Test Capability
From a DS3, drop and insert an E1 signal through the test sets’ DS1 bantam jacks, or test an E1 signal directly through the DS1 bantam jacks. Requires the SS300e chassis. Includes Fractional E1.
SW2501 1 Mb Software Replacement Cartridge
Specify model and serial number.
Accessories
SS101 Carrying Case SS104 Cigarette Lighter Battery Charger SS105 Repeater Extender SS106 Single Bantam to Single Bantam Cable, 6' SS108 Single Bantam to Single 310 Cable, 6' SS109 Single Bantam to Probe Clip Cable, 6' SS110 Dual Bantam to 15-pin D Connector Cable (m), 6' SS111 Dual Bantam to 15-pin D Connector Cable (f), 6' SS112 Dual Bantam to 8-position Modular Plug Cable
Fits RJ-48 jacks per ANSI T1.403, 6'. Used for NIUs (smart jacks).
SS115 DIN-8 to RS232C Printer Cable
Replacement printer cable for earlier serial printers such as SS118.
SS115D DIN-8 to DB-9 Printer Cable
Included when SW302 or SS118B/C is ordered. SS116 Instrument Stand SS117A Printer Paper, 5 rolls, for SS118B/C SS118B High Capacity Thermal Printer. With internal
rechargeable battery. Includes cable (SS115B)
for connection to SunSet &110 VAC charger. SS118C High Capacity Thermal Printer. With internal
rechargeable battery. Includes cable (SS115B)
for connection to SunSet & 220 VAC charger.
SS121B SunSet AC Charger, 220 VAC, 50/60 Cycle.
Provides continuous operation from 220 VAC source. Provides 0.6A output at 12 VDC. Charges battery. 2-stage operation for fast recharge then slow trickle charge. 3-prong IEC connector. For SS300 chassis only.
SS122 Null Modem Adapter
Replacement null modem adapter for earlier serial printers such as SS118.
SS122B Null Modem Adapter
DTE to DCE conversion, DB-9 to DB-9. Included with SW302
SS123A SunSet Jacket
Provides additional weather protection for SunSets. Rugged padded synthetic fabric.
SS123C SunSet Jacket, Large - Provides additional
weather protection for SunSets. Only for use with SS143B (SS123B included)
SS128A 120V/12V 1.2A SunSet Charger
For USA and Canada. Provides continuous operation from 120 VAC source. Provides 1.2A output at 12 VDC. Charges battery. 2-stage operation for fast recharge then slow trickle charge. For SS300 chassis only.
SS128B 110V/12V 1.2A SunSet Charger
For Taiwan and Korea. Provides continuous operation from 110 VAC source. Provides 1.2A output at 12 VDC. Charges battery. 2-stage operation for fast recharge then slow trickle charge. For SS300 chassis only.
SS132 Two Single Bantams to 4-position Modular
Plug Cable. Used for downloading performance monitoring information from a Westell NIU at the front panel jack without disrupting service.
SS138D SunSet AC Charger, 100 to 240 VAC, 50/60 Hz
input, 15 VDC @ 2A output. For SS300e chassis only.
SS139 6-cell NiMH Battery Pack
7.2 VDC, 1.8 Ahr. For SS300e chassis only. Requires factory installation.
SS143B SunSet Rubber Holster
SS212 Conversion cable, BNC (m) 75to bantam 120, 6’
SS300W SunSet T3 Extended Warranty. Extends standard
1 yr warranty period to 3 yr. Excludes battery and accessories, which are warranted for 1 yr
SS302 WECO 440A to WECO 440A (miniature style)
Coaxial Cable, 6', fits in 560A jack SS303 WECO 440A to BNC Coaxial Cable, 6' SS304 WECO 440A (mini) to 358A (large) Coaxial
Cable, 6' SS305 SunSet T3 User’s Manual SS309 SunSet T3 Training Tape, English
(specify SS309K for Korean) SS315 BNC to WECO 358A Cable, 6’
L
E
E
C
T
O
E
M
S
I
,
R
I
N
N
U
S
I
S
O
3
9
6
0
A
0
-
Note: Specifications subject to change without notice. © 2001 Sunrise Telecom Incorporated. All rights reserved. Printed in USA.
1
22 Great Oaks Blvd.
C
.
0
8
San Jose, CA 95119 ph 1 408 363 8000
fax 1 408 363 8313
info@sunrisetelecom.com
www.sunrisetelecom.com
Loading...