Atec F6150SV User Manual

CONVERTIBLE AMPLIFIERS
Current Mode
Convertible Source AC Ranges Convertible Source DC Ranges Power Resolution AC Ranges Resolution DC Ranges
6 X 0.5, 1.0 A RMS (L-N) 6 X 0.354, 0.707 A DC 6 X 75VA / 75 W 0.0001 A 0.0001 A
3 X 0.5, 1.0, 2.0 A RMS (L-N) 3 X .354, 0.707, 1.41 A DC 3 X 150VA / 150 W 0.0001 A 0.0001 A
1 X 1.5, 3.0, 6.0 A RMS (L-N)
S1 ǁ S2ǁ S3
S1 ǁ S2ǁ S3
1 X 450VA / 450 W
S1 ǁ S2ǁ S3
0.001 A 0.001 A
Current Transient Mode
Convertible Source AC Ranges Convertible Source DC Ranges Power Resolution AC Ranges Resolution DC Ranges
6 X 0.75, 1.5 A RMS (L-N) 6 X 0.53, 1.06 A DC 6 X 97.5VA / 97.5 W 0.0001 A 0.0001 A
3 X 0.75, 1.5, 3.0 A RMS (L-N) 3 X 0.53, 1.06, 2.12 A DC 3 X 195VA / 195 W 0.0001 A
1 X 2.25, 4.5, 9.0 A RMS (L-N)
S1 ǁ S2ǁ S3
S1 ǁ S2ǁ S3
1 X 585VA / 585 W
S1 ǁ S2ǁ S3
0.001 A 0.001 A
(0.0001 A) @ 0.53, 1.06 A DC
(0.001 A) @ 2.12 A DC
Voltage Mode
Convertible Source AC Ranges Convertible Source DC Ranges Power Resolution AC Ranges Resolution DC Ranges
6 X 75, 150V RMS (L-N) 6 X 106, 212V DC 6 X 75VA/ 75W 0.01 V
3 X 75, 150, 300V RMS (L-N) 3 X 106, 212, 424V DC 3 X 150VA / 150 W 0.01 V
1 X 150, 300, 600V RMS (L-L)
S1 & S2
1 X212, 424, 848V DC
S1 & S2
1 X 300VA / 300 W
S1 & S2
0.01 V 0.1 V DC
(0.01 V) @ 106V DC
(0.1 V) @ 212V DC
(0.01 V) @ 106V DC
(0.1 V) @ 212, 424V DC
AC Ranges DC Ranges Power Resolution AC Ranges Resolution DC Ranges
6 X 8.75, 17.5, (35)* A RMS (L-N) 6 X 5.83, 11.7, (23.3)* A DC
3 X 8.75, 17.5, 35,(70)*
A RMS (L-N)
1 X 8.75, 17.5, 26.25,52.5, 105,
(210)* A RMS (L-N)
S1 ǁ S2ǁ S3
* Maximum power delivered at high source range
AC Amplitude Accuracy @ 50-60 Hz
@ 20° - 30° C
Typical Guaranteed
0.02% of reading + .01% of range
0.09% of reading +
3 X 5.83, 11.7, 23.3,(46.6)* A DC
1 X 5.83, 11.7, 17.5, 35,70, (140)*
A DC
S1 ǁ S2ǁ S3
.04% of range
(+359.9°) -(0°) -
Range Accuracy Resolution
(-359.9°)
Convertible Source in Current Mode @ 20° - 30° C
Guaranteed
<0.5%
Typical Guaranteed
<0.02% <0.1%
ENHANCED CURRENT AMPLIFIERS
6X 87.5VA / 87.5 W;
(6 X 131.25VA /131.25 W)*
3 X 175VA / 175 W;
(3 X 262.5VA /262.5 W)*
1 X 525VA / 525 W;
(1X787.5VA/787.5 W)*
S1 ǁ S2ǁ S3
Phase Angle @ 50/60 Hz
± 0.25° ± 0.1°
Distortion @ 50/60Hz V & I Sources Total
Harmonic Distortion (THD)
0.001 A
(0.001) A @ 8.75, 17.5, 35 A RMS
(0.01) @ (70)* A RMS
(0.001) A @ 8.75,
17.5, 26.25 A RMS
(0.01) A @ 52.5, 105, (210)* A RMS
(0.001) A @ 5.83 A DC
(0.01) A @ 11.6, (23.3)* A DC
(0.001) A @ 5.83 A dc
(0.01) A @ 11.7, 23.3, (46.6)* A DC
(0.001) A @ 5.83 A DC
(0.01) A @ 11.7, 23.3, 35, 70,
(140)* A DC
Frequency
Bandwith Range Resolution
DC - 3kHz at Full
Power
DC, 0.1 Hz - 2.0 kHZ Continuous Full Load
Accuracy
Typical @ 20° - 30° C @ 0° - 50° C
0.5 ppm 1.5 ppm 10 ppm
0.001 Hz
Logic Inputs (Voltage or Contact Sense)
Total Inputs: 8*
Isolated Inputs
Inputs: 2 (First Strike)
Voltage Sense:
Open Circuit Test Voltage:
Short Circuit Test Current:
Response Time:
Input Impedance: 150KΩ Isolation: ± 500V peak
Inputs: 3 Pairs (6)
Voltage Sense:
Open Circuit Test Voltage:
Short Circuit Test Current:
Response Time:
Input Impedance: 150KΩ
Isolation: ± 500V peak
* Additional 8 inputs available with F6816 option
250V RMS AC / 300V
DC
12V DC
20mA DC
0.1 msec max
pickup /dropout
Paired Inputs
250V RMS
AC / 300V DC
4V DC
>50mA DC
0.1 msec max
pickup /dropout
Logic Outputs
Type: FET (High Speed Electronic) Relay
Number: 4 4
Isolation Voltage: ±500V peak ±500V peak
Response Time: 0.1millisecond pick up /dropout <10 millisecond pick up /dropout
Maximum (Make/ Break Current):
Input Voltage:
Metering Functions
DC Meter Inputs
Input Range: 0 - ±10V DC / 0 - ±20mA DC
Typical: <0.003%
Guaranteed: <+0.05%
AC Sources
Typical: <0.02% of metering loads
Logic Input As Counters
Frequency: 10 kHz
Pulse width: >175 µsec
0.5 amps
250 V RMS 250 V RMS
(Breaking cap AC: 2000 VA with Vmax
(Breaking cap DC: 50W with Vmax 300
Range: 6 - 300V DC
Resolution: 0.3V
Power: 90 W, 1.5 A max
50/60 Hz Ripple: <0.2% of Range
Accuracy: <± 5%
250V, Imax 8 A)
V, Imax 8A)
Variable Output Battery Simulator
(AIM) Analog Input Measurement
(F6820 Option)
Recording:
Internal Source recording:
Ranges:
Bandwidth: DC, 0-5kHz Input Impedance: 150KΩ Max Input
Voltage:
Isolation:
Typical: ±0.06%
Maximum: ±0.15%
Timers Number:
Max Recording Time:
Accuracy:
Resolution: 100 µsec
8 external Analog or
Digital Signals
12 Sources
250 mV, 2.5V, 25V,
250V RMS
250V RMA AC / 300V
DC
± 500V peak channel
to channel
Accuracy
Timing and Trigger
8
<24 Hours
±0.0005% of reading, ±50 µsec
Enclosure:
Mechanical:
Weight:
Dimensions:
Calibration:
High-impact, molded,
ame-retardant ABS-
meets National Safe
Transit Association testing
specication No.1A for
immunity to severe shock
and vibration
IEC 60068-2-27 Shock
(15g/11ms, half sine)
IEC 60068-2-6 Vibration
(10-150 Hz, 20m/s2)
IEC 60068-2-6 Drop Test
42lb,19.05kg
(front cover and strap
included)
15 X 9.5 X 18 inches,
38 X 24 X 45.7 cm
Certication traceable to
N.I.S.T. standards
Environmental:
EMC Emissions:
EMC Immunity:
Quality Assurance Management System:
Humidity:
General Specifications
IEC 60068-2-2 Dry Heat (+85°C storage; + 50°C
Rating Operating), IEC
60068-2-1 Cold
(-50°C storage; 0°C
operating), IEC 60068-2-
30 Damp Heat (+55°C,
6 cycles, 95% humidity),
NEMA Enclose Rating
Type 1IEC Enclosure IP20
FCC 47 CFR Part
15 Class A (USA), EN55011:1998/A1:1999/ A2:2002 Group 1 Class A
ISM(EU), AS/NZS CISPR
11:2004 Class A ISM
(Australia), ICES-001
Issue 3 ISM (Canada)
EN 61000-6-2:2005;
IEC 61000-4-
2/3/4/5/6/11
Third Party certication
to ISO 9001:2000
Up to 95% relative
humidity,
non-condensing
Electrostatic Discharge Immunity:
Surge Withstand Capability:
Line Power Supply:
Safety:
IEC 801-2 I.E.C. performance level 1 @ 10kV: normal
performance within
specications. I.E.C.
performance level 2 @
20kV: no permanent
damage.
ANSI/IEEE c37.90. The simulator functions as a source during surge
withstand capability
tests, when the ANSI/IEEE
specied isolating circuit
is interposed between
the simulator and the
test relay.
105-264V, 47-63 Hz
EN 61010-1; UL 61010-1;
CSA 27.2 # 61010-1
IEC61850 GOOSE:
IEC61850 Sample Values (Publishing):
Communication Interfaces (Ethernet, Wi-Fi, USB)
Certied by KEMA as
being compliant with
IEC61850 protocol
(IEC61850-7-2 and 8-1)
80 samples per cycles
for nominal frequencies
50Hz and 60Hz using
GPS time synchronized
signals
Ethernet or USB control
to PC, Wi-Fi (802.11
B+G bands, 30 - 80ft,
9 - 24m)
Doble Engineering Company
Worldwide Headquarters 85 Walnut Street Watertown, MA 02472 USA Tel: +1 617 926 4900 Fax: +1 617 926 0528
www.doble.com
MKT-SL-F6150SVTS-1/13
Loading...