ASUS ROG-STRIX-750G User Manual

Page 1
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
DUT INFORMATION
Brand Asus ROG Manufacturer (OEM) Seasonic Series Rog Strix Model Number RSSS04-750G1 (Sample #3) Serial Number K7YEKG007692KD3 DUT Notes
Asus ROG RSSS04-750G1 (Sample #3)
DUT SPECIFICATIONS
Rated Voltage (Vrms) 100-240 Rated Current (Arms) 10-5 Rated Frequency (Hz) 47-63 Rated Power (W) 750 Type ATX12V
Cooling
Semi-Passive Operation ✓ (selectable) Cable Design Fully Modular
140mm Double Ball-Bearing Fan (FB14025BH)
POWER SPECIFICATIONS
Rail 3.3V 5V 12V 5VSB -12V
Max. Power
Total Max. Power (W) 750
Amps 20 20 62 3 0.3 Watts 100 744 15 3.6
CABLES AND CONNECTORS
Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors ATX connector 20+4 pin (610mm) 1 1 18-22AWG No 4+4 pin EPS12V (1000mm) 2 2 18AWG No 6+2 pin PCIe (680mm+80mm) 2 4 18AWG No SATA (450mm+115mm+115mm+115mm) 1 4 18AWG No SATA (410mm+150mm+150mm+150mm) 1 4 18AWG No 4 pin Molex (450mm+120mm+120mm) 1 3 18AWG No AC Power Cord (1400mm) - C13 coupler (EU) 1 1 18AWG ­AC Power Cord (1370mm) - C13 coupler (British) 1 1 18AWG -
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
PAGE 1/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
Page 2
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
Asus ROG RSSS04-750G1 (Sample #3)
General Data
Manufacturer (OEM) Seasonic PCB Type Double Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV, 1x Discharge IC Inrush Protection NTC Thermistor & Relay Bridge Rectifier(s) 2xGBU1508(800V, 15A @ 100°C) APFC MOSFETS 2x InfineonIPP50R140CP(550V, 15A @ 100°C, 0.14Ohm) APFC Boost Diode 1x STMicroelectronicsSTTH8S06(600V, 8A @ 25°C) Hold-up Cap(s) 1x Hitachi (400V, 560uF, 2,000h @ 105°C,HU) Main Switchers 4x ChampionGPT10N50ADG(500V, 9.7A, 0.7Ohm) APFC Controller ChampionCM6500UNX Resonant Controllers ChampionCM6901T6
Topology
Primary side: Full-Bridge & LLC converter Secondary side: Synchronous Rectification & DC-DC converters
Secondary Side
+12V MOSFETS 4x NexperiaPSMN2R6-40YS(40V, 100A @ 100°C, 3.7mOhm @ 100°C)
5V & 3.3V
Filtering Capacitors
Supervisor IC WeltrendWT7527V(OCP, OVP, UVP, SCP, PG Fan Model Everflow FB14025BH (135mm, 12V, 0.60A, Ball Bearing Fan)
DC-DC Converters:4x ON SemiconductorNTMFS4C028N(30V, 12.3A @ 80°C, 4.73mOhm) PWM Controllers: ANPECAPW7159C
Electrolytics: 3x Nippon Chemi-Con (105°C, W), 5x Nippon Chemi-Con(4-10,000h @ 105°C,KY), 5x Nichicon (4-10,000h @ 105°C,HE) Polymers: 27x FPCAP
5VSB Circuit
Rectifier 1x PFC P10V45SP (45V, 10A) Standby PWM Controller Excelliance MOSEM8569
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 2/9
info@cybenetics.com
Page 3
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
Asus ROG RSSS04-750G1 (Sample #3)
RESULTS
Test Date 08-30-2019 Certification Date 09-07-2019 Lab ID # AS19750101 Temperature Range (°C /°F) 30-32 / 86-89.6 Average Efficiency 90.952 Efficiency With 10W (≤500W) or 2% (>500W) Load -115V 62.528 Average Efficiency 5VSB 76.485 Standby Power Consumption (W) -115V 0.0549026 Standby Power Consumption (W) -230V 0.0807103 Average PF 0.937 ErP Lot 3/6 Ready ✓ (EU) No 617/2013 Compliance ✓ Avg Noise Output 21.54 Efficiency Rating (ETA) ETA-A Noise Rating (LAMBDA) LAMBDA-A
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC Sources Chroma 6530, Keysight AC6804B Power Analyzers N4L PPA1530 x2 Sound Analyzer Bruel & Kjaer 2270 G4 Microphone Bruel & Kjaer Type 4955-A Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2 Tachometer UNI-T UT372 x2 Digital Multimeter Keysight U1273AX, Fluke 289, Keithley 2015 - THD UPS CyberPower OLS3000E 3kVA x2 Transformer 3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Chroma 63600-2 x2 63640-80-80 x20 63610-80-20 x2
PAGE 3/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
Page 4
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Asus ROG RSSS04-750G1 (Sample #3)
INFO
This graph depicts the PSU’s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 4/9
info@cybenetics.com
Page 5
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test # 5VSB
0.045A 0.231
1
5.137V 0.345 115.16V
0.090A 0.463
2
5.136V 0.639 115.15V
0.550A 2.820
3
5.127V 3.643 115.16V
1.000A 5.118
4
5.117V 6.581 115.15V
1.500A 7.661
5
5.106V 9.847 115.13V
DC/AC (Watts)
Efficiency PF/AC Volts
66.957%
72.457%
77.409%
77.769%
77.800%
0.062
0.110
0.345
0.424
0.465
Asus ROG RSSS04-750G1 (Sample #3)
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test # 5VSB
0.045A 0.231
1
5.137V 0.380 230.34V
0.090A 0.463
2
5.136V 0.682 230.34V
0.550A 2.820
3
5.127V 3.701 230.34V
1.000A 5.118
4
5.117V 6.625 230.34V
1.500A 7.660
5
5.106V 9.947 230.34V
DC/AC (Watts)
Efficiency PF/AC Volts
0.019
60.789%
0.034
67.889%
0.161
76.196%
0.242
77.253%
0.299
77.008%
6
3.000A 15.214
5.071V 20.039 115.12V
VAMPIRE POWER -230V
75.922%
0.510
6
3.000A 15.221
77.682%
5.074V 19.594 230.34V
0.384
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 5/9
info@cybenetics.com
Page 6
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Asus ROG RSSS04-750G1 (Sample #3)
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
PAGE 6/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
Page 7
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
10-110% LOAD TESTS
Test #
1
2
3
4
5
12V 5V 3.3V 5VSB
4.376A 1.998A 1.978A 0.980A 74.547
12.099V 5.008V 3.334V 5.104V 85.957 40.06°C 230.37V
9.799A 2.999A 2.968A 1.179A 149.455
12.099V 5.004V 3.332V 5.090V 164.554 40.87°C 230.37V
15.618A 3.500A 3.452A 1.379A 224.979
12.100V 5.001V 3.330V 5.078V 244.387 41.26°C 230.37V
21.367A 4.001A 3.965A 1.579A 299.765
12.101V 5.000V 3.329V 5.066V 324.986 48.51°C 230.37V
26.798A 5.004A 4.962A 1.781A 374.694
12.097V 4.998V 3.327V 5.054V 406.992 49.40°C 230.37V
DC/AC (Watts)
Asus ROG RSSS04-750G1 (Sample #3)
Fan
Efficiency
86.726% 0 <6.0
90.824% 0 <6.0
92.058% 0 <6.0
92.239% 422 8.3
92.064% 778 23.2
Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
45.20°C 0.764
46.47°C 0.891
47.31°C 0.932
41.47°C 0.952
42.00°C 0.962
PF/AC Volts
6
7
8
9
10
11
CL1
CL2
32.222A 6.008A 5.956A 1.984A 449.605
91.804% 827 24.9
12.097V 4.995V 3.325V 5.041V 489.742 50.71°C 230.37V
37.677A 7.014A 6.953A 2.188A 524.928
91.463% 838 25.1
12.098V 4.992V 3.322V 5.028V 573.922 51.85°C 230.37V
43.124A 8.021A 7.952A 2.394A 600.255
91.030% 856 25.6
12.101V 4.988V 3.320V 5.014V 659.406 52.42°C 230.36V
48.944A 8.527A 8.438A 2.397A 674.785
90.568% 1087 32.3
12.101V 4.986V 3.318V 5.006V 745.063 54.18°C 230.36V
54.575A 9.034A 8.953A 3.010A 750.012
89.950% 1458 40.1
12.099V 4.982V 3.317V 4.985V 833.813 56.11°C 230.36V
60.812A 9.039A 8.959A 3.014A 825.235
89.326% 1924 46.9
12.095V 4.980V 3.315V 4.977V 923.844 58.33°C 230.36V
0.152A 12.000A 12.001A 0.000A 101.769
85.918% 392 8.1
12.119V 5.001V 3.326V 5.103V 118.449 49.37°C 230.36V
62.018A 1.004A 0.999A 1.000A 763.417
90.420% 1527 40.9
12.094V 4.989V 3.323V 5.042V 844.303 56.40°C 230.36V
42.74°C 0.969
43.33°C 0.973
43.42°C 0.977
44.71°C 0.979
45.96°C 0.981
46.69°C 0.983
42.20°C 0.839
45.68°C 0.981
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 7/9
info@cybenetics.com
Page 8
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
20-80W LOAD TESTS
Test # 12V 5V 3.3V 5VSB
1.206A 0.500A 0.477A 0.195A 19.689
1
12.096V 5.015V 3.339V 5.128V 27.559 230.37V
2.460A 0.999A 0.988A 0.391A 40.060
2
12.096V 5.011V 3.336V 5.121V 49.492 230.39V
3.649A 1.498A 1.467A 0.587A 59.537
3
12.096V 5.010V 3.335V 5.114V 69.918 230.37V
4.907A 1.997A 1.979A 0.783A 79.958
4
12.097V 5.008V 3.334V 5.107V 91.387 230.37V
RIPPLE MEASUREMENTS
DC/AC (Watts)
Asus ROG RSSS04-750G1 (Sample #3)
Efficiency
71.443% 0 <6.0
80.942% 0 <6.0
85.153% 0 <6.0
87.494% 0 <6.0
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
0.471
0.599
0.702
0.780
Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 9.9 mV 5.9 mV 11.1 mV 7.7 mV Pass 20% Load 14.2 mV 6.0 mV 11.1 mV 7.8 mV Pass 30% Load 17.1 mV 6.3 mV 11.3 mV 7.9 mV Pass 40% Load 18.9 mV 6.4 mV 11.8 mV 8.1 mV Pass 50% Load 16.5 mV 7.1 mV 12.2 mV 8.0 mV Pass 60% Load 16.9 mV 7.0 mV 12.9 mV 8.1 mV Pass 70% Load 18.0 mV 7.3 mV 14.2 mV 8.3 mV Pass 80% Load 19.1 mV 7.5 mV 16.7 mV 9.2 mV Pass 90% Load 20.5 mV 7.6 mV 16.0 mV 9.0 mV Pass 100% Load 27.3 mV 8.8 mV 17.1 mV 9.5 mV Pass 110% Load 30.3 mV 9.1 mV 16.4 mV 10.4 mV Pass Crossload 1 14.5 mV 8.7 mV 16.3 mV 9.1 mV Pass Crossload 2 27.2 mV 7.5 mV 12.8 mV 10.1 mV Pass
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 8/9
info@cybenetics.com
Page 9
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms) 19.20 AC Loss to PWR_OK Hold Up Time (ms) 17.05 PWR_OK Inactive to DC Loss Delay (ms) 2.15
Asus ROG RSSS04-750G1 (Sample #3)
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 9/9
info@cybenetics.com