INSTALLER-SPECIFIC INFORMATION (Installation & Set Up) ------30
Installer-Specific Table of Contents -------------------------------31
CONTACTING THE FACTORY ------------------------------------------57
4
Welcome
to the
T
eam
Dear Owner:
ongratulations on your wise decision to make an AquaCal heat pump part of
your home. Since 1981, AquaCal has maintained the worldwide lead in the
C
manufacture of swimming pool & spa heat pumps. Your new heat pump is not
only a great investment, but also the most
cost effective method available for heating pools and spas. For example, your
heat pump is up to 400% more efficient
than gas, and, when compared to electric resistance heat, your heat pump is
nearly 600% more effective. You can rest
assured your new heat pump is of the
highest quality and efficiency, and is designed and built to provide years of
trouble-free operation.
Moreover, should you ever require help in
using or maintaining your heat pump, you
will find AquaCal’s customer and technical
support staff to be the largest, most qualified, and—of utmost importance—the
most easily accessed customer service team in the pool & spa heat pump industry.
“You can rest assured
knowing your new heat
pump is of the highest
quality and efficiency,
and is designed and
built to provide years
of trouble-free
operation.”
5
Important Features of Your
New Heat Pump
ThermoLink® Heat Exchanger
The heart of your heat pump is the patented ThermoLink® heat exchanger. One of the
primary causes of premature heat pump demise is the failure of the heat exchanger.
Ordinary heat exchangers are made from a cupronickel alloy. This cupronickel material is
susceptible to attack from the sanitizers used in pools and spas and from other related
water chemistry conditions. Once the heat exchanger fails, the heat pump is ruined. The
ThermoLink
water chemistry damage.
50% fewer moving parts than standard piston-type compressors. This equates to much
improved reliability and improved efficiency. Scroll compressors are also much quieter in
operation than their piston-type counterparts. And, while all AquuaCal heat pumps are
known for their low operating noise levels, if yours is a SuperQuiet
likely your heat pump will be quieter than any other item on the pool equipment pad.
®
heat exchanger tube is made from titanium, and is virtually impervious to
Scroll Compressor
TM
model, it’s very
Digital Controller
Digitally-based microprocessor controls water temperature to within 1º Fahrenheit of
set point. Controller also permits user to predefine different pool and spa water temperatures, and to prevent tampering by locking out controls via a pass code.
Corrosion-Proof Cabinet
The cabinet, being made from resilient, UV-Protected ABS material, has superior fade
resistance and can never rust or corrode. You can expect the cabinet to retain a likenew appearance with only an occasional wash down and—if so desired—a quick waxing.
Heat & Cool Capability*
Puts you in full control, year round... Warms your pool or spa with the reliability and
efficiency of our other heat pumps, but, with the flip of a switch, can also cool your pool
or spa to refreshing temperatures during hot summer months. For cooler climates,
Heat & Cool heat pumps offer unique advantages over passive defrost models. Please
read more below...
Hot Gas Defrost*
Hot gas defrost heat pumps are uniquely equipped for an active defrost cycle. Active
defrost involves directing hot refrigerant vapor to the heat collector, melting accumulated ice away in a matter of a few minutes... then right back to heating. Standard defrost
heat pumps may remain “off in defrost” for extended periods during very cold weather.
Because of their ability to continue to operate–even during freezing weather–hot gas
defrost models extend the swimming season longer than any standard-defrost heat
pump.
*
These features available in Icebreaker®and SuperQuietTM Models Only.
PLEASE READ FURTHER TO BECOME FAMILIAR WITH ALL THE FEATURES, THE SAFE
OPERATION, AND THE CARE OF YOUR NEW HEAT PUMP.
6
HOW A HEAT PUMP WORKS
THE FOLLOWING EXPLANATION IS PROVIDED TO HELP YOU IN UNDERSTANDING
WHAT TO EXPECT FROM YOUR HEAT PUMP
…
A Heat Pump Does Not Make Heat…
Heat pumps are so extraordinarily efficient because they do not need to produce heat in
order to warm pool or spa water. Rather, heat pumps simply transfer heat from the
outside air into the water.
If one considers Absolute Zero (the point where all heat is absent) occurs at -459º
Fahrenheit, it becomes evident outside air, even at the relative cool temperature of 55º
Fahrenheit, still contains large amounts of heat energy. It is that abundant heat energy a
heat pump captures and places into your pool or spa.
...
IR
H
EAT
EMOVED FROM
R
IR
A
OOL
C
O
A
UT
W
ARMED
O
UT
W
ATER
C
OOL
I
W
N
ATER
ADEN
NTERS
L
E
EAT
IR
H
A
7
SAFETY INFORMATION
Used and maintained properly, your heat pump will provide year-upon-year of safe and
economical service. However, as with any mechanical or electrical device, to get the
most from your heat pump–while insuring personal safety for you and others–certain
operational and maintenance factors must be observed.
Likewise, excepting a few minor owner-capable maintenance items (explained later in
this manual), repair and service of your heat pump must be performed only by experienced service personnel. Should you, the owner, suspect your heat pump is not performing properly, by referring to the section in this manual entitled: "Troubleshooting,"
you will be able to determine if a call for service is required. Your installer can be one
source of service, or AquaCal Customer Support personnel stand ready to assist you
at: (800) 786-7751. For questions concerning installation, modifications, operation,
service and upkeep, please contact your installer or AquaCal Customer Support. Warranties may be voided if the heater has been used, maintained, or repaired improperly.
In addition to voiding the manufacturer’s warranty... unapproved installation methods,
nonstandard modifications, poor or incorrect maintenance, service by unqualified personnel, or improper use of the heater may result in personal injury and/or property
damage. For personal safety, and to avoid damage to equipment, follow all safety
instructions displayed on the heat pump and within this manual.
Safety Signals
Throughout this manual the following two safety signals are placed where particular care
is required. Please note "WARNING" relates to personal safety, while "CAUTION" signals
promote avoiding damage to equipment.
Failure to heed the following may result in perma-
WARNING !
“Warning” signal appears in this manual where special attention is required for personal
safety. (Specific instructions will appear in this box.)
CAUTION !
“Caution” signal appears in this manual where special care is required to avoid
equipment damage. (Specific instructions will appear in this box.)
nent injury or death.
Failure to heed the following may result in equipment
damage.
8
Notice: Heater NOT Repairable by Owner
Failure to heed the following may result in permanent
WARNING !
Heat pumps contain no owner-repairable components. Repairs must not be attempted
by untrained and/or unqualified individuals. If service is deemed necessary, contact
installing dealer or AquaCal Customer Support at (800) 786-7751.
injury or death.
Refrigerant Circuit Service Only by
Qualified, EPA Certified Technician
Failure to heed the following may result in permanent
WARNING !
Heater contains refrigerant under pressure. Repairs to the refrigerant circuit must not be
attempted by untrained and/or unqualified individuals. Service must be performed only by
qualified HVAC technicians. Recover refrigerant before opening system.
injury or death.
Water Temperature Safety
Failure to heed the following may result in permanent
WARNING !
Prolonged immersion in water warmer than normal body temperature may cause a condition known as HYPERTHERMIA. The symptoms of hyperthermia include: unawareness of
impending hazard, failure to perceive heat, failure to recognize the need to exit the spa,
and unconsciousness. The use of alcohol, drugs, or medication can greatly increase the
risk of fatal hyperthermia. In addition, persons having an adverse medical history, or pregnant women, should consult a physician before using a hot tub or spa. Children and the
extreme elderly should be supervised by a responsible adult.
injury or death.
Water Chemistry Safety
Failure to heed the following may result in permanent
WARNING !
Improper water chemistry can present a serious health hazard. To avoid possible hazards,
maintain Pool/Spa water per standards detailed later in this manual.
CAUTION !
injury or death.
Failure to heed the following can result in damage to
equipment.
While your heat pump’s titanium-based heat exchanger provides nearly impervious
protection against poor water chemistry, improper water chemistry may cause expensive
damage to pump, filter, pool shell, etc. To avoid equipment damage, maintain Pool/Spa
water per standards detailed later in this manual.
9
Getting Started
HEATING- QUICK START & STOP
This brief information is provided as an aide to installers, service personnel, and owners. The intent of
this section is to provide rapid access to very basic operational information. Individuals who will be
routinely using, installing, maintaining, and servicing this heat pump, are strongly encouraged to read
this entire manual. Herein, the terms: Heat Pump, Heater, and Unit are used synonymously. These
instructions are intended for local control of a heat pump, independent of an external controller. Owners: if your installation includes an external controller, contact your installing dealer,
or the external controller manufacturer, for external controller operating instructions.
These instructions are for quick-starting in the HEATING mode... Owners of Heat-Cool units, in
order to utilize all features of their heater, will certainly want to also refer to:
ming, beginning on page-14 of this manual.
1. Verify Electrical Power is Present at Heater:
A. Ensure that the unit has electrical power connected; the heater controller display should be
illuminated.
B. If the display is blank, be certain the electrical breaker, and heater disconnect, are switched to
“ON.”
C. For now, leave the water circulation pump OFF.
Owner Level Program-
2. Set the Heater Controls (Refer to Control Panel Layout, Pg-12):
OWNER- If heater is connected to a Call-Flex controller, also see “Selecting Call-Flex Pump
Options,” located on page-17 of this manual.
INSTALLER- Is heater connected to an external controller? If so, see external controller
information located on pages 41 and 44 of this manual.
A. The user/owner settings can be made without water flowing. Once the heater has electrical
power connected, with water not flowing, the display should read FLO.
B. Press the MODE button until the HEAT (HEA) indication displays. This action will enable the
remaining programming keys.
C. Using the POOL / SPA selector key, select the POOL mode. An illuminated POOL indicator
light, located on the left side of the display, will confirm the POOL control has been selected.
If heating only a spa, using the DOWN arrow key, lower the POOL temperature until OFF is
displayed; then proceed to Step-“E.”
D. Use the UP / DOWN arrow keys to set the desired water temperature for the POOL water.
E. If the heat pump will be used to heat a spa, use the POOL/SPA selector key to select SPA,
then use the UP / DOWN arrow keys to set the desired water temperature for the SPA. An
illuminated SPA indicator light, located on the left side of the display, will confirm the SPA
control has been selected. If heating only a POOL, using the DOWN arrow key, lower the
SPA temperature until OFF is displayed.
F. The heat pump controls are now set to maintain the desired water temperature for the POOL
and/or SPA.
10
(Quick-Start & Stop Continued Next Page)
HEATING-QUICK START & STOP (continued):
3. To Begin Heating:
A. Verify MODE is set to: HEAT (HEA); then, depending on which body of water is to be heated,
use the POOL / SPA selector key to select POOL or SPA.
B. Position water valves to flow water from the pool or spa, through the heater, and back to the
pool or spa.
C. Start the water pump; the fan will start, and after 4-minute time delay the unit will begin
heating. The selected body of water will be brought to temperature and maintained per the
setting determined previously in: “Set the Heater Controls.”
D. In operation, whenever the actual (displayed) water temperature falls below the desired set
point, after an initial time delay of 4-minutes, the unit will begin heating.
NOTE: THE HEATER CONTROLLER INCORPORATES AN ANTI-SHORT CYCLE TIME DELAY. SHOULD OPERATION BE
INTERRUPTED
4. Program Filter Pump Run Time:
Most pool/spa systems utilize a timer or multifunction controller to manage filter pump run times.
If your system incorporates such a device, follow the instructions below:
A. It will be necessary to allow the filter pump to run continuously until the water has reached the
desired temperature. If a timer controls the pool filter pump, it will be necessary to override
the timer to allow 24-hr. operation.
B. Once the desired temperature has been obtained (1-4 days), reset the pump control device.
Colder months require longer running times–generally eight to twelve hours/day.
C. A heat pump can only operate when the filter pump is running. Therefore, it may be
necessary–during cooler weather–to extend the water pump’s hours of daily operation.
The increased run time is necessary in order to keep up with increased, weather-related
heat losses.
, COMPRESSOR RESTART WILL BE DELAYED BY APPROXIMATELY 4-MINUTES.
5. Continuous Usage and Water Around Heater:
Condensation... After the heat pump has been operating for some time, water may be observed
surrounding the heater. The moisture seen is condensation produced as a normal by-product of
transferring heat from the air into the pool or spa water. Quantities of 6-8 gallons of water produced
per hour are common if the air humidity is high. Conversely, a low humidity condition may result in
no condensation being produced. (If water around unit seems excessive, to troubleshoot, see
page-26, “Water Coming from the Heat Pump.”)
6. To Stop the Heat Pump:
A. Select: OFF via the MODE selector. This method of shut down preserves the controller
settings;
B. An interruption of water flow–such as when a pump timer is in control–will also halt heat
pump operation.
(End...Quick-Start & Stop)
11
HEATER CONTROLS
Control Panel Layout
(APPEARANCE VARIES BY MODEL)
Control Buttons, Indicator Lights, & Display
(AS INDICATED BY CIRCLED NUMBERS)
1) POOL / SPA SELECTOR – Selects either pool or spa thermostat.
2) COOLING INDICATOR LIGHT – Indicates unit is cooling. (Note: this light
nonfunctional with heat-only models.)
o
3) UP ARROW – Increases temperature setting. (Maximum setting is 104
4) DOWN ARROW – Decreases temperature setting. (Minimum setting is 45
5) HEATING INDICATOR LIGHT – Indicates unit is heating.
6) MODE SELECTOR – Used to select between the Heating, Cooling, Auto-
Changeover, and Off for Heat & Cool models. Used to select between Heating
and Off for heat-only models.
8) POOL INDICATOR LIGHT – Indicates heater is referencing pool thermostat.
9) LED DISPLAY – Displays water temperature when no keys are being pressed.
Displays desired temperature when UP ARROW or DOWN ARROW is pressed.
Also displays operational, programming, and fault codes as applicable.
10) DESIRED TEMPERATURE LIGHT – Indicates temperature set point is being
displayed. Indicates temperature set point is being changed due to the UP
ARROW or DOWN ARROW being pressed.
F)
o
F)
12
11) WATER TEMPERATURE LIGHT – Indicates current water temperature is being
displayed.
HEATER CONTROLS...continued
Operational & Programming Codes
HE FOLLOWING CODES WILL BE DISPLAYED AS PART
T
OF THE NORMAL OPERATION OF THE HEATER
FLO..... No Water Flow Detected. This code appears whenever the circulating pump is off, or when
the heater is not receiving correct water flow.
:
OFF..... System is Off. This code appears whenever heater has been turned off via the mode
selector button, or when the temperature set point has been lowered below 45
CFI...... Celsius/Fahrenheit Selection. This is a programming entry point to select in which format
the water temperature will be displayed.
ULC..... User Lock Code. This is a programming entry point; when activated, steps to the next
menu level: ELC.
ELC..... Enter Lock Code. This a programming entry point; permits end user to select a secret
code, thereby limiting access to the owner settings.
CFO..... Call Flex Options. This is a programming entry point; when used in conjunction with an
AquaCal Call/Flex add on kit, permits the use of CALL or FLEX options.
FS....... Heater in Defrost Mode (Applicable to Heat-Only Units, only). This code appears as a
normal display during periods of lower air temperatures. Sequence follows:
Heat-Only Defrost Sequence: Fan continues to run and compressor is off. Compressor
will restart when air coil temperature rises to approximately 38°F.
o
F.
LOC..... This is a Service Entry Point (not intended for use by the owner). The[LOC] code permits
service personal to enter a factory code for access to adjustable calibration and sitedependant setup parameters. Service adjustments are available to authorized installation
and service personnel, only.
CAUTION !
Heat pumps contain no owner-serviceable components. Owner-initiated adjustments, beyond
the controller “LOC” code, must not be attempted. If adjustments are deemed necessary, the
owner should contact installing dealer or AquaCal Customer Support at (800) 786-7751.
Failure to heed the following may result in equipment damage and voiding of manufacturer’s warranty.
13
HEATER CONTROLS...continued
Start Up & Setting Operating Controls
Owner-Level Programming Instructions (Complete)
Covered within this section are features and settings typically accessed first by the installer, and then
remaining accessible by the end user (the owner). These features reside at the Level-1 access point
within the microprocessor. Note: if preferred, all programming may be performed with
waiting to start the water pump as the last step in the set up and run process.
1. Applying Power to The Controller:
A. When power is first applied, the controller performs a lamp test and the display will read
[888]. Following [888] the software version will display briefly.
B. The control will then display the actual water temperature, provided the circulating pump is
operating, and adequate water is flowing through the heater.
C. If the pool-circulating pump is off, the control will display: [FLO]. This code message
indicates no (or insufficient) water is being circulated through the heat pump.
2. MODE Controls Explained, and Starting the Heat Pump:
A. Once electrical power is supplied to the heat pump, sufficient water is circulating, and the
heater controller has successfully completed its self-test, the heater is ready to operate.
out water flow,
B. The heat pump is shipped with the controller [MODE] function set to “OFF”. There are two
ways to switch the heat pump OFF:
button is “OFF”.
below the minimum temperature setting (45oF); this action will cause the display to read
“OFF”. To switch the unit ON, first use the mode button to select the HEAT mode—for Heat
Only models—or, if the heat pump is a Heat and Cool model, use the mode button to select
one of the following modes: HEAT, COOL, or ACH (Auto-Changer Over). In the [OFF] mode,
the actual water temperature will be displayed as long as the circulating pump is operational
and correct water flow is present. In the event water is not circulating through the heat pump
(or flow is insufficient), the controller will display the [FLO] (No Water Flow) code message.
C. Using the UP ARROW key, increase the desired temperature until it exceeds the value of the
actual temperature displayed. (Note: See # “8,” later in this section, if “000” is displayed upon
pressing either the up or down arrow keys.) Once the desired temperature has been
entered, the display will read the actual temperature and the heat pump will start to operate.
Both the compressor and the fan must be operating before the “Heating” LED will illuminate.
(Note: When MODE function is OFF, the current water temperature will be displayed; no
functions, values, or programming will be available for adjustment.)
3. Turning The Heat Pump Off:
A.
Method 1: using the [MODE] key, press the key until the display reads “OFF” The
heater will shut off and remain off until the [MODE] key is used the select an operational
mode. This is the preferred method for shutting off the heat pump.
Second Method- The thermostat set point can be lowered to a position
First Method- One of the functions of the [MODE]
14
B.
Method 2: using the DOWN key, press the key until the desired water temperature reaches
45oF (minimum setting); then, press the DOWN key one more time, causing the display to
read “OFF”. This method is typically used in conjunction with 2-wire external controllers;
these controllers are equipped with their own thermostats.
A. Press the [POOL/SPA] key to toggle between the pool and the spa temperature set points.
B. The pool/spa LED indicator lights, located to the left of the temperature display, will confirm
the selected set point.
5. Changing The Pool Temperature Set Point:
A. Using the [POOL/SPA] key, select the POOL temperature set point. The pool set point
indicator light will confirm the selection.
o
B. The pool temperature set point is adjustable from a minimum of 45
104oF. Pressing the [UP ARROW] key will raise the set point 1-degree for every push of the
button. Pressing the [DOWN ARROW] key will lower the set point 1-degree for every push
of the button.
6. Changing The Spa Temperature Set Point:
F to a maximum of
A. Using the [POOL/SPA] key, select the SPA temperature set point. The spa set point indicator
light will confirm the selection.
o
B. The spa temperature set point is adjustable from a minimum of 45
F to a maximum of
104oF. Pressing the [UP ARROW] key will raise the set point 1-degree for every push of the
button. Pressing the [DOWN ARROW] key will lower the set point 1-degree for every push
of the button.
7. Selecting Between
o
F and oC:
A. Simultaneously press and hold both the [UP ARROW] and [DOWN ARROW] keys until
[CF1] (Celsius / Fahrenheit) code appears.
B. With the [CF1] code displayed, pressing the [UP ARROW] or [DOWN ARROW] keys will
change the selection code to either “0” or “1”. Select “1” for Fahrenheit temperature display,
or “0” for Celsius temperature display. Once the desired temperature display mode has
been selected,
not pressing any buttons for 15-seconds will allow the controller to save the
selection and return to the normal operating mode. Pressing the {POOL/SPA] key will also
save the selection and step to the next menu parameter: [ULC] (User Lock Code).
8. User Lock Code Option [ULC]:
This Option Explained:
Heat pumps are shipped from the factory with the [ULC] option disabled. Enabling the [ULC]
function permits the heat pump owner to restrict access to the unit’s controls. With the [ULC]
function enabled, unless the correct ULC code number is entered, changes to Level-1
programming are not possible. (I.e.: Altering temperature set points, Pool/Spa selection, C/F
display changes, etc., will not be possible). The [ULC] option can be thought of as an electronic
lockable cover for the controls.
1) Press either the UP or DOWN ARROW keys; if “LOC” is momentarily displayed followed
by “0”, the ULC feature is enabled. If “0” displays proceed to “6)” of this section;
otherwise, see number “2,” below.
2) Simultaneously press and hold both the [UP ARROW] and [DOWN ARROW] keys until
[CF1] (Celsius / Fahrenheit) code appears.
3) Press the [POOL/SPA] key once to display [ULC].
4) With [ULC] displayed, pressing either the Up or Down Arrow key will display either “1” or
“0”. Selecting “0” will allow the keypad to remain unlocked. Selecting “1” will enable the
User Lock Code option. Then, to enter a lock code number, press the [POOL/SPA] key
once to display [ELC] (Enter Lock Code).
5) With [ELC] displayed, use the Up or Down arrow keys to select a lock code. The code
can be any number from “00” to “99”. The factory set lock code is “0”. Not pressing any
buttons for 15-seconds will allow the controller to save the selection and return to the
normal operating mode. Pressing the {POOL/SPA] key will also save the selection, and
will step the controller to the next menu parameter: [CFO] (Call Flex Options).
6) Once the ULC option has been enabled, pressing any key will momentarily display
“LOC” followed by “0” (prompting the entry of the correct lock code number). To gain
access to the controller:
a. Using the [UP ARROW] key, scroll to the correct lock code number, then;
b. Press the [POOL/SPA] key… Current water temperature will be displayed… Control
setting can now be viewed or changed as desired.
c. After a period of approximately four (4) minutes, during which time no buttons have
been pressed, the controller will automatically return to the locked mode. Provided
ULC selection is set to “1,” the controller will always fail-safe in the locked mode.
d. Without knowledge of the correct lock code, and with the ULC enabled, control
adjustments will
place. The lock code may be changed any number of times by following the
instructions detailed in this section.
B. De-Activating the User Lock Code [ULC] function:
1) Following the instructions detailed previously at: “8, 6)”, press any key and enter the
user lock code number; then press the [POOL/SPA] key.
2) Immediately following the entry of the user lock code, simultaneously press and hold the
[UP ARROW] and [DOWN ARROW] keys until the code [CF1] appears on the display.
3) Then, use the [POOL/SPA] key to scroll to the [ULC] message; press the [DOWN
ARROW] key to change the display to “0”. This will disable the User lock function.
not be possible. Be certain to record your lock code in a safe
C. User Lock Code is Activated, but Pass Number is Not Known (“Back Door Entry”):
Note: Should the ULC option be enabled, and a lock code number other than the factory
default (0) be installed but is unknown, the following procedure may be followed to regain
controller programming access:
1) Simultaneously press and hold the [POOL/SPA] and [UP ARROW] keys until the display
shows “888”. This operation will reset the controller to the factory default settings.
2) When reset to the factory default settings the user lock code [ULC] is deactivated and
the user lock code number [ELC] is reset to “0.”
3) In addition, all other settings are returned to the factory defaults. If an external
controller is in use, contact AquaCal Technical Support Group (800-786-7751); ask for
assistance with re-configuring the controller for use with an external controller.
9. Selecting Call-Flex Pump Options [CFO]:
General Information:
The Call-Flex option automatically adjusts the run time of the water circulator pump, and heater,
based upon changing weather conditions. Without Call-Flex, as weather conditions grow
progressively cooler during winter months, or when unusually cold weather occurs, the run
duration of the circulator pump may require manual adjustments to permit the heater to maintain
or reattain desired water temperature (the water pump must be running in order for the heater to
operate). Likewise, without Call-Flex, one must remember to reset the pump run controls
following the cold weather event. The Call-Flex option greatly reduces the need for seasonal,
manually-made, pump run time adjustments. Call-Flex is a dealer-installed option that doesnot come with every heater; if unsure, check with the installing dealer to determine if a call-flex
kit was part of the original installation.
to have Call-Flex added, your dealer can do so...contact the installing dealer.
If the installation is equipped with the Call-Flex option, the following steps are used to control the
Call-Flex features:
A. Simultaneously press and hold the [UP ARROW] and [DOWN ARROW] keys until the
display shows “CF1”. Press the [POOL/SPA] key three times to scroll the display to [CFO].
B. With the [CFO] (Call-Flex Options) code displayed, use the Up or Down keys to select “0” to
disable the Call Flex Options, “1” to enable the Call Option, or “2” to enable the Flex Option.
Not pressing any buttons for 15-seconds will allow the controller to save the selection and
return to the normal operating mode. Pressing the {POOL/SPA] key will also save the
selection, and will step the controller to the next menu parameter: [LOC] (Service Lock
Code).
If Call-Flex was not part of the installation, and you would like
C. For further information, please refer to Call-Flex installation instructions, shipped with the
Call-Flex kit. For additional copies of these instructions, contact the AquaCal Customer
Support (800-786-7751).
(End... Owner-Level Programming Instructions)
17
MAINTENANCE
&
OPERATIONAL RECOMMENDATIONS
The information in this section is written primarily for the Home Owner, but may also apply to servicing
dealers or HVAC service centers. This section contains information concerning planned maintenance,
proper water flow, maintaining proper clearances, as well as other vital information. Please read this
section now, and before calling AquaCal Customer Support (800-786-7751).
General Maintenance
Heat pumps should be inspected and maintained on an annual basis by a qualified swimming pool
heat pump specialist. Additionally, if the heat pump is located near the beach or coastal area, where
salt spray and sand can become detrimental factors, more frequent service may be necessary. For
service plan information, please see:
contact AquaCal Customer Support at: 800-786-7751.
Planned Maintenance Program, later in this section, and then
While annual maintenance is recommended to maintain your warranty, if you choose
in the Planned Maintenance Program, rinsing the air coil regularly, and keeping the base of the unit
clear of leaves and debris is a necessity.
Should you as the owner desire to perform the coil rinsing and other cosmetic care of the heat pump,
please contact AquaCal Customer Support: 1-800-786-7751; request the document titled: “
Care for Air-Source Heat Pumps: Approved Method for Home Owners.”
not to participate
Appearance
Safety During Cleaning Operations
Failure to heed the following may result in permanent
WARNING !
POSSIBLE ELECTRIC SHOCK HAZARD . . . Should you decide to wash the heat pump
via water hose, disconnect all power to the pool equipment pad- including, but not limited
to: The heat pump, water pump, and any and all other electrical equipment. Do NOT spray
water directly into electrical components. Do NOT restore electrical power until such time
as all water has dried completely.
injury or death.
18
Failure to heed the following may result in damage to
CAUTION !
Do not use a pressure cleaner to wash heat pump . . . . Damage to evaporator fins, as
well as other components, will result.
equipment.
MAINTENANCE
& OPERATION (continued)
Maintain Proper Water Flow
•It is important to operate and maintain the filter according to the manufacturer's specifications.
As a filter gets dirty, the water flow to the heat pump is reduced. The higher the pressure on the
filter gauge, the lower the flow rate.
•Similar to a dirty filter, large amounts of debris in the pump and skimmer baskets can reduce
water flow. Keep baskets free of debris.
•Check for improper valve settings. A partially closed valve after the filter, or a full-open bypass
around the heater, will cause insufficient water flow through heater.
•If the conditions listed above remain unresolved, the water flow through the heater may be
reduced to a point where internal safety devices (i.e.: “HP” or “HP5”) shut the heater off.
•Before calling for service, always check the filter, the pump basket, and water valve positions. If
the problem persists, please call AquaCal Customer Support at: (800)786-7751.
Control Water Chemistry
•IMPORTANT! Your heat pump is engineered for exceptional durability and reliability. And, this
unit’s heat exchanger—being equipped with titanium tubing—will be nearly impervious to water
chemistry damage. However, other components of the heater, and the remainder of the pool/spa
equipment in general, may be susceptible to damage from prolonged exposure to unbalanced
water chemistry. Likewise, bathers may be exposed to health risks if water chemistry is not
properly maintained.
•For the longevity of the entire pool/spa installation, and for the safety of bathers, it is strongly
recommended the water chemistry be checked regularly and maintained within proper norms.
Please see the table, below, for a complete listing of recommended water chemistry levels.
* STANDARDS FOR COMMERCIAL APPLICATIONS MAY VARY LOCAL-TO-LOCAL...
ALWAYS MAINTAIN WITHIN LIMITS ESTABLISHED BY AUTHORITY HAVING JURISDICTION.
CAUTION- Pool/Spa Refinishing Operations
During pool refinishing or acid cleaning, the water flow through the heater must be shut off. Water flow
to the heater must remain off until water chemistry is once again in balance and the water is clear in
appearance. Failure to follow these instructions may void heater warranty.
1.0 – 3.0 ppm in pools, 1.5 – 3.0 ppm in spas
2.0 – 4.0 ppm in pools, 3.0 – 5.0 ppm in spas
7.4 – 7.6 ppm in pools, 7.2 – 7.8 ppm in spas
80 – 140 ppm in pools, 80 – 120 ppm in spas
200 – 400 ppm in pools and spas
1,000 – 2,000 ppm in pools,
1,500 ppm above start-up TDS in spas
19
MAINTENANCE
(
)
& OPERATION (continued)
Control Irrigation and Storm Run Off
•Control Irrigation: In regions were wells are used for irrigation, water quality is sometimes poor,
and water spray can damage heater components. Regardless of water quality, it is important
that irrigation be directed away from the heat pump.
•Prevent rain water runoff from pouring directly into the heater. The heater is designed to
withstand normal rainfall, but solid streams of water from roof drip-lines may eventually damage
heat pump components.
•If the heat pump resides beneath a roof edge, to promote heat pump longevity, a rain leader
(gutter), or rain shield, will be necessary.
Maintain Proper Clearances Around Heater
•For maximum efficiency, proper air flow clearances around heater must be maintained.
•It is important to keep the area immediately adjacent to the heat pump clear of items such as
shrubs and bushes, lawn furniture, chemicals containers, etc. These items can prevent air from
circulating fully through the heater, and will result in inefficient operation or damage to the heat
pump.
•In addition, do not place objects on top of the heat pump; doing so will block the air from exiting
the heater, and will result in damage to the compressor and fan motor.
•Proper clearances are also necessary in order to access the working parts of your heater. A
heater that is easy to "get to," will be a heater that is easy to maintain; service and maintenance
personnel will thank you for keeping the area around your heater unobstructed.
•Please see diagrams, below, for specific clearance requirements.
AINRUN-OFF
R
UST BE DIRECTED
M
WAY FROM
A
EATER
H
.
30” M
C
LEARANCE
VERHANG WITH
O
UTTER
G
INIMUM
, F
RONT
5FT. M
INIMUM CLEARANCE
VERHEAD
O
SQ MODELS, 12-INCHES
ALL OTHER, 6-INCHES
6”M
INIMUMCLEARANCE
(REAR)
SQ MODELS, 12-INCHES; ALL OTHER, 6-INCHES
12-
NCHES
,
,
I
(
SIDE
)
NCHES
6-I
(REAR)
EAR
R
30-I
NCHES
(
FRONT
12-
NCHES
I
SIDE
(
)
)
SIDE VIEW (NO SCALE)
FRONT-REAR-OVERHEAD
TOP VIEW (NO SCALE)
FRONT-SIDES-REAR
20
MAINTENANCE
& OPERATION (continued)
Heating Tips
Heating in Cooler Weather...
Late night and early morning, generally being the coolest times of the day, are least efficient for heating. For most efficient heating operation, heat pumps should be timed to operate during the warmest,
daylight portions of the day. Conversely, if cooling a pool, it is best to run the equipment at night. Please
set water pump and heat pump controls accordingly.
Pool/Spa Blankets...
A “solar” blanket will significantly reduce your heating bills. Check with the installing dealer to see if
your heat pump was sized to be used in conjunction with a blanket. Blanketed pools will typically lose
only 3 - 4° of heat per night versus 8 - 10° overnight with an un-blanketed pool. Reductions of 40-60%
on heating bills can be achieved by using blankets. (Idea...Contact AquaCal Customer Support
(800-786-7751) to learn about Liquid Blanket innovations.)
Failure to heed the following may result in permanent
WARNING !
injury or death.
Improperly used, Pool-Spa blankets can become a drowning risk to people and pets.
Blankets are not safety covers. They are not designed to support the weight of a person
or pet. Never enter a pool until the blanket is completely removed (under no circumstances
should anyone swim under the blanket). Follow all safety recommendations of the blanket
manufacturer.
Pool and Spa Combination Heating...
Everything stated for heating a pool applies for heating a spa—only the volume of water being heated
is different. Your heat pump comes equipped with two thermostats. One thermostat is for the pool and
the other is for the spa. Simply position the pool and spa isolation valves as directed by your installer;
select the appropriate thermostat (pool or spa), whichever you are heating, and with electrical power
and water flow supplied to the heater, the water will be maintained at set point.
Your system can be automated with the addition of an optional
Using this option will save you from having to change the thermostat selector switch each time you
change from pool-to-spa and back again. Or, add a Universal Heater Controller (P.N. 0097TS) and
gain not only automatic thermostat switching, but also automated spa/pool water valve operation. For
details, contact the installer, the distributing dealer, or AquaCal Customer Support (800-786-7751).
External Flow Switch Kit (P.N. 0040S).
Spa Heating & Spa Setback Option...
Air blowing into your spa, while it is being brought to temperature, will very often neutralize or partially
counteract the heat being put into the spa by the heater; this added heat loss equates to increased
time to bring your spa to desired temperature. When heating a spa, be sure to turn off the air blower.
Air induced through the spa jets should also be eliminated, during warm-up, whenever possible.
If your heater is being used to only heat a spa, the
simply set the pool control at a point 10-15º F below desired spa heat temperature and select the pool
thermostat. This method allows the spa–when not in use–to be held at a heated temperature, but
somewhat lower than normal spa-use temperature. One would want to blanket the spa if using this
setback method. Using spa setback will result in reduced warm up periods over full, cold starts.
POOL thermostat can be used as a setback control:
21
MAINTENANCE
& OPERATION (continued)
Calculating Initial Heating Time
The time it takes to initially warm your pool or spa depends on several factors.
First, determine how many gallons of water are to be heated. Knowing this, you can then compute the
equivalent pounds of water involved, and the BTU's necessary to heat the volume of water to the
desired temperature.
Next, find the approximate BTU output of your heat pump at the current ambient air temperature; see
product literature at: www.aquacal.com, or contact AquaCal Customer Support (800-786-7751).
Finally, decide upon the temperature at which you plan to maintain your pool or spa.
The following work sheet can be used to calculate approximately how long it will take your heater to
bring your pool or spa up to temperature. Keep in mind heating times will vary somewhat due to
weather conditions during the period that the heater is in use; use of a pool blanket can dramatically
improve heat up and heat maintenance performance.
Pool Volume (Length X Width X Average Depth) = _________ Pool Cubic Feet
X Gallons per cubic ft.(7.5) = _________ Pool Gallonage
X Pounds per Gallon (8.3) = _________ Pounds of Water
How many degrees do you want to raise the temperature of the pool?
# of Degrees _________ X Pounds of Water (per above) = __________ BTU’s Required
BTU’s Required (per above) ________
Optional Cold Weather Adjustment Factor:
Hrs. of Operation (per above) ______ X 1.25 (60º F outside air (O.A.) Temperature Factor) =
______Hrs. of Operation at 60º F O.A.
÷ BTU Output of Heater = ______ Hrs. of Operation
At Start Up: Continuous Circulator Pump Operation Required
When starting a heat pump for the first time, it must be permitted to operate, continuously, until the
desired water temperature is attained. This may take several hours, to several days, depending upon
the size of the pool or spa and weather conditions.
If a time clock or similar device controls the operating times of the water circulating pump, temporarily
override the water pump controller, allowing for 24-hour, continuous water pump operation.
Once the body of water has reached the desired temperature, the water pump controller can be reset.
22
MAINTENANCE
& OPERATION (continued)
Seasonal Use & Shut Down
During the Swim Season:
•During the swim season, even if the pool or spa is not in use, allow water to flow through the
heater. Doing so eliminates the need to reposition valves when you do wish to heat the pool or
spa.
•During periods when heating or cooling is not desired, leave heater controls in the OFF position.
Important !!!
Information Critical to the
Survival of Your Heater
Follows...
Freeze Protection & Extended Shut Down:
In areas where freezing conditions are a rare occurrence, allow the filtration
system to run continuously throughout the freeze period. Typically, during light
freeze conditions, circulating (moving) water will not freeze.
In areas where freezing conditions are prevalent and sustained, the heat pump
ized; please refer to winterizing instructions, below, and on the following pages.
Winterizing for Hard Freeze Conditions:
CAUTION !
Failure to properly winterize heat pump may result in serious equipment damage. Freeze
damage is not covered under the heat pump warranty.
CAUTION !
While the plumbing connections are in the winterized condition (not fully tightened), it is
imperative pool/spa water
loose plumbing connections may result in damage to circulating pump, pool/spa structure,
and/or other equipment.
not be circulated through the heat pump. Loss of water through
Failure to heed the following can result in damage to
equipment and/or property.
Failure to heed the following can result in damage to
equipment and/or property.
MUST be winter-
(Winterizing continued on page following)
23
MAINTENANCE
& OPERATION (continued)
Winterizing Procedure:
1. Disconnect all electrical power to the heater; turn OFF circulating pump.
2. At the two (2) connection unions, disconnect the plumbing to the heater (removal is counterclockwise).
3. Locate the hand drain plug at lower, front corner of heater. See figure below. (position may vary
between models). Remove plug.
4. Permit all of the water to drain out of the condenser and then replace the plug; thread the plug in
clockwise until just snug, then apply an additional 1/8 turn.
5. To prevent insects and vermin from entering the plumbing during the winterized period, partially
reconnect the two (2) plumbing connection unions: couple each union one or two threads; this
will permit condensation to drain, but will prevent most insects and animals from entering the
plumbing circuit.
Next Season: To ready the heat pump for use, simply retighten plumbing connection unions.
6.
Hand-tight is generally sufficient.
LOCATION OF EXTERNAL DRAIN PLUG
CAUTION !
-EXACT LOCATION
WILL VARY BY MODEL-
Failure to heed the following can result in damage to
equipment and/or property.
24
While the plumbing connections are in the winterized condition (not fully tightened), it is
imperative pool/spa water not be circulated through the heat pump. Loss of water through
loose plumbing connections may result in damage to circulating pump, pool-spa structure,
and/or other equipment.
MAINTENANCE
& OPERATION (continued)
Planned Maintenance Program
Just as you would have yearly service performed on your air-conditioning system, regular inspection
and maintenance of your AquaCal heat pump will insure highest operating efficiencies. A regularly
maintained heater will protect your investment, and will potentially extend the useful life of your heat
pump far beyond the warranty period. Our expertly trained factory service technicians offer comprehensive maintenance procedures designed to insure your heat pump–over the coming years–will continue to operate efficiently and reliably.*
The 20-Point Planned Maintenance Service Includes the Following:
>Check Water Flow
>Clean Evaporator Coil
>Check Relay Contacts
>Check Capacitor Values
>Check Refrigerant Levels
>Clean Heat Pump Cabinet
>Check Fan Blade Clearances
>Check Flow/Pressure Switch
>Check Electrical Connections
>Check Proper Voltage To Unit
>Oil Fan Motor (As Applicable)
>Check Fan Motor Amperage Draw
>Check Pool & Spa Water Chemistry
>Check and Clean Condensate Drains
>Check Compressor Amperage Draw
>Check Water Pump Amperage Draw
>Acid Wash Source Coil (As Applicable)
>Check Air Temperature Change Through Evaporator
>Check Operating Controls and Temperature Sensors
>Check Water Temperature Change Through Condenser
We recommend Preventive Maintenance be performed starting one (1) year after the installation of the
heater.
* FACTORY PM SERVICE NOT AVAILABLE IN ALL REGIONS; PLEASE CONTACT AQUACAL CUSTOMER SUPPORT FOR ADDITIONAL
INFORMATION
(800) 786-7751.
25
TROUBLESHOOTING
Heat Pump Fails to Operate...
Is the display illuminated?
If not, ensure the main breaker (located at the power supply panel) and the disconnect switch
(located near the heat pump) are both turned ON.
Is the code “FLO” displayed?
If so, check to be sure that the circulating pump is operating and the filter is clean. There may also
be a valve positioned incorrectly allowing water to bypass the heat pump. Be sure water is flowing
through the heater.
Is the Pool or Spa thermostat selected for the correct body of water to be heated, and
have you tried selecting a higher temperature setting?
If not, the actual water temperature may be above that of the selected thermostat. Raise the
desired water temperature above the actual water temperature; the fan should start, and after
approximately four (4) minutes, the “Heating” light should illuminate. If the heat pump still fails to
start, and the unit is not in defrost (heat-only unit defrost display code is: “FS”), contact AquaCal
Customer Support: 800-786-7751.
Also see page 51...
“Error Codes”
Heat Pump Running... but is it Heating?
Is the air blowing out of the top of the unit noticeably cooler than the surrounding air?
(With heating indicator light illuminated, a 9°F to 12°F difference is typical.) If not, contact AquaCal for service at: 800-786-7751. But first, be sure all air coil surfaces are free from obstructions–
low roof overhangs, landscaping, walls, fences, etc., can restrict air flow. The heat pump needs
good airflow to operate at peak efficiency.
How many hours/day does the circulating pump operate?
Cooler weather conditions, or heating to a higher than normal temperature, may necessitate
running the heat pump for a longer period of time. Was the heater sized considering the use
of a pool blanket (check with installing dealer)? A blanket can be useful in permitting shorter
run times, in turn leading to substantial energy cost savings.
What is the outside air temperature?
The heat pump may be in the defrost mode if air temperatures are below 50°F. With Heat-Only
models, if the heater is in defrost, the code: ”FS” will be displayed. If air temperatures are not cold,
but the heater remains in defrost, contact AquaCal Customer Support at: 800-786-7751.
Water Coming from the Heat Pump...
Is it a leak or just condensation from normal operation? Here's how to find out.
Test the water draining out the heater base for the presence of the sanitizer being used in the pool
or spa. Using a water test kit, or a test strip, check a sample of the water for chlorine or bromine.
If the sample tests positive for sanitizer, call AquaCal for service at: 800-786-7751. If the test is
negative, the water is probably harmless condensate.
Or, as an alternate method, shut the heat pump off, leaving the circulation pump running. Within a
few hours, there should be a marked reduction in the amount of water seen around the bottom of
the heat pump. If the water appears to be drying up, the water is probably harmless condensate,
indicative of normal operation.
NOTE: The water test method will
produce the sanitizing agent.
CAUTION! If after testing, a water leak is suspected, immediately shut OFF the water pump and
contact AquaCal Customer Support: 800-786-7751.
26
not be effective if an ionizer or ozone generator is being used to
TROUBLESHOOTING FLOWCHART
Display is illuminated. If
Displayisilluminated.If
"FLO" is dis play ed,
"FLO" isdisplayed,
check to be s ure the
check tobe surethe
circulating pump is
operating and the f ilter
circulating pumpis
is clean. There m ay
operating and the filter
is clean.There may
also be a valv e
also be a valve
positioned incorrectly.
positioned incorrectly.
Be certain water is
f lowing through the
Be certain water is
heater.
flowing through the
heater.
Heat Pump Fails to Operate
START
YesNo
Isthe Display Illum inated?,
START
Isthe DisplayIlluminated?,
If not, ensure the main
Ifnot, ensurethe main
breaker (located at the
power supply panel)
breaker (located at the
and the disc onnect
power supplypanel)
and the disconnect
switch (locat ed near
switch (locatednear
the heat pump) are
the heat pump)are
both turned ON .
both turned ON.
Problem
Problem
Solved.
Solved.
(Verif y water
temperature
(Verify water
temperature
settings are as
settings are as
desired.)
desired.)
Yes
Is the heater
Is the heater
operating correc tly ?
operating correctly?
Is the heater
Is the heater
operating correctly ?
operating correctly?
Yes
No
Is the Pool or Spa
Is the Pool or Spa
therm ost at s elect ed f or
thermostat selected for
the correct body of
water to be heated,
the correct bodyof
and hav e y ou tried
water to be heated,
and have you tried
selecting a higher
selecting a higher
temperature sett ing?
temperaturesetting?
NoYes
The heater is equipped
The heater isequipped
with a f iv e minute
with a five minute
delay . Wait at least
f ive minut es to allow
delay.Wait atleast
the timer to reset.
five minutes to allow
the timerto reset.
Is the unit operating
Is the unitoperating
correctly ?
correctly?
No
Contact
Contact
AquaCal
for Assistance at
forAssistance at
AquaCal
800-786-7751
800-786-7751
27
TROUBLESHOOTING FLOWCHART
No
Does the display read : "FS" ?
Does the displayread : "FS" ?
Heat Pump Running... but is it Heating?
(Assumes Heating Indicator Light is Illuminated)
START
START
Isthe air being discharged
degrees cooler than the
degrees cooler than the
outside air?
outside air?
rises.
rises.
Yes
Is the air being discharged
out of the top of the heat er 9-12
out ofthe top ofthe heater 9-12
HEAT ONLY MODELS: "FS"
HEATONLY MODELS:"FS"
display ed indicates air
displayed indicatesair
temperature m ay be too low to
temperature maybe too low to
support the heat er's
support the heater's
operation. Heater will remain in
operation. Heater will remain in
def rost unt il air temperat ure
defrost untilairtemperature
HEAT-COOL MO DE LS: "F S"
HEAT-COOLMODELS:"FS"
indicat es heater is def rosting.
indicates heateris defrosting.
Yes
Is the pool pum p ti mer
Is the pool pump timer
set to allow extended
set toallowextended
operation of the heater?
operation ofthe heater?
HEAT ONLY MODELS: Has t he air
HEATONLY MODELS: Has the air
tem perature rem ained abov e
temperature remained above
38ºF for sev eral hours and "FS"
38ºF for several hoursand "FS"
has been dis played t hroughout
has beendisplayed throughout
the period?
HEAT-COOL MO D E LS : H a s "FS"
HEAT-COOLMODELS: Has"FS"
remained dis played longer than
remained displayed longer than
5-minut es (I f y es , shut heater
No
HEAT ONLY MOD ELS : Ambient
condit ions too cold to operate
HEATONLYMODELS:Ambient
conditions too coldto operate
heater.
HEAT-COOL MOD ELS : "FS"
HEAT-COOLMODELS:"FS"
display ed f or 5-minutes or less
indicat es normal def rost
displayed for 5-minutesor less
No
heater.
operation.
indicates normal defrost
operation.
the period?
5-minutes (Ifyes, shutheater
of f. )?
off.)?
Yes
Yes
No
Ext end the pool pum p's
time required in c ooler
No
hours of operation t o
Extend the poolpump's
accommodate
hours ofoperation to
accommodate
additional heater run
additional heater run
time required incooler
condit ions.
conditions.
Is the heater
Is the heater
perf orming
performing
adequately ?
adequately?
Proble m
Problem
Solv e d.
Solved.
Call AquaCal
Call AquaCal
for Assistance:
for Assistance:
800-786-7751.
Yes
Problem
Problem
Solv ed.
Solved.
800-786-7751.
28
TROUBLESHOOTING FLOWCHART
Water Coming from Heat Pump
When the heater is operating,
When the heater is operating,
it is normal to produce up to 8
it is normal to produce up to 8
gallons of condensation
gallons of condensation
(water) per hour. If water
(water) per hour.Ifwater
drainage seems excessiv e,
proceed to TE STIN G.
drainage seemsexcessive,
proceed toTESTING.
Sanitizer Test
Did t he test result s
Did the testresults
indicate the presence
indicate the presence
of sanitizer?
ofsanitizer?
Yes
START
Has the "Heat ing" lamp been
If using chlorine or bromine as a pool/s pa sanit izer,
use a test strip or test k it t o determ ine whether t he
Ifusing chlorine or bromine asa pool/spa sanitizer,
water is from the pool or is normal condens ation.
use a test strip or test kit todetermine whether the
water isfrom the pool or isnormal condensation.
An alternativ e method of determining a water leak in
An alternative method ofdetermining a water leak in
the heater is to t urn the heat er of f f or a few hours,
leav e t he water pump running, and see if water
the heater is toturn the heater offfor a few hours,
continues to come f rom the heater.
leave the water pump running, and see if water
continues tocome from the heater.
No
START
illuminated?
Has the "Heating"lamp been
illuminated?
TESTIN G:
TESTING:
OR
OR
This would
This would
indicate the water
indicate thewater
present is f rom
present isfrom
normal
normal
condensation.
condensation.
No
If heater has not run recently ,
Ifheater hasnot run recently,
and water is coming
and water is coming
f rom the heater, heater m ay
from the heater, heatermay
hav e a water leak.
have awaterleak.
Turn- Off Tes t
Does water cont inue
Does water continue
No
to drain f rom t he heater
to drain from the heater
af ter the heater has been
after the heater has been
off for several hours?
off for several hours?
Yes
Proble m
Problem
Solved.
Solved.
Shut off Water Pump
Shut offWater Pump
and Call AquaCal for
and CallAquaCal for
Assistance:
Assistance:
800-786-7751
800-786-7751
Yes
29
Models:
100, 110 120, 135, and155
101, 111, 121, and 156
HEATING ONLY
&
HEATING - COOLING
30
INSTALLER-SPECIFIC
INFORMATION
FOLLOWS
Installation
Specifications
&
Controls Configuration
INSTALLER-SPECIFIC TABLE of CONTENTS
GENERAL SAFETY INFORMATION ------------------------------------33
DATA PLATE NOMENCLATURE ----------------------------------------- 33
Troubleshooting Using Displayed Codes -------------------------- 51
Mode Jumper and Positioning -------------------------------------52
Defrost Systems (described and explained) ----------------------54
32
Water Flow Pressure Switch Adjustment -------------------------- 55
CONTACTING THE FACTORY ------------------------------------------57
SAFETY INFORMATION
Notice: Heater NOT Repairable by Owner
Failure to heed the following may result in permanent
WARNING !
Heat pumps contain no owner-repairable components. Repairs must not be attempted by
untrained and/or unqualified individuals. If service is deemed necessary, contact installing
dealer or AquaCal Customer Support at (800) 786-7751.
Refrigerant Circuit Service Only by
Qualified, EPA Certified Technician
WARNING !
Heater contains refrigerant under high pressure. Repairs to the refrigerant circuit must not
be attempted by untrained or unqualified individuals. Service must be performed only by
qualified HVAC technicians. Recover refrigerant before opening system.
injury or death.
Failure to heed the following may result in permanent
injury or death.
DATA PLATE NOMENCLATURE
MODEL SERIES:
121,120, 135 155
101,111,121,156
A = 208/230-1-60
B = 208/230-3-60
D = 380/420-3-50
G = 460-3-60
H = 200/240-1-50
HEAT OPTIONS:
H = Hea t Only
R = Reversing
VOLTAGE:
CHARACTER POSITION NUMBER
123 4 5 6 7 8 9 10
120 A H x x x x x
Revisio n Le vel:
General Options:
N = No ne
Cabinet color:
B = BLACK
C = CREAM
Refrigerant:
E= R22
S = R410A
T=R407C
Controls:
D= Digital
33
SPECIFICATIONS
Physical Characteristics
34
100 & 120
-Applicable Models-
M
100, 110, & 120
EASURMENTS
S
HOWN IN
I
NCHES
SPECIFICATIONS
Physical Characteristics
NCHES
I
HOWN IN
S
135 & 155
EASURMENTS
M
-Applicable Models-
135 & 155
35
SPECIFICATIONS
Physical Characteristics
36
-Applicable Models-
M
101, 111, & 121
EASURMENTS
S
HOWN IN
I
NCHES
SPECIFICATIONS
Physical Characteristics
NCHES
I
HOWN IN
S
156
EASURMENTS
M
-Applicable Model-
37
INSTALLATION
(
)
Placement of Heater
-Indoor Installation-
Indoor installations can be problematic, and for that reason are discouraged. However, if no viable
alternative exists, indoor installations may be successfully accomplished provided very exacting criteria is addressed. Every indoor installation is unique; therefore, there are no specific guidelines for
this type of installation. If considering an indoor installation, you are strongly urged to contact the
AquaCal Engineering department (800-786-7751) for assistance prior to proceeding.
-Outdoor Installation-
Service and Operational Clearances:
•To operate correctly, heat pumps require large volumes of air moving over the heat collector.
allow adequate clearance between the heat pump and walls, fences, shrubs, or other objects.
Refer to required clearance drawings below.
•Allow five (5) feet of vertical clearance between the top of the heat pump and any roof overhang
or other obstruction. This clearance prevents cold discharge air from recirculating back into the
heat pump (recirculation would reduce the overall performance of the heat pump).
•The access panel requires removal during installation and service. Do not place plumbing, or
other items, closer than 30” from the front of the heater.
Code Required Clearances:
In addition to the previously stated clearance requirements, follow all applicable local, state, and national
requirements relative to spacing from other objects or equipment.
Required Installation Clearances
AINRUN-OFF
R
UST BE DIRECTED
M
WAY FROM
A
EATER
H
.
C
LEARANCE
30” M
VERHANG WITH
O
UTTER
G
INIMUM
, F
RONT
5FT. M
INIMUM CLEARANCE
VERHEAD
O
SQ MODELS, 12-INCHES
ALL OTHER, 6-INCHES
6”M
INIMUMCLEARANCE
(REAR)
SQ MODELS, 12-INCHES; ALL OTHER, 6-INCHES
,
,
12-
NCHES
I
SIDE
(
)
6-I
NCHES
(REAR)
EAR
R
NCHES
30-I
FRONT
(
12-
NCHES
I
SIDE
(
)
)
SIDE VIEW (NO SCALE)
FRONT-REAR-OVERHEAD
TOP VIEW (NO SCALE)
FRONT-SIDES-REAR
38
INSTALLATION - PLACEMENT OF HEATER
(continued)
Irrigation, Rainwater Runoff, and Landscape Features
•Place the heat pump away from direct rain runoff from roofs. If roof slope directs runoff into the
heater, a gutter or rain shield will be required on the roof edge above the heat pump.
•Relocate or adjust irrigation to avoid water spray directly onto the heat pump.
•Do not locate the heat pump directly adjacent to plants, shrubs, or bushes. Doing so will prevent
proper air circulation into the unit, and may inhibit access to the heater when service is needed.
•Consult drawings on previous page (Required Installation Clearances) for proper spacing to
other objects.
Equipment Mounting Pad Requirements
•
The equipment pad shall be constructed of concrete, pressure treated wood, or other codeapproved materials.
•The equipment pad shall meet all requirements of authorities having code-related jurisdiction.
•The pad shall be elevated and placed to provide adequate drainage and support to the base of
the heat pump. The pad should be essentially level with just enough pitch to drain condensate
and any other water away from the heater.
•The pad shall extend–in all directions–(at least) 3" beyond the base of the heat pump.
•Under
no circumstances shall the heater be installed directly onto the earth.
Anchoring Heater to Pad
•Follow all relevant local, state, or national requirements regarding wind load anchoring.
•When anchoring is required, use AquaCal optional Hurricane Anchoring Kits.
- AquaCal anchoring kits satisfy, completely, the very stringent Florida Building Code
Section 301.13: Wind Anchoring Requirements.
-Contact AquaCal Parts Group (800-785-7751) to obtain the correct anchoring kit for the
heater being installed.
- Please have the heater model number ready when contacting AquaCal Parts Group.
•As necessary, contact the AquaCal Technical Support Group (800-786-7751) for assistance in
determining best method of compliance.
Failure to heed the following may result in permanent
WARNING!
Installation made by unqualified persons can result in hazards to the installer and others.
The information contained throughout the “Installation” section is intended for use by qualified
heat pump installation technicians, familiar with the swimming pool/spa service industry
safety standards and methods. Installation to be performed by qualified individuals only.
injury or death.
39
INSTALLATION
Plumbing Requirements
Overview
When planning plumbing system layout, reference the plumbing schematics within this section as a
guide to the sequence of equipment, valves, fittings, etc. The plumbing configurations for typical installations are diagrammed. In operation, it is imperative the heat pump receive water flow within the
minimum-maximum ranges specified for the particular heat pump. Should the system installation
under consideration not closely match any of the schematics, contact AquaCal Technical Support
Group for advice and guidance: (800) 786-7751.
Approved Parts and Materials
Industry technology changes much too rapidly for AquaCal to specify, with exactness, any items out-
side and beyond the heat pump. What is specified is that the heater
with all applicable local, state, or national codes & standards.
In-Line Chlorine Feeders
The titanium heat exchanger tube is nearly impervious to chemical damage; however, other parts of
the heater may be damaged by concentrated chlorine.
ommendations, always place in-line chlorinators as low, and as far downstream from the heater as
possible.
In regions where hard freeze conditions are typical, the unions mentioned below allow for easy disconnection and re-connection of the heater from/to the plumbing system. Caution: Do not defeat the
function of the unions–use
Maintain Ability to Winterize
no glue on the threaded portion of the unions.
Caution: Per chlorinator manufacturers’ rec-
must be installed in accordance
Water Connections to Heat Pump
All AquaCal heat pumps are supplied with 2" PVC plumbing unions. Connection to site plumbing is
made via PVC solvent cement to the female slip socket of the plumbing unions.
Maximum Static or Operating Pressure: 50-PSI
Minimum - Maximum Water Flow Rates
• All AquaCal heaters represented within this manual are designed to operate successfully at flow
rates of 30-to-70 gallons-per-minute (GPM).
• Design the plumbing system to maintain at least 30-GPM flow through the heater under worst
case conditions (i.e.: filter fouled to 10 psi rise); the heat pump will not operate correctly, nor
reliably, with less than 30-GPM of water flow supplied. These specifications relate to heater
code-specified whole system turnover rates must be satisfied.
• If water flow rates through the heater will exceed 70-GPM, a spring-check bypass valve will be
required. Install AquaCal P.N.: 2556 5-LB bypass check valve, or bypass check valve equal to Del
Industries PN: CO-0103. See drawing, top of next page, for install location in site plumbing.
• Generally speaking, most residential pools and spas will
pump of two (2) horsepower, or larger, is used. For bypass valve placement details, see
plumbing schematic contained on next page: “…Flow Greater than 70-GPM.”
not require a plumbing bypass unless a
CAUTION !!! Installations with In-floor Cleaning Systems
In-floor cleaning systems, dependent upon varying site circumstances, may create water hammer
conditions throughout the water circulation system. Water hammer is very damaging to the plumbing
system and connected devices. Where an in-floor cleaning system is (or will be) installed, AquaCal
strongly recommends a water hammer suppression stand pipe assembly within the plumbing circuit.
For additional information, please contact AquaCal Customer Support (800-786-7751) and request
Technical Service Bulletin: AQ P-1031, Water Hammer Abatement with In-Floor Cleaning Systems.
40
only;
INSTALLATION
Plumbing Requirements (continued)
Failure to heed the following may result in damage to
CAUTION !
Water flow exceeding 70-GPM may damage titanium condenser; such damage will NOT be
covered under the equipment warranty. Install a bypass check valve (AquaCal P.N.: 2556, or
equal to Del Industries P.N.: CO-0103) whenever water flow rate may exceed 70-GPM. Contact
AquaCal Technical Support (800-786-7751) for guidance regarding testing for water flow rate.
Plumbing Schematic–Flow Exceeding 70-GPM
Bypass Check Valve
AquaCal P.N.: 2556
-or equal to-
Del Ind. PN: CO-0103
equipment.
TYPICAL POOL - FLOW GREATER THAN 70-GPM
(2-HP PUMP OR LARGER)
Plumbing Schematics – Flow 30 to 70-GPM
TYPICAL POOL - FLOW LESS THAN 70-GPMPOOL/SPILL OVER SPA - TWO PUMP SYSTEM
HEAT PUMP WITH SOLAR PANELSPOOL/SPILL OVER SPA - ONE PUMP SYSTEM
41
INSTALLATION
Plumbing Requirements
Plumbing Schematics – Flow 30 to 70-GPM
(continued)
HEAT PUMP WITH GAS HEATER BACK UP
MULTIPLE HEAT PUMP INSTALLATION
MINIMUM 30 GPM TO EACH HEATER
MINIUM SPACING 24-INCHES
Water IN & OUT Connections- Typical
(exact location varies by model)
For proper operation and maximum efficiency, piping coming from the pump and filter MUST be connected to the "IN" port of the heater. Likewise, connect piping returning to the pool/spa to the "OUT"
port of the heater. See drawing below.
PLUMBING CONNECTION DETAIL
From Pump/Filter
42
Return to Pool/Spa
INSTALLATION
Electrical Requirements
Failure to heed the following may result in permanent
WARNING!
Installation made by unqualified persons can result in hazards to the installer and others.
The information contained in this Electrical Installation section is intended for use by qualified
electrical installation technicians, familiar with electrical service industry safety standards
and methods. Electrical installation to be performed by qualified individuals only.
• Locate the equipment disconnect means within 3-feet of the heater’s electrical enclosure, or as
close to the heater as possible. Always satisfy applicable codes and standards.
injury or death.
General Requirements
• AquaCal heat pumps are designed for copper conductors, only.
• In sizing power wiring, be especially aware of up-sizing requirements necessary due to wiring
distances. Always satisfy applicable codes and standards.
• Multiple heaters installed at same site generally require special sequencing controls (an “ASC”
controller will be required). If yours is a multi-heater installation, contact AquaCal Technical
Support Group (800-786-7751) for application assistance.
••
•
Electrical installation should be by licensed electrician only.
••
Code-Specific Requirements
• The electrical installation must conform to the most current version of the National Electrical
Code, NFPA No.70, and all applicable local and state codes.
• National Electrical Code,
apply.
• National Electrical Code,
Article 680; Swimming Pools, Fountains, and Similar Installations, shall
Article 440, Air-Conditioning and Refrigeration Equipment, shall apply.
Connecting External Controllers
• See document entitled: “Connecting External Controllers to AquaCal Heat Pumps”; this
document is shipped with every AquaCal heater. For extra copies, contact AquaCal Customer
Support (800-786-7751); request literature piece: “LTP0050.”
• For Call-Flex option, reference instructions received with the Call-Flex kit.
• Please contact the AquaCal Technical Support Group (800-786-7751) concerning the application
of any external controller, Call-Flex, sequencing control, etc.
43
INSTALLATION
Electrical Requirements (continued):
Sizing the Electrical Service...
Reference the Equipment Data Plate
• AquaCal 100, 120, 135, and 155 model heat pumps have two (2) identical data plates affixed: one
can be found outside the unit, on right front corner; the second data plate is located behind the
front access panel, on the electrical enclosure cover.
• Refer to either equipment data plate for unit-specific electrical power supply requirements.
• Based on data plate information, size wiring, wiring devices, and over-current protection per
applicable codes and standards.
• Refer to drawing below for data plate items specific to electrical installation requirements. On the
installed heater data plate, the areas depicted below, numbered 1-8, will contain the information
required to size the electrical service and over-current protection.
ELECTRICAL PORTION of DATA PLATE
A Word Concerning Ground-Fault Protection
• The National Electrical Code (NEC) contains no standards requiring Ground-Fault Interruption
protection (via GFI Circuit Breaker or otherwise) of “Fixed” or “Stationary” equipment, under
article 680: Swimming Pools, Fountain, & Similar Installations, or Article 440: Air-Conditioning &Refrigeration Equipment.
• The preceding standards govern the installation of AquaCal (and other manufacturers’) heat
pumps. AquaCal heat pumps are designed, and safety tested by a certified laboratory, to be
installed under applicable standards detailed within the NEC.
• AquaCal does not recommend the use of ground fault protective devices in conjunction with heat
pumps. Service calls, found to be due to “nuisance” tripping of ground fault devices, are
Level-2 programming involves configuring the controller for specific site characteristics. To explain,
this programming is where the controller is set to operate with, or without, an external controller;
where sensor calibrations are performed; and where changes to other factory default parameters are
made.
Before transferring use of the heater to the owner, the installer
is compatible with any site-installed external controllers, and that the heater starts and operates per
the manufacturer’s specifications.
Generally speaking, the installer’s main focus within Level-2 programming will be in configuring for
external controller compatibility. And, unless instructed to do otherwise by the AquaCal Technical
Support Group, the installer should
CAUTION !
Heat pumps contain no owner-serviceable components. Owner-initiated adjustments, beyond
the controller “LOC” code, must not be attempted. If adjustments are deemed necessary, the
owner should contact installing dealer or AquaCal Customer Support at (800) 786-7751.
1. Entering Service Menu:
A. To enter the service menu, Simultaneously press and hold both the [UP ARROW] and
[DOWN ARROW] keys until [CF1] (Celsius / Fahrenheit) code appears. (Note: if “000”
displays, the User Lock Code is enabled, and the ULC pass code must be entered before
proceeding. See Owner-Level Operating Instructions, page-15: “User Lock Code Option
[ULC].” If the owner’s ULC pass code is unknown, the factory default code “0” may be used
to access controller programming.) Press the [POOL/SPA] key four times to display [LOC],
which is the entrance point for the Service Menu.
not adjust sensor calibration or dead-band values.
Failure to heed the following may result in equipment damage and voiding of manufacturer’s warranty.
must insure the controller programming
B. The [LOC] code function allows service personnel to use an access code to enter the
service menu. This section of the programming is intended for authorized factory service
personnel, only.
C. Using the [UP] and [DOWN] arrow keys, scroll the displayed number to “50.” (“50” is the
default service entry pass code.)
D. Once the correct service code is displayed, pressing the [POOL/SPA] key–once again–will
allow access to the service menu.
E. The first service parameter displayed will be [dEL] (4 -minute time delay on make).
NOTE: Pressing the [POOL/SPA] key will save the displayed value in any menu parameter,
and will advance to the next service menu juncture.
(Continued on Next Page)
45
Controls Configuration & Adjustments...
Level-2 Microprocessor Programming... continued:
2. Time Delay [dEL]:
A. With the [dEL] (4 minute time delay) code message displayed use the [UP] or [DOWN]
arrow key to select either “1” to allow the time delay to remain active or “0” to deactivate the
time delay. Not pressing any buttons for 15 seconds will allow the controller to save the
selection and return to the normal operating mode. Pressing the {POOL/SPA] key will also
save the selection and step to the next menu parameter: [JAO] (External Controller
Interface).
B. CAUTION!!!: The time delay should only be deactivated for service convenience and
be reactivated prior to placing the heat pump back is service. Failure to reset the time delay
feature could result in permanent damage to the heat pump compressor.
3. Configuring for External Controllers [JAO] or [FS2]:
A. Configuring for External Controllers Using [JAO] Selection:
NOTE: FOR WIRING TO AN EXTERNAL
CONTROLLER, REFERENCE DOCUMENT
LTP0050 SHIPPED WITH HEATER.
1) Follow the steps 1, A through 1, D to enter the service menu. Once [dEL] is displayed,
press the [POOL/SPA] key until the display shows [JAO].
2) With the [JAO] (External Controller Interface) code message displayed, use the [UP] or
[DOWN] arrow keys to select either “0” to disable the External Controller Interface, “2” to
connect a thermostat type controller (2-wire connection). Apply [FS2] configuration to
connect a thermostat selector type controller (3-wire connection); see “3. B,” below. Do
NOT use [JAO] “3.”
B. Configuring Remote Flow Switch / Automatic Thermostat Switching Using [FS2] Selection:
1) Follow the steps 1, A through 1, D to enter the service menu. Once [dEL] is displayed,
press the [POOL/SPA] key until the display shows [FS2].
2) With the [FS2] (Remote Flow Switch / Automatic Thermostat Switching) code message
displayed, use the [UP] or [DOWN] arrows to select either “0” to disable Remote Flow
Switch / Automatic Thermostat Switching, “1” to enable Remote Flow Switch / Automatic
Thermostat Switching.
NOTE:
ALL FLOW SWITCH KITS PRODUCED BY AQUACAL ARE SHIPPED WITH FULL INSTALLATION
AND PROGRAMMING INSTRUCTIONS
. PLEASE CONTACT AQUACAL CUSTOMER SUPPORT
(800-786-7751) IF ADDITIONAL COPIES OF THESE INSTRUCTIONS ARE NEEDED.
4. Water Sensor Calibration [tSC]:
must
46
If it is believed the displayed pool or spa water temperature does not match the actual
temperature, follow the steps below to verify and adjust the controller as necessary. Be certain
to use an accurate thermometer:
A. With the circulating pump in operation, and water moving through the heater, use a reliable
thermometer to measure the temperature of the pool or spa water. Be sure to measure the
water temperature away from returns. The object is to accurately determine the temperature
of the water entering the heater.
B. Once you have measured the water temperature, compare the result to the heater’s
displayed water temperature. If the water temperatures are the same or within 1
o
F, n o
calibration is necessary. If the temperatures differ by 2 to 3oF, calibration is necessary.
Perform calibration procedure as follows:
(Continued on Next Page)
Controls Configuration & Adjustments...
Level-2 Microprocessor Programming... continued:
4. Water Sensor Calibration... continued:
C. Follow the steps 1, A through 1, D to enter the service menu. Once [dEL] is displayed, press
the [POOL/SPA] key until the display shows [tSC] (Water Temperature Calibration). Using
either the [UP] or [DOWN] arrow keys, calibrate the water temperature sensor by increasing
or decreasing the numeric value displayed to match the measured water temperature. The
controller can be adjusted to +10
However, offset calibrations greater than 3oF should be avoided… Such large offsets
generally indicate problems with the method of water temperature measurement, a water
sensor not properly inserted into the well, or other equipment issues. Do NOT attempt to
mask such issues through offset calibration.
D. Once the corrected temperature is displayed, Not pressing any buttons for 15 seconds will
allow the controller to save the selection and return to the normal operating mode. Pressing
the {POOL/SPA] key will also save the selection and step to the next menu parameter:
[dSC] (Defrost Sensor Calibration).
In the event it is suspected the defrost Sensor requires calibration, the following steps must be
followed closely to ensure correct defrost operation:
o
F to –10oF from the nominal displayed temperature.
A. At the heater control panel “Mode” button, set the system to OFF.
B. Remove the heater front panel to gain access to the defrost sensor location. The defrost
sensor will be found strapped to the suction line in combination with the TXV bulb, or
strapped and separately insulated nearby the TXV bulb. Note: if unsure of sensor location,
follow–to termination–the pair of wires leading from the “FS” terminals on the controller PC
board.
C. Position a clamp-on, thermocouple-type temperature sensor onto the suction line; position
the clamp immediately adjacent to the defrost sensor. Connect the clamp-on thermocouple
to a multimeter designed to accept the input of the clamp-on device.
D. Once the heatter has remaiinted OFF for a minimum of 10-minutes, procede to step “E,”
below.
E.
Follow steps 1, A through 1, D to enter the service menu. Once [dEL] is displayed, press
the [POOL/SPA] key until the display shows [dSC] (Defrost Sensor Calibration). With [dSC]
displayed, pressing either the [UP] or [DOWN] arrow key, once, will display the current
temperature value of the defrost sensor.
F.Compare the controller’s displayed defrost sensor temperature against the reading obtained
by the clamp-on device. If the temperatures are the same, or within 1
o
F, calibration is NOT
necessary. If the temperatures differ by 2 to 3oF, calibration is necessary. The controller can
be adjusted to +10
calibrations greater than 3
o
F to –10oF from the nominal displayed temperature. However, offset
o
F should be avoided. Such large offsets generally indicate
problems with the method of suction line temperature measurement, a defrost sensor not
properly attached to the suction line, or other equipment issues. Do
NOT attempt to mask
such issues through offset calibration.
(Continued on Next Page)
47
Controls Configuration & Adjustments...
Level-2 Microprocessor Programming... continued:
5. Defrost Sensor Calibration... continued:
G. Once the correct temperature value has been selected, not pressing any buttons for
15-seconds will allow the controller to save the selection and return to the normal operating
mode. Pressing the [POOL/SPA] key will also save the selection and step to the next menu
parameter: [dBS] (Dead Band for Spa).
H. Return system controls to desired mode of operation.
6. Spa Dead Band Differential [dBS]:
In the heating mode, the dead band differential determines the number of degrees the water
temperature must fall below the set point before the thermostat closes. In the cooling mode, the
dead band differential determines the number of degrees the water temperature must rise above
the set point before the thermostat closes. When in the auto-changeover mode, the dead band
differential operates in the same manner as described above for the heating and the cooling modes.
However, in all modes, the thermostat will open when the set point is reached independent of the
direction the water temperature is changing. The factory spa dead band differential is set to 1
is strongly recommended the factory default of 1
band requires adjustment, follow the steps outlined below:
o
F remain; however, if for some reason the dead
o
F. I t
A. Follow the steps 1, A through 1, D to enter the service menu. Once [dEL] is displayed, press
the [POOL/SPA] key until the display shows [dBS] (Spa Dead Band Differential).
B. With the service menu parameter [dBS] displayed, pressing either the [UP] or [DOWN]
arrow keys, once, will display the current setting. Using the [UP] or [DOWN] arrows keys will
increase or decrease the value respectively. The differential is adjustable in 1
o
increments
from 1 to 5-degrees.
C. Once the desired dead band value has been selected, not pressing any buttons for
15-seconds will allow the controller to save the selection and return to the normal operating
mode. Pressing the {POOL/SPA] key will also save the selection and step to the next menu
parameter: [dBP] (Dead Band Pool).
7. Pool Dead Band Differential [dBP]:
In the heating mode, the dead band differential determines the number of degrees the water
temperature must fall below the set point before the thermostat closes. In the cooling mode, the
dead band differential determines the number of degrees the water temperature must rise above
the set point before the thermostat closes. When in the auto-changeover mode, the dead band
differential operates in the same manner as described above for the heating and the cooling modes.
However, in all modes, the thermostat will open when the set point is reached independent of the
direction the water temperature is changing. The factory pool dead band differential is set to 1
is strongly recommended the factory default of 1oF remain; however, if for some reason the dead
band requires adjustment, follow the steps outlined below:
o
F. I t
48
A. Follow the steps 1, A through 1, D to enter the service menu. Once [dEL] is displayed, press
the [POOL/SPA] key until the display shows [dBP] (Pool Dead Band Differential).
B. With the service menu parameter [dBP] displayed, pressing either the [UP] or [DOWN]
arrow keys, once, will display the current setting. Using the [UP] or [DOWN] arrows keys will
increase or decrease the value respectively. The differential is adjustable in 1
from 1 to 5 degrees.
(Continued on Next Page)
o
increments
Controls Configuration & Adjustments...
Level-2 Microprocessor Programming... continued:
7. Pool Dead Band Differential... continued:
C. Once the desired dead band value has been selected, not pressing any buttons for
15-seconds will allow the controller to save the selection and return to the normal operating
mode. Pressing the {POOL/SPA] key will also save the selection and step to the next menu
parameter: [LOC] (LOCK CODE).
8. Changing the Service Lock Code and “Back Door” Entry:
A. Changing the Code…
The factory default Service Lock Code is “50”. Service personnel are strongly advised to
retain the factory default setting. However, should unauthorized access to Level-2 (Service)
menu be suspected, it may be necessary to select a code other than “50”. To change the
Service Lock Code:
1) Follow the steps 1 A through 1 D to enter the service menu. Once [dEL] is displayed,
press the [POOL/SPA] key until the display shows [LOC] (LOCK CODE).
2) Press the [UP] arrow key to display the current service lock code value. With the current
value displayed the [UP] arrow key will increase the value while the [DOWN] arrow key
will decrease the value. When the desired value is displayed not pressing depressing
any buttons for 15-seconds will allow the controller to save the selection and return to
the normal operating mode. Pressing the {POOL/SPA] key will also save the selection
and step to the next menu parameter. It is recommended, however, unless
attempting to prevent tampering, that the factory setting of: “50” remain in use.
B. Back-door Access (For use when correct Service Lock Code is unknown):
1) Simultaneously press and hold the [POOL/SPA] and [UP ARROW] keys until the display
shows “888”. This operation will reset the controller to the factory default settings.
2) The factory reset will change the service lock code back to the factory setting “50”. In
addition, all other settings (including external controller configuration) arereturned to the factory defaults. See section in this manual entitled: “Factory Default
Settings” for a complete list of factory default parameters.
(End... Level-2 Microprocessor Programming)
49
Controls Configuration & Adjustments...
Microprocessor Level-2 Set Up & Calibration Codes
Service Adjustable Parameters
Code Description Factory Setting Range
[LOC] Service Lock Code 50 00-99
[dEL] 4-minute Delay on Make 1 0 / 1
[JAO] External Controller Interface 0 0 / 2 / 3
[FS2] Flow Switch/Auto T-Stat Switching 0 0 / 1
[tSC] Water Sensor Calibration Factory Calibrated +10o to –10o of display
[dSC] Defrost Sensor Calibration Factory Calibrated +10o to –10o of display
o
[dBS] Spa Dead Band Differential 1o 1
[dBP] Pool Dead Band Differential 1o 1
Microprocessor Factory Default Settings
to 5
o
to 5
o
o
Level –1 and Level-2 Default Settings
Menu Code Description Default Value Range
Level-1 [CF1] Celsius/Fahrenheit 1 0 / 1
Level-1 [ULC] User Lock Code 0 0 / 1
Level-1 [ELC] Enter Lock Code 0 00-99
Level-1 [CFO] Call / Flex 0 0 / 1 / 2
Level-1 [LOC] Service Lock Code 50 00-99
For Heat Only: OFF/HEAT
Mode Key Pad Operating Mode OFF
Thermostat Key Pad Thermostat Settings Pool & Spa OFF 45oF – 104oF
The HP7R heat pump microprocessor controller is designed to be self-diagnostic through the display
of various fault codes.
Owners & Operators: If you believe you are experiencing a problem with the heater, and feel a need to
call the factory for assistance, it will be beneficial to let the factory Service Representative know which
code is being displayed. Having this information at hand will permit the Service Representative to work
through–with you–any site related issues causing or contributing to the problem. Then, if after working
through site-related issues the heater is still not functioning correctly, the Service Representative will
offer to set up a service visit. As necessary, please Contact AquaCal Customer Support Group (800786-7751).
Dealers and Service Centers: For troubleshooting use, listed below are all possible fault messages
output by the microprocessor, what the codes mean, and possible causes with solutions for the
indicated problem. Please contact AquaCal Technical Support Group, as necessary (800-786-7751).
Failure to heed the following may result in permanent
WARNING !
injury or death.
Heat pumps contain no owner or operator repairable components. Repairs must
not be
attempted by untrained and/or unqualified individuals. If service is deemed necessary, contact
installing dealer or AquaCal Customer Support at (800) 786-7751.
Message Error Description Possible Cause
[dPO] Defrost Sensor Open Cut or loose sensor wiring
[PO]
[dPC] Defrost Sensor Shorted Short circuit in defrost sensor wiring or defective sensor.
[PC]
[LP]
[HP]
[HP5]
[LP5]
[OTA]
[FLO]
[FS] Heater in D efrost Mode
[CSE] Control System Error
[CEr] Communication Fault
Water Temperature Sensor
Open
Water Temperature Sensor
Shorted
Refrigerant System Low
Pressure Switch Open
Refrigerant System High
Pressure Switch Open
5 High Pressure Faults Within
One (1) Call for Heating or
Cooling (Lock Out Condition)
5 Low Pressure Faults Within
One (1) Call for Heating or
Cooling (Lock Out Condition)
Over Temperature Alarm<
Temperature over 110oF (Unit
Locked)
Low or No Water Flow
Detected
(HEAT-ONLY UNITS)
Cut or loose sensor wiring
Short circuit in water temperature sensor or defective sensor.
System refrigerant charge low, defective low pressure switch, clogged
evaporator coil, or defective wiring.
Low water flow, defective high pressure switch, or defective wiring.
See causes for [HP]
See causes for [LP]
Defective compressor contactor, defective controller, or defective
water temperature sensor.
Circulating pum p off, water filter dirty, isolation valves set improperly,
or defective pressure switch.
Normal function in lower air temperatures. Fan continues to run and
compressor is off. Compressor will restart when air-coil tem perature
reaches 38
Controller may need to be reset. Disconnect then reconnect power to
controller. If error continues, replace control board, display board, or
both.
Loss of communication between main board and display board. Reset
controller or replace communication cable.
o
F or above.
51
Controls Configuration & Adjustments...
Microprocessor Mode Jumper Positioning
Mode Jumper Explained
The HP7R microprocessor is designed to operate as a Heat-Only or a Heating & Cooling controller.
The selection between the two choices is made through the positioning of a mode jumper contained
on the microprocessor board. The position of the jumper is set at the factory, and is dependant upon
the design of the heater being controlled. Heaters designed to heat only, have the microprocessor
mode jumper set in the heat-only mode; heaters capable of both heating and cooling (reversing), have
their microprocessor mode jumper set to permit control of both heating and cooling.
Important: The position of the mode jumper must match the capabilities of the heat pump. Simply
placing the mode jumper to the heating and cooling position, with a heater designed to heat only, will
not make a heat-only heater heat & cool. In fact, a mis-positioned mode jumper will cause heater
control difficulties.
Verifying the Mode Jumper Position is Correct
1. Apply electrical power to the heater.
2. Review the available modes by repeatedly pressing the [MODE] key:
A.
Heat-Only Models: the [MODE] key functions should appear as: [OFF] and [HEA].
B.
Heat-Cool Models (Icebreakers): the [MODE] key functions should appear as: [OFF], [HEA],
[COO], and [AHC].
3. If the modes do not display correctly for the heater being serviced, the mode selector jumper,
located on the microprocessor PC board, is likely placed in the wrong position. To correct this
condition, the jumper will need to be repositioned. See repositioning instructions, below.
Repositioning the Mode Jumper
Use this procedure if [MODE] key functions indicate jumper positioning is incorrect. The mode
jumper is located on the microprocessor controller board, within the heater’s electrical enclosure.
Failure to heed the following may result in permanent
WARNING !
This is
and/or unqualified individuals. Risk of Electrical Shock… Ensure all electrical power to the
heater has been disconnected prior to removing the heater front access panel. Leave
electrical power disconnected throughout the following jumper repositioning procedure.
1. To access the jumper, disconnect electrical power and remove the heater front entry panel; then,
remove the metal cover from heater electrical enclosure. For layout details of the PC control
board, see figures on next page.
2. Locate the mode jumper in the upper right hand corner of the PC control board; per the figures
on the following page, identify the correct location for the jumper. If the jumper is found to be
incorrectly positioned, gently disengage the jumper by pulling it directly away from the control
board.
NOT an owner or operator procedure. Repairs must not be attempted by untrained
injury or death.
3. Correctly reposition the jumper, leaving one pin uncovered.
(2) pins: one always being the middle pin, and the other the correct pin for the features of the
heat pump.
The microprocessor controller monitors the heater’s air-coil temperature, minimizing air-coil freezeup during cooler weather conditions. If the controller senses air-coil temperatures conductive to making ice, the heater’s compressor operation is interrupted while the fan is allowed to continue in operation.
With the compressor off, the air-coil begins to warm to the surrounding air temperature. When air-coil
temperatures rise above approximately 38
In the event air temperatures remain below approximately 38
the air temperature rises above 38oF. The unit will not heat the water as long as the compressor
remains off.
During defrost cycles, when the controller has stopped compressor operation, the display will read:
[FS].
DEFROST CYCLE (HEAT & COOL UNITS):
The microprocessor controller, in conjunction with the defrost sensor, constantly monitors the heater’s
evaporator (air-coil) temperature. Should the controller sense ice or frost has formed on the evaporator, sufficient in amount as to affect the heater’s performance, an active defrost cycle (more below) is
initiated. Before initiating a defrost command, the controller defrost logic looks at both the air-coil
temperature, and the length of time the coil has remained at an ice-making temperature.
Active defrost involves using hot refrigerant gas, from the compressor, to rapidly remove ice or frost
from the evaporator coil. In practice, during a hot gas defrost cycle, valving, internal within the refrigerant system, reverses the flow of the refrigerant; this reversal of flow temporarily makes the air-coil the
condenser. During hot gas defrost, the air-coil warms very quickly, and accumulated ice and frost is
rapidly melted. Under most conditions the evaporator will be completely cleared in under 5-minutes.
HEAT & COOL DEFROST SEQUENCE DETAILS:
•When the controller senses air-coil temperatures conductive to making ice, the unit will enter a
50-minute defrost delay (counting) period.
o
F, the compressor is restarted and heating resumes.
o
F, the compressor will remain off until
•During the counting period, the fan and compressor will continue to operate, and the water will
continue to be heated. During the counting period it is normal to see a moderate amount of frost
and ice formation on the air coil.
•If, after the 50-minute counting period, the controller senses a need to defrost:
1. The refrigerant circuit reversing valve will be activated, changing the flow of hot refrigerant
gas from the pool water heat exchanger to the air-coil.
2. Fan operation will be suspended, permitting maximum heating of the air-coil.
3. The reverse cycle will continue until either:
A. The air-coil attains a predetermined temperature (indicative of total defrost), or;
B.
Until 10-minutes have elapsed (regardless of total defrost having occurred).
•During hot gas defrost cycles, the compressor will not deactivate; rather, the compressor will
continue operation throughout the sequence. Upon completion of the defrost cycle (as
terminated per “A” or “B,” above), the reversing valve will be deactivated, fan operation will
recommence, and water heating will resume.
54
Controls Configuration & Adjustments...
Water Flow (Pressure) Switch Adjustment
Occasionally, plumbing system design features will create a situation whereas the heater will abnormally cycle on the water flow circuit. This situation will be evident if the circulator pump is operating,
the filter is clean, and all water valves are set to flow water through the heater– but the error code:
“FLO” remains displayed (or displays intermittently). In these rare instances where the factory water
pressure switch (WPS) setting will not satisfy site conditions, a WPS adjustment, to enable normal
heater operation, is possible.
Failure to heed the following may result in permanent injury
WARNING !
WPS adjustment procedure to be performed by experienced service personnel only; procedure is
NOT a homeowner-based task, and must not be attempted by individuals lacking adequate electrical
and mechanical experience. BEWARE: ROTATING FAN PROP HAZARD: fan may start during
water switch adjustment. Keep hands clear of fan blade at all times.
Locate Water Pressure Switch and Identify Type:
1. Before proceeding with switch adjustment, be absolutely certain the heater is receiving correct
water flow. Leave circulation pump operating during water pressure switch (WPS) adjustment
process.
or death.
2. Remove heater front cover and locate the water pressure switch. The switch will be found
attached outside of the electrical enclosure, at lower edge; exact location will vary by heater
model (see photo P-1, on following page).
3. AquaCal heat pumps may come equipped with either of two (2) water pressure switches: “Len
Gordon” or “TecMark” brand (see photos P-2 and P-3, on following page, to determine which
brand pressure switch is installed). The adjustment procedures differ slightly between the two
brands.
To Adjust a “Len Gordon” Switch:
1. Locate the black, rectangular plastic tab, located on the forward-facing side of the switch
(reference P-2 on page following). The black rectangle is a wheel lock tab; slide the tab fully
LEFT to unlock the adjustment wheel.
2. With water pump operating, and electrical power supplied to the heater,
the adjustment wheel TOWARDS you until the FLO code (just) disappears. WARNING: watch
for rotating fan blade; depending upon the state of the control circuit time delay, the heater may
start simultaneous with the WPS adjustment.
3. Once the adjustment has been completed, slide the wheel locking tab fully back to the right-
hand, locked position.
To Adjust a “TecMark” Switch:
1. (Reference photo P-3 on page following.) TecMark switches do
lock.
not have an adjustment wheel
slowly rotate the top of
2. With water pump operating, and electrical power supplied to the heater,
the adjustment wheel AWAY from you until the until the FLO code (just) disappears.
watch for rotating fan blade; depending upon the state of the control circuit time delay, the heater
may start simultaneous with the WPS adjustment.
slowly rotate the top of
WARNING:
55
Controls Configuration & Adjustments...
Water Flow (Pressure) Switch Adjustment... continued:
To Complete the Adjustment Procedure– Either Brand Switch:
1. With electrical power remaining ON to the heater and heater operating, shut off the power to the
circulating pump. If the switch has been correctly adjusted, when the water pump stops, the
heater will shut off and the “FLO” code will display.
CAUTION: If the heater continues to operate with water pump off, readjust water pressure switch
to ensure heater will not run without water flow.
2. Reinstall heater front cover.
P-2, Len Gordon Style Switch
P-1, WPS Location
P-3, TecMark Style Switch
SHOULD ADJUSTMENT OF THE WATER PRESSURE SWITCH PROVE UNSUCCESSFUL, CONTACT
AQUACAL TECHNICAL SUPPORT (800-786-7751); SITE-SPECIFIC FACTORS MAY REQUIRE
THE INSTALLATION OF AN EXTERNAL FLOW SWITCH
.
56
CONTACTING THE FACTORY
What We Need to Know When You Call Us
If you should need to call AquaCal for service or parts, please have the following information ready:
Model: ________________________________
Look for this information on
sticker located at top of front
cover of this manual; otherwise,
Serial Number: __________________________
Installation Date: ________________________
}
see data plate on side of heater.
Refer to installer’s invoice for
}
this information.
Having the above information ready will speed the service process and allow
us to respond more quickly. A brief but concise description of what the unit is,
or is not doing, will also help us to help you.
Please call toll-free at: (800) 786-7751. We are here to serve you from 8 a.m.
to 5 p.m. EST, Monday through Friday. If calling after hours, our voice mail
system will handle your call. Be sure to leave your name, complete address,
and telephone number.
If you prefer, you may FAX the information to: (727) 824-0847.
(Be certain to provide your full address and a daytime telephone number.)
elicitaciones por su sabia decisión de comprar una bomba de calor AquaCal y
F
hacerla parte de los equipos de su hogar. Desde 1981 AquaCal ha mantenido el
liderazgo en la fabricación de bombas de calor para piscinas y spas. Su nueva
bomba de calor no es sólo una inversión importante, pero es también el método más
efectivo por costo para calentar las piscinas y los spas. Por ejemplo, su nueva bomba
de calor es 400% más eficiente que el calentar con gas, y cuando se compara con
calentamiento por resistencias eléctricas, la bomba de calor es cerca de 600% más
eficiente. Para su tranquilidad y seguridad su nueva bomba de calor es fabricada con
la más alta calidad y para ofrecerle la mayor eficiencia, y además está diseñada y
construida para proveerle años de operación libres de problemas.
Si más adelante usted necesitara de ayuda para operar o mantener su bomba de
calor, usted encontrará que nuestro equipo de técnicos, de servicio al cliente y su
distribuidor de AquaCal es el más extenso, más calificado y lo más importante el de
más fácil acceso en toda la industria de las bombas de calor para piscina y spa.
“Para su tranquilidad y seguridad su nueva bomba de calor es
fabricada con la más alta calidad y para la mayor eficiencia y está
diseñada y construida para proveerle años de operación libres de
problemas”
5
CARACTERISTICAS IMPORTANTES DE SU
NUEVA BOMBA DE CALOR AQUACAL
Intercambiador de Calor ThermoLink
El corazón de su nueva bomba de calor es el intercambiador de calor (patentado)
ThermoLink
falla del intercambiador de calor. Normalmente los intercambiadores de calor son
fabricados de una aleación de Cobre-Níquel. Este material en Cobre-Níquel es
susceptible al ataque de los elementos purificadores utilizados en las piscinas y spas,
y por otras condiciones de químicos no bien balanceados. Una vez el intercambiador
de calor falla, la bomba de calor es arruinada. El tubo del intercambiador de calor
ThermoLink de AquaCal, está hecho de titanio y es por esto que es prácticamente
impenetrable al daño químico del agua.
®
. La principal causa de un daño prematuro en una bomba de calor es la
®
Compresor de Serpentín (Scroll)
El compresor de serpentín tiene un 50% menos de partes en movimiento que un
compresor de tipo-pistón normal. Esto significa una mayor confiabilidad y una
eficiencia superior. Los compresores de serpentín también tienen una operación más
silenciosa que los de tipo de pistón. Y mientras todas las bombas de calor de AquaCal
son reconocidas por su baja emisión de ruido durante su operación, si su bomba de
calor es el modelo SuperQuiet
silenciosa que cualquier otro equipo instalado en el conjunto de equipos de su piscina.
TM
, es muy seguro que su bomba de calor es más
Controlador Digital
Microprocesador de base digital, el cual controla la temperatura hasta en 0.56°C del
punto de selección. El controlador también le permite al usuario el pre-definir
diferentes temperaturas para el agua de la piscina y spa y el bloquear los controles
por medio de un código para evitar que alguien diferente cambie el ajuste o selección.
Cubierta a Prueba de Corrosión
La cubierta de su bomba de calor está hecha de un material plástico resistente y
protegido contra los rayos Ultravioleta, la cual nunca se oxida, decolora o corroe.
Usted puede contar con que la cubierta de su bomba de calor mantendrá un
apariencia de nueva con sólo una lavada ocasional y si usted lo desea con aplicarle
un poco de cera líquida.
(Continúa en la Próxima Página)
6
CARACTERISTICAS IMPORTANTES DE SU NUEVA
¿
¿
¿
¿
BOMBA DE CALOR AQUACAL (continuación)
Capacidad de Calentar y Enfriar
Esta característica lo coloca a usted en control total durante todo el año. Usted puede
calentar su piscina o spa con una mayor confiabilidad y eficiencia con cualquiera de
nuestros otros modelos de bombas de calor, pero con solo presionar una tecla usted
también puede enfriar su piscina o spa hasta lograr temperaturas refrescantes durante
los meses de un caliente verano. Para climas más fríos las bombas de calor del
modelo Icebreaker
®
ofrecen ventajas únicas sobre los modelos de descongelación
pasiva. Por favor lea más al respecto en el tema a continuación.
Solo en los Modelos Icebreaker® y SuperQuiet
Descongelación por Gas Caliente
TM
Las bombas de calor con descongelación por gas caliente, está exclusivamente
equipadas para llevar a cabo una descongelación activa. Esta descongelación activa
se lleva a cabo dirigiendo el gas refrigerante caliente al colector de calor o evaporador
(radiador), derritiendo en cuestión de pocos minutos la escarcha y el hielo que se
hayan acumulado, y luego procederá a continuar con el proceso de calentamiento.
Bajo climas muy fríos, las bombas de calor normales, se mantienen apagadas por
congelamiento durante extensos períodos de tiempo. Con su bomba de calor con
descongelación por gas caliente usted puede extender su temporada de utilización de
la piscina mucho más que con una bomba de calor normal, debido a su habilidad de
operar aún bajo temperaturas de congelamiento.
Solo en los Modelos Icebreaker® y SuperQuiet
POR FAVOR CONTINUE CON LA LECTURA DE ESTE MANUAL PARA
FAMILIZARIZARSE CON TODAS LAS CARACTERISTICAS, LA OPERACION
SEGURA Y EL CUIDADO DE SU NUEVA BOMBA DE CALOR.
TM
7
COMO FUNCIONA UNA BOMBA DE CALOR
LA SIGUIENTE EXPLICACION TIENE COMO FIN EL AYUDARLE A ENTENDER
QUE DEBE USTED ESPERAR DE SU NUEVA BOMBA DE CALOR
Una Bomba de Calor no Produce Calor…
Las bombas de calor son tan extraordinariamente eficientes que no necesitan
producir calor con el fin de calentar el agua de la piscina o el spa. Más bien, la
bomba de calor simplemente transfiere el calor del aire del medio ambiente al agua
de la piscina o el spa.
Si se considera un “0” (cero) absoluto como el punto donde hay una total ausencia de
calor, esto ocurrirá una temperatura de -237°C. Se vuelve evidente que el aire del
medio ambiente así se encuentre a una temperatura relativamente fría de 13°C
todavía contiene grandes cantidades de energía calórica. Es precisamente esa
abundante energía calórica que la bomba de calor captura y la transfiere al agua de
su piscina o spa.
Calor Removido del Aire
Sale Aire Fresco
Salida de Agua Caliente
Aire Caliente
Entra a la
Bomba de
Calor
Entrada de
Agua Fría
8
INFORMACION DE SEGURIDAD
Si usted opera y mantiene apropiadamente su bomba de calor, esta le proveerá año
tras año una operación segura y económica. Sin embargo, como con cualquier otro
aparato eléctrico o mecánico, para obtener lo máximo de su bomba de calor –
mientras se provee una seguridad personal para usted y los otros – ciertos factores
operacionales y de mantenimiento deben ser tenidos en cuenta.
Asimismo, cualquier reparación o servicio en su bomba de calor debe ser llevada a
cabo únicamente y exclusivamente por personal de servicio con experiencia, excepto
por unos pocos detalles menores de mantenimiento que el propietario puede realizar
(explicados más adelante en este manual). Si usted, el propietario de la bomba de
calor, sospecha que su bomba de calor no está operando apropiadamente, al referirse
a la sección de este manual titulada como “Determinación y Solución de Problemas”,
usted podrá determinar si requiere que se presente el técnico de servicio para una
posible reparación. Su distribuidor autorizado puede ser la fuente de servicio o
también lo atenderán para ayudarlo llamando al personal de Asistencia al Cliente de
AquaCal al 727-823-5642 o por medio de la línea de HornerXpress Worldwide (954)
938-5355 para asistencia en Español. Para preguntas concernientes con instalación,
modificaciones, operación, servicio y mantenimiento por favor contacte a su
distribuidor autorizado más cercano o el Departamento de Asistencia al Cliente de
AquaCal al número telefónico mencionado anteriormente o para asistencia en
Español a HornerXpress Worldwide al (954) 938-5355. Las garantías de la bomba de
calor pueden ser anuladas si ésta ha sido instalada, operada, mantenida o reparada
indebidamente.
Adicionalmente, otros factores que pueden anular la garantía de la bomba de calor
son: métodos de instalación no aprobados por el fabricante, modificaciones fuera de
lo normal, pobre o incorrecto mantenimiento, servicio llevado a cabo por personal no
autorizado, y el uso inapropiado de la unidad. Todo esto puede tener como
consecuencia heridas personales y / o daños a propiedades. Para su seguridad
personal y para evitar daños en su bomba de calor es de suma importancia leer,
entender y obedecer las instrucciones de seguridad que se encuentran en la unidad y
que se explican en este manual.
(Continúa en la Próxima Página)
9
INFORMACION DE SEGURIDAD(continuación)
A lo largo de este manual usted encontrará las siguientes dos señales de seguridad
cada que se requiera de su atención específica. Por favor tenga en cuenta que
“ADVERTENCIA”, se refiere a la seguridad personal y “PRECAUCION”, se refiere a
evitar daños en el equipo.
El no hacer caso a lo siguiente puede
¡ADVERTENCIA!
Este símbolo de “Advertencia” aparece en este manual donde se requiere de
atención especial para la seguridad personal. (Instrucciones específicas
aparecerán en este cuadro).
¡PRECAUCION!
Este símbolo de “Precaución” aparece en este manual donde se requiere de
atención especial para evitar daños al equipo. (Instrucciones específicas
aparecerán en este cuadro).
causarle heridas permanentes o la
muerte
El no hacer caso a lo siguiente puede
causarle daños al equipo.
Aviso: La Bomba de Calor NO Debe Ser Reparada Por El Propietario
El no hacer caso a lo siguiente puede
¡ADVERTENCIA!
Las Bombas de Calor no tienen componentes que sean reparables por el
propietario. Personas no calificadas y sin entrenamiento NO de debe intentar hacer
reparaciones en la bomba de calor. Si se considera que es necesario darle servicio
a la unidad por favor contacte a su distribuidor autorizado más cercano o al
Departamento de Asistencia al Cliente de AquaCal al número telefónico 727-8235642 o para asistencia en Español a HornerXpress Worldwide al (954) 938-5355.
causarle heridas permanentes o la
muerte
Servicio al Circuito del Refrigerante – Realizado por un Técnico
Calificado y con Experiencia en Aire Acondicionado
El no hacer caso a lo siguiente puede
¡ADVERTENCIA!
La Bomba de Calor contiene gas refrigerante a alta presión. Las reparaciones en el
circuito del refrigerante NO
sin entrenamiento. El servicio debe ser hecho únicamente por técnicos calificados
en refrigeración y aire acondicionado. Antes de abrir el sistema se debe recuperar
o extraer gas refrigerante a un contenedor apropiado para aliviar la presión interna.
deben ser llevadas a cabo por personas no calificadas y
causarle heridas permanentes o la
muerte
(Continúa en la Próxima Página)
10
INFORMACION DE SEGURIDAD(continuación)
Seguridad en la Temperatura del Agua
El no hacer caso a lo siguiente puede
¡ADVERTENCIA!
Una inmersión prolongada en agua más caliente que la temperatura normal del
cuerpo puede causar una condición conocida como Hipertermia. Los síntomas de
la hipertermia son: inconciencia de un peligro inminente, falta de percibir el calor,
falta de reconocer la necesidad de salirse del spa y pérdida del conocimiento. El
ingerir alcohol, drogas o medicamentos puede aumentar en alto grado el riesgo de
una hipertermia fatal. Adicionalmente personas que tengan historial médico de
condiciones adversas o mujeres en gestación, deben consultar al médico antes de
utilizar una tina caliente o un spa. Los niños y los ancianos deben ser supervisados
por un adulto responsable.
Seguridad con la Química del Agua
causarle heridas permanentes o la
muerte
El no hacer caso a lo siguiente puede
¡ADVERTENCIA!
Un balance químico inapropiado del agua puede ocasionar un serio peligro para la
salud. Para evitar este tipo de riesgos, se debe mantener el balance químico del
agua de la piscina o el spa de acuerdo a los parámetros detallados más adelante
en este manual.
¡PRECAUCION!
A pesar de que su nueva bomba de calor viene equipada con un intercambiador de
calor a base de titanio el cual es prácticamente impenetrable al daño químico del
agua, un balance inadecuado en la composición química del agua, puede causar
daños costosos a la bomba de circulación, el filtro, el recubrimiento de la piscina,
etc. Para evitar daños en el equipo se debe mantener el balance químico del agua
de la piscina o el spa de acuerdo a los parámetros detallados más adelante en este
manual.
causarle heridas permanentes o la
muerte
El no hacer caso a lo siguiente puede
causarle daños al equipo.
11
GUIA RAPIDA DE CALENTMIENTO -
ARRANQUE Y PARADA
Esta corta información se provee con el fin de ayudar a los instaladores, personal de
servicio y propietarios. El objetivo de esta sección es el de proveer un rápido acceso
a información operacional muy básica. Para las personas que rutinariamente estarán
instalando, manteniendo, prestando servicio y operando esta bomba de calor, es
altamente recomendable leer en su totalidad este manual. En éste los términos
Bomba de Calor, Calentador y Unidad son utilizados como sinónimos.
Estas instrucciones se dirigen al control local de la bomba de calor,
independiente de un controlador externo. Propietarios
un controlador externo, por favor contacte a su distribuidor de instalación para
las instrucciones de operación.
Estas instrucciones son una guía rápida del arranque en el modo de calentamiento.
Los propietarios de unidades de Calentamiento- Enfriamiento se deben referir a
la sección Programación para el Nivel del Propietario
página número 20 de este manual, y así utilizar todas las características de esta
bomba de calor.
1. Verifique que Haya Suministro de Corriente Eléctrica en la Bomba de Calor:
: si su instalación incluye
, la cual se encuentra en la
A. Asegúrese de que la unidad esté conectada a la corriente eléctrica. La pantalla
del controlador debe estar iluminada.
B. Si en la pantalla no se visualiza nada, asegúrese de que el corta-circuitos
eléctrico y la desconexión de la bomba de calor, tienen el interruptor en la
posición de encendido (ON).
C. Por el momento deje apagada la bomba de circulación.
2. Ajuste de los Controles de la Bomba de Calor (refiérase a la disposición del
tablero de control – página 16):
PROPIETARIO: Si la bomba de calor está conectada a un controlador Call-Flex,
refiérase a la programación Call-Flex en la sección Programación para el Nivel del
Propietario la cual se encuentra en la página 27 de este manual.
INSTALADOR: Si la bomba de calor está conectada a un controlador externo,
refiérase a la sección Instrucciones Específicas para el Distribuidor, las cuales se
encuentran en la página 44 de este manual.
A. Las selecciones del propietario pueden ser ajustadas sin que haya flujo de
agua. Una vez la bomba de calor esté conectada a la energía eléctrica, sin que
haya flujo en el sistema, en la pantalla se visualizará el código de mensaje
[FLO].
(Continúa en la Próxima Página)
12
GUIA RAPIDA DE CALENTAMIENTO - ARRANQUE Y
PARADA (continuación)
B. Presione la tecla MODE, hasta que aparezca en la pantalla el mensaje de
Calentamiento – HEA. Esta acción habilitará las demás teclas de
programación.
C. Por medio de las teclas [POOL / SPA], seleccione el modo PISCINA (POOL).
Este ajuste será verificado por medio de una luz indicadora localizada al lado
izquierdo de la pantalla, mostrando que el control de PISCINA (POOL) ha sido
seleccionado (Si se está calentando sólo el spa, baje la temperatura de la
PISCINA (POOL) utilizando la tecla de flecha ABAJO, hasta que aparezca OFF
en la pantalla y luego proceda con el paso “E”).
D. Utilice las teclas de FLECHA ARRIBA / ABAJO para ajustar la temperatura
deseada para el agua de la piscina.
E. Si la bomba de calor se va a utilizar para calentar un spa, utilice las teclas
[POOL / SPA], para seleccionar SPA, Este ajuste será verificado por medio de
una luz indicadora localizada al lado izquierdo de la pantalla, mostrando que el
control de SPA ha sido seleccionado luego utilice las teclas de FLECHA
ARRIBA / ABAJO para ajustar la temperatura deseada para el agua del spa (si
se está calentando sólo la piscina, baje la temperatura de la PISCINA (POOL)
utilizando la tecla de flecha ABAJO, hasta que aparezca OFF en la pantalla).
F. En este momento ya están ajustados los controles de la bomba de calor para
mantener la temperatura deseada para la Piscina y / o el Spa.
3. Inicio del Calentamiento:
A. Asegúrese que el MODO está en el ajuste de calentamiento HEA, luego
dependiendo de cual cuerpo de agua se quiera calentar, utilice las teclas
[POOL / SPA] para seleccionar bien sea la piscina o el spa.
B. Coloque las válvulas de agua externas en la posición correcta para permitir que
el flujo de agua provenga del cuerpo de agua seleccionado, pase a través de la
bomba de calor y retorne nuevamente al mismo cuerpo del agua.
C. Arranque la bomba de circulación y luego de cuatro (4) minutos, dependiendo
del estado del temporizador interno del controlador, la bomba de calor se
encenderá. El cuerpo de agua seleccionado se calentará y se mantendrá a la
temperatura escojida según los ajustes determinados anteriormente en:
“Ajuste de los Controles de la Bomba de Calor”.
(Continúa en la Próxima Página)
13
GUIA RAPIDA DE CALENTAMIENTO - ARRANQUE Y
PARADA (continuación)
D. Una vez en operación, cada que la temperatura del agua (mostrada en la
pantalla) descienda por debajo del punto de selección, la bomba de calor
comenzará a calentar a luego de un tiempo inicial de retraso de 4 minutos.
NOTA: El controlador de la bomba de calor tiene un retardador de tiempo para corto circuito.
Si la operación de la unidad se interrumpe, el arranque se retardará
aproximadamente por 4 minutos.
4. Programación del Tiempo de Operación de la Bomba de Circulación:
La mayoría de los sistemas de piscina / spa utilizan un temporizador o un
controlador de múltiples funciones, para administrar el tiempo de operación de la
bomba de circulación. Si su sistema tiene un equipo como éstos, se deben seguir
las siguientes instrucciones:
A. Será indispensable permitir que la bomba de circulación opere continuamente
hasta que se alcance la temperatura deseada. Si un temporizador está
controlando la bomba de circulación, será necesario invalidar el temporizador,
para permitir que la bomba circule el agua por un período de 24 horas.
B. Una vez se ha obtenido la temperatura deseada (2 a 4 días) restablezca el
dispositivo de control de la bomba de circulación. Durante los meses de
temperaturas más frías, se requerirá de tiempos de operación más largos –
generalmente de ocho a doce horas al día.
C. Una bomba de calor sólo puede operar cuando la bomba de circulación está
operando. Por lo tanto durante los meses de temperaturas más frías será
necesario extender el tiempo de operación diario de la bomba de circulación.
Este incremento en el tiempo de operación es necesario para contrarrestar las
pérdidas de calor debido a las influencias del clima.
(Continúa en la Próxima Página)
14
GUIA RAPIDA DE CALENTAMIENTO - ARRANQUE Y
PARADA (continuación)
5. Operación Continua y Agua Alrededor de la Unidad:
Condensación:
continuamente por un período de tiempo, se podrá observar agua circulando en
los alrededores de la unidad. Esta agua o humedad es el producto de la
condensación que se genera al transferir el calor del aire al agua de la piscina o
spa. Es común que resulten de 6 a 8 galones de agua por hora de operación, si la
humedad del medio ambiente es alta. De forma contraria, si el aire del medio
ambiente carece de humedad es muy probable que no
(Para determinación y solución de problemas, ver la página 39, en el tema “Agua
Saliendo de la Bomba de Calor.”)
6. Parar la Bomba de Calor:
A. Seleccione: OFF por medio de la tecla MODE. Al apagar de esta forma la
bomba de calor se mantendrán los ajustes o selecciones del controlador.
B. Una interrupción en el flujo de agua – como cuando el temporizador de la
bomba de circulación está en control – también apagará la operación de la
bomba de calor.
Luego de que la bomba de calor ha estado operando
se genere condensación.
(Final de Guía Rápida de Calentamiento, Arranque y Parada)
15
CONTROLES DE LA BOMBA DE CALOR
c
d
e
f
g
h
i
j
Disposición del Tablero de Control
(La Apariencia Puede Variar por Modelo)
Teclas de Control, Luces Indicadoras, y Pantalla
(Como se Indica con los Números en los Círculos)
. Tecla [POOL / SPA] – Selecciona el termóstato de la piscina o el spa.
. Luz Indicadora de Enfriamiento – Indica que la unidad está enfriando. (Nota:
Esta no funciona en los modelos de sólo calentamiento).
. Flecha Arriba – Incrementa el ajuste de la temperatura. (La selección máxima es
de 40°C – 140°F).
. Flecha Abajo – Disminuye el ajuste de la temperatura. (La selección mínima es
de 7.2°C – 45°F).
. Luz Indicadora de Calentamiento – Indica que la unidad está calentando.
. Tecla MODE – En los modelos de enfriar y calentar utilícela para seleccionar
entre Calentamiento, Enfriamiento, Cambio Automático y Apagado. En las
unidades de sólo calentamiento utilícela para seleccionar entre calentamiento y
apagado de la unidad.
. Luz Indicadora del Spa – Indica que el termóstato del spa está accionado.
. Luz Indicadora de la Piscina – Indica que el termóstato de la piscina está
accionado.
(Continúa en la Próxima Página)
16
CONTROLES DE LA BOMBA DE CALOR (continuación)
k
l
Teclas de Control, Luces Indicadoras, y Pantalla
. Pantalla LED – Muestra la temperatura del agua cuando no se están presionando
otras teclas. Muestra la temperatura deseada cuando la tecla de FLECHA
ARRIBA o FLECHA ABAJO son presionadas. También muestra los códigos de
operación, programación y de posibles fallas de la unidad.
. Luz de Temperatura Deseada – Indica que la temperatura seleccionada está
siendo mostrada en la pantalla. Indica también que la temperatura seleccionada
está siendo cambiada debido a que se está presionando la tecla FLECHA
ARRIBA o FLECHA ABAJO.
(11). Luz de Temperatura del Agua – Indica que la temperatura actual del agua de la
piscina está siendo mostrada.
17
CONTROLES DE LA BOMBA DE CALOR (continuación)
Códigos de Operación y Programación
LOS SIGUIENTES CODIGOS APARECEN EN LA
PANTALLA COMO PARTE DE LA OPERACION
NORMAL DE LA BOMBA DE CALOR
FLO. . . . No se detecta flujo de agua. Este código aparece cada que la bomba de
circulación esté apagada o cuando la bomba de calor no este recibiendo la
cantidad de flujo de agua apropiada.
OFF. . . . El sistema está apagado. Este código aparece cada que la bomba de calor
es apagada al utilizar la tecla de MODE, o cuando el punto de ajuste de la
temperatura ha sido disminuido por debajo de 7.2°C (45°F).
CFI. . . . Selección de grados Celsius – Fahrenheit. Este es un paso de entrada de
programación para seleccionar las unidades con las cuales se quiere ver la
temperatura del agua en la pantalla.
ULC. . . . Código de bloqueo del usuario. Este es un paso de entrada de
programación; cuando se activa, se continúa con el próximo nivel del menú:
ELC.
ELC. . . . Entrada del código de bloqueo. Este es un paso de entrada de
programación; le permite al usuario el seleccionar un código secreto,
limitando así el acceso a las selecciones programadas por el propietario.
CFO. . . . Opciones de Call Flex. Este es un paso de entrada de programación.
Cuando se utiliza con el equipo de adicional Call/Flex de AquaCal, permite
el uso de las funciones de CALL y FLEX (Ver en la página 27 de este
manual).
(Continúa en la Próxima Página)
18
CONTROLES DE LA BOMBA DE CALOR (continuación)
Códigos de Operación y Programación
FS. . . . Bomba de calor en modo de descongelación (aplicable únicamente en
bombas de calor solo de calentamiento). Este código es normal que
aparezca en la pantalla cuando se presentan períodos de temperaturas
bajas en el medio ambiente. Pueden ocurrir las siguientes posibilidades:
Unidades solo de Calentamiento:
el compresor está apagado. El compresor volverá a arrancar cuando la
temperatura del aire en el evaporador se incremente aproximadamente a
3.3°C (38°F).
LOC. . . . Este es un paso de entrada a la parte de Servicio (no debe ser utilizado por
el propietario). El código [LOC] le permite al personal de servicio entrar un
código de fábrica para poder acceder al ajuste de calibración o reconfigurar
ajustes según los parámetros que dependan de la localidad. Los ajustes de
servicio únicamente están disponibles para el personal de instalación y
servicio autorizados.
¡PRECAUCION!
Las Bombas de Calor no tienen componentes que sean reparables por el
propietario. Este no debe intentar hacer ajustes por medio del código [LOC] del
controlador. Si se considera que los ajustes son necesarios, el propietario debe
contactar a su distribuidor autorizado más cercano o al Departamento de Asistencia
al Cliente de AquaCal al número telefónico 727-823-5642 o para asistencia en
Español a HornerXpress Worldwide al (954) 938-5355
El ventilador continúa funcionando pero
El no hacer caso a lo siguiente puede
causarle daños al equipo y anular su
garantía
19
CONTROLES DE LA BOMBA DE CALOR (continuación)
Arranque y Ajuste de Controles de Operación
Instrucciones del Nivel de Programación del Propietario
Dentro de esta sección se cubren características y ajustes a las que normalmente el
instalador tiene prioridad de acceder, y otras que pueden estar disponibles para el
usuario final (propietario). Estas características se encuentran en el microprocesador
en su punto de acceso del Nivel 1. Nota: Si es preferible, toda la programación se
puede llevar a cabo sin flujo de agua, para dejar que el arranque de la bomba de calor
sea el último paso en le proceso de ajuste y funcionamiento.
1. Suministro de Energía al Controlador:
A. Cuando se suministra energía por primera vez, el controlador hace una
verificación de luces y en la pantalla se visualizará el código de mensaje [888].
Luego de visualizar el código [888], aparecerá brevemente la versión del
programa del microprocesador.
B. Luego el controlador mostrará en la pantalla el valor de la temperatura actual
del agua, siempre y cuando la bomba de circulación esté funcionando y haya
un flujo de agua apropiado circulando a través de la bomba de calor.
C. Si la bomba de circulación de la piscina está apagada, el controlador mostrará
en la pantalla el código de mensaje [FLO]. Este código se indica que hay
insuficiencia o que no hay flujo de agua circulando a través de la bomba de
calor.
2. Explicación de Controles MODE y Arranque de la Bomba de Calor:
A. La bomba de calor se encuentra lista para comenzar a operar, una vez se ha
suministrado la energía a la unidad, hay suficiente flujo de agua circulando, y el
controlador de la bomba de calor ha completado su propia verificación.
B. La bomba de calor es enviada de fábrica con la función del controlador [MODE]
en la posición de apagada (OFF). Hay dos métodos para apagar la bomba de
calor: Primer Método
Segundo Método – El punto de selección del termóstato puede ser disminuido
por debajo del punto de ajuste de la temperatura mínima – 7.2°C (45°F); esta
acción causará que en la pantalla se visualice “OFF”. Para encender la bomba
de calor, primero utilice la tecla MODE para seleccionar el ajuste HEAT
(únicamente en unidades de sólo Calentamiento) o si la unidad es de
Calentamiento y Enfriamiento, utilice la tecla MODE para seleccionar entre:
HEAT (calentar), COOL (enfriar) o ACH (cambio automático).
– una de las funciones de la tecla [MODE] es “OFF”.
(Continúa en la Próxima Página)
20
CONTROLES DE LA BOMBA DE CALOR (continuación)
Arranque y Ajuste de Controles de Operación
Instrucciones del Nivel de Programación del Propietario
(continuación
En el ajuste [OFF], se visualizará la temperatura actual del agua siempre y
cuando la bomba de circulación esté funcionando y haya un flujo de agua
apropiado. En la pantalla del microprocesador se visualizará el código de
mensaje [FLO] (no hay flujo de agua), en el caso que haya insuficiencia o que
no haya flujo de agua circulando a través de la bomba de calor.
C. Utilizando la tecla de FLECHA ARRIBA, incremente el valor de la temperatura
deseada hasta que supere el valor de la temperatura que aparece en la
pantalla. (Nota: En caso de que en la pantalla se visualice “000” luego de
presionar bien sea las teclas de FLECHA ARRIBA o FLECHA ABAJO, vea el
numeral 8, descrito más adelante en esta sección). Una vez se ha
seleccionado la temperatura deseada, la pantalla mostrará la temperatura
actual del agua y la bomba de calor comenzará a operar. Tanto el compresor
como el ventilador deben estar operando antes de que la luz indicadora de
calentamiento (HEATING) se ilumine. (Nota: Cuando la función MODE está
apagada (OFF), en la pantalla se visualizará la temperatura actual, y no habrá
funciones, valores o programación disponibles para hacer ajustes).
3. Apagando la Bomba de Calor:
A. Método 1:
aparezca “OFF” (apagado). La bomba de calor se apagará hasta que la tecla [MODE] sea utilizada para seleccionar un ajuste operacional. Este es el
método preferido para apagar la bomba de calor.
B. Método 2:
temperatura deseada llegue a 7.2°C (45°F) (ajuste mínimo); luego presione una
vez más la tecla de FLECHA ABAJO, para que se visualice “OFF” (apagado)
en la pantalla. Este método es típicamente utilizado en conjunto con
controladores externos de doble alambre; estos controladores vienen
equipados con sus propios termóstatos.
Utilizando la tecla [MODE], presiónela hasta que en la pantalla
Utilizando la tecla de FLECHA ABAJO, presiónela hasta que la
(Continúa en la Próxima Página)
21
CONTROLES DE LA BOMBA DE CALOR (continuación)
Arranque y Ajuste de Controles de Operación
Instrucciones del Nivel de Programación del Propietario
4. Selección de los Ajustes del Termóstato Piscina/Spa:
A. Presione la tecla [POOL / SPA] para escoger entre las temperaturas de ajuste
de la piscina y el spa.
B. La luces indicadoras LED de piscina/spa (pool/spa), las cuales están
localizadas a la izquierda de la visualización de la temperatura, confirmarán al
punto de ajuste seleccionado.
5. Cambio en el Punto de Ajuste de la Temperatura de la Piscina:
A. Utilizando la tecla [POOL / SPA], seleccione el punto de ajuste de la
temperatura del agua de la piscina. La luz indicadora del punto de ajuste de la
piscina confirmará esta selección.
B. El punto de ajuste de la temperatura del agua de la piscina puede variar desde
un mínimo de 7.2°C (45°F) hasta un máximo de 40°C (140°F). El presionar la
tecla de FLECHA ARRIBA aumentará el punto de ajuste un (1) grado por cada
vez que se presione la tecla. El presionar la tecla de FLECHA ABAJO
disminuirá el punto de ajuste un (1) grado por cada presión de la tecla.
(continuación)
6. Cambio en el Punto de Ajuste de la Temperatura del Spa:
A. Utilizando la tecla [POOL / SPA], seleccione el punto de ajuste de la
temperatura del agua del spa. La luz indicadora del punto de ajuste del Spa
confirmará esta selección.
B. El punto de ajuste de la temperatura del agua del spa puede variar desde un
mínimo de 7.2°C (45°F) hasta un máximo de 40°C (140°F). El presionar la
tecla de FLECHA ARRIBA aumentará el punto de ajuste un (1) grado por cada
vez que se presione la tecla. El presionar la tecla de FLECHA ABAJO
disminuirá el punto de ajuste un (1) grado por cada presión de la tecla
(Continúa en la Próxima Página)
22
CONTROLES DE LA BOMBA DE CALOR (continuación)
Arranque y Ajuste de Controles de Operación
Instrucciones del Nivel de Programación del Propietario
7. Selección entre Grados °F (Fahrenheit) y °C (Celsius):
A. Presione y mantenga presionadas simultáneamente las teclas de FLECHA
ARRIBA y FLECHA ABAJO, hasta que el código de mensaje [CF1]
(Celsius/Fahrenheit) se visualice en la pantalla.
B. Con el código de mensaje [CF1] en la pantalla, el presionar las teclas de
FLECHA ARRIBA o FLECHA ABAJO, cambiarán el código de selección bien
sea a “0” ó a “1”. Seleccione “1” para que aparezca la temperatura en
Fahrenheit, o “0” para que aparezca la temperatura en Celsius. Una vez se
haya seleccionado la unidad de temperatura, el no
15 segundos le permitirá al microprocesador del controlador memorizar dicha
selección y regresar de nuevo al modo de operación normal. También el
presionar la tecla [POOL / SPA] permitirá memorizar la selección y luego
avanzar al próximo parámetro de del menú: [ULC] (Código de Bloqueo del
Usuario).
8. Opción del Código de Bloqueo del Usuario [ULC]:
Explicación de la Opción:
presionar cualquier tecla por
(continuación)
Las bombas de calor son enviadas desde la fábrica con la opción del código de
bloqueo del usuario inhabilitado. En el momento en que el propietario de la bomba
de calor active la opción de bloqueo [ULC], estará restringiendo el acceso a los
controles de la unidad. No es posible realizar cambios en el nivel 1 de la
programación (alterar el ajuste de la temperatura, selección piscina / spa, grados
Celsius o Fahrenheit, etc.) si está activada la opción [ULC] y se ha ingresado el
código ULC incorrecto. Se puede pensar en la opción [ULC] como si fuera una
cubierta de bloqueo electrónica para los controles.
A. Selección de la Opción ULC:
1) Presione bien sea la tecla de FLECHA ARRIBA o FLECHA ABAJO, si en la
pantalla aparece momentáneamente el código de mensaje “LOC”, seguido
por el número “0”, la opción [ULC] es activada. Si aparece “0” en la
pantalla proceda al numeral “6)” de esta sección; de lo contrario proceda
con el numeral “2)” a continuación.
2) Presione y mantenga presionadas simultáneamente las teclas de FLECHA
ARRIBA y FLECHA ABAJO, hasta que en la pantalla se visualice el código
de mensaje [CF1] (Celsius / Fahrenheit).
(Continúa en la Próxima Página)
23
CONTROLES DE LA BOMBA DE CALOR (continuación)
Arranque y Ajuste de Controles de Operación
Instrucciones del Nivel de Programación del Propietario
Opción del Código de Bloqueo del Usuario [ULC] (continuación):
3) Presione una vez la tecla [POOL / SPA] para visualizar en la pantalla el código de mensaje [ULC].
4) Con el código de mensaje [ULC] en la pantalla, presione bien sea la tecla
de FLECHA ARRIBA o FLECHA ABAJO, y aparecerá el número “1” o el “0”.
Si se selecciona el “0”. Se permitirá que el teclado permanezca sin
bloqueos. Si selecciona el “1” le permitirá al propietario el utilizar la opción
de código de bloqueo. Luego para ingresar el número del código de
bloqueo, presione una vez la tecla [POOL / SPA] para que aparezca en la
pantalla el código de mensaje [ELC] (entrada de código de bloqueo).
5) Con el código de mensaje [ELC] en la pantalla, utilice las teclas de
FLECHA ARRIBA o FLECHA ABAJO, para seleccionar un código de
bloqueo. Este código puede ser cualquier número desde “00” hasta “99”.
El código de bloqueo preseleccionado por la fábrica es “0”. El no
cualquier tecla por un período de tiempo de 15 segundos, le permitirá al
controlador memorizar la selección y retornar al modo de operación normal.
El presionar la tecla [POOL / SPA] también memorizará la selección, y le
permitirá al controlador avanzar hacia el siguiente parámetro del menú:
[CFO] (Opciones de Call-Flex).
(continuación)
presionar
6) Una vez se ha habilitado la opción [ULC], al presionar cualquier tecla se
visualizará en la pantalla el código de mensaje “LOC”, seguido por el
número “0” (requiriendo por la entrada del número correcto del código de
bloqueo). Para lograr acceso al controlador:
a. Utilizando la tecla de FLECHA ARRIBA, busque el número correcto del
código de bloqueo.
b. Luego presione la tecla [POOL / SPA], y se visualizará en la pantalla la
temperatura actual del agua. En este momento se pueden ver los
ajustes del controlador o hacer cambios a éstos si así se desea.
c. Luego de un período de tiempo de aproximadamente cuatro (4) minutos,
durante el cual no se haya presionado ninguna tecla, el controlador
retornará automáticamente al modo de bloqueo. Si de hecho la
selección de [ULC] ha sido ajustada en “1”, el controlador siempre
quedará seguro en el modo de bloqueo.
(Continúa en la Próxima Página)
24
CONTROLES DE LA BOMBA DE CALOR (continuación)
Arranque y Ajuste de Controles de Operación
Instrucciones del Nivel de Programación del Propietario
Opción del Código de Bloqueo del Usuario [ULC] (continuación):
d. Con la opción [ULC] habilitada, no
controlador, sino se tiene conocimiento del número correcto del código
de bloqueo. Asegúrese de guardar el número del código de bloqueo en un lugar seguro. El número del código de bloqueo puede ser
cambiado cualquier cantidad de veces, siguiendo las instrucciones que
se han detallado en esta sección
B. Desactivación de la Opción del Código de Bloqueo del Usuario [ULC
1) Siguiendo las instrucciones detalladas previamente en los numerales “8) y
6)”, presione cualquier tecla para ingresar el número del código de bloqueo
del usuario, y luego presione la tecla [POOL / SPA].
2) Inmediatamente después de haber ingresado el número del código de
bloqueo del usuario, presione y mantenga presionadas simultáneamente las
teclas de FLECHA ARRIBA y FLECHA ABAJO, hasta que se visualice en la
pantalla el código de mensaje [CF1].
se podrán hacer ajustes en el
(continuación)
]:
3) Luego utilice la tecla de [POOL / SPA] para avanzar hasta que aparezca en
la pantalla el código de mensaje [ULC]. Presione la tecla de FLECHA
ABAJO para que aparezca en la pantalla el número “0”. Esto desactivará la
función de bloqueo del usuario.
C. El Código de Bloqueo del Usuario Está Activado – Se Desconoce el
Número de Acceso (“Entrada por la Parte Posterior”):
Nota: Se debe llevar a cabo el siguiente procedimiento para lograr acceso a la
programación del controlador, en caso de que la opción del código de bloqueo
del usuario [ULC] esté activada, y que haya programado un número de bloqueo
diferente al de la fábrica (“0”) y que además de desconozca:
1) Presione y mantenga presionadas simultáneamente las teclas de [POOL /
SPA] y de FLECHA ARRIBA, hasta que se visualice en la pantalla el código
“888”. Esta operación restaurará el controlador a los ajustes y selecciones
originales de fábrica.
(Continúa en la Próxima Página)
25
CONTROLES DE LA BOMBA DE CALOR (continuación)
Arranque y Ajuste de Controles de Operación
Instrucciones del Nivel de Programación del Propietario
Opción del Código de Bloqueo del Usuario [ULC] (continuación):
El Código de Bloqueo del Usuario Está Activado – Se Desconoce el
Número de Acceso (“Entrada por la Parte Posterior”) (continuación):
2) Una vez restaurados los ajustes según la fábrica, el código de bloqueo del usuario [ULC] es desactivado y el número de código de bloqueo del usuario
[ELC] se restablece en “0”.
3) Adicionalmentetodos los demás ajustes y selecciones son
restablecidos según los originales programados por la fábrica. Si se
tiene instalado un controlador externo debe contactar al Grupo de Servicio
Técnico de AquaCal en el número telefónico 727-823-5642 o para
asistencia en Español a HornerXpress Worldwide en el (954) 938-5355.
(continuación)
(Continúa en la Próxima Página)
26
CONTROLES DE LA BOMBA DE CALOR (continuación)
Arranque y Ajuste de Controles de Operación
Instrucciones del Nivel de Programación del Propietario
9. Selección de las Opciones Call-Flex [CFO]:
Información General:
La opción Call-Flex ajusta automáticamente el tiempo de operación de la bomba
de circulación y de la bomba de calor, basado en los cambios de las condiciones
del clima. A medida que las condiciones del tiempo avanzan progresivamente a
temperaturas más frías durante los meses de invierno o cuando hay oleadas de
clima frío, al no tener la opción Call-Flex es necesario el hacer ajustes manuales al
tiempo de operación de la bomba de circulación para permitir que la bomba de
calor mantenga o renueve la temperatura deseada del agua (para que la bomba
de calor opere, debe estar funcionando la bomba de circulación). De igual forma si
no se tiene la opción de Call-Flex, se debe recordar el restablecer los controles de
la bomba de circulación luego de los eventos de temperaturas frías. La opción de
Call-Flex reduce considerablemente la necesidad de hacer ajustes manuales a los
tiempos de operación de la bomba de circulación debido a las influencias
climáticas.Call-Flex es una opción instalada por el distribuidor y que noviene instalada con cada bomba de calor. Si usted no está seguro verifique con
su distribuidor para determinar si el equipo de Call-Flex hace parte de la
instalación original. Si el equipo de Call-Flex no hace parte de la instalación
original y usted quisiera instalarlo en su bomba de calor, por favor contacte a su
distribuidor más cercano para que éste le provea la instalación del equipo.
(continuación)
Si la instalación viene equipada con la opción Call-Flex, lleve acabo las siguientes
instrucciones para controlar las características de Call-Flex:
A. Presione y mantenga presionadas simultáneamente las teclas de FLECHA
ARRIBA y FLECHA ABAJO, hasta que se visualice en la pantalla el código de
mensaje [CF1]. Presione tres veces la tecla [POOL / SPA] para avanzar en la
pantalla hasta que aparezca el código de mensaje [CF0] (Opciones Call-Flex).
B. Con el código de mensaje [CF0] (Opciones Call-Flex) en la pantalla, presione
las teclas de FLECHA ARRIBA o FLECHA ABAJO para seleccionar “0” para
desactivar las opciones de Call-Flex; “1” para activar la opción Call, y “2” para
activar la opción Flex. El no
de 15 segundos, le permitirá al controlador memorizar la selección y retornar al
modo de operación normal. El presionar la tecla [POOL / SPA] también
memorizará la selección, y le permitirá al controlador avanzar hacia el siguiente
parámetro del menú: [LOC] (Código de Servicio de Bloqueo).
C. Para información adicional por favor refiérase a las instrucciones de instalación
del equipo Call-Flex, incluídas en el mismo. Para copias adicionales contacte a
HornerXpress Worldwide en el (954) 938-5355 para asistencia en Español.
presionar cualquier tecla por un período de tiempo
27
MANTENIMIENTO Y RECOMENDACIONES DE
OPERACIÓN
La información de esta sección está dirigida principalmente para el propietario,
pero también puede ser utilizada por distribuidores, personal de mantenimiento y
servicio de aire acondicionado. Esta sección contiene información concerniente al
mantenimiento preventivo (planeado), flujo apropiado de agua, mantenimiento de
las distancias apropiadas, e importante información adicional. Por favor lea
detenidamente esta sección y antes de llamar al Departamento de Asistencia al
Cliente de AquaCal en el número telefónico 727-823-5642 o para asistencia en
Español a HornerXpress Worldwide en el (954) 938-5355.
Mantenimiento General
Las bombas de calor deben ser inspeccionadas y mantenidas cada año por un
especialista en bombas de calor. Adicionalmente si la bomba de calor está
localizada cerca de la playa o área costera donde la sal y la arena se convierten
en un factor perjudicial, será necesario realizar servicios de mantenimiento más
frecuentes. Para información del planeamiento de servicio por favor refiérase a la
sección Programa de Mantenimiento Planeado
Si tiene inquietudes adicionales por favor contacte el Departamento de Asistencia
al Cliente de AquaCal en el número telefónico 727-823-5642 o para asistencia en
Español a HornerXpress Worldwide en el (954) 938-5355.
la cual se describe más adelante.
Se le recomienda llevar a cabo el mantenimiento anual para tener vigente la
garantía de la unidad. Si usted decide no
Mantenimiento Planeado, es necesario que usted lave con agua regularmente el
evaporador (radiador) y que mantenga libre de hojas y basura la base de la unidad.
Si usted como propietario decide lavar el evaporador o llevar acabo otro cuidado
cosmético de la bomba de calor, solicite el documento llamado: “Cuidado de la
Apariencia de las Bombas de Calor: Método Aprobado para Propietarios.” Por
favor contacte el Departamento de Asistencia al Cliente de AquaCal en el número
telefónico 727-823-5642 o para asistencia en Español a HornerXpress Worldwide
en el (954) 938-5355.
participar en el Programa de
(Continúa en la Próxima Página)
28
MANTENIMIENTO Y OPERACION (continuación)
Seguridad Durante Operaciones de Limpieza
El no hacer caso a lo siguiente puede
¡ADVERTENCIA!
RIESGO DE CHOQUE ELECTRICO… Si usted decide lavar la bomba de calor por
medio de una manguera con agua desconecte toda la energía que alimenta todos
los equipos de la piscina, incluyendo la bomba de calor, la bomba de circulación y
cualquier otro equipo eléctrico. NO esparza el agua directamente a los
componentes eléctricos. NO
haya secado completamente.
restablezca la energía eléctrica hasta que el agua se
¡PRECAUCION!
NO utilice una lavadora a presión para lavar la bomba de calor. Pueden resultar
daños en las aletas del evaporador (radiador), u otros componentes.
causarle heridas permanentes o la
muerte
El no hacer caso a lo siguiente puede
causarle daños al equipo.
Manteniendo el Flujo de Agua Apropiado
x Es importante operar y mantener el filtro de acuerdo a las especificaciones del
fabricante. A medida que el filtro comienza a ensuciarse, el flujo de agua que pasa
a través de la bomba de calor es cada vez menor. Entre más alta sea la presión
en el manómetro del filtro menor será el flujo de agua.
x De igual formar que un filtro sucio, grandes cantidades de basura en las canastillas
de la bomba y el desnatador pueden también reducir el flujo de agua. Mantenga la
canastillas libre de basuras.
x Verifique que las válvulas estén bien dispuestas. Una válvula parcialmente
cerrada después del filtro o una válvula de sobrepaso alrededor de la bomba de
calor que esté totalmente abierta, pueden causar que haya insuficiente flujo de
agua pasando a través de la bomba de calor.
x Si las condiciones mencionadas anteriormente se mantienen sin resolver, el flujo
del agua que pasa a través de la bomba de calor se reducirá hasta el punto que
los dispositivos internos de seguridad (“HP” o “HP5”) apaguen la bomba de calor.
x Antes de llamar por ayuda para servicio, siempre verifique que el filtro este limpio,
al igual que la canastillas de la bomba y desnatador y que las posiciones de las
válvulas sean las correctas. Si el problema persiste por favor llame al
Departamento de Asistencia al Cliente de AquaCal al número 727-823-5642 o para
asistencia en Español a HornerXpress Worldwide en el (954) 938-8857.
29
MANTENIMIENTO Y OPERACION (continuación)
Control de la Química del Agua
x ¡IMPORTANTE! Todas las bombas de calor de AquaCal están diseñadas y
fabricadas para una excepcional durabilidad y confiabilidad. El intercambiador de
calor en titanio con el que viene equipado este modelo, lo hace prácticamente
impenetrable a los daños que se puedan causar por la falta de balance en la
química del agua. Sin embargo otros componentes de la unidad y los demás
equipos de la piscina y spa pueden estar sujetos a daños por exposición
prolongada a una agua químicamente balanceada inapropiadamente. De la
misma forma los bañistas pueden estar expuestos a riesgos de salud si el balance
químico del agua no se mantiene apropiadamente.
x Para lograr un mayor tiempo de vida en toda la instalación de la piscina / spa y
para la seguridad de los bañistas, el altamente recomendable verificar
regularmente el balance químico del agua y asegurarse de mantenerlo dentro de
las normas apropiadas. Por favor refiérase a la siguiente tabla para identificar los
niveles apropiados para el balance químico del agua.
VALORES RECOMENDADOS PARA EL BALANCE QUIMICO DEL AGUA
Parámetro Piscina Spa
Cloro
Bromo
pH
Alcalinidad Total
Dureza de Calcio
Sólidos Totales Disueltos
1.0 – 3.0 ppm 1.5 – 3.0 ppm
2.0 – 4.0 ppm 3.0 – 5.0 ppm
7.4 – 7.6 ppm 7.2 – 7.8 ppm
80 – 140 ppm 80 – 120 ppm
200 – 400 ppm 200 – 400 ppm
1,000 – 2,000 ppm 1,500 ppm y por encima
PRECAUCION – Operaciones de Recubrimientos en la Piscina / Spa
La bomba de calor debe permanecer apagada mientras se estén llevando a cabo
trabajos en el recubrimiento o haciendo limpiezas con ácido. El flujo del agua para la
bomba de calor se debe mantener cerrado hasta que se logre de nuevo un nivel
químico del agua apropiadamente balanceado y que el agua tenga una apariencia
clara. El no seguir estas instrucciones puede anular la garantía de la bomba de calor.
30
MANTENIMIENTO Y OPERACION (continuación)
Control de Aguas de Riegos y Escorrentías por Tormentas
x Control de Riegos: En regiones donde se utiliza el agua de pozo para irrigación,
algunas veces la calidad del agua es pobre, y el rociar la unidad con ésta agua
puede dañar algunos de sus componentes. Es importante siempre mantener los
aspersores de riego retirados de la bomba de calor sin importar la calidad del agua.
x Evite que caigan fuertes derrames y escorrentías de aguas lluvias dentro de la
unidad. La bomba de calor está diseñada para soportar aguas lluvias normales,
pero derrames fuertes de agua provenientes de los techos pueden eventualmente
dañar componentes dentro de la bomba de calor.
x Si la bomba de calor se encuentra instalada directamente debajo del borde de un
techo o alero, será necesario instalar un desagüe, canales de techo o protector
contra la lluvia con el fin de promover el tiempo de vida de la bomba de calor.
Conservar Espacios Libres Alrededor de la Bomba de Calor
x Para una máxima eficiencia de la bomba de calor, se deben mantener los espacios
libres apropiados para que el aire circule libremente.
x Es muy importante mantener el área adyacente a la bomba de calor libre de
plantas, arbustos, muebles de jardín, contenedores con químicos, etc. Estos
pueden evitar que el aire fluya completamente a través de la bomba de calor,
generando una operación ineficiente o un posible daño en la unidad.
x Adicionalmente no coloque ningún tipo de objeto encima de la bomba de calor. Si
lo hace está bloqueando la salida del aire de la unidad y puede generar un daño al
compresor o al motor del ventilador.
x Las distancias en los espacios libres también son necesarias para poder acceder a
las partes en funcionamiento de la bomba de calor. Una unidad que tenga un “fácil
acceso”, será una unidad a la cual se le pueda hacer un fácil mantenimiento. El
personal de servicio y mantenimiento le agradecerán el mantener libre de
obstáculos el área alrededor de la bomba de calor.
x En la siguiente página se ilustran los diagramas con los requerimientos específicos
de los espacios libres.
(Continúa en la Próxima Página)
31
MANTENIMIENTO Y OPERACION (continuación)
Manteniendo Espacios Libres Alrededor de la Bomba de Calor (continuación)
16 Cm.
Modelos SQ: 32 Cm.
(Posterior)
77 Cm.
(Frontal)
31 Cm.
(Lateral
)
Torrentes de
Aguas Lluvias
deben ser
Dirigidos Fuera
de la Unidad
77 Cm.
Libres (mínimo)
Vista Lateral (No a Escala)
Alero con
Canaleta
1.53 M.
Libres (mínimo)
16 Cm.
Modelos SQ: 32 Cm.
(Posterior)
31 Cm.
(Lateral)
Vista Superior (No a Escala)
Consejos Para el Calentamiento
Calentamiento en Climas Fríos:
Los momentos de menor eficiencia
en la noche o muy temprano en la madrugada por ser los momentos más fríos. Para
una mayor eficiencia la bomba de calor debe ser operada durante los momentos más
calurosos del día. De forma inversa, si se quiere enfriar la piscina, lo mejor es operar
la bomba de calor en la noche. Asegúrese de programar la bomba de circulación y la
bomba de calor de acuerdo a éstos parámetros
para la operación de la bomba de calor son tarde
Cobertores para Piscina / Spa:
Una cubierta “solar” reduce significativamente sus costos por calentamiento. Verifique
con su distribuidor si su bomba de calor fue especificada para trabajar en conjunto
con una cubierta. Las piscinas con cubierta normalmente pierden entre 1.7°C y 2.2°C
de calor cada noche, mientras una piscina sin cubierta pierde entre 4.4°C y 5.6°C de
calor. Al utilizar una cubierta se pueden lograr reducciones entre un 40 y un 60% en
los costos por calentamiento. (Idea: Para conocer más sobre innovaciones en
cubiertas líquidas contacte el Departamento de Asistencia al Cliente de AquaCal en el
número 727-823-5642 o para asistencia en Español a HornerXpress Worldwide en el
(954) 938-5355).
El no hacer caso a lo siguiente puede
¡ADVERTENCIA!
causarle heridas permanentes o la muerte
El uso inapropiado de las cubiertas de piscina / spa pueden ser un riesgo de
ahogamiento para personas y mascotas. Las cubiertas solares NO son cubiertas
de seguridad. No están diseñadas para soportar el peso de una persona o
mascota. Nunca ingrese a la piscina hasta que se haya retirado completamente la
cubierta (bajo ninguna circunstancia se debe nadar por debajo de la cubierta).
32
MANTENIMIENTO Y OPERACION (continuación)
Consejos Para el Calentamiento (continuación)
Calentamiento de Combinación de Piscina y Spa:
Todo los que se ha mencionado para la piscina también aplica para el calentamiento
del spa – la diferencia está en la cantidad de agua que se está calentando. Todas las
bombas de calor de AquaCal vienen equipadas con dos termóstatos. Uno de ellos es
para la piscina y el otro para el spa. Simplemente posicione las válvulas de
aislamiento de la piscina y el spa tal y como lo indica el instalador. Seleccione el
termóstato apropiado (piscina / spa) dependiendo del cuerpo de agua que quiera
calentar, y con el suministro de energía y el flujo de agua apropiado a la bomba de
calor, la temperatura del agua se mantendrá en la temperatura seleccionada.
Su sistema puede ser automatizado con la instalación de la opción del Equipo de
Interruptor de Flujo Externo (Número de Parte 0040S). El utilizar esta opción le
evitará a usted el tener que cambiar el termóstato cada vez que usted quiera cambiar
de piscina al spa y de nuevo a la piscina. O instalar el Controlador Universal de
Bomba de Calor de AquaCal (Número de parte 0097TS) y no solamente obtenga el
cambio automático del termóstato, además la operación automática de las válvulas de
la piscina y el spa. Para detalles de estas opciones contacte a su distribuidor o al
Departamento de Asistencia al Cliente de AquaCal en el número telefónico 727-8235642 o para asistencia en Español a HornerXpress Worldwide en el (954) 938-5355).
Calentamiento del Spa y Opción de Soporte del Spa:
El aire circulando en su spa, mientras éste está siendo calentado por la bomba de
calor, muy a menudo neutralizará o parcialmente contrarrestará el calor que está
siendo transferido por la bomba de calor al spa. Esta pérdida de calor adicional se
equipara a un incremento de tiempo para calentar el spa a la temperatura deseada.
Cuando este calentando el spa asegúrese de apagar el soplador de aire. También
durante el calentamiento se debe eliminar el aire que se esté inyectando a través de
los chorros.
Si usted está utilizando la bomba de calor para calentar únicamente el spa, el
termóstato de la piscina (POOL) puede ser utilizado como un control de soporte:
simplemente seleccione el control de la piscina en un punto entre 6°C y 8°C por
debajo de la temperatura deseada para el spa y seleccione el termóstato de la
piscina. Este método le permite al spa cuando no está en uso ser mantenido a una
temperatura caliente pero algo menor que la temperatura normal de uso. Es
recomendable utilizar una cubierta para spa si se está utilizando esta opción de
soporte. El utilizar esta opción de soporte tiene como resultado la reducción de
tiempos de calentamiento comparado con el arranque de calentamiento desde frío.
33
MANTENIMIENTO Y OPERACION (continuación)
Calculando el Tiempo de Calentamiento Inicial
El tiempo que se toma inicialmente en calentar su piscina o spa depende de varios
factores.
Primero, determine cuantos galones de agua son los que se van a calentar.
Conociendo esto, luego usted puede calcular el equivalente de agua en libras, y los
BTU necesarios para calentar el volumen de agua a la temperatura deseada.
A continuación determine la producción aproximada de BTU de la bomba de calor a la
temperatura actual del medio ambiente; puede encontrar literatura del producto en
www.aquacal.com
el número telefónico 727-823-5642 o para asistencia en Español a HornerXpress
Worldwide en el (954) 938-5355). Finalmente decida a que temperatura desea
mantener su piscina o spa.
La siguiente hoja de trabajo puede ser utilizada para calcular aproximadamente
cuánto tiempo le tomará a su bomba de calor calentar el agua de la piscina o spa a la
temperatura escogida. Tenga en cuenta que el tiempo de calentamiento puede variar
debido a condiciones climáticas que se presenten mientras la bomba de calor esté en
operación. El uso de una cubierta solar puede dramáticamente aumentar la rapidez
del calentamiento y el mantener caliente la piscina.
o contacte al Departamento de Asistencia al Cliente de AquaCal en
Volumen de la Piscina (Longitud x Ancho x Profundidad Promedia) = _________ Pies Cúbicos
X Galones por pie cúbico (7.5) = ___________ Galones de la Piscina
X Libras por Galón (8.3) = ____________ Libras de Agua
¿Cuántos grados quiere aumentar la temperatura del agua de la piscina?
# de Grados ________ X Libras de Agua (según lo anterior) = ___________ BTU Requeridos
BTU Requeridos ______X BTU Producidos (bomba de calor) = ________ Horas de Operación
Factor de Ajuste Opcional para Climas Fríos
Horas de Operación (según lo anterior) ___ X 1.25 (15.6°C Factor de Temperatura Externa) =
_________ Horas de Operación a 15.6°C
34
MANTENIMIENTO Y OPERACION (continuación)
Arranque: Requerimiento de Operación Continua de la Bomba de
Circulación
Cuando se opera una bomba de calor por primera vez, se debe permitir que opere
continuamente hasta que se alcance la temperatura deseada en el agua de la piscina.
Esto puede tomar desde varias horas hasta varios días, dependiendo del tamaño de
la piscina o el spa y de las condiciones del clima.
Si un temporizador o un dispositivo similar controlan los tiempos de operación de la
bomba de circulación, será necesario invalidar temporalmente el temporizador o
controlador, para permitir que la bomba de circulación opere por un período de 24
horas continuas.
Una vez el agua bien sea de la piscina o el spa haya alcanzado la temperatura
deseada, se puede restablecer el temporizador o controlador de la bomba de
circulación.
Utilización en las Estaciones y Cierre
Durante la Temporada de Nado:
x Durante la temporada de nado, aún sin estar utilizando la piscina o el spa, permita
que el agua fluya a través de la bomba de calor. El hacer esto le evita la
necesidad de reposicionar las válvulas cuando quiera calentar de nuevo la piscina
o el spa.
x Durante los períodos cuando no se desee ni calentar ni enfriar, mantenga siempre
los controles de la bomba de calor en la posición de apagado (OFF).
¡Importante!
La Siguiente Información es Crítica para la
Supervivencia de Su Bomba de Calor
Protección contra el Congelamiento y Cierre Extendido:
En zonas donde las condiciones de congelamiento raramente ocurren, permita que la
bomba de circulación opere continuamente mientras esté presente el período de
congelamiento. Típicamente durante condiciones de un ligero congelamiento, el
circular el agua evitará que ésta se congele.
En zonas donde las condiciones de congelamiento prevalecen y se mantienen, la
bomba de calor tiene
siguientes instrucciones para preparar su bomba de calor para el invierno.
que ser preparada para el invierno. Por favor refiérase a las
(Continúa en la Próxima Página)
35
MANTENIMIENTO Y OPERACION (continuación)
Utilización en las Estaciones y Cierre (continuación)
Cierre en la Temporada de Invierno – Fuertes Condiciones de Congelamiento:
El no hacer caso a lo siguiente puede
¡PRECAUCION!
El no preparar adecuadamente la bomba de calor para la temporada de invierno
puede causar serios daños a la bomba de calor. Daños por congelamiento NO
están cubiertos bajo la garantía de la bomba de calor.
¡PRECAUCION!
Mientras que las conexiones de la plomería estén preparadas para la temporada de
invierno (no apretadas completamente), es imperativo que no circule
piscina / spa a través de la bomba de calor. La pérdida de agua a través de las
conexiones de plomería flojas, puede generar daños en la bomba de circulación de
agua, en la estructura de la piscina / spa y en otros equipos.
causarle daños al equipo.
El no hacer caso a lo siguiente puede
causarle daños al equipo.
agua de la
Procedimiento para la Preparación de la Temporada de Invierno:
1. Desconecte todo el suministro de energía eléctrica que alimente la bomba de calor.
Apague la bomba de circulación.
2. Desconecte las dos (2) uniones de plomería que van a la bomba de calor.
3. Localice y remueva el tapón manual de drenaje, el cual se encuentra en la parte
inferior frontal de la bomba de calor (ver figura en la siguiente página). (La posición
del tapón de drenaje puede variar según el modelo de la bomba de calor).
4. Permita que salga toda el agua que está en el intercambiador y luego vuelva a
colocar el tapón de drenaje. Rosque el tapón en el sentido de las manecillas del
reloj hasta que ajuste, y luego aplique 1/8 más de vuelta.
5. Para prevenir que los insectos y otros animales entren por la plomería de la bomba
de calor durante la temporada de invierno, vuelva a conectar parcialmente las dos
(2) uniones de conexión. Rosque las uniones una o dos vueltas para permitir que
la condensación se pueda drenar y así evitar que ingresen insectos o animales al
circuito de plomería.
6. Próxima Estación:
vuelva a roscar y apretar las conexiones de plomería, por lo general es suficiente
solo con fuerza de la mano, y de nuevo restablezca el suministro de energía.
Para tener lista la bomba de calor para su uso, simplemente
(Continúa en la Próxima Página)
36
MANTENIMIENTO Y OPERACION (continuación)
Utilización en las Estaciones y Cierre (continuación)
Procedimiento para la Preparación de la Temporada de Invierno (continuación):
LOCALIZACION DEL TAPON DE DRENAJE
La Localización Exacta del
Tapón de Drenaje Varía
por Modelo.
Tapón de
Drenaje
El no hacer caso a lo siguiente puede
¡PRECAUCION!
Mientras las conexiones de plomería están en la condición de preparación para el
invierno (no apretadas completamente), es imperativo el no circular agua a través
de la bomba de calor. La pérdida de agua a través de las conexiones de plomería
sueltas, pueden crear daños en la bomba de circulación, en la estructura de la
piscina/spa y daños a otros equipos.
causarle daños al equipo.
37
MANTENIMIENTO Y OPERACION (continuación)
Programa de Mantenimiento Planeado
Las bombas de calor de AquaCal deben ser inspeccionadas y mantenidas cada año
para asegurar las máximas eficiencias de operación y además proteger su inversión.
Este mantenimiento e inspección, potencialmente le pueden extender el tiempo de
vida útil de su bomba de calor muy por encima del período de cobertura de la garantía.
Nuestros técnicos de amplia experiencia y entrenados por la fábrica le ofrecen unos
procedimientos de mantenimiento muy completos, los cuales están diseñados para
que su bomba de calor opere eficientemente y sin problemas por muchos años
continuos.
Los Siguientes son los 20 Puntos del Programa de Mantenimiento Planeado:
9Verifique el Flujo de Agua
9Limpie el Evaporador
9Verifique los Contactos del Relé
9Verifique los Valores del Capacitor
9Verifique los Niveles del Gas Refrigerante
9Limpie la Cubierta de la Bomba de Calor
9Verifique los Espacios Libres de las Aspas del Ventilador
9Verifique el Interruptor de Flujo /Presión
9Verifique las Conexiones Eléctricas
9Verifique que la Unidad tenga el Voltaje Apropiado
9Lubrique el Motor del Ventilador (si se aplica)
9Verifique el Amperaje del Motor del Ventilador
9Verifique el Balance Químico en el Agua de la Piscina y el Spa
9Verifique y Limpie los Drenajes para Condensación
9Verifique el Amperaje del Compresor
9Verifique el Amperaje de la Bomba de Circulación
9Verifique las Posiciones de las Válvulas de Plomería
9Verifique el Cambio en la Temperatura del Aire a través del Evaporador
9Verifique los Controles de Operación y los Sensores de Temperatura
9Verifique el Cambio de Temperatura del Agua a través del Intercambiador de Calor
Recomendamos que el Mantenimiento Preventivo se debe llevar a cabo al año de
haber instalado la bomba de calor.
38
DETERMINACION Y SOLUCION DE
PROBLEMAS
La Bomba de Calor No Opera…
¿Está Iluminada la Pantalla?
Asegúrese que el corta circuitos principal (localizado en el tablero de suministro de
energía) y el interruptor de desconexión estén ambos en la posición de encendido
(ON).
¿Aparece en la Pantalla el Código de Mensaje “FLO”?
Si es así, verifique y asegúrese que la bomba de circulación esté funcionando y
que el filtro esté limpio. Puede haber una válvula colocada en posición incorrecta
permitiendo que el flujo de agua sobrepase la bomba de calor. Asegúrese de que
le agua esté fluyendo a través de la bomba de calor.
¿Está el termóstato de la Piscina o el Spa seleccionado para calentar el cuerpo
de agua indicado, y ha intentado usted seleccionar un ajuste de temperatura
superior?
Si no es así, la temperatura actual del agua puede estar por encima de la del
termóstato seleccionado. Eleve la temperatura deseada por encima de la lectura
de la temperatura actual. La bomba de calor debe arrancar luego de un período
de cuatro (4) minutos y las luz “Heating” se debe encender. Si la bomba de calor
no arranca, y ésta no se encuentra en el modo de descongelación (código de
mensaje “FS”), contacte a su distribuidor más cercano o al Departamento de
Asistencia al Cliente de AquaCal en el número 727-823-5642 o para asistencia en
Español a HornerXpress Worldwide en el (954) 938-5355).
La Bomba de Calor Funciona, Pero No Calienta…
¿Es el aire que sale por encima de la unidad notablemente más frío que el aire
del medio ambiente circundante?
La diferencia de temperatura típica es entre 5°C y 7°C. Primero asegúrese de que
todas las superficies del evaporador están libres de obstrucciones y obstáculos,
como techos bajos, arbustos, plantas, paredes, cercas, etc., los cuales pueden
estar impidiendo el flujo libre de aire. La bomba de calor requiere de un buen flujo
de aire para funcionar a su mayor eficiencia. Si no es así, contacte a su
distribuidor más cercano o al Departamento de Asistencia al Cliente de AquaCal
en el número 727-823-5642 o para asistencia en Español a HornerXpress
Worldwide en el (954) 938-5355).
¿Cuántas horas por día está operando la bomba de circulación?
Condiciones de climas más fríos, o el calentar el agua a una temperatura por
encima de lo normal, requerirá el operar la bomba de calor por un período de
tiempo mayor. ¿Fue la bomba de calor especificada para operar con una manta o
cobertor? (verifique con su distribuidor). Un cobertor puede ser de gran utilidad
para disminuir los períodos de operación de calentamiento y al mismo tiempo
generar grandes ahorros en los costos de energía por calentamiento.
39
DETERMINACION Y SOLUCION DE PROBLEMAS
(continuación)
La Bomba de Calor Funciona Pero No Calienta (continuación)
¿Cuál es la temperatura del medio ambiente?
La bomba de calor puede estar en el modo de descongelación si la temperatura
del aire disminuye por debajo de 10°C. En la pantalla se visualizará el código de
mensaje “FS” si la bomba de calor está en el modo de descongelación. Si la
temperatura del medio ambiente no está fría, pero aún aparece en la pantalla el
código de mensaje “FS”, por favor contacte a su distribuidor más cercano o al
Departamento de Asistencia al Cliente de AquaCal en el número 727-823-5642 o
para asistencia en Español a HornerXpress Worldwide en el (954) 938-5355).
Agua Saliendo de la Bomba de Calor…
¿Es una fuga de agua o simplemente condensación por la operación normal?
Lo siguiente le enseña a determinarlo
Apague la bomba de calor manteniendo en funcionamiento la bomba de
circulación. En unas pocas horas deberá haber una considerable reducción en la
cantidad de agua presente alrededor de la base de la bomba de calor. Si
aparentemente el agua se estuviera secando, entonces se determina que el agua
proviene de la condensación, y lo cual indica que la bomba de calor está operando
normalmente.
Como otra alternativa para determinar si hay o no una fuga en la bomba de calor,
verifique si en el agua que se esté drenando hay presencia del mismo elemento
purificador utilizado en la piscina o el spa. Utilice el equipo o una tirilla de pruebas
para verificar si hay presencia de cloro o bromo en el agua. Si la prueba de agua
tiene un resultado positivo, por favor contacte a su distribuidor más cercano o al
Departamento de Asistencia al Cliente de AquaCal en el número 727-823-5642 o
para asistencia en Español a HornerXpress Worldwide en el (954) 938-5355). Si
la prueba es negativa, muy seguramente el agua es resultado de una
condensación inofensiva.
NOTA:Si se tiene instalado y operando un ionizador o un generador de ozono
como medio de purificación del agua de la piscina o el spa, el método de
prueba química para determinar las fugas de agua no tendrá efectividad.
PRECAUCION: Si la prueba química indica que hay presencia de una fuga de agua
apague inmediatamente la bomba de circulación de la piscina y
contacte a su distribuidor o instalador autorizado o el Departamento
de Asistencia al Cliente de AquaCal en el número 727-823-5642 o
para asistencia en Español a HornerXpress Worldwide en el (954)
938-5355.
40
DETERMINACION Y SOLUCION DE PROBLEMAS
DIAGRAMA DE FLUJO
La Bomba de Calor no Opera
ARRANQUE
¿Está Iluminada la Pantalla?
La pantalla está iluminada.
Si se ve “FLO” en la pantalla Si no, asegúrese que el
verifique que la bomba de corta circuitos principal
circulación esté operando y (localizado en el tablero de
que el filtro esté limpio. Suministro de energía) y el
Puede haber una válvula en interruptor de desconexión
la posición incorrecta. Estén ambos en la posición
Asegúrese de que el agua de encendido (ON).
esté fluyendo a través de la
bomba de calor.
SiNo
¿Está la Bomba de
Calor Operando
Correctamente?
¿Está el termóstato de la
agua indicado, y ha intentado
usted seleccionar un ajuste
de temperatura superior?
¿Está la Bomba de
Calor Operando
Correctamente?
Problema ¿Está la Bomba de
Solucionado Calor Operando
(Verifique que los ajustes de Correctamente?
la temperatura del agua sean
como los seleccionados
Si
Si
Piscina o el Spa seleccionado
para calentar el cuerpo de
Si
Si
Si
Si
Si
No
No
La bomba de calor está
Equipada con un retardador
de 4 minutos. Espere al menos
4 minutos, para que el
temporizador se restablezca
No
Contacte a Aquacal
Para asistencia en el
727-823-5642 o para
asistencia en Español a
HornerXpress Worldwide
En el (954) 938-5355
41
DETERMINACION Y SOLUCION DE PROBLEMAS
DIAGRAMA DE FLUJO
La Bomba de Calor Funciona Pero No Calienta
ARRANQUE¿Es el aire que sale por
encima de la bomba de calor
5°C a 7°C más frío que el
aire exterior?
la temperatura del aire es muy baja para
soportar la operación de la bomba de calor. La unidad se mantendrá en el ¿Está el temporizador
modo de descongelación hasta que la de la bomba de circulación
temperatura vuelva a subir.seleccionado para permitir
una operación extendida de
¿Aparece en la Pantalla MODELOS CALENTAR – ENFRIAR: la bomba de calor?
el código de mensaje“FS”? El código de mensaje “FS” indica que la bomba de calor está modo de
descongelación
NoSi
MODELOS SOLO CALENTAMIENTO
Si “FS” aparece en la pantalla, indica que
Si
No
MODELOS SOLO CALENTAMIENTO:
aire por encima de 3°C por varias horas Extienda las horas de operación
y el código de mensaje “FS” aparece en de la bomba de la piscina para
la pantalla por ése período de tiempo? que la bomba de calor pueda
operar por un período de tiempo
¿Se ha mantenido el código de mensaje más fríos.
de cuatro (4) minutos? (Si es así apague
la bomba de calor).
MODELOS SOLO CALENTAMIENTO:
La temperatura del aire está muy fría
para operar la bomba de calor.
MODELOS CALENTAR – ENFRIAR:
Si el código de mensaje aparece en la
pantalla por 4 minutos o menos,
indica que la bomba de calor está en el
modo normal de descongelación.
¿Se ha mantenido la temperatura del
MODELOS CALENTAR – ENFRIAR: más largo. Requerido en climas
“FS” en la pantalla por un período mayor
No
Si
Si
¿Está la bomba de calor
operando adecuadamente?
SiNo
Problema
Solucionado
No
727-823-5642 o para
asistencia en Español a
HornerXpress Worldwide
en el (954) 938-5355
Solucionado
Contacte a Aquacal
Para asistencia en el
Problema
42
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.