Aquacal Heat Pump User Manual

AquaCal AutoPilot
Pool & Spa Heat Pump
Owner’s Manual and Installation Guide
MODEL /
Attention Installer: This manual is purchaser’s property; leave with heat pump owner!
PN: LTP0048 REV 2
01/07/10
1
NOTES
___________________________________________________________________________________
__________________________________________________________________________________
___________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
___________________________________________________________________________________
__________________________________________________________________________________
___________________________________________________________________________________
_________________________________________________________________________________
__________________________________________________________________________________
________________________________________________________________________________________
___________________________________________________________________________________
____________________________________________________________________________________
_________________________________________________________________________________
__________________________________________________________________________________
_________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
TABLE OF CONTENTS
WELCOME TO THE TEAM ----------------------------------------------5
HEA T PUMP OPTIONS -------------------------------------------------6
HOW A HEA T PUMP WORKS ------------------------------------------7
SAFETY INFORMA TION------------------------------------------------8
QUICK STA RT & STO P-------------------------------------------------10
HEA TER CONTROLS ---------------------------------------------------12
Control Panel Layout -----------------------------------------------12 Buttons, Lights, and Display --------------------------------------12 Operational & Programming Codes--------------------------------13 Owner-Level Programming (complete) ---------------------------14
MAINTENANCE AND GENERAL OPERA TION--------------------------18
General Maintenance-----------------------------------------------18 Safety During Cleaning Operations -------------------------------18 Maintaining Proper Water Flow ------------------------------------19 Controlling Water Chemistry --------------------------------------19 Controlling Irrigation and Storm Water R un Off ------------------20 Maintaining Clearances Around Heater ---------------------------20
(Continued on Next Page)
3
TABLE OF CONTENTS
(CONTINUED)
MAINTENANCE AND GENERAL OPERA TION...CONTINUED:
Heating Tips--------------------------------------------------------21
- Heating in Cooler Weather
Pool/Spa Blankets-----------------------------------------------21
Pool & Spa Combination Heating-------------------------------21
Spa Set-Back Option -------------------------------------------21
Calculating Initial Heating Time-----------------------------------22
Seasonal Use & Shut Down----------------------------------------23
- (Use) During the Swim Season
- Freeze Protection and Winterizing Requirements--------------
- Winterizing Procedure ------------------------------------------
--------------------------------------21
--------------------------------23
23
24
AquaCal Preventive Maintenance Program------------------------25
TROUBLESHOOTING (No Op, No heat, W ater from Unit) ------------26
T roubleshooting Flowcharts----------------------------------------27
INSTALLER- SPECIFIC INFORMATION (Installation & Set Up) ------30
Installer-Specific Table of Contents -------------------------------31
CONT ACTING THE FACTORY ------------------------------------------58
4
Welcome
to the
T
eam
Dear Owner:
ongratulations on your wise decision to make an AquaCal heat pump part of your home. Since 1981, AquaCal has has been recognized as the worldwide
C
leader in the manufacture of swimming pool & spa heat pumps. Y our new heat pump is not only a great investment, but also the most cost efficient method avail­able for heating pools and spas. For ex­ample, your heat pump is up to 400% more efficient than gas, and, when com­pared to electric resistance heat, your heat pump is nearly 600% more effec­tive. Y ou can rest assured your new heat pump is of the highest quality and effi­ciency , and is designed and built to pro­vide years of trouble-free operation.
Moreover, should you ever require help in using or maintaining your heat pump, you will find AquaCal’s customer and technical support staff to be the largest, most qualified, and—of utmost importance—the most easily accessed customer service team in the pool & spa heat pump industry .
“You can rest assured
knowing your new heat
pump is of the highest quality and efficiency,
and is designed and
built to provide years
of trouble-fr ee
operation.”
5
Heat Pump Options
ThermoLink® Heat Exchanger
The heart of your heat pump is the patented ThermoLink® heat exchanger. One of the primary causes of premature heat pump demise is the failure of the heat exchanger. Ordinary heat exchangers are made from a cupronickel alloy . This cupronickel material is susceptible to attack from the sanitizers used in pools and spas and from other related water chemistry conditions. Once the heat exchanger fails, the heat pump is ruined. The ThermoLink® heat exchanger tube is made from titanium, and is virtually impervious to water chemistry damage.
Microprocessor Controller
Digitally-based microprocessor controls water temperature to within 1º Fahrenheit of set point. Controller also permits user to predefine different pool and spa water temper­atures, and to prevent tampering by locking out controls via a pass code. The micro­prosser controller also provides superior defrost control, and self diagnostics.
Scroll Compressor *
50% fewer moving parts than standard piston-type compressors. This equates to much improved reliability and improved efficiency. Scroll compressors are also much quieter in operation than their piston-type counterparts. And, while all AquuaCal heat pumps are known for their low operating noise levels, if yours is a SuperQuietTM model, it’s very likely your heat pump will be quieter than any other item on the pool equipment pad.
Corrosion-Proof Cabinet
The cabinet, being made from resilient, UV-Protected ABS material, has superior fade resistance and can never rust or corrode. You can expect the cabinet to retain a like­new appearance with only an occasional wash down and—if so desired—a quick waxing.
Heat & Cool Capability**
Puts you in full control, year round... Warms your pool or spa with the reliability and efficiency of our other heat pumps, but, with the flip of a switch, can also cool your pool or spa to refreshing temperatures during hot summer months. For cooler climates, Heat & Cool heat pumps offer unique advantages over passive defrost models. Please read more below...
Hot Gas Defrost**
Hot gas defrost heat pumps are uniquely equipped for an active defrost cycle. Active defrost involves directing hot refrigerant v apor to the heat collector, melting accumulat­ed ice away in a matter of a few minutes... then right back to heating. Standard defrost heat pumps may remain “off in defrost” for extended periods during very cold weather. Because of their ability to continue to operate–even during freezing weather–hot gas defrost models extend the swimming season longer than any standard-defrost heat pump.
*
These features available in SuperQuietTM Models Only.
** These features available in Icebreaker
®
Models Only.
PLEASE READ FURTHER TO BECOME FAMILIAR WITH ALL THE FEATURES, THE SAFE
OPERATION, AND THE CARE OF YOUR NEW HEAT PUMP.
6
HOW A HEAT PUMP WORKS
THE FOLLOWING EXPLANATION IS PROVIDED TO HELP YOU IN UNDERSTANDING
WHAT
TO EXPECT FROM YOUR HEAT PUMP
A Heat Pump Does Not Make Heat…
Heat pumps are so extraordinarily efficient because they do not need to produce heat in order to warm pool or spa water. Rather, heat pumps simply transfer heat from the outside air into the water.
If one considers Absolute Zero (the point where all heat is absent) occurs at -459º Fahrenheit, it becomes evident outside air, even at the relative cool temperature of 55º Fahrenheit, still contains large amounts of heat energy. It is that abundant heat energy a heat pump captures and places into your pool or spa.
...
IR
H
EAT
EMOVED
R
OOL
C
A
FROM
O
IR
A
UT
W
ARMED WATER
O
UT
C
OOL
I
W
N
ATER
ADEN
NTERS
L
E
EAT
IR
H
A
7
SAFETY INFORMA TION
Used and maintained properly, your heat pump will provide year-upon-year of safe and economical service. However, as with any mechanical or electrical device, to get the most from your heat pump–while insuring personal safety for you and others–certain operational and maintenance factors must be observed.
Likewise, excepting a few minor owner-capable maintenance items (explained later in this manual), repair and service of your heat pump must be performed only by experi­enced service personnel. Should you, the owner, suspect your heat pump is not per­forming properly, by referring to the section in this manual entitled: "Troubleshooting," you will be able to determine if a call for service is required. Your installer can be one source of service, or AquaCal Customer Support personnel stand ready to assist you at: (727) 823-5642. For questions concerning installation, modifications, operation, service and upkeep, please contact your installer or AquaCal Customer Support. War­ranties may be voided if the heater has been used, maintained, or repaired improperly.
In addition to voiding the manufacturer’s warranty... unapproved installation methods, nonstandard modifications, poor or incorrect maintenance, service by unqualified per­sonnel, or improper use of the heater may result in personal injury and/or property damage. For personal safety, and to avoid damage to equipment, follow all safety instructions displayed on the heat pump and within this manual.
Safety Signals
Throughout this manual the following two safety signals are placed where particular care is required. Please note "WARNING" relates to personal safety, while "CAUTION" signals promote avoiding damage to equipment.
Failure to heed the following may result in perma-
W ARNING !
“Warning” signal appears in this manual where special attention is required for personal safety. (Specific instructions will appear in this box.)
CAUTION !
“Caution” signal appears in this manual where special care is required to avoid equipment damage. (Specific instructions will appear in this box.)
nent injury or death.
Failure to heed the following may result in equipment damage.
8
Notice: Heater NOT Repairable by Owner
Failure to heed the following may result in permanent
W ARNING !
Heat pumps contain no owner-repairable components. Repairs must not be attempted by untrained and/or unqualified individuals. If service is deemed necessary, contact installing dealer or AquaCal Customer Support at (727) 823-5642.
injury or death.
Refrigerant Circuit Service Only by
Qualified, EPA Certified Technician
Failure to heed the following may result in permanent
W ARNING !
Heater contains refrigerant under pressure. Repairs to the refrigerant circuit must not be attempted by untrained and/or unqualified individuals. Service must be performed only by qualified HV AC technicians. Recover refrigerant before opening system.
injury or death.
W ater T emperature Safety
Failure to heed the following may result in permanent
W ARNING !
Prolonged immersion in water warmer than normal body temperature may cause a condi­tion known as HYPERTHERMIA. The symptoms of hyperthermia include: unawareness of impending hazard, failure to perceive heat, failure to recognize the need to exit the spa, and unconsciousness. The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia. In addition, persons having an adverse medical history , or preg­nant women, should consult a physician before using a hot tub or spa. Children and the extreme elderly should be supervised by a responsible adult.
injury or death.
Water Chemistry Safety
Failure to heed the following may result in permanent
W ARNING !
Improper water chemistry can present a serious health hazard. T o avoid possible hazards, maintain Pool/S pa water per standards detailed later in this manual.
CAUTION !
injury or death.
Failure to heed the following can result in damage to equipment.
While your heat pump’s titanium-based heat exchanger provides nearly impervious protection against poor water chemistry , improper water chemistry may cause expensive damage to pump, filter, pool shell, etc. To avoid equipment damage, maintain Pool/Spa water per standards detailed later in this manual.
9
Getting Started
HEATING- QUICK START & STOP
This brief information is provided as an aid to installers, service personnel, and owners. The intent of this section is to provide rapid access to very basic operational information. Individuals who will be routinely using, installing, maintaining, and servicing this heat pump, are strongly encouraged to read this entire manual. Herein, the terms: Heat Pump, Heater, and Unit are used synonymously. These
instructions are intended for local control of a heat pump, independent of an external con­troller. Owners: if your inst allation includes an external controller, cont act your installing dealer , or the external controller manufacturer, for external controller operating instructions.
These instructions are for quick-starting in the HEATING mode... Owners of Heat-Cool units, in order to utilize all features of their heater, may want to also refer to: beginning on page-14 of this manual.
1. Verify Electrical Power is Present at Heater:
A . Ensure that the unit has electrical power connected; the heater controller display should be
illuminated.
B. If the display is blank, be certain the electrical breaker , and heater disconnect, are switched to
“ON.”
C. For now, leave the water circulation pump OFF.
Owner Level Programming,
2. Set the Heater Controls (Refer to Control Panel Layout, Pg-12): OWNER- If heater is connected to a Call-Flex controller, also see “Selecting Call-Flex Pump
Options,” located on page-17 of this manual. INST ALLER- Is heater connected to an external controller? If so, see external controller
information located on pages 41 and 44 of this manual. A. The user/owner settings can be made without water flowing. Once the heater has electrical
power connected, with water not flowing, the display should read FLO.
B. Press the MODE button until the HEA T (HEA) indication displays. This action will enable the
remaining programming keys.
C. Using the POOL / SPA selector key, select the POOL mode. An illuminated POOL indicator
light, located on the left side of the display, will confirm the POOL control has been selected. If heating only a spa, using the DOWN arrow key, lower the POOL temperature until OFF is
displayed; then proceed to Step-“E.” D. Use the UP / DOWN arrow keys to set the desired water temperature for the POOL water. E. If the heat pump will be used to heat a spa, use the POOL/SPA selector key to select SPA,
then use the UP / DOWN arrow keys to set the desired water temperature for the SPA. An
illuminated SP A indicator light, located on the left side of the display, will confirm the SPA
control has been selected. If heating only a POOL, using the DOWN arrow key, lower the
SP A temperature until OFF is displayed. F. The heat pump controls are now set to maintain the desired water temperature for the POOL
and/or SP A.
10
(Quick-Start & Stop Continued Next Page)
HEATING-QUICK START & STOP (continued):
3. To Begin Heating:
A . Verify MODE is set to: HEAT (HEA); then, depending on which body of water is to be heated,
use the POOL / SPA selector key to select POOL or SPA.
B. Position water valves to flow water from the pool or spa, through the heater, and back to the
pool or spa.
C. Start the water pump; the fan will start, and after 4-minute time delay the unit will begin
heating. The selected body of water will be brought to temperature and maintained per the setting determined previously in: “Set the Heater Controls.”
D. In operation, whenever the actual (displayed) water temperature falls below the desired set
point, after an initial time delay of 4-minutes, the unit will begin heating.
NOTE: THE HEATER CONTROLLER INCORPORATES AN ANTI -SHORT CYCLE TIME DELAY. SHOULD OPERATION BE
INTERRUPTED
4. Program Filter Pump Run Time:
Most pool/spa systems utilize a timer or multifunction controller to manage filter pump run times. If your system incorporates such a device, follow the instructions below:
A . It will be necessary to allow the filter pump to run continuously until the water has reached the
desired temperature. If a timer controls the pool filter pump, it will be necessary to override the timer to allow 24-hr. operation.
B. Once the desired temperature has been obtained (1-4 days), reset the pump control
device. Colder months require longer running times - generally eight to twelve hours/day .
C. A heat pump can only operate when the filter pump is running. Therefore, it may be
necessary–during cooler weather–to extend the water pump’s hours of daily operation. The increased run time is necessary in order to keep up with increased, weather-related heat losses.
, COMPRESSOR RESTART WILL BE DELAYED BY APPROXIMATELY 4-MINUTES.
5. Continuous Usage and Water Around Heater:
Condensation... After the heat pump has been operating for some time, water may be observed surrounding the heater. The moisture seen is condensation produced as a normal by-product of transferring heat from the air into the pool or spa water . Quantities of 6-8 gallons of water produced per hour are common if the air humidity is high. Conversely , a low humidity condition may result in no condensation being produced. (If water around unit seems excessive, to troubleshoot, see page-26, “Water Coming from the Heat Pump.”)
6. To Stop the Heat Pump:
A. Select: OFF via the MODE selector. This method of shut down preserves the controller
settings;
B. An interruption of water flow–such as when a pump timer is in control–will also halt heat
pump operation.
(End...Quick-Start & Stop)
11
HEATER CONTROLS
Control Panel Layout
(APPEARANCE VARIES BY MODEL)
Control Buttons, Indicator Lights, & Display
(AS INDICATED BY CIRCLED NUMBERS)
1) POOL / SPA SELECTOR – Selects either pool or spa thermostat.
2) COOLING INDICATOR LIGHT – Indicates unit is cooling. (Note: this light
nonfunctional with heat-only models.)
3) UP ARROW – Increases temperature setting. (Maximum setting is 104
4) DOWN ARROW – Decreases temperature setting. (Minimum setting is 45
5) HEATING INDICATOR LIGHT – Indicates unit is heating.
6) MODE SELECTOR – Used to select between the Heating, Cooling, Auto-
Changeover, and Off for Heat & Cool models. Used to select between Heating and Off for heat-only models.
7) SPA INDICATOR LIGHT – Indicates heater is referencing spa thermostat.
8) POOL INDICATOR LIGHT – Indicates heater is referencing pool thermostat.
9) LED DISPLAY – Displays water temperature when no keys are being pressed.
Displays desired temperature when UP ARROW or DOWN ARROW is pressed. Also displays operational, programming, and fault codes as applicable.
10) DESIRED TEMPERATURE LIGHT – Indicates temperature set point is being displayed. Indicates temperature set point is being changed due to the UP ARROW or DOWN ARROW being pressed.
o
F)
o
F)
12
11) WATER TEMPERATURE LIGHT – Indicates current water temperature is being displayed.
HEATER CONTROLS...continued
Operational & Programming Codes
HE FOLLOWING CODES WILL BE DISPLAYED AS PART
T
OF THE NORMAL OPERATION OR PROGRAMMING OF THE HEATER:
FLO..... No Water Flow Detected. This code appears whenever the circulating pump is off, or when
the heater is not receiving correct water flow.
OFF..... System is Off. This code appears whenever heater has been turned off via the mode
selector button, or when the temperature set point has been lowered below 45
CFI...... Celsius/Fahrenheit Selection. This is a programming entry point to select in which format
the water temperature will be displayed.
ULC..... User Lock Code. This is a programming entry point; when activated, steps to the next
menu level: ELC.
ELC..... Enter Lock Code. This a programming entry point; permits end user to select a secret
code, thereby limiting access to the owner settings.
CFO..... Call Flex Options. This is a programming entry point; when used in conjunction with an
AquaCal Call/Flex option kit, permits the use of CALL or FLEX options.
FS....... Heater in Defrost Mode (Applicable to Heat-Only Units, only). This code appears as a
normal display during periods of lower air temperatures. Sequence follows: Heat-Only Defrost Sequence: Fan continues to run and compressor is off. Compressor
will restart when air coil temperature rises to approximately 38°F .
o
F.
LOC..... This is a Service Entry Point (not intended for use by the owner). The[LOC] code permits
service personal to enter a factory code for access to adjustable calibration and site­dependant setup parameters. Service adjustments are available to authorized installation and service personnel, only.
CAUTION !
Heat pumps contain no owner-serviceable components. Owner-initiated adjustments, beyond the controller “LOC” code, must not be attempted. If adjustments are deemed necessary, the owner should contact installing dealer or AquaCal Customer Support at (727-823-5642).
Failure to heed the following may result in equipment dam­age and voiding of manufacturer’s warranty.
13
HEATER CONTROLS...continued
Start Up & Setting Operating Controls
Owner-Level Programming Instructions
This section covers features and settings topically accessed first by the installer , and also accessible to the owner/operator. These features reside at the Level-1 access point within the microprocessor. Note: if preferred, all programming may be performed without water flow, waiting to start the water pump as the last step in the set up and run process.
1. Applying Power to The Controller:
A
. When power is first applied, the controller performs a lamp test and the display will read
[888]. Following [888] the software version will display briefly .
B. The control will then display the actual water temperature, provided the circulating pump is
operating, and adequate water is flowing through the heater.
C. If the pool-circulating pump is off, the control will display: [FLO]. This code message
indicates no (or insufficient) water is being circulated through the heat pump.
2. MODE Controls Explained, and Starting the Heat Pump
Once electrical power is supplied to the heat pump, sufficient water is circulating, and the heater controller has successfully completed its self-test, the heater is ready to operate. The heat pump has four controller operating "Modes"; OFF
OFF - The heat pump is shipped in the OFF mode. When the heat pump MODE is set to
OFF, the current water temperature will be displayed and no functions, values, or programming will be available for adjustment. If there is insufficient water flow , the unit will display FLO.
, HEA T, COOL*, and ACH* (Auto-Change Over).
HEA T - To turn the unit on in heat only mode, press the mode button to HEAT. The display
will show the actual water temperature. Press the UP ARROW key to set the desired temperature. After the desired temperature is set, the unit will again display the actual water temperature. If the set temperature is above the actual water temperature, the heat pump will start and continue to heat until the desired temperature is reached. The heat pump will periodically turn on, calling for heat as needed in order to maintain the set temperature until the mode is changed back to OFF. PLEASE NOTE - both the compressor and the fan must be operating before the “Heating” LED will illuminate.
COOL
ACH* - To have the heat pump maintain a particular temperature, regardless of the
3. Turning The Heat Pump Off:
A. Method 1: using the [MODE] key, press the key until the display reads “OFF” The
heater will shut off and remain off until the [MODE] key is used to select an operational mode. This is the preferred method for shutting off the heat pump.
*
- To turn the unit on in cooling mode, press the mode button to COOL. The display will show the actual water temperature. Press the UP ARROW key to set the desired temperature. After the desired temperature is set, the unit will again display the actual water temperature. If the set temperature is below the actual water temperature, the heat pump will start and continue to cool the water until the desired temperature is reached. The heat pump will periodically turn on to cool the water as needed until the mode is changed back to OFF.
temperature of the water, press the mode button to ACH. The heat pump will turn on in either heat or cooling mode to maintain that temperature as needed until the heat pump mode is changed to OFF.
14
*
These features available in Icebreaker
®
Models Only.
(Continued on Next Page)
HEATER CONTROLS...continued
Start Up & Setting Operating Controls
Owner-Level Programming Instructions... continued:
3. Turning The Heat Pump Off... continued:
B. Method 2: using the DOWN key , press the key until the desired water temperature reaches
o
45
F (minimum setting); then, press the DOWN key one more time, causing the display to
read “OFF”.
4. Selecting Pool/Spa Thermostat Settings:
A . Press the [POOL/SPA] key to toggle between the pool and the spa temperature set points. B. The pool/spa LED indicator lights, located to the left of the temperature display, will confirm
the selected set point.
5. Changing The Pool Temperature Set Point:
A . Using the [POOL/SPA] key, select the POOL temperature set point. The pool set point
indicator light will confirm the selection.
B. The pool temperature set point is adjustable from a minimum of 45
o
F to a maximum of 104oF. Pressing the [UP ARROW] key will raise the set point 1-degree for every push of the button. Pressing the [DOWN ARROW] key will lower the set point 1-degree for every push of the button.
6. Changing The Spa Temperature Set Point:
A . Using the [POOL/SPA] key, select the SPA temperature set point. The spa set point indicator
light will confirm the selection.
B. The spa temperature set point is adjustable from a minimum of 45
o
F to a maximum of 104oF. Pressing the [UP ARROW] key will raise the set point 1-degree for every push of the button. Pressing the [DOWN ARROW] key will lower the set point 1-degree for every push of the button.
7. Selecting Between oF and oC:
A. Simultaneously press and hold both the [UP ARROW] and [DOWN ARROW] keys until
[CF1] (Celsius / Fahrenheit) code appears.
B. With the [CF1] code displayed, pressing the [UP ARROW] or [DOWN ARROW] keys will
change the selection code to either “0” or “1”. Select “1” for Fahrenheit temperature display , or “0” for Celsius temperature display. Once the desired temperature display mode has been selected,
not pressing any buttons for 15-seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the {POOL/SPA] key will also save the selection and step to the next menu parameter: [ULC] (User Lock Code).
8. User Lock Code Option [ULC]:
This Option Explained: Heat pumps are shipped from the factory with the [ULC] option disabled. Enabling the [ULC]
function permits the heat pump owner to restrict access to the unit’s controls. With the [ULC] function enabled, unless the correct ULC code number is entered, changes to Level-1 programming are not possible. (I.e.: Altering temperature set point s, Pool/Spa selection, C/F display changes, etc., will not be possible). The [ULC] option can be thought of as an electronic lockable cover for the controls.
(Continued on Next Page)
15
HEATER CONTROLS...continued
Start Up & Setting Operating Controls
Owner-Level Programming Instructions... continued:
8. User Lock Code Option [ULC]...continued:
A.
Selecting ULC Option:
1) Press either the UP or DOWN ARROW keys; if “LOC” is momentarily displayed followed by “0”, the ULC feature is enabled. If “0” displays proceed to “6)” of this section; otherwise, see number “2,” below.
2) Simultaneously press and hold both the [UP ARROW] and [DOWN ARROW] keys until [CF1] (Celsius / Fahrenheit) code appears.
3) Press the [POOL/SPA] key once to display [ULC].
4) With [ULC] displayed, pressing either the Up or Down Arrow key will display either “1” or “0”. Selecting “0” will allow the keypad to remain unlocked. Selecting “1” will enable the User Lock Code option. Then, to enter a lock code number, press the [POOL/SPA] key once to display [ELC] (Enter Lock Code).
5) With [ELC] displayed, use the Up or Down arrow keys to select a lock code. The code can be any number from “00” to “99”. The factory set lock code is “0”. Not pressing any buttons for 15-seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the {POOL/SPA] key will also save the selection, and will step the controller to the next menu parameter: [CFO] (Call Flex Options).
6) Once the ULC option has been enabled, pressing any key will momentarily display “LOC” followed by “0” (prompting the entry of the correct lock code number). To gain access to the controller:
a. Using the [UP ARROW] key, scroll to the correct lock code number, then; b. Press the [POOL/SPA] key… Current water temperature will be displayed… Control
setting can now be viewed or changed as desired.
c. After a period of approximately four (4) minutes, during which time no buttons have
been pressed, the controller will automatically return to the locked mode. Provided ULC selection is set to “1,” the controller will always fail-safe in the locked mode.
d. Without knowledge of the correct lock code, and with the ULC enabled, control
adjustments will place. The lock code may be changed any number of times by following the instructions detailed in this section.
B. De-Activating the User Lock Code [ULC] function:
1) Following the instructions detailed previously at: “8, 6)”, press any key and enter the user lock code number; then press the [POOL/SPA] key.
2) Immediately following the entry of the user lock code, simultaneously press and hold the [UP ARROW] and [DOWN ARROW] keys until the code [CF1] appears on the display.
3) Then, use the [POOL/SPA] key to scroll to the [ULC] message; press the [DOWN ARROW] key to change the display to “0”. This will disable the User lock function.
not be possible. Be certain to record your lock code in a safe
16
(ULC Continued on Next Page)
HEATER CONTROLS...continued
Start Up & Setting Operating Controls
Owner-Level Programming Instructions... continued:
User Lock Code is Activated, but Pass Number is Not Known (“Back Door Entry”):
C.
Note: Should the ULC option be enabled, and a lock code number other than the factory default (0) be installed but is unknown, the following procedure may be followed to regain controller programming access:
1) Simultaneously press and hold the [POOL/SPA] and [UP ARROW] keys until the display
shows “888”. This operation will reset the controller to the factory default settings.
2) When reset to the factory default settings the user lock code [ULC] is deactivated and
the user lock code number [ELC] is reset to “0.”
3) In addition, all other settings are returned to the factory defaults. If an external
controller is in use, contact AquaCal Technical Support Group (727-823-5642); ask for assistance with re-configuring the controller for use with an external controller.
9. Selecting Call-Flex Pump Options [CFO]:
General Information:
The Call-Flex option automatically extends or overrides the run time of the water circulator pump, and heater grow progressively cooler during winter months, or when unusually cold weather occurs, the run duration of the circulator pump may require manual adjustments to permit the heater to maintain or reattain desired water temperature (the water pump must be running in order for the heater to operate). Likewise, without Call-Flex, one must remember to reset the pump run controls following the cold weather event. The Call-Flex option greatly reduces the need for seasonal, manually made, pump run time adjustments. Call-Flex is a dealer-installed option that does not come with every heater; if unsure, check with the installing dealer to determine if a call-flex kit was part of the original installation. If Call-Flex was not part of the installation, and you would like to have
Call-Flex added, your dealer can do so...contact the installing dealer . If the installation is equipped with the Call-Flex option, the following steps are used to control the
Call-Flex features: A. Simultaneously press and hold the [UP ARROW] and [DOWN ARROW] keys until the
display shows “CF1”. Press the [POOL/SPA] key three times to scroll the display to [CFO].
B. With the [CFO] (Call-Flex Options) code displayed, use the Up or Down keys to select “0” to
disable the Call Flex Options, “1” to enable the Call Option, or “2” to enable the Flex Option. Not pressing any buttons for 15-seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the {POOL/SPA] key will also save the selection, and will step the controller to the next menu parameter: [LOC] (Service Lock Code).
, based upon changing weather conditions. Without Call-Flex, as weather conditions
C. For further information, please refer to Call-Flex installation instructions, shipped with the
Call-Flex kit. For additional copies of these instructions, contact the AquaCal Customer Support (727-823-5642).
(End... Owner-Level Programming Instructions)
17
MAINTENANCE
&
OPERATIONAL RECOMMENDA TIONS
The information in this section is written primarily for the Home Owner, but may also apply to servicing dealers or HV AC service centers. This section contains information concerning planned maintenance, proper water flow, maint aining proper clearances, as well as other vital information. Please read this section now, and before calling AquaCal Customer Support (727-823-5642).
General Maintenance
Heat pumps should be inspected and maintained on an annual basis by a qualified swimming pool heat pump specialist. Additionally, if the heat pump is located near the beach or coastal area, where salt spray and sand can become detrimental factors, more frequent service may be necessary. For service plan information, please see: contact AquaCal Customer Support at: 727-823-5642.
Planned Maintenance Program, later in this section, and then
While annual maintenance is recommended to maintain your warranty , if you choose in the Planned Maintenance Program, rinsing the air coil regularly, and keeping the base of the unit clear of leaves and debris is a necessity.
Should you as the owner desire to perform the coil rinsing and other cosmetic care of the heat pump, please contact AquaCal Customer Support: 1-727-823-5642; request the document titled: “ Care for Air-Source Heat Pumps: Approved Method for Home Owners.”
not to participate
Appearance
Safety During Cleaning Operations
Failure to heed the following may result in permanent
W ARNING !
POSSIBLE ELECTRIC SHOCK HAZARD . . . Should you decide to wash the heat pump via water hose, disconnect all power to the pool equipment pad- including, but not limited to: The heat pump, water pump, and any and all other electrical equipment. Do NOT spray water directly into electrical components. Do NOT restore electrical power until such time as all water has dried completely .
injury or death.
18
Failure to heed the following may result in damage to
CAUTION !
Do not use a pressure cleaner to wash heat pump . . . . Damage to evaporator fins, as
well as other components, will result.
equipment.