APW Wyott ICP-400 Installation Manual

ELECTRICAL
THERE ARE NO ELECTRICAL COMPONENTS IN THIS UNIT.
INSTALLATION INSTRUCTIONS
ICE COOLED COLD PAN
MODEL ICP-400
57
(1448)
23 7/8
(606)
(1346)
58 1/2
(1486)
PRODUCT DIMENSIONSCUTOUT DETAILS
19 7/8
(505)
53
8
(203)
25 3/8
645
9
229
(MM)
INCHES
CLEARANCES
THERE ARE NO CLEARANCE SPECIFICATIONS FOR THIS UNIT.
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole and add stiffeners to support weight of unit if necessary. Countertop must be flat and level before installing cold pan.
3. apply a generous bead of silicone sealant to underĀ­side of mounting flange before setting unit into cutout. Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain. Consult local codes for approved drain connections.
WELLS/BLOOMFIELD * VERDI, NV
9
(229)
1
(25)
1/4
(6)
1" NPT DRAIN CENTERED IN PAN
3/4
(19)
CROSS-SECTION OF COLD PAN
2 3/4
(70)
49406-4 REV (-)
(203)
1" HIGH REMOVABLE PERFORATED BOTTOM
8