ELECTRICAL
THERE ARE NO ELECTRICAL COMPONENTS IN THIS UNIT.
INSTALLATION INSTRUCTIONS
ICE COOLED COLD PAN
MODEL ICP-100
CUTOUT DETAILS PRODUCT DIMENSIONS
19 7/8
(505)
23 7/8
(606)
11 7/8
(302)
17 3/8
(441)
15 7/8
(403)
8
(203)
INCHES
(MM)
25 3/8
(645)
9
(229)
CLEARANCES
THERE ARE NO CLEARANCE SPECIFICATIONS FOR THIS UNIT.
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole and add stiffeners to support weight of
unit if necessary. Countertop must be flat and level
before installing cold pan.
3. apply a generous bead of silicone sealant to underĀside of mounting flange before setting unit into cutout.
Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain.
Consult local codes for approved drain connections.
WELLS/BLOOMFIELD * VERDI, NV
9
(229)
1
(25)
1/4
(6)
1" NPT DRAIN
CENTERED IN PAN
3/4
(19)
CROSS-SECTION OF COLD PAN
2 3/4
(70)
1" HIGH REMOVABLE
PERFORATED BOTTOM
49406-1 REV (-)
8
(203)