Aprilaire 700 Installation Manual

Return
Supply
Hot Water
Drain Line
Floor Drain or Condensate Pump
Supply
Model 700 Series Humidifier Template
ATTENTION INSTALLER
Read this installation template before installing humidifier. Warranty is void unless humidifier is installed by qualified heating and air conditioning contractor due to possible misapplication of product. This product must be installed in compliance with all local, state, and federal codes. Proper humidification and humidity control require that the home be constructed with local codes and good building practices.
WARNING
ELECTRICAL SHOCK HAZARD. Disconnect power to the
furnace before installing humidifier.
CAUTION
SHARP EDGES. Use care when cutting and handling
ductwork.
HOT WATER CAN SCALD. Shut o hot water supply before tapping into hot water supply.
NOTICE
FREEZING TEMPERATURES CAN BURST WATER PIPES.
Do not install humidifier where freezing may occur.
CONDENSATION DAMAGE OR MOLD CAN OCCUR.
SPECIFICATIONS
Humidifier Dimensions:
Width: 15-29/32" Height (including solenoid valve and drain spud): 18" Depth: 10-11/32"
Plenum Opening: 14-3/4"W x 14-5/16"H Water Feed Rate: 3 gph Electrical Data: 24 VAC, 60 Hz, 0.8 Amp Water Panel®: Model 35
FURNISHED ITEMS
• 24 VAC transformer
• Automatic Digital Humidifier Control and Outdoor Temperature Sensor (Model 700 only)
• Manual Humidifier Control (Model 700M only)
• Humidifier Control Installation Instructions
• Saddle valve
• Humidifier Installation Template
ITEMS NOT FURNISHED
• Mounting screws (sheet metal screws)
• Water supply line (1/4" O.D. copper)
• Drain line (1/2" I.D. hose)
• Low voltage wire
• Model 50 current sensing relay (if required)
INSTALLATION OPTIONS
Aprilaire® Model 700 and 700M can be installed on either the supply plenum or cold air return of a forced air handling system. The humidifier dimensions and serviceability must be considered when selecting the best location for the humidifier.
Hot water is recommended (140°F max) to provide maximum evaporative capacity. It is also recommended when the Blower Activation Feature is used with an Automatic Digital Humidifier Control, or on a heat pump system. The humidifier functions with cold, hot, softened, or unsoftened water.
RECOMMENDED RECOMMENDED ALTERNATE
Return
Supply
Install humidifier as shown in relation to cooling coils
Drain Line
Floor Drain or Condensate Pump
Return
Supply
Drain Line
Floor Drain or Condensate Pump
Hot Water
Drain Line
Floor Drain or Condensate Pump
Return
90-2232
Locate return duct mounted humidifier control at least 6" upstream of humidifier, or fresh air intake for accurate humidity sensing.
Locate wall mount humidifier control in areas unaected by drafts or heat sources for accurate humidity sensing.
Reduce the setting on the humidifier control if condensation forms on windows or in unheated spaces.
EQUIPMENT DAMAGE MAY OCCUR.
Do not install humidifier on the furnace jacket.
Do not connect the power cord to multi-speed furnace blower motors or blower motors other than 120 VAC. Use Aprilaire Model 50 Current Sensing Relay. Do not alter 120 VAC plug or hardwire the unit.
Do not install the humidifier on a plenum face at the blanked end of the cooling coil.
If water pressure exceeds 125 psi, reduce water pressure with devices allowed by local codes.
Do not use water with temperature greater than 140°F.
Do not install humidifier on systems with dierential pressure greater than 0.4 w.g. between the supply and return plenums.
When installing the humidifier control on the return duct of a downflow furnace, ensure the blower continues to run after a heat call is satisfied.
PARTS LIST
1. Front Cover
2. Base
3. Orifice Plate
4. Motor Mount Bridge
5. Scale Control Insert
6. Water Panel®
7. Water Distribution Tray
8. Fan Blade
9. Motor
10. Motor Mount Gasket
11. Relay
12. Power Cord
13. Strain Relief Bushing
14. Solenoid Valve
15. Connector Plug
16. Feed Tube
17. Nozzle
18. Relay Connector
19. Transformer
20. Strainer
21. Orifice
2
20
14
15
5
21
19
7
17
16
6
3
8
4
1
18
10
9
13
12
11
TEMPLATE MUST BE LEVEL
90-1436
Automatic Mode
Transformer Provided with Humidifier
Brown Wires
of cooling
INSTALLATION INSTRUCTIONS
7a7b7c861432
5
Level
Remove the Water Panel® evaporative assembly.
Detach the cover assembly by lifting the latch at the bottom.
90-2296 90-923
OR
Cut opening using this template.
Template
Do not position opening in front
coils.
90-2248
90-924
Position base in duct opening top-first
so hooks engage sheet metal at top.
Insert bottom of base and slide down
to engage hooks at bottom.
90-925
Rotate swing locks to
secure base to duct.
Secure base with screws.
90-926
Tighten water line by double wrenching.
MODEL 700 DIGITAL HUMIDIFIER CONTROL WIRING MODEL 700M MANUAL CONTROL WIRING
North, East
or West Side
of Home
Outdoor
Temperature
Sensor for
Above Expected
Snow Line
Location of manual humidifier control in living space.
NOTE: Control will display software revision level
i.e. r1, when the one minute test cycle has completed. Refer to the control installation manual for system checkout instructions.
R
C
G
Y
W
Thermostat or
Zone Panel
Equipment Terminals
R
C
G
Y
W
Furnace
90-1666
Locate manual or digital humidifier control on
the return at least 6" above the humidifier.
ADHC Terminal Strip
CR H HODT Gf
OUTPUTSINPUTSPOWER
GW
Continuously Powered 24 VAC
6"
120 VAC Outlet
Connect Drain Line Here
Connect to Hot Water Supply
120 VAC
90-2248 90-2248 90-2248
Locate manual or digital humidifier control
Completed installation.
on the return.
IMPORTANT: Use 120 VAC power source other than furnace
motor circuit. However, the transformer can be powered off the hot 120 VAC line before it enters the furnace. Do not wire
transformer into furnace blower circuit.
24 VAC Furnace Accessory
Brown Wires
90-1514
Terminals Or Transformer
(10VA Minimum)
Water Supply
COMMON
HI
LO
Furnace Blower Motor
Model 50
Current Sensing Relay
(if required)
IMPORTANT: When Model 50 current sensing
relay is used, wire Model 50 current sensing
relay into 24 VAC humidifier control circuit only! Do not install in transformer primary circuit.
120 VAC Outlet
Connect Drain Line Here
Shut-o
(Saddle Valve)
Drain Spud
Hose Clamp
Drain Line
Floor Drain or Condensate Pump
INSTALLATION CHECKLIST
90-1208
Drain Line:
• Ensure downward slope and no kinks.
• Do not over­tighten hose clamp onto drain spud.
• Do not use solvent adhesive on drain spud.
  Saddle valve is
fully open.
  All plumbing
connections are watertight.
  Unit is plugged
into 120 VAC outlet.
  Humidifier
functions properly.
  Owner’s manual
has been given to homeowner.
AprilairePartners.com
Printed in USA ©2020 Aprilaire –Division of Research Products Corporation 10008976 B2205118G 5.20
P.O. Box 1467 Madison, WI 53701-1467
800.334.6011 F: 608.257.4357
TEMPLATE MUST BE LEVEL