Aprilaire 600 User Manual

Page 1
READ AND SAVE THESE INSTRUCTIONS
AUTOMATIC HUMIDIFIER
The Best Cure For Dryness
®
®
OWNER’S MANUAL
FOR MODELS 400, 600, & 700
Includes Safety, Operating and Maintenance
Instructions and Warranty
TABLE OF CONTENTS
Introduction............................................................................1
Principle of Operation ............................................................2
Operating Instructions
•Automatic Mode................................................................4
Effect of Water Characteristics ..............................................8
Annual Maintenance ..............................................................9
Annual Summer Shutdown ....................................................9
Periodic Preventative Maintenance .......................................9
MAINTENANCE INSTRUCTIONS
Models 400.......................................................................11
Model 600 ........................................................................12
Model 700 ........................................................................13
Limited Warranty..................................................................14
Replacement Record .....................................................18, 19
PAGE
Page 2
WARNING!
120 volts may cause injury from
electrical shock. Disconnect power and shut off water supply before servicing.
CAUTION!
Sudden operation may cause
personal injury or property damage. Turn the Aprilaire Humidifier Control to “OFF” or lowest setting before servicing
INTRODUCTION
Thank you for your recent Aprilaire®Humidifier purchase. We sincerely appreciate your business and are pleased to add your name to our growing list of customers. With this purchase, you have invested in the highest quality equipment currently available. Research Products Corporation is the largest manufacturer of whole house humidifiers, air cleaners and fresh air exchangers and is a recognized leader in the heating and air conditioning industry today.
Please be assured that in addition to product quality, we are also committed to unit performance as well as customer satisfaction. Your unit will require periodic maintenance to assure you of continued fine performance. Please proceed as shown on page 7 to obtain service parts and/or replacement Water Panel
®
evaporators.
Now, please take a few minutes and read the appropriate section of this booklet. This will familiarize you with the benefits you will receive from the equip­ment you just purchased and help you understand the routine maintenance that will be required. Be sure to register your warranty with us for our records and your protection. You may do so by returning the Warranty Information Card to us, or you can register online at: www.aprilaire.com/warranty.
Genuine Replacement Water Panel evaporators are available from your installing contractor or from most other local heating and air conditioning contractors in your area. However, if you still have difficulty in obtaining a replacement Water Panel evaporator, use the dealer locator in our web site (www.aprilaire.com) or look in the Yellow Pages under Humidifying Apparatus or Heating & Air Conditioning Contractors. Purchase only genuine Aprilaire Water Panels to maintain performance.
© Research Products Corporation 2000
- 1 -
Page 3
I. PRINCIPLE OF OPERATION
®
With your purchase of a humidification system, you have invested in a humidifier that operates on the evaporative principle – nature’s own way of adding moisture – and will provide the proper relative humidity all during the heating season. It is very possible that you have questions concerning your new humidifier – questions on what it can do for you, and what you should do to receive maximum benefits from it. This booklet is intended to help you do exactly that.
Nature, in producing an invigorating comfortable April day, com­bines just the right temperature and the right amount of moisture. Aprilaire Humidifiers employ the same principle, with refinements, to give you the proper relative humidity for maximum allowable com­fort all winter long.
The important considerations in the evaluation of a humidifier are Positive Control, Sufficient Capacity, Trouble-free Performance and Minimum Maintenance. The operating principle of your Aprilaire provides all of these advantages. Here, briefly, is the method:
The Aprilaire Humidifier is installed to operate in conjunction with the furnace blower motor. When the Aprilaire Humidifier Control calls for humidity and the blower motor is operating, water flows to the distribution tray located at the top of the unit. The water is uni­formly distributed across the width of the tray and through a scien­tifically designed system of outlets. It flows by gravity over the
®
Water Panel
evaporator, the heart of the unit. Dry, hot air is moved through the moisture-laden Water Panel evaporator where the evaporation takes place. The now humidified air carrying moisture in vapor form (nature’s own way) is circulated throughout the home.
The correct water flow is determined by an orifice equipped with each drain type unit. When the unit is operating, there will be a small, steady stream of water to drain, which flushes away most of the trouble-causing minerals. Do not use the saddle valve
to regulate the water flow. It is designed to be completely opened or closed. The minerals and solid residue not trapped by the replace­able Water Panel evaporator are flushed down the drain. The drain also eliminates the problems caused by stagnant water. This is the most effective and least expensive method to dispose of trouble­causing minerals.
- 2 -
Page 4
There are some homes where drain facilities are not accessible or available. For these situations, or where high water hardness is not a problem, the newest Aprilaire, Model 400, is designed to satisfy these applications.
Capacity is high because an average-size home (10,000 cu. ft.) requires the addition of approximately 9 gallons of water per day to maintain 35% relative humidity when the outside temper­ature is 20°. The smallest Aprilaire Humidifier under most operating conditions, has this humidifying capacity. Trouble-free perfor­mance and minimum maintenance are assured by the design fea­tures of the Aprilaire Humidifier. All unit housing parts that come in contact with water are non-metal and will never rust or corrode. Neither heat nor water will affect them under normal operating con­ditions.
The Water Panel evaporator, designed especially for uniform, high evaporation, and the Scale Control Insert also efficiently traps mineral deposits which are often the cause of damage to working parts in ordinary humidifiers. No “white dust” can be distributed throughout the living quarters. The Water Panel evaporator is the heart of the unit and must be in good condition to assure high capacity trouble-free performance. It should be changed once a year with the exception of the Model 400 where it should be changed twice a season.
The granular coating in the bottom of the distribution tray is designed to provide equal distribution of the water to each of the openings assuring an even flow of water over the Water Panel evap­orator. Do not clean the mineral scale off the bottom of the water distribution tray at the end of the humidification season. The scale itself provides an excellent track for the water to follow. This is actu­ally what we try to simulate with the synthetic coating in the bottom of the tray. If the coating is removed, it is not necessary to purchase a new distribution tray or upper housing. You can accomplish the same uniform performance by applying a small amount of liquid dish­washing detergent over the entire inside surface of the water distribu­tion tray. This will allow the water to flow evenly through each of the openings, provided, of course, the unit is level in order to achieve maximum capacity.
There are many humidifiers on the market. They all add moisture . . . with varying degrees of efficiency. None, however, can provide the features, design, and performance incorporated into your Aprilaire Humidifier.
- 3 -
Page 5
II. OPERATING INSTRUCTIONS
There are 2 possible modes of operation of your Aprilaire Humidifier Control and an explanation of both modes follows:
Automatic Mode: (Manual Mode-see pg 5)
Your Aprilaire Humidifier Control is installed in the cold air return. During the first heating season, your Humidifier Control needs to be set initially to match your home’s condition. Please follow these steps when adjusting your control (refer to Figure A).
1. Turn the dial setting knob to “5,” which is within the normal range.
During the next 24-48 hours it may be necessary to adjust the dial for more or less humidity, depending on your personal comfort and home’s requirements. Refer to the “Operation Guide” (Table 1).
2. During the coldest portion of the first heating season, minor
(Table 1) Operation Guide
Condition Solution
Condensation on windows Reduce the setting on the control dial
by 1 increment.
Lack of humidity Increase the setting on the control dial
by 1 increment.
Humidifier does not operate Turn dial to “Test.” Make certain furnace
blower is operating and furnace is calling for heat. If unit still doesn’t operate, consult a heating contractor.
Humidifier won’t shut off Turn dial to “Off.” If unit continues to
operate, consult a heating contractor.
Test mode System operation is checked by setting the
knob to “Test.” Make certain furnace blower is operating and furnace is calling for heat. Humidifier will operate for one minute.
- 4 -
Page 6
Off
7
6
5
4
3
2
1
T
e
s
t
N
O
R
M
A
L
The relative humidity in
(Figure A)
your home will now be accurately controlled to meet your needs and should not need further adjustment during future heating seasons. Make note of the dial setting in the event you temporarily move the knob when performing annual maintenance of the Aprilaire
Automatic Mode
Humidifier
adjustments may be necessary. This is dependent upon your individual home construction, refer to the “Operation Guide” (Table 1).
Your Aprilaire Automatic Humidifier, is a high precision system that will accurately maintain the relative humidity in your home. For every 1º change in outdoor temperature, the control will
1
automatically adjust the indoor relative humidity (RH) by
/2%. If you would like to determine the RH in your home, follow these steps:
1. Determine the outdoor temperature.
2. Activate the furnace blower by setting your thermostat fan
switch to the “On” position, or setting your thermostat to a higher temperature.
3. Turn the control dial setting to the “Off” position. Then, slowly
turn the dial clockwise until you hear the solenoid valve “click on.” Next, slowly turn the dial counter clockwise until you hear the solenoid valve “click off.” At this point, make note of the dial setting.
4. Locate your dial setting on Table 2. Follow the dial setting to
the right until it intersects with the current outdoor temperature. This is the relative humidity in your home under existing conditions.
5. Return the thermostat and the control to their original settings.
The Automatic Humidifier will accurately control the humidity in your home to a maximum of 45% RH and a minimum of 10% RH. The values of outdoor temperature and dial settings may fall in
- 5 -
Page 7
(Table 2) % Relative Humidity Guide
Outdoor Temperature (ºF)
-10 0 10 20 30 40
1 101010152025
2 101015202530
3 101520253035
4 152025303540
Dial Setting
520253035 40 45
6 253035404545
7 303540454545
As an example, if the outdoor temperature is 20º F, and, following step 3, the humidifier turns off at “5” on the dial range, then the RH in your home is 35%.
between or outside of the listed values in Table 2. In these cases, you can only approximate your home’s actual indoor RH.
Manual Mode: (Automatic Mode – see pg 3)
Your Aprilaire Humidifier Control is installed in the cold air return. It is important to anticipate a drop in outdoor temperature and reduce the setting accordingly to avoid excessive condensation. For exam­ple, with an outdoor temperature of 20° the correct setting will be 35% relative humidity. If the temperature is expected to fall to 0° that evening, then merely reduce the setting to 25% several hours prior to the temperature change.
The recommended settings on the humidistat are based on years of research (see table 3) and experience as to what is best for the average home. These settings represent a compromise between RH levels that would be most desirable for comfort reasons and humidity levels that are suitable for protection of your home and to avoid condensation on your windows. For example, a wintertime indoor RH of 50% may be considered ideal, but unfortu­nately, it probably would result in damage to your home. Observance of the recommended RH levels on your humidistat, therefore, is an important safeguard. Condensation of water on inside windows in the form of fogging or frost is usually an indica-
- 6 -
Page 8
(Table 3) Outdoor-Indoor Relative Humidity
Outside Temperature Recommended RH
+40° 45%
+30° 40%
+20° 35%
+10° 30%
25%
–10° 20%
–20° 15%
tion of too high relative humidi-
(Figure B)
ties. This same condensation can take place in other areas in your home with the possibility of dam­age resulting.
The humidistat is a precision instrument that can be used to determine the RH accurately in your home during the winter. Turn the dial to the lower setting, then
MANUAL MODE
reverse the dial direction slowly until you hear the solenoid valve “click on”. At this point, read the RH on the dial. This will be very close to the actual RH in your home. (See Figure B)
To check the humidifier operation, set the knob to “test”, make sure that the water saddle valve is open and that there is electricity to the unit. Generally, the furnace blower motor must be operating for the Aprilaire Humidifier to function. After the humidifier has oper­ated for one minute and water is entering the unit and coming out at the drain, reduce the humidistat setting to the recommended inside relative humidity, depending on the outside temperature. DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE. Follow the suggested settings prior to a drop in the outside temperature.
- 7 -
Page 9
Additional Information
Be sure to keep fireplace dampers closed when not in use. They provide an excellent escape route for heat, as well as humidity. Humidity is lost at an even faster rate than heat because water vapor tends to seek its own level and your humidifier would not be able to replace it even when running at full capacity.
On occasion, indoor moisture producing activities such as clothes drying, cooking, showers, etc., may raise the relative humidity level higher than it should be, even though the Aprilaire Humidifier is not operating. Telltale indications, again, are con­densation or frost on cold surfaces such as windows, doors, walls, etc. If such condensation persists for several hours, your home should be ventilated to dissipate the potential damaging excess moisture levels.
III. EFFECT OF WATER CHARACTERISTICS
Your humidifier will operate effectively using either hot, cold, hard or mechanically softened water. Whether to use available tap water, even though it may be quite hard, or chemically softened water, is a common concern to homeowners when installing a humidifier.
Water used in homes contains varying amounts of minerals. The residue remaining as a result of hard water evaporation is primarily calcium and magnesium components and is usually quite hard, scaly, and dense.
Residue from softened water tends to be soft and fluffy and has a greater volume than hard water scale. The service life of a Water Panel evaporator may be extended by using hard water. In either case, the Water Panel evaporator is usually changed once a year with the exception of the Model 400 where it should be changed twice a season. Service hot water, 140° maximum, is recommended with drain type units for increasing capacity and for heat pump applications.
In the drain-equipped models, most of these solids are effectively controlled by flushing them down the drain.
- 8 -
Page 10
IV. ANNUAL MAINTENANCE
For best performance, we recommend that you replace the water panel evaporator in your Aprilaire Humidifier annually with the exception of Model 400 where it should be changed twice a season.
• Call the installer of your Aprilaire Humidifier. This information is
often found on your equipment.
• Call your heating and air conditioning dealer.
• Use our “Dealer Locator” at: www.aprilaire.com
• Look in the Yellow Pages under Humidifying Apparatus
or Heating & Air Conditioner Contractors.
• If none of the above is successful and you still need
information, please feel free to write us.
• Purchase only Genuine Aprilaire Water Panels to maintain
performance.
V. ANNUAL SUMMER SHUTDOWN
1. For Models 400, and 600 close the bypassdamper. With the use of the small damper handle.
2. Shut off the water supply to the humidifier by closing the sad­dle valve.
Humidifier Control:
There is no adjustment to the Humidifier Control required for summer shutdown. (Applies to both Automatic and Manual Mode.)
VI. PERIODIC PREVENTATIVE MAINTENANCE
NOTE: Periodic inspection and preventive maintenance of your total heating system is important for efficient and safe opera­tion. Your heating contractor should include humidifier service at the same time.
All models are equipped with an in-line water strainer and orifice as shown below. These parts should be inspected and cleaned periodi­cally to assure continued proper unit performance.
- 9 -
Page 11
IN-LINE
STRAINER
Inspection and Service Instructions
1. Disconnect electrical power to the furnace and shut off water supply.
OUTLET COMPRESSION NUT
ORIFICE
SOLENOID VALVE
INLET
INLET COMPRESSION NUT
2. Disconnect the water line at the inlet compression nut.
3. Remove the in-line strainer from inside the inlet side of the valve by using a small nail or wire.
4. Flush the in-line strainer clean or replace with a new strainer, Service Department, Part No. 4004.
5. Replace the in-line strainer and reconnect the inlet water line (Double Wrench To Prevent Leaking).
6. Disconnect the water line at the outlet compression nut.
7. Remove the orifice from the copper or plastic tube and make sure this small opening is unplugged.
8. Replace the orifice and reconnect the outlet water line (Double Wrench To Prevent Leaking).
9. Turn on water supply and reconnect electrical power to the furnace.
- 10 -
Page 12
MAINTENANCE INSTRUCTIONS
for
APRILAIRE HUMIDIFIER MODEL
WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing.
1. Front Cover
2. Feed Tube
3. Integral Damper
4. Water Panel Evaporator Assembly
5. Distribution Tray
6. “V” Notches
7. Water Panel
8. Scale Control Insert/ Float Chamber
9. Overflow Hose
10. Float Cover
11. Float
12. Water Level Sensor Assembly
MODEL
400
400
MODEL 400
1. Note humidistat or control setting and turn dial to the “Off” position.
2. Turn off water supply. Turn the damper (3) to the SUMMER position.
3. Press the tabs in the latches on the top and bottom of front cover (1) and pull cover off base with both hands.
4. Carefully pull the plastic feed tube (2) out of the distribution tray (5) at the top of the Water Panel evaporator assembly (4). Tip the water panel evaporator assembly forward and lift it out of the humidifier. Do not tip the water panel evaporator assembly more than needed to clear the housing to avoid over-bending the water level sensor assem­bly (12).
5. Unsnap the distribution tray from the scale control insert (8). Lightly scrape out any cal­cium deposits and clean the “V” notches (6) but do not scrape off the granular coating. This textured surface helps ensure even water flow for maximum performance. See page 2 if removed.
6. Slide the used water panel (7) out of the scale control insert/float chamber and dispose of the water panel. Inspect the overflow hose (9) to make sure it is open.
7. Remove the float cover (10) and inspect the floats (11) and float chamber for mineral build-up. Remove deposits as needed from floats, float chamber and scale control insert. Wash the parts with a disinfecting cleaner. Reassemble the floats and float cover. Make sure stems of both floats extend through openings in float cover and that floats move freely up and down.
8. Slide a new Aprilaire no. 45 water panel into the scale control insert/float chamber. Snap the distribution tray back on the scale control insert.
9. Reinstall the water panel evaporator assembly into the humidifier. Take care not to over-bend the water level sensor assembly. Push the top of the water panel evaporator assembly firmly back until it snaps into place.
10. Push the end of the feed tube back firmly into the distribution tray. Reset the damper to desired position. Replace the front cover.
11. Turn on the water supply.
12. Reset humidistat control to its original position. Check operation.
- 11 -
Page 13
MAINTENANCE INSTRUCTIONS
for
APRILAIRE HUMIDIFIER MODEL 600
CAUTION! Sudden operation may cause personal injury or property damage. Turn humidistat or control to “off” or lowest setting before servicing.
1. Front Cover
2. Feed Tube
3. Integral Damper
4. Water Panel
MODEL 600
Evaporator Assembly
5. Distribution Tray
6. “V” Notches
7. Water Panel
8. Scale Control Insert
9. Drain Hose
1.
Note humidistat or control setting and turn dial to the “OFF” position.
2. Turn off water supply.
3. Press the tabs in the latches on the top and bottom of front cover (1) and pull cover off base with both hands. Set aside.
4. Carefully pull the plastic feed tube (2) out of the distribution tray (5) at the top of the Water Panel evaporator assembly (4). Pull this assembly out by grasping at top and tipping out.
5. Remove the black distribution tray (5) from the water panel evaporator assembly by lifting straight up from the scale control insert (8). Lightly scrape out any calcium deposits and clean the “V” notches (6) but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance. See page 2 if removed.
6. Slide the Water Panel evaporator (7) out from the white plastic Scale Control Insert (8). Clean the insert frame of calcium deposits with a putty knife. Inspect Water Panel evap­orator (Stock No. 35 for Model 600) and substitute a new Genuine Aprilaire Water Panel if necessary. Slide the Water Panel back into the scale control insert with the black col­ored spot up and snap the black distribution tray back into place.
7. Re-install the Water Panel evaporator assembly into the unit by fitting its drain tube into the round receptacle at the base of the unit. Push the assembly in at the top against the beveled tabs that will hold it in place. Push the end of the feed tube back firmly into the distribution tray and replace the front cover.
8. Remove the drain hose (9) from the bottom of the unit and bend and flex it to loosen the internal calcium deposits. Then flush it with water under pressure and slip it back onto the drain fitting.
9. Turn on the water supply.
10.
Check system operation:
Humidifier Control: ting the knob to “Test.” With furnace blower operating and furnace calling for heat, humidifier will operate for one minute. DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE.
11. Set Humidifier Control to its original position.
(Automatic or Manual) Check system operation by set-
- 12 -
Page 14
MAINTENANCE INSTRUCTIONS
for
APRILAIRE HUMIDIFIER MODEL 700
WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing.
5
2
3
4
1
1. Front Cover
2. Base
3. Water Panel Evaporator Assembly
4. Distribution Tray
5. ”V” Notches
6. Water Panel
7. Scale Control Insert
8. Drain Hose
9. Power Cord
6 7
8
9
1.
Note humidistat or control setting and turn dial to the “OFF” position.
2. Disconnect electrical power and turn off water supply.
3. Unlatch humidifier cover assembly (1) from base assembly (2) at the bottom of the cover, lift, and set aside.
4. Pull out the water panel evaporator assembly (3) by grasping at the top and tipping out.
5. Remove the black distribution tray (4) from the water panel evaporator assembly (3) by unsnapping the white plastic holding strips from the tabs at the end of the tray. Lightly scrape out any calcium deposits and clean the “V” notches (5) but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance.
6. Slide the Water Panel evaporator (6) out from the white plastic Scale Control Insert (7). Clean the deposits or use a putty knife. Inspect the Water Panel evaporator (Stock No. 35) and replace with a new Genuine Aprilaire Water Panel if necessary. Slide the Water Panel evaporator back into the scale control insert with the red colored spot up and snap the black distribution tray (4) back into place.
7. Re-install the water panel evaporator assembly (3) into the base assembly (2). Push it in at the top between the retaining ribs that hold the assembly in place in a vertical posi­tion.
8. Remove the drain hose (8) from the bottom of the unit. Bend and flex it to loosen the internal calcium deposits. Then flush it with water under pressure and slip it back onto the drain fitting.
9. Reinstall cover assembly (1) by hooking at the top of the base assembly (2) and latching at the bottom.
10. Reconnect electrical power (9) and turn on the water supply.
11.
Check system operation:
12.
Set Humidifier or control to its original position
Scale Control Insert
Humidifier Control: ting the knob to “Test.” With furnace blower operating and furnace calling for heat, humidifier will operate for one minute.
(Automatic or Manual) Check system operation by set-
by twisting and flexing it to loosen the calcium
.
MODEL 700
- 13 -
Page 15
LIMITED WARRANTY
Your Research Products Corporation Aprilaire®Humidifier unit is expressly warranted for one (1) year from date of instal­lation to be free from defects except, however, for the disposable water panel which will have to be replaced from time to time depending upon the amount of use.
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any part of the humidifier which is found to be defective within one (1) year period and which is returned not later than thirty (30) days after said one (1) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701, together with the model number, manufacturing code number and installation date of the humidifier.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE HUMIDIFIER ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID ONE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WAR­RANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of inciden­tal or consequential damages so the above exclusion or limitations may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
- 14 -
Page 16
The Aprilaire®Indoor Air Comfort System is an integrated group
THE BEST IN INDOOR AIR COMFORT
®
of air quality enhancement products designed to work with your heating and cooling system to make your home more comfortable. For the best in indoor air quality, ask your heating and cooling contractor about these fine Aprilaire products, or visit us
www.aprilaire.com to solve your Indoor Air Comfort needs.
at
Aprilaire
®
Automatic Humidifiers
The Best Cure For Dryness
The world’s first computer-equipped,
completely automatic humidifier.
®
Zone Control Systems
Custom Comfort Throughout Your Home
The most reliable way to achieve temperature
control in every area of your home.
High Efficiency Air Cleaners
Nobody Makes Clean Air Easier
Delivers the cleanest, healthiest air ever
available from a whole-house air cleaner.
Aprilaire
Aprilaire
®
®
®
®
Aprilaire
®
Energy Recovery Ventilator
Only The Freshest Homes
Have April Air
Your best value for a constant,
controlled supply of fresh air with
energy-recovery.
Aprilaire
®
Electronic Thermostats
Energy Efficiency Never
Looked So Good
Ultra-thin, easy-to-use digital,
programmable, and communicating
controls featuring pinpoint accuracy.
Page 17
SERVICE AND WATER PANEL
REPLACEMENT RECORD
Date
Dealer Name
Page 18
SERVICE AND WATER PANEL
REPLACEMENT RECORD
Date
Dealer Name
Page 19
P.O. BOX 1467 • MADISON, WI 53701-1467
Products For Better Indoor Air Quality
DP #10005406 Printed in U.S.A.
Loading...