Aprilaire 60, 62 User Manual

Page 1
Model 60 shown.
Automatic
Digital Humidifier Control
Model 60 &62
Safety and Installation Instructions
RE AD COMP L ETE INS TA L LATIO N IN S TRUC TION S
AN D TE MPLATE BEF ORE START I NG INSTAL L AT ION.
WARNING
ATTENTION INSTALLER: This product must be
installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.
Page 2
WARNING
1. 120/240 volts may cause serious injury from electrical shock. Disconnect electrical power to the furnace and humidifier before starting installation.
2. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling ductwork.
CAUTION
1. Do not set humidifier higher than recommended. Condensation damage may result.
2. Do not set humidity up to recommended levels if there is condensation on the inside of windows of any unheated living space. Condensation damage may result.
3. Do not mount the Humidifier Control on the supply plenum or duct. The unit cannot withstand the plenum temperatures and will malfunction.
4. When installing the Humidifier Control on a counterflow furnace, ensure the blower continues to run after the heat call is satisfied to eliminate high temperatures from damaging the Humidifier Control.
5. Do not mount the Humidifier Control downstream of the bypass outlet. False humidity conditions will cause the humidifier to operate incorrectly.
6. Avoid installing the Humidifier Control with the display facing downward to prevent the Humidifier Control from incorrectly measuring the relative humidity (RH) in the duct.
TABLE OF CONTENTS
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4
System Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 20
THESE INSTALLATION INSTRUCTIONS
ARE FOR THE APRILAIRE
HUMIDIFIER CONTROL ONLY!
For Aprilaire
follow Aprilaire Humidifier Installation Instructions.
®
AUTOMATIC DIGITAL
®
humidifier installation,
32
Page 3
Water Panel
Indicator
Settings
INSTALLATION
B
A
C
STEP 1: Unpack the Humidifier Control Carton
Make sure all components are present (see Figure A):
A. Humidifier Control B. Outdoor Temperature Sensor C. Manual Mode Label
Figure A
STEP 2: Disassemble the Humidifier Control
Remove the knob. Remove the cover by pulling at the bottom and swinging it out and upward.
STEP 3: Check the Change Water Panel Indicator Setting
This setting will control when the indicator light turns on, reminding you to change your water panel. If your Control came with a humidifier, the Control is pre-set for the humidifier. If the installation site has a 3-month or shorter heating season or very hard water, you may want to adjust the setting (see Figure B).
90-1201B
Figure B
Use the “OFF” setting for Model 800
Series humidifiers.
Use Setting “A”
for Model 400 Series humidifiers in areas with very hard water. The indicator will light after 150 hours of humidifier operation.
Use Setting “B”
for Model 400 Series, and for 500 Series, 600 Series and 700 Series humidifiers in areas with very hard water. The indicator will light after 300 hours of humidifier operation.
Use Setting “C” for Model 500 Series, 600 Series and 700 Series humidifiers. The indicator will light after 600 hours of
90-1202B
humidifier operation.
The Model 62 shipped with the Model 800 Steam Humidifier is factory set to “OFF”. The Model 62 does not have the “Change Water Panel” light on the Control. The Canister Change indicator for the Model 800 is on the humidifier.
54
Page 4
STEP 4: Determine Location for Humidifier Control
6" MIN.
RETURN
DUCT
HUMIDIFIER
CONTROL
FRESH AIR
INTAKE
COIL
HUMIDIFIER
BYPASS
CONNECTION
and Mount Control
Humidifier Control must be mounted on the Return Duct, at least 6 inches upstream of the following (see Figure C):
• Humidifier
• Humidifier Bypass Ductwork (if applicable)
• Fresh Air Intake Ductwork (if applicable)
Ambient operating temperature of the Humidifier Control is to be from 20°F to 120°F to prevent damage to the control display.
Figure C
90-1137
DUCT (SHEET METAL) MOUNT:
After location for Control is selected, drill a 3/4 inch hole for the RH sensor (the RH sensor extends from the back of the Humidifier Control).
Use 2 sheet metal screws, 3/4 inch long (not provided), to mount the Humidifier Control. Use the mounting slot to level the Control, then secure the Control with the second sheet metal screw.
Make sure the Humidifier Control sensor gasket is seated tightly around the drilled hole. Do not install Control without gasket.
DUCT (FIBER BOARD) MOUNT:
After location for Control is selected, cut a rectangular hole in the duct board, no smaller than 6-9/16 inches long by 4-3/8 inches wide.
Cut a rectangular piece of sheet metal to fit behind the hole in duct board for mounting the Humidifier Control.
Drill a 3/4 inch hole for the RH sensor (the RH sensor extends from the back of the Humidifier Control) into the sheet metal plate.
Use 2 sheet metal screws, 3/4 inch long (not provided), to mount the Humidifier Control.
Make sure the Humidifier Control sensor gasket is seated tightly around the drilled hole. Do Not Install Control Without Gasket.
Secure the sheet metal plate, with the Humidifier Control mounted, inside the duct (see Figure D).
CONTROL REPLACEMENT:
When replacing an existing control, the duct opening left by the removed control must be covered completely. Locate and install the new control as instructed previously in Step 4.
76
Page 5
Figure D – Fiber Board Duct Mount
CONTROL BOARD
COVER
KNOB
BASE PLATE
RETURN DUCT
RETURN
DUCT
SHEET METAL
PLATE
CUT OPENING IN RETURN DUCT
SHEET METAL PLATE
GASKET
SCREW (x2)
INSIDE OF
RETURN
DUCT
HHGfW GODTBACR
OUTDOOR
TEMPERATURE
SENSOR
24 VAC FROM
HVAC EQUIPMENT
“R” AND “C”
COMMUNICATION
WITH APRILAIRE
8570 THERMOSTAT
HEAT SIGNAL
FROM HVAC EQUIPMENT
FAN SIGNAL
FROM
THERMOSTAT
SOLENOID
CONTROL
OUTPUT
FAN SIGNAL
TO HVAC
EQUIPMENT
Figure E – Digital Humidifier Control 24V Terminals
90-1203B
90-1397B
98
Page 6
3 FEET MAX.
CENTER LINE
OUTSIDE WALL
STEP 5: Determine Location for Outdoor Temperature Sensor
The location of the Outdoor Temperature Sensor must meet these three requirements:
1. Must be mounted on North, East or West side of house out of direct sunlight.
2. Must be at least 3 feet from all exhaust vents.
3. Must be above expected snow line (see Figure F).
Incorrect humidity levels will result if these requirements are not met.
Figure F
OUTDOOR
TEMPERATURE SENSOR
LEADS
NORTH, EAST OR WEST SIDE OF HOME
ABOVE EXPECTED
SNOW LINE
OUTDOOR
TEMPERATURE
SENSOR
SENSOR
BRACKET
SENSOR
90-998
STEP 6: Locate Existing Access Hole to Outside
A convenient way to get the Sensor wire outside is to make use of unused wires running to the A/C condensing unit (if applicable). Other ways are to use existing holes for Cable TV lines, telephone lines, A/C lines, etc. Read all equipment instructions beforehand for possible conflicts and warnings.
STEP 7: Alternate Location for Outdoor Temperature Sensor
WARNING
If Outdoor Temperature Sensor is mounted in an intake duct or pipe, do not set Blower Activation switch to “ON”.
The Sensor can also be mounted in the center of either:
• PVC fresh air intake pipe for the HVAC system
OR
• fresh air intake duct. Mount the sensor with a #8 galvanized screw.
In both cases, the Sensor must be no more than 3 feet from the outside wall. See Figure G.
If it is not feasible to use the Outdoor Temperature Sensor in any of the ways described, the Humidifier Control can be installed for Manual Operation. See “Installing the Humidifier Control for Manual Operation” and Figure J for details.
Figure G
90-999
1110
Page 7
STEP 8: Route the Wire from Control to Sensor
Run wire to the outdoor temperature sensor. Sensor is not affected by lead lengths less than 300 feet.
CAUTION
Do not run outdoor temperature sensor alongside wires carrying high voltage (120 VAC or higher).
Secure the sensor bracket with a #8 screw.
STEP 9: Attach Sensor Wire to Humidifier Control
Strip wire 1/4 inch, and insert the wires from the Sensor into the terminals labeled “ODT” on the Humidifier Control. See Figure H for location of terminals.
Figure H
90-1219B
BLOWER ACTIVATION
Set the Blower Activation Switch to “ON” to allow the Humidifier Control to activate the furnace fan for additional humidification. This may be required if the humidifier is mounted on a heat pump or a furnace with short run cycles.
When the Blower Activation switch is “ON”, the Humidifier Control will turn on the HVAC blower when humidity is required. In the “OFF” position, the humidifier will only operate if humidity is required and the HVAC system is operating.
When the Blower Activation switch is “ON”, the Humidifier Control may periodically turn the HVAC blower on to sample the humidity of the air.
Installing the Humidifier Control for Manual Operation
If it is not feasible to install the Outdoor Temperature Sensor, the Humidifier Control can be operated in Manual Mode.
1. Position the Mode Switch in the “MAN” position. Manual indicator “M” will be displayed.
2. Apply the Manual Mode Label to the cover, aligning the sticker and knob holes.
Figure J
90-1236B
1312
Page 8
G
Y
W
C
R
THERMOSTAT
120 VAC
R
C
W
Y
G
FURNACE
OUTDOOR
TEMPERATURE
SENSOR FOR AUTOMATIC
MODE
NORTH, EAST
OR WEST SIDE
OF HOME
ABOVE EXPECTED
SNOW LINE
CONTINUOUSLYPOWERED
24 VAC TRANSFORMER
PROVIDED WITH HUMIDIFIER
CONNECT
TO HOT WATER
SUPPLY
CONNECT DRAIN LINE HERE
OUTPUTSINPUTSPOWER
GW
CRHHODT GfA
ADHC TERMINAL STRIP
B
STEP 10: Model 60 Wiring for Model 400, 500, 600 and
700 Series Humidifiers – See Figure K
WARNING
120 volts may cause serious injury from electrical shock. Disconnect electrical power to the furnace before starting installation.
Strip the wires used for all Humidifier Control terminal connections 1/4 inch.
NOTES:
• The Model 60 must be continuously powered from “R” and “C” on the furnace to function properly.
• The minimum VA required is 2.0 VA.
• In order for the humidifier to operate, the HVAC blower must be running and the Model 60 must be calling for humidity.
WIRING DESCRIPTION:
• Wire external 24 VAC transformer into a constant power source other than the heating, ventilating, air conditioning equipment
120 VAC line at the junction box before it enters the HVAC equipment. Connect the 24 volt side of the transformer to one of the “H” terminals on the humidifier control and to one of the humidifier solenoid valve wires. Connect the other solenoid
(HVAC) blower circuit. The transformer can be powered off the
valve wire to the other “H” terminal.
• Wire “R” and “C” on the Model 60 to “R” and “C” on the furnace terminal strip.
• Remove the thermostat “G” wire from the furnace terminal strip and wire it to “G” on the Model 60 control.
• Wire “Gf” on the Model 60 to “G” on the furnace terminal strip.
• Wire “W” on the Model 60 to “W” on the furnace terminal strip.
• Replace cover and knob.
Figure K – Model 60 Wiring for Model 400, 500, 600 and 700 Series Humidifiers
90-1510
1514
Page 9
OUTPUTSINPUTSPOWER
G
W
C
RHHODT GfA
ADHC TERMINAL STRIP
B
MODEL 800
STEAM HUMIDIFIER
OUTDOOR TEMPERATURESENSOR
FOR AUTOMATICMODE
FURNACE
THERMOSTAT
R
C
W
Y
G
G
Y
W
C
R
STEP 11: Model 62 Wiring for Model 800 Series Steam
Humidifier – See Figure L
WARNING
120/240 volts may cause serious injury from electrical shock. Disconnect electrical power to the furnace and humidifier before starting installation.
Strip the wires used for all Humidifier Control terminal connections 1/4 inch.
NOTES:
• The Model 62 must be continuously powered from “R” and “C” on the furnace to function properly.
• The minimum VA required is 2.0 VA.
• In order for the humidifier to operate, the HVAC blower must be running and the Model 62 must be calling for humidity.
WIRING DESCRIPTION:
• Wire “H” terminals on the Model 62 to the “Humidifier” terminals on the Model 800 control board.
• Wire “R” and “C” on the Model 62 to “R” and “C” on the furnace terminal strip.
• Remove the thermostat “G” wire from the furnace terminal strip and wire it to “G” on the Model 62 control.
• Wire “Gf” on the Model 62 to “G” on the furnace terminal strip.
• Wire “W” on the Model 62 to “W” on the furnace terminal strip.
• Replace cover and knob.
Figure L – Model 62 Wiring for Model 800 Series Steam Humidifier
90-1511
1716
Page 10
SYSTEM CHECKOUT
1. Replace the cover by snapping it into the Humidifier Control
base. Also replace the knob onto the Control.
2. Turn Blower Activation switch to OFF
3. Restore power to the HVAC system.
4. Activate the HVAC system or heat pump (Fan or Heat).
5. Once the blower is operating, rotate the knob of the
Humidifier Control Clockwise to the “Test/Reset” position. When the knob is set in the “Test/Reset” position, the green “Humidifier On” light will illuminate. After 5 seconds, the green “Humidifier On” light will blink, indicating a system reset.
6. If the Humidifier Control and humidifier are set up properly,
you should hear the solenoid valve click into the open position. On the Model 800 Steam Humidifier, the “Steam” light will illuminate green. In the “Test/Reset” position, the humidifier will operate for 1 minute. If the Humidifier Control is left in the “Test/Reset” position for more than 1 minute, the “H” terminals will open (closing the solenoid valve), and the knob and display backlights will flash, indicating that the Humidifier Control is still in the “Test/Reset” position.
7. If the humidifier does not activate with the Humidifier Control
in the “Test/Reset” position, refer to the troubleshooting guide.
Blower Activation Test
• Deactivate HVAC system or heat pump.
• Turn knob to OFF.
• Set switch to Blower Activation ON.
• Turn the knob to Test/Reset. The Humidifier On light will illuminate. After 5 seconds, the green “Humidifier On” light will blink, indicating a system reset.
• If the Humidifier Control and humidifier are set up properly, the solenoid valve should click and the HVAC blower should activate.
• If the humidifier does not activate with the Humidifier Control in the “Test/Reset” position, refer to the troubleshooting guide.
• If HVAC blower does not activate with the Humidifier Control in the "Test/Reset" position, refer to the troubleshooting guide.
8. Setting the Humidifier Control:
• If the home is occupied, set the Humidifier Control to “Normal”. (For Manual Mode, set to 35%.)
• If the home is vacant, set the Humidifier Control to “OFF”.
• If in Manual Mode and system is installed during cooling season, set the Humidifier Control to “OFF”.
9. Instruct the homeowner to refer to the Aprilaire Owner’s Manual for the initial adjustment period.
10. Make sure the red “Call Dealer for Service” light is not flashing. If the red “Call Dealer for Service” light is flashing, refer to the troubleshooting guide.
1918
Page 11
TROUBLESHOOTING GUIDE
SYMPTOM
Call Dealer For Service Light Flashing (see Figure M).
TROUBLESHOOTING PROCEDURE
Applies to both Automatic and Manual Operation unless indicated otherwise.
Display Error Code: E1: RH Sensor
Rotate Humidifier Control knob to the “Test/Reset” position. After 5 seconds, the green “Humidifier On” light will blink, resetting the error. If E1 returns, replace the Humidifier Control.
Display Error Code: E2: Control Knob
Rotate Humidifier Control knob to the “Test/Reset” position. After 5 seconds, the green “Humidifier On” light will blink, resetting the error. If E2 returns, replace the Humidifier Control.
Display Error Code: E3: Outdoor Temperature Sensor
Auto Mode (switch in “AUTO” position)
1. Make sure that the Outdoor Temperature Sensor is properly connected to the ODT terminals on the Humidifier Control.
2. Measure the resistance of the Outdoor Temperature Sensor by removing the leads from the Humidifier Control terminals and measuring the resistance across the wires with an ohmmeter. Confirm the reading with the temperature in Table 1 on page 22. Reconnect the ODT Sensor leads. If the resistance value does not match the temperature value, replace the Outdoor Temperature Sensor.
TROUBLESHOOTING PROCEDURE (CONTINUED)
3. Rotate Humidifier Control knob to the “Test/Reset” position. After 5 seconds, the green “Humidifier On” light will blink, resetting the error. If E3 returns, replace the Humidifier Control.
Manual Mode (switch in “MAN” position)
1. Make sure the ODT terminals are clear of any wires that may short the terminals together other than the ODT sensor.
2. Rotate Humidifier Control knob to the “Test/Reset” position. After 5 seconds, the green “Humidifier On” light will blink, resetting the error. If E3 returns, replace the Humidifier Control.
Display Error Code: E4: Communication
This error applies to systems wired to an Aprilaire Model 8570 Thermostat (see Figure Q) using the “A” and “B” terminals. Rotate the Humidifier Control knob to the “Test/Reset” position. After 5 seconds, the green “Humidifier On” light will blink, resetting the error. If E4 returns, check the wiring between the Digital Humidifier Control and Model 8570 check the connections at “A”and “B” on the humidifier control and the Model 8570. Make sure the Model 8570 is wired and operating properly according to the Model 8570 manual.
2120
Page 12
TABLE 1
Red “Call Dealer For Service” Light
Yellow “Change Water Panel” Light
Green “Humidifier On” Light
Outdoor Temperature (°F) Resistance (
-30 231.8
-20 163.4
-10 117.3 0 84.8
10 62.2 20 46.1 30 34.4 40 26.1 50 19.9 60 15.3 70 11.9 80 9.3 90 7.3
100 5.8
Figure M
90-1227
k) ±10
SYMPTOM
Humidifier does not operate in “Test/Reset” mode.
TROUBLESHOOTING PROCEDURE
• Check wiring diagrams for correct Humidifier Control installation
• Make sure that the blower is operating and the HVAC system is calling for heat.
• Check wiring diagrams for correct Humidifier Control installation.
• If connected to a Model 400 Series humidifier, make sure both floats in the bottom of the scale control insert are in the down position. If necessary, dump out water to lower the floats.
• Check voltage at the Humidifier Control “R” and “C” terminals. Voltage should be 22 VAC minimum to 30 VAC maximum.
• Make sure that the saddle valve is open.
• In “Test/Reset mode, the humidifier will operate for 1 minute only. DO NOT LEAVE THE HUMIDIFIER CONTROL IN “TEST/RESET” MODE AS THE HUMIDIFIER WILL NOT OPERATE.
2322
Page 13
SYMPTOM
Yellow “Change Water Panel” light is blinking (see Figure M).
TROUBLESHOOTING PROCEDURE
Check the condition of the Water Panel and replace it if mineral deposits are blocking air flow. Follow the instructions on the Water Panel box. Rotate the knob to the “Test/Reset” position for at least 5 seconds to reset Water Panel change timer. Check that the timer setting is correct for the humidifier model and water conditions (see Figure B). DO NOT LEAVE THE HUMIDIFIER CONTROL IN “TEST/RESET” MODE AS THE HUMIDIFIER WILL NOT OPERATE.
SYMPTOM
Humidifier operates only in “Test/Reset” mode.
• If outdoor temperature is greater than 60°F or less than
-30°F, the Humidifier Control will only operate in the “Test/Reset” mode (for 1 minute).
• If the humidity level in the home is higher than the Humidifier Control knob setting, the Humidifier Control will not operate the humidifier.
TROUBLESHOOTING PROCEDURE
• Measure the resistance of the Outdoor Temperature Sensor by removing the leads from the Humidifier Control terminals and measuring the resistance across the wires with an ohmmeter. Confirm the reading with the temperature in Table 1. Reconnect the ODT Sensor leads. If the resistance value does not match the temperature value, replace the Outdoor Temperature Sensor.
• Make sure that the Outdoor Temperature Sensor is mounted completely outside the house on the North, East or West side of the house and out of direct sunlight. (Automatic Mode Only)
• Make sure that the Outdoor Temperature Sensor is located at least 3 feet away from all exhaust vents. (Automatic Mode Only)
• If Outdoor Temperature Sensor is mounted in the fresh air intake duct, make sure that the sensor is no more than 3 feet from the outside wall. (Automatic Mode Only)
2524
Page 14
SYMPTOM
Humidifier operates constantly.
• If the humidity level in the home is less than the Humidifier Control knob setting and there is a continuous fan call or heat call (depending on setup), the Humidifier Control will operate the humidifier until the humidity level is higher than the Humidifier Control knob setting.
TROUBLESHOOTING PROCEDURE
• Set Blower Activation switch to OFF.
• In the “Test/Reset” mode, verify that the humidifier turns off after 1 minute.
• Check the Outdoor Temperature Sensor resistance and location, as instructed on the previous page.
• Rotate the Humidifier Control knob counterclockwise to the “Off” position, and observe whether the humidifier turns off. If the humidifier still operates in the “Off” position, perform the following:
1. Check the wiring diagram for correct Humidifier Control
Installation.
2. Remove the wires from the “H” terminals on the
Humidifier Control. If the humidifier continues to operate, replace the solenoid valve.
SYMPTOM
Humidifier or Humidifier Control “chatters” or clicks On and Off rapidly.
TROUBLESHOOTING PROCEDURE
• Check for steady 22 VAC to 30 VAC across the “R” and “C” terminals of the Humidifier Control with a voltmeter.
• Check, with a voltmeter, that the HVAC signal across the “W” and “C” and “G and C” terminals of the Humidifier Control is a steady 22 VAC to 30 VAC.
• Make sure that the Outdoor Temperature Sensor wiring is not running alongside other wires carrying high voltage (120 VAC or higher). (Automatic Mode Only)
SYMPTOM
Humidifier blower does not activate during Blower Activation Test.
TROUBLESHOOTING PROCEDURE
• Set the Blower Activation Switch to “ON”.
• Check wiring diagrams for correct Humidifier Control installation.
2726
Page 15
RESEARCH PRODUCTS CORPORATION
P.O. BOX 1467 • MADISON,WI 53701-1467
Call 800/334-6011 • FAX 608/257-4357
28
10008977 6.10
B2205119A
Loading...