The APC™ by Schneider Electric Smart-UPS™ is a high performance uninterruptible power suppl y (UPS). The
UPS provides protection for elec tronic equipment fro m u tility power blackouts, brownouts, sags, and sur ges , small
utility power fluc tuations and large disturbances. The UPS also provides battery backup power for connected
equipment until utility power returns to safe levels or the batteries are fully discharged.
This user manual is available on the enclosed CD and on the APC by Schneider Electric Web site, www.apc.com.
Important Safety Messages
Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or
maintain it. The f ollowing special message s may appear throughout this manua l or on the equipment to warn of
potential hazards or to call attention to information that clarifies or simplifies a procedure .
The addition of this sym bol to a Caut ion produc t safe ty label indi cate s that a hazard exist s tha t
can result in injury and product damage if the instructions are not followed.
The following safety messages may appear throughout this manual to warn of potential
hazards.
CAUTION
CAUTION indicates a potentially ha zardous situation which, if not av oided, can result in equipment damage and minor or
moderate injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage.
Safety and General Information
Inspect the package contents upon receipt. Notify the carrier and dealer if there is any
damage.
Read the Safety Guide supplied with this unit before installing the UPS.
• Adhere to all local and national electric al codes.
• This UPS is intended for indoor use only .
• Do not operate this UPS in dire ct sunlight, in contact with fluids, or where there is excessive dust or
humidity.
• Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventil ation.
• The battery typic ally la sts for two to f ive year s. Environ menta l fact ors impac t batte ry life. Eleva ted ambie nt
temperatures, poor quality utility power, and frequent short duration discharge s will shorten battery life.
• Connect the UPS power cabl e directly to a wall outlet. Do not use surge protector s or extension cords.
1Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U
Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U2
Specifications
Environmental Specifications
For additional specifications, refer to the APC by Schneider Electric Web site at www.apc.com.
Temperature
Maximum
Elevation
Humidity
Operating0° to 40° C (32° to 104° F)
Storage
Operating3,000 m (10,000 ft)
Storage15,000 m (50,000 ft)
0% to 95% relative humidity, non-condensing
Installation
UPS
For UPS installation information, refer to the Smart-UPS X Installation Guide that is included with the
UPS. The guide is also avail able on the enclosed CD and the APC by Schneider E lec tric Web site at
www.apc.com.
Network Management Card
For installation information, refer to the user manual provided with the Network Management Card
(NMC). The user manual is also available on the APC by Schneider Electric Web site at
www.apc.com.
-15° to 45° C (5° to 113° F)
charge UPS battery every six months
External Battery Pack
For installation info rmation, refer to the SMX48RMBP2U external ba ttery p ack Insta llation Gu ide that
is included with th e external batter y pack (XLBP). The guid e is also av ailable on the enclosed CD and
the APC by Schneider Electric Web site at www.apc.com.
3Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U
Operation
Connect Equipment to the UPS
CAUTION
RISK OF EQUIPMENT DAMAGE
• Adhere to all local and national electrical codes.
• Wiring should be performed by qualified electrician.
• Always connect the UPS to a grounde d outlet.
Failure to follow these instructions can result in equipment damage
Note: The UPS will charge to 90% capacity in the first three hours of normal operation. Do not
expect full battery runtime capability during this initial charge period.
1. Connect equipment to the outlets on the rear panel of the UPS.
2. Connect the UPS to the building utility power.
Always connect the UPS to a two pole, three wire, grounded source.
3. To use the UPS as a master
4. Press the
5. See “Control lable Outlet Groups” o n page 8 for informatio n on how to use the Controllable Outlet Groups.
ON/OFF button on the front panel of the UPS to turn on the UPS and all connected equip me nt.
ON/OFF switch, turn on all the equipment that is connected to the UPS.
Basic Co nn e ctors
Serial port: Connect to a co mpu ter to use power management software.
USB port: Connect to a computer to use power management software.
Note: Serial and USB communication can not be used simultaneously.
Externa l Bat tery Pa ck co nn ec to r: Connect external battery packs to provide extended runtime
during power outages. The UPS can support up to five external battery packs.
Ground Screw: The UPS features a ground screw for connecting the ground lead on surge
suppression devices suc h as a telephone and network line protectors. When connecting a ground
cable, disconnect the UPS from utility power.
su0439a
Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U4
Display Panel
su0343a
A
Electric
Overview
Online LED
1
UPS Output On/Off button
2
On Battery LED
3
Site Wiring Fault LED
4
Replace Battery LED
5
Display screen
6
UP/DOWN arrow buttons
7
ENTER button
8
ESCAPE button
9
Using the display interface
Use the UP/DOWN arrow button s to scrol l th rough the mai n menu op tions . Press ENTERto view the subm enus und er
each main menu option. Press
ESCAPE to exit a submenu and return to a main menu.
PC by Schneider
Standard menus
The Standard menus are the most commonly used menus for the UPS.
MenuGeneral Functions
View basic information about the UPS:
• Operating mode
• Switched Outle t s tatus, On or Off
• Efficiency of the UPS
• Information about the load
Status
Configuration
Test & DiagsUse the Test & Diags menu to have the UPS perform a self-test.
• Batter y capacity
• Estim ated runtime
• Input and output voltage and frequency
• Information about the last transfe r to battery power
• Self-test results
• SmartSlot Card information
Configure the settings for the UPS:
• Language
• Local power quali ty: Good, Fair, P oor
• Choose Standa rd or Advanced menus
• UPS Test settings
• Reset to Factory Defaults
About
Display information about this unit:
• Unit model number
• Serial num b er
• Battery information
•Model number
•Installation date
•Suggested batt ery replacement date
•UPS firmware version
5Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U