Product data sheet
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Characteristics
BX750MI-FR
APC Back-UPS 750VA, 230V, AVR, French
Sockets
Overview
Lead time Usually in Stock
General
Provided equipment User manual
Max runtime 120Min
Number of tare power 21W
Number of power module free slots 0
Number of power module filled slots 0
Redundant No
UPS size WS
Physical
Cable length 1.22M
Colour Black
Depth 36Cm
Height 16Cm
Mounting preference No preference
Net weight 5.4Kg
Mounting mode Not rack-mountable
Two post mountable 0
USB compatible No
Width 12Cm
Input
Network frequency 50/60 Hz +/- 5 Hz auto-sensing
Input voltage limits 140...300 V
Number of cables 1
Input voltage 230 V
Cos phi 0.63
13-Apr-2021
1
Output
Rated power in W 410W
Maximum configurable power in W 410W
Output frequency 50/60 Hz +/- 1 Hz sync to mains
UPS type Line interactive
Wave type Stepped approximation to a sinewave
Nb of power socket outlets 3 French
Curve equation Efficiency
Curve fixed loss 0.0307
Curve load maximum 100%
Curve load minimum 4%
Curve proportional loss 0
Curve square loss 0.0019
Curve X-axis maximum 100%
Curve test cond ID Curve fit of data measured in accordance with the ENERGY STAR Test Method-
Curve X-axis minimum 0%
Curve X-axis title Load
Curve X-axis units Percentage
Curve Y-axis maximum 100%
Curve Y-axis minimum 50%
Curve Y-axis title Efficiency
Curve Y-axis units Percentage
Full load runtime 00:01:00 390 W
Graph display 1
Half load runtime 00:08:30 195 W
Output voltage 230 V
Maximum configurable power in VA 750VA
Rated power in VA 750VA
Transfer time 6 ms typical : 10 ms maximum
for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF = 1.0) output.
Conformance
Product certifications CE
Standards EN/IEC 62040-1
Equipment protection policy Lifetime : 50000 euros
CB
EN/IEC 62040-2
CE
Environmental
Ambient air temperature for operation 0…40°C
Relative humidity 0…95% non-condensing
Operating altitude 0...3000 m
Ambient air temperature for storage -15…40°C
Storage Relative Humidity Non-condensing 0…95%
Storage altitude 0…3000M
Acoustic level 40 dBA
Show note OP temperature No
IP degree of protection IP20
2