– Direct sunlight
– Excessive heat
– Excessive humidity or contact with fluids
Battery Backup Surge Protection
These outlets are powered whenever the Back-UPS is switched
ON. During a power outage, or ot her utility pro blems (brow nouts,
over-voltages), these outle ts will be powered fo r a limited ti me by
the Back-UPS. Plug the computer and monitor into these two
outlets.
Connect AC Power Cord
Plug the Back-UPS power cord into a wall outlet, not a surge
protector or power strip. The outlet should be nea r the equipment
and easily accessible.
Connect the Battery and Turn on the Unit
Connect the battery to the UPS before use. To connect the battery:
Pull the top of the battery connector lever out of the unit, until the lever is horizontal.
Push the battery c onn ec tor lev er co mp let ely i nto the unit, until the end of th e l ev er is flush with the rear panel.
Press ON/OFF to turn on the unit.
A single short beep, and the gree n “Powe r On” indic at or co nfirm s that th e Back -UPS is on and ready to pro vide
protection.
The Back-UPS should charge for at least 10 hours to ensure sufficient runtime. The unit is being charged
whenever it is connected to utility power, whether the unit is turned ON or OFF.
ON/OFF and
LED Stat us
Indicator
Battery backup and
surge protected outlets
bu054a
bu053a
3
Adjusting Transfer
Voltage and Sensitivity
Settings
Automatic Voltage Regulation boosts th e utility voltage
when it drops below safe levels. This allows the
equipment plugged into the unit to operate during low
voltage condi tions, conserv ing the b attery p ower i n the
event of a power outage.
The Back-UPS will switch to battery power if the input
voltage level becomes too low for the Automatic
Voltage Regulation to compensate, or if the utility
power is distorted.
If the Back-UPS switches to battery power too
frequently or too infrequently, adjust the transfer
voltage and sensitivity settings:
1. Ensure the Back-UPS is of f. Plug it into u tility
power.
2. Press and hold ON/ OFF u ntil t he LED repe atedly
flashes. The unit is now in Program Mode.
3. Release the butt on. The L ED wil l flas h once,
twice, or three times per second, indicating the
current setting. See Transfer Voltage and Sensitivity Settings.
4. Press ON/OFF with in two se conds to c hange the
setting. Each time the button is pres sed, th e LED
will flash at a different rate: once, twice, or three
times per second, indicating the new setting.
Continue pressing the button unti l the desired
setting is reached. If the button is not pressed
within five seconds, the Back-UPS will exit the
Program Mode.
5. To exit Program Mode, re lease th e b utton and
wait for the LED to stop flashing.
Status Indicators
The Back-UPS indicates its operating status using a combination of visual and audible indicators.
Power On LED BuzzerCondition
OnOffOn-line - Back-UPS is supplying conditioned utility power
to the connected equipment
On (Off during 4
beeps)
FlashingRapid Beeping
FlashingConstant toneBad Battery Detected - Battery needs to be charged, or is
(factory default)
High165 - 270The Back-UPS will switch to battery power during any small fluctuation in voltage.
Range
(For Utility
Operation)
Usage
sensitive to low or high level voltage levels or minor voltage waveform distortions.
Use with equipment that is sensitive to low or high level voltage levels or minor
voltage waveform distortions.
APC, Back-UPS and PowerChute are registered trademarks of Am erican Power Conversion Corp.
All other trademarks are property of their respective owners.
Troubleshooting
ProblemProbable CauseSolution
Back-UPS will not turn on.Circuit Breaker has tripped.Reduce the amount of equipment plugged into the “Battery Backup + Surge Protection”
outlets. Reset the circuit breaker by pushing it back in.
Utility power is not available at the wall
outlet.
Connected equipment loses
power.
The ON/OFF button is lit, and
the unit is beeping four times
every 30 seconds, or it is
emitting a constant tone.
The On/Off button flashes once
per second, and the Back-UPS
beeps once per second at the
same time.
Inadequate runtime.The battery is not fully charged.Allow the unit to charge by leaving it plugged in, and switched on for 10 hours .
The Back-UPS is overloaded.Ensure the equipment plugged into the outlets of the unit are not overloading the capacity
The Back-UPS has exhausted its available
battery pow er.
The equipment connected to the Back-UPS
does not accept the step-approximated sine
waveform from the unit.
The Back-UPS may require service.Contact APC Technical Support for further troubleshooting.
The unit is using battery.The unit is operating normally and using battery power. Save any current work, turn off all
Battery capacity is low (there is about 2
minutes of use remaining).
The battery is near the end of useful life.As a battery ages, the amount of runtime available will decrease. Batteries also age
Ensure the fuse or circuit breaker for the wall outlet is okay, and the wall switch controlling
the wall outlet (if any) is in the ON position.
of the unit. Try disconnecting some of the equipment one device at a time, and see if the
problem continues.
The unit can only operate on battery power for a limited amount of time. The unit will
eventually turn off when the available battery power has been used. Allow the unit to
recharge for 10 hours before continuing to use the unit.
The output waveform is designed for computers and computer-related equipment. It is not
designed for use with motor- type equipment.
equipment, and turn the unit OFF. Once normal power is restored, turn the unit back ON,
and turn on all equipment.
The unit is about to shut down due to a low battery charge condition! When the unit beeps
once every second, the battery has about 2 minutes of power remaining. Immediately
power down your computer , and turn the unit OFF. When power returns to normal, the unit
will recharge the battery.
prematurely if the unit is placed near excessive heat. If the battery will not charge, the
Back-UPS is no longer operable.
Frequency - On Battery50 Hz
Transfer Time50 Hz: 6ms typical, 10ms maximum
Protection and
Filter
BatteryType Maintenance free
PhysicalNet Weight5.4 kg
AC Surge ProtectionFull time, 273 joules
AC InputRe-settable circuit breaker
Average Life2 - 5 years depending on the number of discharge cycles and
Typical Recharge Time 10 Hours
Dimensions (H x W x D) 18.55 cm (H) x 11.5 cm (W) x 21.3 cm (D)
Operating Temperature0
Storage Temperature-15
Operating Relative
Humidity
Operating Elevation0 to 3000 m (0 to 10,000 ft)
±8% VAC, typical
(step-approximated sine wave)
±1 Hz, 60 Hz ±1 Hz
60 Hz: 5ms typical, 8ms maximum
environmental temperature
o
C to 40 oC (32 oF to 104 oF)
o
C to 45 oC (5 oF to 113 oF)
0 to 95% non-condensing
Battery Replacement
The battery in the Back-UPS 500 is not user-replaceable. Contac t APC Sale s and Tech nical Supp ort f or a
list of authorized service centers near you.
Warranty
The standard warranty is 2 years from the date of
purchase. The APC st andard proc edure is to repla ce t he
original unit with a factory reconditioned unit. APC will
ship the replacement unit once the defective unit is
received by the repair department or cross-ship upon the
provision of a valid credit card number. The customer
pays for shipping to APC, and APC pays ground freight
transportation costs back to the customer. Customers
who must have the original unit back due to assigned
asset tags and set depreciation schedules must declare
such a need at first c ontact with APC Technical Support.
Service
Please DO NOT RETURN Back-UPS to the place of purchase under any circumstances.
1. Consult the Troubleshooting section to eli minat e com mon proble ms.
2. If you still have problems or questions, please contact APC via the internet or at one of the phone numbers listed below.
3. Before contacting APC, please be sure to record the date purchased, UPS model, and serial number (on bottom of unit).
4. Be prepared to troubleshoot the problem over the telephone with a Technical Support Representative. If this is not successful, the representative will is su e a R e turn
Material Authorization Number (RMA#) and a shipping address.
5. Pack the unit in its or ig ina l p a ck ag ing . If the orig in al packaging is not available, ask APC Technical Support about obtaining a new set. Pack the uni t pro perly to avoid
damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty (insuring the package for full value is
recommended).
6. Write the RMA# on the outside of the package.
7. Return the unit by insured carrier to the address given to you by APC Technical Support.
– Nắng chiếu trực tiếp
– Nhiệt độ quá cao
– Độ ẩm quá cao hoặc tiếp xúc với các chất lỏng
Ắc quy Dự phòng Chống Sốc điện
Các ổ cắm này có điện bất cứ khi nào BẬT Back-UPS lên. Trong
lúc mất điện, hay khi có các trục trặc thực tế hay gặp khác (như
tụt áp, quá áp), Back-UPS sẽ cấp điện ra các ổ cắm này trong
khoảng thời gian có giới hạn. Cắm máy tính và màn hình vào
các ổ cắm này.
Nối Dây Nguồn AC
Cắm dây nguồn của Back-UPS vào ổ cắm điện trên tường,
không cắm vào bộ chống sốc điện hoặc ổ cắm rời. Ổ cắm nên ở
gần thiết bị và dễ cắm.
Nút ON/OFF
à Đèn LED
Báo Trạng thái
Nối Ắc quy vào và Bật Bộ Lưu điện lên
Nối ắc quy vào UPS trước khi sử dụng. Để nối ắc quy:
1 Kéo đầu cần nối ắc quy ra ngoài bộ lưu điện, cho đến khi cần nằm ngang.
2 Đẩy hết cần nối ắc quy vào trong bộ lưu điện, cho đến khi cán của nó ngang bằng với mặt sau.
Nhấn ON/OFF để bật bộ lưu điện.
Thiết bị phát ra một tiếng bíp ngắn, và đèn báo "Nguồn B
sàng hoạt động.
Back-UPS cần được sạc ít nhất 10 tiếng đồng hồ để đảm bảo đủ cấp điện. Bộ lưu điện được sạc bất cứ lúc nào
có nguồn điện cấp cho nó, cho dù đang BẬT hay TẮT.
ật" màu xanh cho biết rằng Back-UPS đã bật và sẵn
Các ổ cắm ắc quy dự
phòng và chống sốc điệ
bu054a
bu053a
3
Điều chỉnh Điện áp
Chuyển và Các Thiết
lập Độ nhạy
Ổn áp Tựđộng tăng điện áp hiệu dụng khi nó tụt dưới
mức an toàn. Điều này cho phép thiết bị cắm vào bộ
lưu điện tiếp tục vận hành trong suốt thời gian điện áp
thấp, bảo tồn nguồn ắc quy trong trường hợp mất điện.
The Back-UPS sẽ chuyển sang dùng nguồn ắc quy nếu điện áp ngõ vào quá thấp đến mức Ổn áp Tự
bù được, hoặc nếu nguồn hiệu dụng không ổn định.
Nếu Back-UPS chuyển sang nguồn ắc quy quá
thường xuyên hoặc ít khi, hãy điều chỉnh điện áp
chuyển và các thiết lập độ nhạy:
1. Hãy chắc chắn rằng Back-UPS đã tắt. Cắm nó
vào nguồn hiệu dụng.
2. Nhấn và giữ ON/OFF cho đến khi đèn LED
chớp liên lục. Bộ lưu điện bây giờ đang
độ Lập trình.
3. Thả nút ra. Đèn LED sẽ chớp một lần, hai lần,
hoặc ba lần mỗi giây, biểu thị thiết lập hiện hành.
Xem Điện áp Chuyển và Các Thiết lập Độ nhạy.
4. Nhấn ON/OFF trong vòng hai giây để thay đổi
thiết lập. Mỗi lần nhấn nút, đèn LED sẽ chớp với
một mức độ khác nhau: một lần, hai lần, hoặc ba
i giây, biểu thị thiết lập mới. Tiếp tục nhấn
lần mỗ
nút cho đến khi có được thiết lập theo ý muốn.
Nếu trong năm giây không nhấn nút, Back-UPS
sẽ thoát khỏi Chếđộ Lập trình.
5. Để thoát khỏi Chế độ Lập trình, hãy thả nút ra và
chờ cho đến khi đèn LED ngưng không chớp nữa.
động không
ở Chế
Các Chỉ thị Trạng thái
Back-UPS biểu thị tình trạng hoạt động của nó bằng cách sử dụng kết hợp các chỉ thị nghe và nhìn.
Đèn LED Nguồn Âm báoTình trạng
BậtTắtĐiện lưới - Back-UPS đang cấp điện nguồn hiệu dụng công
suất cho thiết bị kết nối
Bật (Tắt trong suốt
4 tiếng bíp)
Chớp liên tụcTiếng bíp phát
Chớp liên tụcTông đềuPhát hiện Ắc quy Không Ổn - Ắc quy cần được sạc, hoặc
TắtTiếng bíp ngắn
TắtTông đềuQuá tải ở Chế độ dùng Điện Ắc quy - Ắc quy của Back-
Bật Tông đều Quá tải ở Chế độ dùng Điện Lưới - Thiết bị kết nối tiêu
Chớp liên tục Kêu nhỏ mỗi 2 giâyCảnh báo Bộ sạc - Back-UPS có trục trặc bên trong, nhưng
T
ắtTông đềuLỗi Bộ sạc - Back-UPS có trục trặc bên trong, và không còn
4 tiếng bíp lặp lại
mỗi 30 giây
liên tục
(mỗi 1/2 giây)
mỗi 4 giây
Điện Ắc quy - Back-UPS đang cấp điện từ nguồn ắc quy
Cảnh báo Gần Hết Ắc quy - Back-UPS còn l
cấp điện
đã hết tuổi thọ. (Xem Thay Ắc quy.)
Ngắt nguồn Do Sắp hết Ắc quy - Trong suốt quá trình hoạt
động của Ắc quy, nguồn điện của ắc quy hầu như đã cạn
kiệt, và Back-UPS đang ch
hoạt động bình thường
UPS không đủ sức cấp điện cho thiết bị đang được sử dụng.
Rút từng thiết bị ra để giảm tải, nếu vẫn không khắc phục được Hãy Liên hệ Hỗ trợ Kỹ
thụ điện vượt quá công suất của Ắc quy Dự phòng
vẫn tiếp tục cấp nguồn cho tải. Hãy liên hệ Hỗ trợ Kỹ thuật
của APC
cấp nguồn cho tải. Hãy liên hệ Hỗ trợ Kỹ thuật của APC
ờ cấp nguồn hiệu dụng để trở về
thuật của APC
ại 1,5 phút
Điện áp Chuyển và Các Thiết lập Độ nhạy
Đèn LED chớp
Một lần một giâyThấp155 - 280Back-UPS sẽ ít thường xuyên chuyển sang nguồn ắc quy hơn. Dùng với thiết bị không
Hai lần một giâyTrung bình
Ba lần một giâyCao165 - 270Back-UPS sẽ chuyển sang nguồn ắc quy trong suốt thời gian có bất cứ dao